Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Prosthet Dent ; 131(2): 313.e1-313.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37978007

RESUMO

STATEMENT OF PROBLEM: Knowledge of the fabrication trueness and margin quality of additively manufactured (AM) laminate veneers (LVs) when different intraoral scanners (IOSs) and finish line locations are used is limited. PURPOSE: The purpose of this in vitro study was to evaluate the fabrication trueness and margin quality of AM LVs with different finish line locations digitized by using different IOSs. MATERIAL AND METHODS: An LV preparation with a subgingival (sub), equigingival (equi), or supragingival (supra) finish line was performed on 3 identical maxillary right central incisor typodont teeth. Each preparation was digitized by using 2 IOSs, (CEREC Primescan [PS] and TRIOS 3 [TS]), and a reference LV for each finish line-IOS pair (n=6) was designed. A total of 90 LVs were fabricated by using these files and urethane acrylate-based definitive resin (Tera Harz TC-80DP) (n=15). Each LV was then digitized by using PS to evaluate fabrication trueness (overall, external, intaglio, and marginal surfaces). Each LV was also qualitatively evaluated under a stereomicroscope (×60), and the cervical and incisal margin quality was graded. Fabrication trueness and cervical margin quality were evaluated by using 2-way analysis of variance, while Kruskal-Wallis and Mann Whitney-U tests were used to evaluate incisal margin quality (α=.05). RESULTS: The interaction between the IOS type and the finish line location affected measured deviations at each surface (P≤.020). PS-sub and TS-supra had higher overall trueness than their counterparts. and the subgingival finish line resulted in the lowest trueness (P≤.005). PS and the subgingival finish line led to the lowest trueness of the external surface (P≤.001). TS-sub had the lowest intaglio surface trueness among the TS subgroups, and PS-sub had higher trueness than TS-sub (P<.001). PS-sub and PS-supra had higher marginal surface trueness than their TS counterparts (P<.001). TS resulted in higher cervical margin quality (P=.001). CONCLUSIONS: Regardless of the IOS tested, subgingival finish lines resulted in the lowest trueness. The effect of IOS on the measured deviations varied according to the surface evaluated and finish line location. The cervical margin quality of AM LVs was higher when TS was used.


Assuntos
Desenho Assistido por Computador , Imageamento Tridimensional , Fluxo de Trabalho , Técnica de Moldagem Odontológica , Modelos Dentários
2.
J Prosthet Dent ; 2023 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-37183123

RESUMO

STATEMENT OF PROBLEM: Additively manufactured composite resins for definitive restorations have been recently introduced. The bond strength between these composite resins and different substrates has not been extensively studied. PURPOSE: The purpose of this in vitro study was to measure the shear bond strength (SBS) between additively manufactured composite resins and dentin and titanium substrates and compare those with the SBS between subtractively manufactured polymer-infiltrated ceramic and the same substrates (dentin and titanium), when different dual-polymerizing resin cements were used. MATERIAL AND METHODS: One hundred and eighty cylinder-shaped specimens (Ø5×5 mm) were prepared from 3 materials recommended for definitive restorations: an additively manufactured composite resin (Crowntec [CT]); an additively manufactured hybrid composite resin (VarseoSmile Crown Plus [VS]); and a subtractively manufactured polymer-infiltrated ceramic (Enamic [EN]) (n=60). Specimens were randomly divided into six subgroups to be cemented to the two substrates (dentin and titanium; n=30) with 1 of 3 resin cements (RelyX Universal, Panavia V5, and Variolink Esthetic DC) (n=10). The restoration surface to be bonded was treated according to the respective manufacturer's recommendations. Dentin surfaces were treated according to the resin cement (Scotchbond Universal Plus Adhesive for RelyX Universal, Panavia V5 Tooth Primer for Panavia V5, and Adhese Universal for Variolink Esthetic DC), while titanium surfaces were airborne-particle abraded, and only the specimens paired with Panavia V5 were treated with a ceramic primer (Clearfil Ceramic Primer Plus). SBS was measured in a universal testing machine at a crosshead speed of 1 mm/min. Failure modes were analyzed under a microscope at ×12 magnification. Data were analyzed by using 2-way analysis of variance and Tukey honestly significant difference tests (α=.05). RESULTS: When SBS to dentin was considered, only restorative material, as a main factor, had a significant effect (P<.001); EN had the highest SBS (P<.001), while the difference in SBS values of CT and VS was not significant (P=.145). As for SBS to titanium, the factors restorative material and resin cement and their interaction had a significant effect (P<.001). Within each resin cement, EN had the highest SBS to titanium (P<.001), and within each restorative material, Variolink resulted in the lowest SBS (P≤.010). Overall, EN and RelyX were associated with the highest SBS to titanium (P≤.013). Mixed failures were predominant in most groups. CONCLUSIONS: Regardless of the substrate or the resin cement used, the subtractively manufactured polymer-infiltrated ceramic had higher shear bond strength than the additively manufactured composite resins. The SBS of the additively manufactured composite resins, whether bonded to dentin or titanium, were not significantly different from each other. Regardless of the restorative material, Variolink DC resulted in the lowest SBS for titanium surfaces.

3.
J Prosthodont ; 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37624691

RESUMO

PURPOSE: To evaluate the effect of polishing and denture cleansers on the surface roughness (Ra ) of new-generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing. MATERIAL AND METHODS: One hundred and fifty disk-shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene-reinforced prepolymerized polymethylmethacrylate (PMMA) (SM-GC), one subtractively manufactured prepolymerized PMMA (SM-PM), two additively manufactured denture base resins (AM-DT and AM-ND), and one heat-polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (ΔE00 ). Two-way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material-time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two-way ANOVA (n = 10) (α = 0.05). RESULTS: Before polishing, Ra varied significantly among the materials. SM-GC and SM-PM had the lowest and AM-ND the highest Ra values (P < 0.001). Polishing significantly reduced Ra of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P ≥ 0.072). Regardless of the denture cleanser, the Ra of AM-DT, AM-ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM-ND had the highest Ra of all the materials, regardless of the cleanser (P ≤ 0.017). AM-DT had higher Ra than SM-PM when distilled water (P = 0.040) and higher Ra than SM-GC, SM-PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the Ra of AM-DT, AM-ND, and CV. For AM-DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P ≤ 0.042), while for AM-ND, distilled water led to the lowest Ra (P ≤ 0.024). For CV, the tablet led to lower Ra than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM-GC had higher ΔE00 than SM-PM and AM-DT (P ≤ 0.034). When NaOCl was used, AM-ND had higher ΔE00 than SM-GC, SM-PM, and AM-DT, while CV and SM-GC had higher ΔE00 than SM-PM and AM-DT (P ≤ 0.039). Finally, when the tablet was used, AM-ND and CV had the highest ΔE00 , while AM-DT had lower ΔE00 than SM-GC (P ≤ 0.015). CONCLUSIONS: The tested materials had unacceptable surface roughness (>0.2 µm) before polishing. Roughness decreased significantly after polishing (<0.2 µm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 µm). Considering previously reported color thresholds, AM-ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM-GC, SM-PM, and AM-DT.

4.
Int J Prosthodont ; 37(7): 99-107, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37988421

RESUMO

PURPOSE: To evaluate the fabrication trueness, intaglio surface adaptation, and marginal integrity of resin-based onlay restorations made via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: An onlay restoration was designed (DentalCAD Galway 3.0) and saved as an STL file to generate a design STL file (DO-STL). Using this design, 45 onlays were fabricated either with AM (3D-printed resin for definitive [AM-D; Tera Harz TC-80DP] and interim [AM-I; Freeprint temp] restorations) or SM (composite resin, Tetric CAD) technologies. Onlays were scanned with an intraoral scanner (CEREC Primescan SW 5.2), and the scans were saved as test STL files (TO-STLs). For trueness evaluation, TO-STLs were superimposed over the DO-STL, and root mean square (RMS) values of overall and intaglio surfaces were measured (Geomagic Control X). For the intaglio surface adaptation and marginal integrity, a triple-scan protocol was performed. Kolmogorov-Smirnov, one-way ANOVA, and post-hoc Tukey honestly significant difference tests were used to analyze data (α = .05). RESULTS: RMS values of intaglio and overall surfaces, intaglio adaptation, and marginal integrity varied among test groups (P < .001). AM-D had the greatest overall surface RMS (P < .001), while SM had the greatest intaglio surface RMS (P < .001). SM had the highest average distance deviations for intaglio surface adaptation and marginal integrity, whereas AM-D had the lowest (P < .001). CONCLUSIONS: AM-D onlays showed lower overall trueness than AM-I onlays and SM definitive onlays. However, AM-D onlays presented high intaglio surface trueness, intaglio surface adaptation, and marginal integrity.


Assuntos
Desenho Assistido por Computador , Planejamento de Prótese Dentária , Humanos , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Restaurações Intracoronárias , Assistência Odontológica
5.
Int J Prosthodont ; 37(7): 133-141, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498865

RESUMO

PURPOSE: To evaluate the flexural strength (FS) and microhardness of various CAD/CAM restorative materials intended for definitive use. The effect of hydrothermal aging on the mechanical properties of these materials was also investigated. MATERIALS AND METHODS: A total of 210 bar-shaped specimens (17 × 4 × 1.5 mm ± 0.02 mm) were fabricated via either subtractive manufacturing (SM) methods-reinforced composite resin (SM-CR), polymer-infiltrated ceramic network (SM-PICN), fine-structured feldspathic ceramic (SMFC), nanographene-reinforced polymethyl methacrylate (PMMA; SM-GPMMA), PMMAbased resin (SM-PMMA)-or additive manufacturing (AM) methods with urethane acrylate-based resins (AM-UA1 and AM-UA2). Specimens were then divided into two subgroups (nonaged or hydrothermal aging; n = 15). A three-point flexural strength test was performed, and five specimens from the nonaged group were submitted to microhardness testing. Specimens were subjected to 10,000 thermal cycles, and the measurements were repeated. RESULTS: Regardless of aging, SM-CR had the highest FS (P < .001), followed by SM-GPMMA (P ≤ .042). In nonaged groups, AM-UA2 had a lower FS than all other materials except SM-FC (P = 1.000). In hydrothermal aging groups, AM specimens had lower FS values than other materials, except SM-PMMA. With regard to microhardness, there was no significant difference found between any of the tested materials (P ≥ .945) in the nonaged and hydrothermal aging groups. CONCLUSIONS: The effect of hydrothermal aging on FS varied depending on the type of restorative material. Regardless of aging condition, SM-CR showed the highest FS values, whereas SM-FC had the highest microhardness. Hydrothermal aging had no significant influence on the microhardness of the tested materials.


Assuntos
Resistência à Flexão , Polimetil Metacrilato , Materiais Dentários , Resinas Compostas , Polímeros , Teste de Materiais , Propriedades de Superfície , Desenho Assistido por Computador
6.
J Dent ; 144: 104941, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38490323

RESUMO

OBJECTIVES: To evaluate how restoration thickness (0.5 mm and 0.7 mm) affects the fabrication trueness of additively manufactured definitive resin-based laminate veneers, and to analyze the effect of restoration thickness and margin location on margin quality. METHODS: Two maxillary central incisors were prepared either for a 0.5 mm- or 0.7 mm-thick laminate veneer. After acquiring the partial-arch scans of each preparation, laminate veneers were designed and stored as reference data. By using these reference data, a total of 30 resin-based laminate veneers were additively manufactured (n = 15 per thickness). All veneers were digitized and stored as test data. The reference and test data were superimposed to calculate the root mean square values at overall, external, intaglio, and marginal surfaces. The margin quality at labial, incisal, mesial, and distal surfaces was evaluated. Fabrication trueness at each surface was analyzed with independent t-tests, while 2-way analysis of variance was used to analyze the effect of thickness and margin location on margin quality (α = 0.05). RESULTS: Regardless of the evaluated surface, 0.7 mm-thick veneers had lower deviations (P < 0.001). Only the margin location (P < 0.001) affected the margin quality as labial margins had the lowest quality (P < 0.001). CONCLUSION: Restoration thickness affected the fabrication trueness of resin-based laminate veneers as 0.7 mm-thick veneers had significantly higher trueness. However, restoration thickness did not affect the margin quality and labial margins had the lowest quality. CLINICAL SIGNIFICANCE: Laminate veneers fabricated by using tested urethane-based acrylic resin may require less adjustment when fabricated in 0.7 mm thickness. However, marginal integrity issues may be encountered at the labial surface.


Assuntos
Resinas Compostas , Adaptação Marginal Dentária , Materiais Dentários , Facetas Dentárias , Incisivo , Propriedades de Superfície , Humanos , Materiais Dentários/química , Resinas Compostas/química , Teste de Materiais , Planejamento de Prótese Dentária , Porcelana Dentária/química , Desenho Assistido por Computador , Cerâmica/química , Poliuretanos/química , Metacrilatos/química
7.
Oper Dent ; 48(2): 176-185, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36745505

RESUMO

This study aimed to investigate the effects of 16% carbamide peroxide (CP) on the relative translucency parameter (RTP) and color stability of thermally aged CAD-CAM glass-ceramics with glazing or polishing. Three different CAD-CAM blocks-feldspathic (VM), lithium disilicate (IPS), and zirconia-reinforced lithium silicate ceramic (VS)-were used in this study. The specimens were divided into two groups (n=10) according to surface treatments (glazing or polishing). Bleaching treatment with 16% CP was applied to the thermally aged specimens. A spectrophotometer (VITA Easyshade Advance) was used to measure the CIE L*a*b*coordinates of the specimens on white and black backgrounds, and RTP and color difference (ΔE00) values were calculated. The surface topography of the specimens and the atomic weight of the elements were analyzed with scanning electron microscopy and energy-dispersive x-ray. The data were analyzed by using the two-way ANOVA test for ΔE00 values and two-way repeated measures ANOVA test for RTP and color parameters values (a=0.05) and the Tukey post-hoc test was used for multiple comparisons of the groups. RTP values were statistically influenced by material type, bleaching, and finishing technique, and the interaction among these factors was found to be significant (p<0.05). ΔE00 values were statistically influenced by material type, finishing technique, and the interaction among these factors was also found to be significant (p<0.05). IPS presented significantly lower RTP and ΔE00 values for both glazed and polished surfaces (p<0.05). 16% CP bleaching agent caused changes in translucency of aged VM and IPS at different levels. Glazed surfaces presented higher color stability in comparison to mechanically polished surfaces for VS (p<0.05).


Assuntos
Cerâmica , Porcelana Dentária , Peróxido de Carbamida , Teste de Materiais , Cor , Propriedades de Superfície , Cerâmica/uso terapêutico , Desenho Assistido por Computador , Zircônio
8.
J Dent ; 139: 104716, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37739057

RESUMO

OBJECTIVES: To evaluate the accuracy of the scans of the combined healing abutment-scan body (CHA-SB) system located at different sites of the maxilla when SBs are replaced in between each scan. METHODS: Three SBs were seated into HAs located at the central incisor, first premolar, and first molar sites of a maxillary model inside a phantom head, and the model was scanned extraorally (CEREC Primescan SW 5.2). This procedure was repeated with new SBs until a total of 10 scans were performed. Standard tessellation language files of CHA-SBs at each implant location were isolated, transferred into analysis software (Geomagic Control X), and superimposed over the proprietary library files to analyze surface (root mean square), linear, and angular deviations. Trueness and precision were evaluated with one-way analysis of variance and Tukey tests. The correlation between surface and angular deviations was analyzed with Pearson's correlation (α=0.05). RESULTS: Molar implant scans had the highest surface and angular deviations (P≤.006), while central incisor implant scans had higher precision (surface deviations) than premolar implant scans (P=.041). Premolar implant scans had higher accuracy than central incisor implant scans on the y-axis (P≤.029). Central incisor implant scans had the highest accuracy on the z-axis (P≤.018). A strong positive correlation was observed between surface and angular deviations (r = 0.864, P<.001). CONCLUSION: Central incisor implant scans mostly had high accuracy and molar implant scans mostly had lower trueness. SBs were mostly positioned apically; however, the effect of SB replacement can be considered small as measured deviations were similar to those in previous studies and the precision of scans was high. CLINICAL SIGNIFICANCE: Repositioning of scan bodies into healing abutments would be expected to result in similar single crown positioning regardless of the location of the implant, considering high scan precision with the healing abutment-scan body system. The duration of the chairside adjustments of crowns in the posterior maxilla may be longer than those in the anterior region.


Assuntos
Implantes Dentários , Reposicionamento de Medicamentos , Maxila/diagnóstico por imagem , Técnica de Moldagem Odontológica , Desenho Assistido por Computador , Modelos Dentários , Imageamento Tridimensional
9.
J Trace Elem Med Biol ; 67: 126774, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33984543

RESUMO

BACKGROUND: Wound healing is an essential physiological process involving many cell types and their products acting in a marvellous harmony to repair damaged tissues. During the healing process, cellular proliferation and extracellular matrix remodelling stages could be interrupted by undesired factors including microorganisms and altered metabolic activities. In such a case, the process requires some external stimulants to accelerate or remediate the healing stages. METHODS: In this study, we report a multifunctional wound healing stimulating agent. In this context, hexagonal boron nitride (hBN) nanoparticles, silver nanoparticles (AgNPs) and polydopamine(pdopa) were used through mussel-inspired chemistry of dopamine to obtain pdopa coated hBN (hBN@pdopa) and AgNPs decorated hBN@pdopa (hBN@pdopa-AgNPs). These two nanostructures were investigated to observe stages of healing. RESULTS: AgNPs were chosen for inflammation reduction and hBN for induced cell proliferation and migration. In in vitro experiments, firstly, high cellular uptake capacity and biocompatibility of hBN@pdopa and hBN@pdopa-AgNPs were evaluated. They were also tested for their reaction against increased concentration of reactive oxygen species (ROS) in injured cells. Finally, their effect on cellular migration, intracellular tube formation and F-actin organization were monitored by light and confocal microscopy, respectively. CONCLUSION: The results clearly indicate that the hBN@pdopa-AgNPs significantly decrease ROS production, promote wound closure, and reorganize tube formation in cells.


Assuntos
Nanopartículas Metálicas , Prata , Cicatrização , Compostos de Boro , Indóis , Polímeros , Espécies Reativas de Oxigênio
10.
Mutat Res ; 534(1-2): 197-9, 2003 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-12504768

RESUMO

A baby born to an epileptic mother had dysmorphological features associated with 47,XXX karyotype. The mother had been treated with valproic acid (1800mg per day) and lamotrigine (100mg per day) throughout pregnancy. Dysmorphological features detected in baby were intrauterine growth retardation, hypertelorism, flattened nasal bridge, low set malformed auriculas, micrognathia, very small an bow-shaped mouth with thin upper lip, cleft palate, arachnodactyly, camptodactyly, secundum atrial septal defect, bilateral hammer toes and decreased creases on the soles. At 6 months old she showed motor retardation. The molecular analysis of parents revealed that extra X chromosome was inherited from the mother. In this case whether the dysmorphological features and 47,XXX karyotype were caused by lamotrigine and valproic acid treatment during pregnancy or coincidence is in question.


Assuntos
Anormalidades Múltiplas/induzido quimicamente , Aberrações Cromossômicas/induzido quimicamente , Cromossomos Humanos X/efeitos dos fármacos , Epilepsia/tratamento farmacológico , Complicações na Gravidez/tratamento farmacológico , Efeitos Tardios da Exposição Pré-Natal , Triazinas/efeitos adversos , Ácido Valproico/efeitos adversos , Anormalidades Induzidas por Medicamentos/genética , Anormalidades Múltiplas/genética , Adulto , Anticonvulsivantes/efeitos adversos , Fissura Palatina/induzido quimicamente , Fissura Palatina/genética , Feminino , Retardo do Crescimento Fetal/induzido quimicamente , Retardo do Crescimento Fetal/genética , Humanos , Lactente , Recém-Nascido , Cariotipagem , Lamotrigina , Linhagem , Gravidez
11.
Indian J Pediatr ; 70(8): 675-7, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-14510091

RESUMO

The effect of single dose povidone-iodine on serum thyrotropin and thyroxine levels and urinary iodine excretion in 30 preterm, 40 full-term newborns and 50 infants at Dr. Sami Ulus Children's Hospital was studied. There was no significant change of thyroid function in any of the groups (p>0.05). Urinary iodine excretion in preterm and full-term groups elevated significantly (p<0.05). The authors conclude that patients who receive single dose povidone-iodine for skin disinfection are not at risk for thyroid disorders.


Assuntos
Anti-Infecciosos Locais/administração & dosagem , Clorexidina/análogos & derivados , Recém-Nascido Prematuro/urina , Iodo/urina , Povidona-Iodo/administração & dosagem , Glândula Tireoide/efeitos dos fármacos , Administração Cutânea , Clorexidina/administração & dosagem , Desinfecção/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Testes de Função Tireóidea , Hormônios Tireóideos/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA