RESUMO
The aim of this systematic review was to investigate the association between the different factors of loading protocols and the long-term stability of micro-screws from biomechanical and histological viewpoints. Searches were performed on PubMed, Embase, Cochrane Library, Wanfang and CNKI databases for animal experiments comparing loading protocols and the long-term stability of micro-screws. Among 1011 detected papers, 16 studies met the eligibility criteria and were selected for analysis. Most studies showed medium methodological quality for evaluation of micro-screws' long-term stability. Five studies reported that loading would not destroy the long-term stability of micro-screws. Three studies indicated that low-intensity immediate loading or a 3-week minimal healing time was acceptable. Two studies reported that the loading magnitude was a controversial issue with regard to the micro-screws' long-term stability. Two studies suggested that counterclockwise loading could decrease the long-term stability of micro-screws. In conclusion, immediate loading below 100g force, healing time greater than 3 weeks, regular loading below 200g force and a clockwise direction of force supported the long-term stability of micro-screws. Further studies relating to the combination of varying loading conditions will be needed.
Assuntos
Parafusos Ósseos/normas , Implantação Dentária/métodos , Implantes Dentários/normas , Procedimentos de Ancoragem Ortodôntica/métodos , Animais , Fenômenos Biomecânicos , Implantação Dentária/instrumentação , Desenho de Equipamento , Modelos Animais , Procedimentos de Ancoragem Ortodôntica/instrumentação , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , CicatrizaçãoRESUMO
A diffusive gradients in thin films (DGT) device with polyquaternary ammonium salt (PQAS) as a novel binding agent (PQAS DGT) combined with graphite furnace atomic absorption spectrometry (GFAAS) was developed for the selective sampling and measurement of Cr (VI) in water. The performance of PQAS DGT was independent of pH 3-12 and ionic strength from 1 × 10(-3) to 1 molL(-1). DGT validation experiments showed that Cr (VI) was measured accurately as well as selectively by PQAS DGT, whereas Cr (III) was not determined quantitatively. Compared with diphenylcarbazide spectrophotometric method (DPC), the measurement of Cr (VI) with PQAS DGT was agreement with that of DPC method in the industrial wastewater. PQAS-DGT device had been successfully deployed in local freshwater. The concentrations of Cr (VI) determined by PQAS DGT coupled with GFAAS in Nuer River, Ling River and North Lake were 0.73 ± 0.09 µg L(-1), 0.50 ± 0.07 µg L(-1) and 0.61 ± 0.07 µg L(-1), respectively. The results indicate that PQAS DGT device can be used for the selective sampling and measurement Cr (VI) in water and its detection limit is lower than that of DPC method.