Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chin J Traumatol ; 26(6): 351-356, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37838578

RESUMO

PURPOSE: As common clinical screening tests cannot effectively predict a difficult airway, and unanticipated difficult laryngoscopy remains a challenge for physicians. We herein used ultrasound to develop some point-of-care predictors for difficult laryngoscopy. METHODS: This prospective observational study included 502 patients who underwent laryngoscopy and a detailed sonographic assessment. Patients under 18 years old, or with maxillofacial deformities or fractures, limited mouth opening, limited neck movement or history of neck surgery were excluded from the study. Laryngoscopic views of all patients were scored and grouping using the modified Cormack-Lehane (CL) scoring system. The measurements acquired comprised tongue width, the longitudinal cross-sectional area of the tongue, tongue volume, the mandible-hyoid bone distance, the hyoid bone-glottis distance, the mandible-hyoid bone-glottis angle, the skin-thyrohyoid membrane distance, the glottis-superior edge of the thyroid cartilage distance (DGTC), the skin-hyoid bone distance, and the epiglottis midway-skin distance. ANOVA and Chi-square were used to compare differences between groups. Logistic regression was used to identify risk factors for difficult laryngoscopy and it was visualized by receiver operating characteristic curves and nomogram. R version 3.6.3 and SPSS version 26.0 were used for statistical analyses. RESULTS: Difficult laryngoscopy was indicated in 49 patients (CL grade Ⅲ - Ⅳ) and easy laryngoscopy in 453 patients (CL grade Ⅰ - Ⅱ). The ultrasound-measured mandible-hyoid bone-glottis angle and DGTC significantly differed between the 2 groups (p < 0.001). Difficult laryngoscopy was predicted by an area under the curve (AUC) of 0.930 with a threshold mandible-hyoid bone-glottis angle of 125.5° and by an AUC of 0.722 with a threshold DGTC of 1.22 cm. The longitudinal cross-sectional area of the tongue, tongue width, tongue volume, the mandible-hyoid distance, and the hyoid-glottis distance did not significantly differ between the groups. CONCLUSION: Difficult laryngoscopy may be anticipated in patients in whom the mandible-hyoid bone-glottis angle is smaller than 125.5° or DGTC is larger than 1.22 cm.


Assuntos
Laringoscopia , Língua , Humanos , Adolescente , Estudos Prospectivos , Língua/diagnóstico por imagem , Sistema Respiratório , Ultrassonografia
2.
Mater Sci Eng C Mater Biol Appl ; 69: 1175-82, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27612815

RESUMO

Bio-inorganic films and drug-eluting coatings are usually used to improve the hemocompatibility and inhibit restenosis of vascular stent; however, above bio-performances couldn't combine together with single materials. In the present study, we reported a simple approach to fabricate a metal film with the aim of imparting the stent with good blood compatibility and accelerating endothelialization. The films with various ratios of Cu and Ti were prepared through the physical vapor deposition. Phase structure and element composition were investigated by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), respectively. The releasing volume of copper ion in Cu/Ti film was determined by immersing test. The hemolysis ratio, platelet adhesion and clotting time were applied to evaluate the hemocompatibility. The proliferative behaviors of endothelial cells and smooth muscle cells under certain copper concentration were investigated in vitro and in vivo. Results indicated that copper-titanium films exhibited good hemocompatibility in vitro; however, the increase of Cu/Ti ratio could lead to increasing hemolysis ratio. Endothelial cells displayed more proliferative than smooth muscle cells when the copper concentration was <7.5µg/ml, however both cells tended to apoptosis to some degree when the copper concentration was increased. The complete endothelialization of the film with low copper in vivo was observed at the 2nd week, indicating that the copper-titanium film with the lower copper concentration could promote endothelialization. Therefore, the inorganic copper-titanium film could be potential biomaterials to improve blood compatibility and accelerating endothelialization of vascular stents.


Assuntos
Materiais Revestidos Biocompatíveis/química , Cobre/química , Stents , Titânio/química , Animais , Aorta/efeitos dos fármacos , Aorta/metabolismo , Adesão Celular/efeitos dos fármacos , Eritrócitos/citologia , Eritrócitos/efeitos dos fármacos , Hemólise/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana , Humanos , Espectroscopia Fotoeletrônica , Adesividade Plaquetária/efeitos dos fármacos , Coelhos , Aço Inoxidável/química , Propriedades de Superfície , Molhabilidade , Difração de Raios X
3.
Thorac Cancer ; 6(6): 808-11, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26557924

RESUMO

Gardner's syndrome is a hereditary disorder inherited as an autosomal dominant with high penetrance and variable expression that is caused by a mutation of the adenomatous polyposis coli gene. It is characterized by gastrointestinal polyps associated with multiple osteomas, dental anomalies, and skin and soft tissue tumors. We present a case of 30-year-old female patient with Gardner's syndrome who presented with a giant mediastinal thymolipoma. The tumor was completely excised through a bilateral posterolateral thoracotomy. There was no recurrence after 20 months of follow-up. We therefore suggest that physicians who regularly treat patients with Gardner's syndrome carefully examine for thoracic manifestations.

4.
Biomed Mater Eng ; 26(1-2): 39-47, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26484554

RESUMO

Surface modification is one approach to enhance the biocompatibility of implanted cardiovascular devices. In this work, a copper-containing film used to blood contacted biomaterials was prepared by vacuum arc deposition. The phase composition of the films was investigated via X-ray diffraction, and the adherence strength of the films was evaluated with conventional deformation tests. Blood compatibility of the films was characterized by hemolysis ratio, clotting time and platelet adhesion etc. The surface of inferior vena cava filters were smooth and uniform, no cracks or delaminations were observed on the deformed surface. These results indicate that the mechanical behavior of the films is suitable for withstanding deformation stresses as operation in clinic. Good blood compatibility of the copper-containing films was identified through experiment in vitro, the activated partial thromboplastin times (APTTs) of Cu/Ti films were similar to that of the uncoated substrate, and Cu/Ti films were also found to inhibit platelet adhesion comparing to the nitinol substrate. However, with increasing ratio of Cu/Ti, the hemolysis ratio increased, resulting in platelet damage. These results indicate that the copper-containing film has potential application on blood contacted devices.


Assuntos
Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Fenômenos Fisiológicos Sanguíneos/efeitos dos fármacos , Plaquetas/efeitos dos fármacos , Cobre/química , Cobre/toxicidade , Plaquetas/patologia , Células Cultivadas , Força Compressiva , Estudos de Viabilidade , Humanos , Teste de Materiais , Membranas Artificiais , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA