Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 89(7): 1259-1267, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471091

RESUMO

IMPORTANCE: Long-term outcomes of an interwoven nitinol stent design represent the best in class for treatment of lower limb arterial obstructive disease METHODS: The subjects were enrolled in an open single arm study comparing the outcomes to an FDA mandated objective performance goal (OPG). RESULTS: About 325 patients (264 intention-to-treat and 64 roll-in subjects) were enrolled. Mean follow-up period was 887+/- 352 days. Treated lesion lengths were 7.8 cm ± 4.3 cm in the trial with chronic total occlusions comprising 24.6% (65/264) of subjects. Freedom from clinically driven target lesion revascularization (CD-TLR) at 12 months was 89%, at 24 and 36 months it was 84% and 82% respectively. The difference in the 12 month CD-TLR was 7% at 36 months. The difference of clinically driven-TLR at 36 months in those subjects who received their stents deployed nominally in length, compressed or elongated (between -10% and +10% nominal length) had an impact on the CD-TLR. At 2 and 3 years, freedom from CD-TLR in minimal compression was 86.7%, and was 90.0% for moderate compression. In those stents deployed with minimal, moderate, or severe elongation (10-20%, 20-40%, or >40%, respectively) freedom from CD-TLR of 84.1%, 87.4%, and 77.0% respectively at 12 months. At 2 and 3 years, freedom from CD-TLR for moderate elongation was 81.8% and 78.2%, and for severe elongation was 63.4% and 42.3%, respectively. Fractures were distinctly uncommon with this stent with a single facture event in the 36 month follow-up period. DISCUSSION: The interwoven nitinol design stent is a stent that achieves an excellent primary patency but further maintains the durability of the stent through 36 months. Optimal stent deployment remains critical to the performance of this stent device and requires optimal vessel preparation. © 2017 Wiley Periodicals, Inc.


Assuntos
Ligas , Materiais Biocompatíveis , Procedimentos Endovasculares/instrumentação , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/terapia , Stents , Idoso , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Circ Cardiovasc Interv ; 8(5)2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25969545

RESUMO

BACKGROUND: Stent-based therapy in the superficial femoral and popliteal arteries in patients with peripheral artery disease is compromised by restenosis and risk of stent fracture or distortion. A novel self-expanding nitinol stent was developed that incorporates an interwoven-wire design (Supera stent, IDEV Technologies, Inc, Webster, TX) to confer greater radial strength, flexibility, and fracture resistance. METHODS AND RESULTS: This prospective, multicenter, investigational device exemption, single-arm trial enrolled 264 patients with symptomatic peripheral artery disease undergoing percutaneous treatment of de novo or restenotic lesions of the superficial femoral or proximal popliteal (femoropopliteal) artery. Freedom from death, target lesion revascularization, or any amputation of the index limb at 30 days (+ 7 days) postprocedure was achieved in 99.2% (258/260) of patients (P < 0.001). Primary patency at 12 months (360 ± 30 days) was achieved in 78.9% (180/228) of the population (P < 0.001). Primary patency by Kaplan-Meier analysis at 12 months (360 days) was 86.3%. No stent fracture was observed by independent core laboratory analysis in the 243 stents (228 patients) evaluated at 12 months. Clinical assessment at 12 months demonstrated improvement by at least 1 Rutherford-Becker category in 88.7% of patients. CONCLUSIONS: The SUPERB Trial, an investigational device exemption study using an interwoven nitinol wire stent in the femoropopliteal artery, achieved the efficacy and safety performance goals predesignated by the Food and Drug Administration. On the basis of the high primary patency rate, absence of stent fracture, and significant improvements in functional and quality-of-life measures, the Supera stent provides safe and effective treatment of femoropopliteal lesions in symptomatic patients with peripheral artery disease. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00933270.


Assuntos
Ligas , Procedimentos Endovasculares/instrumentação , Artéria Femoral/fisiopatologia , Doença Arterial Periférica/terapia , Artéria Poplítea/fisiopatologia , Stents , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA