Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Gen Dent ; 66(6): 56-59, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30444708

RESUMO

This pediatric study aimed to assess the masticatory function of patients with anterior open bite through a method that utilizes colorimetric capsules. The sample consisted of 106 patients aged 7-11 years, of whom 51 presented with anterior open bite (experimental group) and 55 presented with normal overbite (control group). The colorimetric capsules used in this evaluation contained basic fuchsin granules, which were used to produce a solution after they were ground during chewing. Each patient was asked to chew 1 capsule for 20 seconds. The absorbance of the obtained solutions was analyzed with a spectrophotometer. Greater masticatory efficiency is directly related to the greater light absorbance of a solution, since light absorbance increases with solution concentration. A nonparametric Wilcoxon test indicated that the solutions obtained from the control group presented significantly greater light absorbance than did those from the experimental group (P < 0.05). Therefore, children with an anterior open bite exhibited less masticatory efficiency than those with a normal overbite.


Assuntos
Mordida Aberta/diagnóstico , Cápsulas , Estudos de Casos e Controles , Criança , Colorimetria/métodos , Humanos , Mastigação/fisiologia , Mordida Aberta/fisiopatologia
2.
J Mech Behav Biomed Mater ; 143: 105888, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178636

RESUMO

Y-TZP/MWCNT-SiO2 nanocomposite was synthesized by co-precipitation and hydrothermal treatment methods. After the characterization of the MWCNT-SiO2 powder, specimens were obtained from the synthesized material Y-TZP/MWCNT-SiO2 by uniaxial pressing for a second characterization and later comparison of its optical and mechanical properties with the conventional Y-TZP. The MWCNT-SiO2 was presented in bundles of carbon nanotubes coated by silica (mean length: 5.10 ± 1.34 µm /D90: 6.9 µm). The composite manufactured was opaque (contrast ratio: 0.9929 ± 0.0012) and had a white color with a slightly difference from the conventional Y-TZP (ΔE00: 4.4 ± 2.2) color. The mechanical properties of Y-TZP/MWCNT-SiO2: vickers hardness (10.14 ± 1.27 GPa; p = 0.25) and fracture toughness (4.98 ± 0.30 MPa m1/2; p = 0.39), showed no significant difference from the conventional Y-TZP (hardness: 8.87 ± 0.89; fracture toughness: 4.98 ± 0.30 MPa m1/2). However, for flexural strength (p = 0.003), a lower value was obtained for Y-TZP/MWCNT-SiO2 (299.4 ± 30.5 MPa) when compared to the control Y-TZP (623.7 ± 108.8 MPa). The manufactured Y-TZP/MWCNT-SiO2 composite presented satisfactory optical properties, however the co-precipitation and hydrothermal treatment methods need to be optimized to avoid the formation of porosities and strong agglomerates, both from Y-TZP particles and MWCNT-SiO2 bundles, which lead to a significant decrease in the material flexural strength.


Assuntos
Nanocompostos , Nanotubos de Carbono , Dióxido de Silício , Teste de Materiais , Zircônio , Ítrio , Propriedades de Superfície , Materiais Dentários
3.
J Adhes Dent ; 14(1): 47-50, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21734978

RESUMO

PURPOSE: To evaluate the flexural strength of two fixed dental prosthesis (FDP) designs simulating frameworks of adhesive fixed partial prostheses, reinforced or not by glass fiber. MATERIALS AND METHODS: Forty specimens, made with composite resin, were divided into 4 groups according to the framework design and the presence of fiber reinforcement: A1 - occlusal support; A2: occlusal support + glass fiber; B1: occlusal and proximal supports; B2: occlusal and proximal supports + glass fiber. The specimens were subjected to the three-point bending test, and the data were submitted to two-way ANOVA and Tukey's test (5%). RESULTS: Group A2 (97.9 ± 38 N) was statistically significantly different from all other experimental groups, presenting a significantly lower mean flexural strength. CONCLUSION: The use of glass fibers did not improve the flexural strength of composite resin, and designs with occlusal and proximal supports presented better results than designs simulating only occlusal support.


Assuntos
Resinas Compostas/química , Colagem Dentária , Materiais Dentários/química , Prótese Parcial Fixa , Vidro/química , Análise do Estresse Dentário/instrumentação , Planejamento de Dentadura , Humanos , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Maleabilidade , Estresse Mecânico , Propriedades de Superfície
4.
Gen Dent ; 60(1): e13-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22313987

RESUMO

This article presents a prototype of an intraoral device that facilitates preparation of parallel guide planes with accuracy and minimal occlusal divergence. The design of this device facilitates transfer of the desired path of insertion from the diagnostic cast to the mouth quickly and efficiently.


Assuntos
Oclusão Dentária , Planejamento de Dentadura/instrumentação , Prótese Parcial Removível , Dente Suporte , Humanos , Ajuste de Prótese/instrumentação , Preparo Prostodôntico do Dente/instrumentação
5.
Eur J Prosthodont Restor Dent ; 18(3): 107-10, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21077418

RESUMO

The objective of this study was to evaluate the flexural strength of denture base resin reinforced with glass fibers and with a laboratorial composite resin. Group G1 was formed with specimens made of acrylic resin. Group G2 was formed with the same acrylic resin but reinforced with a glass-fiber system, and G3 was reinforced with the composite resin. A flexural strength test was performed in all groups (n=10). The mean value for the G1 was 86.70 MPa +/- 6.48, for G2 it was 86.60 MPa +/- 15.01 and for G3 it was 108.90 + 11.03. The addition of glass fiber did not increase the flexural strength however the use of a resin-based composite produced significant reinforcement.


Assuntos
Resinas Acrílicas/química , Análise do Estresse Dentário , Bases de Dentadura , Análise de Variância , Resinas Compostas , Vidro , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Maleabilidade , Estatísticas não Paramétricas
6.
J Oral Biol Craniofac Res ; 9(2): 183-186, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31211032

RESUMO

The aim of this study was to evaluate and compare changes in linear distance and inclination of lower incisors and canines and intercanine distance after a 30 months orthodontic treatment with self-ligating appliances. Seven patients were treated orthodontically with a Roth prescription passive self-ligating bracket. To perform the measurements and comparisons, CBCT scans were taken before the start of the orthodontic treatment (T1) and after a period of 30 months treatment (T2). The following measurements were performed: (1) the lower incisors and canines inclination in relation to the mandibular plane, (2) intercanine linear distance in millimeters and (3) linear distance in millimeters of the incisal and apical part of lower anterior teeth to a plane (POGM) passing through pogonion point and perpendicular to the mandibular plane. No significant difference were observed between T1 and T2 for canine inclination (p = 0.835), incisors inclination (p = 0.149), canine incisal distance to POGM (p = 0.423) and incisors incisal distance to POGM (p = 0.966), however canine apical distance (p = 0.049) and incisors apical distance (p = 0.002) to POGM was lower at T1 than at T2. The intercanine distance was significantly lower (p = 0.022) at T1 when compared to T2. The use of passive self-ligating brackets in orthodontic treatment to solve 4 mm tooth crowding were able to produce dental arch expansion by bodily tooth movement.

7.
Dent Mater ; 30(11): e283-8, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24950806

RESUMO

OBJECTIVES: The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw. METHODS: Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured. RESULTS: FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region. SIGNIFICANCE: In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment.


Assuntos
Dente Suporte , Análise de Elementos Finitos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA