Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Idioma
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nan Fang Yi Ke Da Xue Xue Bao ; 37(1): 113-118, 2017 Jan 20.
Artigo em Zh | MEDLINE | ID: mdl-28109110

RESUMO

OBJECTIVE: To evaluate the effects of polyethylene oxide (PEO) on blood perfusion in hind limb skeletal muscles in a rat model of chronic hind limb ischemia. METHDOS: Twelve rat models of chronic hind limb ischemia established by unilateral femoral artery ligation were randomized into PEO and control groups (n=6) and treated with intravenous infusion of PEO and saline through the internal jugular vein every other day for 2 weeks. Contrast-enhanced ultrasonography was performed after the treatments to evaluate the blood flow in the skeletal muscles at different time points and blood flow reserve in the ischemic hind limbs on day 28. RESULTS: Starting from 7 days after femoral artery ligation, blood flow in the ischemic hind limb skeletal muscles was significantly higher in PEO group than in the control group (P<0.05). On day 28, blood flow reserve in the ischemic hind limb was significantly higher (P=0.012), and blood volume was significantly increased in PEO group as compared that in the control group (P=0.024). CONCLUSIONS: PEO can increase blood flow, blood flow reserve and vascular volume in the hind limb skeletal muscles in rats with chronic hind limb ischemia, suggesting that PEO can promote angiogenesis and arterial formation by increasing blood flow shear stress to improve blood supply of ischemic hind limbs.


Assuntos
Membro Posterior/efeitos dos fármacos , Isquemia/tratamento farmacológico , Músculo Esquelético/efeitos dos fármacos , Polietilenoglicóis/farmacologia , Animais , Volume Sanguíneo/efeitos dos fármacos , Volume Sanguíneo/fisiologia , Doença Crônica , Modelos Animais de Doenças , Artéria Femoral , Membro Posterior/irrigação sanguínea , Isquemia/diagnóstico por imagem , Ligadura , Músculo Esquelético/irrigação sanguínea , Neovascularização Fisiológica , Distribuição Aleatória , Ratos , Fluxo Sanguíneo Regional/efeitos dos fármacos , Fluxo Sanguíneo Regional/fisiologia
2.
Nan Fang Yi Ke Da Xue Xue Bao ; 30(4): 884-7, 2010 Apr.
Artigo em Zh | MEDLINE | ID: mdl-20423873

RESUMO

OBJECTIVE: To observe the effect of polyethylene oxide (PEO) solution at different concentrations on abdominal aortic blood flow and vascular resistance in rats and evaluate the safety and drag-reducing effect of PEO solution. METHODS: Thirty-two rats were anesthetized and randomly divided into 4 groups. An ultrasonic flow probe was deployed on the abdominal aorta (5 mm above the common iliac artery) to measure the blood flow. The carotid artery pressure, iliac artery pressure, iliac vein pressure, central venous pressure (CVP) and ECG were also monitored. Saline or different concentrations of PEO [(1x10(-6)(low), 1x10(-5)(middle) and 5x10(-5)(high) g/ml)] were injected in the 4 groups of rats through the caudal vein at a constant rate of 5 ml/h for 20 min, and the changes of the vascular resistance was observed. RESULTS After injections of 1x10(-6) and 1x10(-5) g/ml PEO, the abdominal aortic flow increased significantly (P<0.05) while the vascular resistance was reduced (P(low)=0.052, P(middle)<0.001) as compared to those in the saline control group. Following the injection with 5x10(-5) g/ml PEO, the abdominal aortic flow increased to a threshold in the initial 4 min, after which it rapidly decreased to approach the baseline levels despite continuous infusion. Blood pressure remained stable after the injections except for 5x10(-5) g/mlPEO injection, which resulted in a reduction of the blood pressure by about 10 mmHg (P=0.014). The heart rate and CVP both underwent no significant changes following the injections. CONCLUSION: The drag-reducing effect of PEO is closely related to its concentration, and compared with 1x10(-6) g/ml, 1x10(-5) g/ml PEO more effectively increases the blood flow and decreases the resistance. The effectiveness and safety of EPO are attenuated at a concentration higher than 5x10(-5) g/ml.


Assuntos
Aorta Abdominal/fisiologia , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Polietilenoglicóis/farmacologia , Resistência Vascular/efeitos dos fármacos , Animais , Relação Dose-Resposta a Droga , Masculino , Distribuição Aleatória , Ratos , Ratos Wistar
3.
Nan Fang Yi Ke Da Xue Xue Bao ; 30(5): 960-2, 2010 May.
Artigo em Zh | MEDLINE | ID: mdl-20501367

RESUMO

OBJECTIVE: To investigate the drag-reducing effect of polyethylene oxide (PEO) on the velocity of red blood cells in rat cremaster microcirculation. METHODS: Blood samples were collected from 6 Wistar male rats (100-110 g) via the post-orbital venous plexus. The red blood cells were separated by centrifugation and labeled by fluorescinisothiocyate (FITC). After successful establishment of cremaster model, the labeled red blood cells were injected into the jugular vein, and the microcirculation was observed and recorded under fluorescence microscope. The hemodynamic parameters and microcirculation video was recorded every 4 min since 4 min before PEO or normal saline injection. Both PEO (10 ppm) and normal saline was injected into the same rat in random sequence at a constant rate of 3.5 ml/h for 20 min followed by observation for another 20 min. The velocity of the labeled-red blood cells was determined by IPP 6.0 software. RESULTS: Compared with normal saline, PEO significantly increased the velocity of the red blood cells in the rat cremaster microcirculation (498.7-/+182.89 microm/s vs 773.54-/+308.27 microm/s, P=0.012). No significant changes in the heart rate and arterial blood pressure were observed during the experiment (P=0.836, P=0.420). CONCLUSION: PEO at an extremely low concentration can significantly increase the velocity of the red blood cells in rat cremaster microcirculation and produces no significant impact on heart rate and arterial blood pressure.


Assuntos
Microcirculação/efeitos dos fármacos , Músculo Liso/irrigação sanguínea , Polietilenoglicóis/farmacologia , Animais , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Masculino , Microcirculação/fisiologia , Ratos , Ratos Wistar , Testículo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA