1.
Clin Oral Investig ; 27(4): 1745-1755, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36441269

RESUMO

OBJECTIVES: The effects of different concentrations of titanium dioxide (TiO2) into 40% hydrogen peroxide (HP) were evaluated as regards the effectiveness of dental color change either associated with activation by polywave LED light or not. MATERIALS AND METHODS: TiO2 (0, 1, 5, or 10%) was incorporated into HP to be applied during in-office bleaching (3 sessions/40 min each). Polywave LED light (Valo Corded/Ultradent) was applied or not in activation cycles of 15 s (total time of 2 min). The color of 80 third molars separated into groups according to TiO2 concentration and light activation (n = 10) was evaluated at baseline and at time intervals after the 1st, 2nd, and 3rd bleaching sessions. RESULTS: WID value was significantly higher when using HP with 5% TiO2 in the 2nd session than the values in the other groups (p < 0.05). After the 2nd and 3rd sessions, the ΔEab value was significantly higher when activated with light (p < 0.05) for all agents containing TiO2 or not. Zeta potential and pH of the agents were not modified by incorporating TiO2 at the different concentrations. CONCLUSIONS: The 5% TiO2 in the bleaching agent could enhance tooth bleaching, even without light application. Association with polywave LED light potentiated the color change, irrespective of the presence of TiO2 in the bleaching gel. CLINICAL SIGNIFICANCE: HP with 5% TiO2 could lead to a greater tooth bleaching response in the 2nd clinical session, as well as the polywave light can enhance color change.


Assuntos
Clareadores , Nanotubos , Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/farmacologia , Clareadores Dentários/farmacologia
2.
Am J Dent ; 34(6): 300-306, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35051316

RESUMO

PURPOSE: To evaluate the color, surface roughness and microhardness of human dental enamel subjected to brushing with whitening dentifrices. METHODS: The enamel samples (4 x 4 x 2 mm) were darkened using 0.2% chlorhexidine and black tea, and were randomly divided into seven groups (n= 15) for brushing cycles with only water; control; conventional dentifrice (Colgate Maximum Anticaries Protection); dentifrice containing 2% hydrogen peroxide (Colgate Luminous White Advanced); dentifrice containing sodium tripolyphosphate (Sensodyne True White); dentifrice containing activated charcoal (Black is White); and dentifrice containing blue covarine (Close Up White Now). The samples were submitted to 1,000 and 30,000 brushing cycles. The color values (CIE L*a*b*), surface roughness (Ra) and microhardness (Knoop) were recorded at four time points: baseline, after staining, after 1,000 and after 30,000 brushing cycles. The data were submitted to statistical analyses using paired t-test, ANOVA and Tukey. RESULTS: The color analysis, roughness and microhardness results showed interaction between the effect of the dentifrices and the time point (P< 0.001). The bleaching dentifrices brought about color changes (ΔE) significantly greater than those obtained with conventional dentifrices and the control; however, there were no significant color changes among the bleaching dentifrices. When the color coordinates were evaluated individually, the L* values increased and the a* and b* values decreased throughout the experiment. The conventional toothpaste and the toothpastes containing blue covarine, activated charcoal or hydrogen peroxide promoted a statistically significant increase in the surface roughness of the samples after the last brushing cycle. The sodium tripolyphosphate dentifrice caused a progressive reduction in roughness. The microhardness increased statistically after 30,000 cycles for the conventional toothpaste, blue covarine and hydrogen peroxide. It was concluded that the whitening dentifrices lightened the samples, which evidenced greater luminosity and reduction in reddish and yellow tones. Moreover, they did not have deleterious effects on microhardness, and caused acceptable changes in surface roughness. CLINICAL SIGNIFICANCE: Dentifrices with different whitening strategies changed the color of the samples, resulting in samples with greater luminosity and reduced reddish and yellowish tones. They also caused changes in surface roughness within the acceptable clinical limit and did not have a deleterious effect on the microhardness of dental enamel.


Assuntos
Dentifrícios , Esmalte Dentário , Humanos , Peróxido de Hidrogênio , Escovação Dentária
3.
Clin Oral Investig ; 20(4): 857-63, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26319980

RESUMO

OBJECTIVES: The objective of this study was to evaluate the inhibition of demineralization around enamel-dentin/restoration interface after dentin pretreatment with 2.5% titanium tetrafluoride (TiF4). MATERIALS AND METHODS: Forty dental class V cavities at the cementoenamel junction were distributed into four groups (n = 10), according to the presence or absence of TiF4 and to the adhesive system (Clearfil SE Bond/CL and Adper EasyOne/AD), and restored with a resin composite. A dynamic pH cycling model was used to induce the development of artificial caries lesions. After sectioning the dental blocks, Knoop microhardness tests were performed at different depths (20, 40, and 60 µm from the occlusal margin of the restoration) and at different distances (100, 200, and 300 µm from the adhesive interface). Repeated measures three-way analysis of variance (ANOVA) and Tukey's test were used (α = 0.05). RESULTS: For enamel, there were no differences in the microhardness values for CL, AD, and TiF4-AD at depths, regardless of the distances. Considering each depth, there were no significant differences among treatments. For dentin, ANOVA showed no significant interaction among the independent variables treatment*distance*depth (p = 0.994), no significant interaction between treatment*depth (p = 0.722), no significant interaction between treatment*distance (p = 0.265), no significant interaction between depth*distance (p = 0.365), and no significant effect on treatment (p = 0.151), depth (p = 0.067), or distance (p = 0.251). CONCLUSIONS: Dentin pretreatment of the cavity walls with TiF4 before self-etching adhesive systems was not effective in inhibiting demineralization around the enamel-dentin/restoration interfaces. CLINICAL RELEVANCE: The mechanism of incorporating fluoride in enamel and dentin of the cavity walls to inhibit demineralization around restorations seems ineffective when using TiF4 as a dentin pretreatment.


Assuntos
Adesivos , Cariostáticos , Dentina , Resinas Compostas , Colagem Dentária , Esmalte Dentário , Adesivos Dentinários , Dureza , Humanos , Cimentos de Resina
4.
J Clin Pediatr Dent ; 40(1): 62-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26696109

RESUMO

OBJECTIVE: This study evaluated the antimicrobial effect of papain-based gel (Papacárie/ P) followed by self-etching adhesive systems with MDPB monomer (Clearfil Protect Bond/ PB) and without (Clearfil SE Bond/ Cl) on Streptococcus mutans (Sm) and Lactobacillus casei (Lc). STUDY DESIGN: The dentin of twenty human teeth was exposed to prepare four cylindrical cavities in each tooth. The cavities were incubated with Sm or Lc. One cavity from each tooth served as contamination control (positive control group); the other three were treated with P, P+CL and P+PB. The cavities were sealed and after 72 h, dentin samples were collected and microbial cultivation was performed. Microbial count was undertaken (CFUs/mg) according to the morphological characteristics for Sm and Lc. Analysis of variance and Tukey's test were applied (α=5%). RESULTS: For Sm, groups P+Cl and P+PB had lower microbial count than group P (no statistical differences between P+Cl and P+PB). For Lc, group P+Cl had microbial count similar to group P. There was statistical difference between cavities treated with P and P+PB but none between groups P+Cl and P+PB. After using P, both self-etching adhesives showed antimicrobial potential, although Clearfil Protect Bond proved better against Lc. CONCLUSIONS: Both self-etching adhesives used after application of Papacárie showed antimicrobial potential, although Clearfil Protect Bond proved more effective against Lactobacillus casei.


Assuntos
Anti-Infecciosos/farmacologia , Preparo da Cavidade Dentária/métodos , Adesivos Dentinários/química , Lacticaseibacillus casei/efeitos dos fármacos , Papaína/farmacologia , Streptococcus mutans/efeitos dos fármacos , Anti-Infecciosos/química , Carga Bacteriana/efeitos dos fármacos , Cárie Dentária/microbiologia , Dentina/efeitos dos fármacos , Dentina/microbiologia , Humanos , Teste de Materiais , Compostos de Piridínio/química , Cimentos de Resina/química
5.
Gen Dent ; 63(5): 52-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26325643

RESUMO

The aim of this in vitro study was to evaluate the calcium and phosphorus concentrations in enamel surfaces before, during, and after treatment with in-office 35% hydrogen peroxide bleaching agents with 2% calcium gluconate (WCa) or without calcium gluconate (W). Twenty sound human third molars were divided into 2 groups of 10. The bleaching agents were applied to the tooth surfaces in accordance with the manufacturer's instructions: WCa, 40 minutes per day at 3 sessions with 7-day intervals; W, 3 × 15 minutes per day at 3 sessions with 7-day intervals. Enamel microbiopsies were performed prior to the bleaching treatment, immediately after each bleaching session (first, second, and third applications), and 7 and 14 days following the last bleaching treatment. The concentration levels of calcium and phosphorus in the microbiopsy specimens were recorded spectrophotometrically. There was a statistically significant decrease in the calcium concentration 7 days after the last bleaching treatment, but there was a recovery to baseline values at 14 days, regardless of the bleaching agent used (WCa and W). When W was used, there was no difference in the phosphorus concentration over time. The phosphorus concentration in the WCa group decreased after the third application, showing a significant difference from the W group at this time. However, an increase in the phosphorus concentration was observed in the posttreatment period, and no significant differences were observed between values at baseline and those at 14 days posttreatment. The in-office bleaching gel containing 2% calcium gluconate did not affect the calcium and phosphorus concentrations in enamel as compared to a calcium-free bleaching agent.


Assuntos
Cálcio/análise , Esmalte Dentário/química , Fósforo/análise , Clareadores Dentários/uso terapêutico , Clareamento Dental/métodos , Cálcio/uso terapêutico , Gluconato de Cálcio/uso terapêutico , Esmalte Dentário/efeitos dos fármacos , Humanos , Peróxido de Hidrogênio/uso terapêutico , Técnicas In Vitro , Fósforo/uso terapêutico , Clareadores Dentários/administração & dosagem , Clareadores Dentários/análise
6.
J Contemp Dent Pract ; 15(4): 385-91, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25576100

RESUMO

AIM: The purpose of the present study was to evaluate (1) the one-step adhesive system application method (doubling the adhesive coatings) in regard to microtensile bond strength (MTB) and (2) the interfacial morphology of one-step adhesives to sound vs demineralized dentin. MATERIALS AND METHODS: Forty dentin fragments were randomly allocated to 2 groups: D. demineralized dentin and S. sound dentin. Specimens were also subdivided into 2 groups (n = 10), according to the one-step adhesive [AEO (Adper Easy One), 3M ESPE] application method: M, According to the manufacturer's instructions, and D, based on the application of two consecutive layers. After adhesive light polymerization, a resin composite block (Filtek Z250, 3M ESPE) was built on the dentin surface. Resin-tooth blocks were sectioned into 0.9 mm thick slabs, and one slab of each block was prepared for adhesive interface analysis by scanning electron microscopy (SEM). The remaining slabs were sectioned into 0.8 mm(2) sticks that were subjected to tensile stress (0.5 mm/min). Data were subjected to two-way ANOVA and Tukey's test (α = 0.05). RESULTS: The application of two consecutive layers of AEO adhesive system did not Influence MTB values for sound dentin. When two consecutive layers of one-step adhesive system were applied, MTB was statistically greater in demineralized vs sound dentin. SEM analysis demonstrated that the application of two consecutive adhesive layers to sound and demineralized dentin produced longer resin tags. CONCLUSION: It can be concluded that the application of two consecutive adhesive layers improved bond strength to deminera-lized dentin, but no such effect was observed for sound dentin. CLINICAL SIGNIFICANCE: Application of double coats of one-step self-etching adhesive improved bond strength to demineralized dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Desmineralização do Dente/patologia , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
7.
J Clin Exp Dent ; 15(5): e403-e410, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37214755

RESUMO

Background: Greater degradation of the hybrid layer is expected when a universal adhesive system is used, especially in the conventional application strategy. Therefore, it would important to evaluate the effect of the ethanol (ETH) and a potential matrix protease inhibitor (caffeic acid phenethyl ester/ CAPE) to maximize the ability to achieve stable dentin bond strength. The aim of this study was to evaluated the effect of ETH on a wet-bonding technique, and dentin pretreatments with different concentrations of CAPE in ethanolic solution, followed by application of a universal adhesive system (Single Bond Universal) to inhibit proteolytic activity. Material and Methods: Dentin blocks were allocated to eight experimental groups according to the strategy (total-etch our self-etch) and treatments: ETH, or dentin pretreatment with CAPE (at 0.5%, 2.5%; and 5.0%). Half of each block (each hemiblock) served as the control (without dentin pretreatments) for the same group. The bonding strategy was performed (adhesive system/ restoration with composite resin). Two slices were obtained from each hemiblock and evaluated using in situ zymography. The proteolytic activity was analyzed by quantifying the green photons of the images obtained under a fluorescence microscope in three dentin locations close to the dentin-resin interface: hybrid layer (HL), underlying dentin (UD) and deep dentin (DD). Results: Wilcoxon tests (for comparison between experimental and control groups) and Friedman and Nemenyi tests (for comparisons between interface locations) showed that there was no difference between the groups with different CAPE concentrations and the respective control groups (p>0.05). ETH reduced the proteolytic activity at the HL and UD (p<0.05). Conclusions: The wet-bonding technique with ETH proved effective in reducing the proteolytic activity. The use of CAPE in different concentrations solubilized in ethanol did not have a favorable effect on proteolytic inhibition. Key words:Adhesives, Hybrid layer, Dentin, Metalloproteinases.

8.
Am J Dent ; 25(6): 332-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23409623

RESUMO

PURPOSE: To investigate the laboratory effect of Er:YAG laser on ablation rate and morphological changes in human enamel and dentin with varying water flow. METHODS: 23 human third molars were sectioned in mesio-distal and buccal-lingual directions. The slabs were flattened and weighted on an analytical laboratory balance (control). A 4-mm2 area was demarcated and the samples were randomly assigned into three groups according to water flow employed during the laser irradiation (1.0, 1.5, and 2.0 mL/minute). An Er:YAG laser was used to ablate enamel (80.22-J/cm2, 300 mJ/4Hz) and dentin (96.26-J/cm2, 250 mJ/4Hz). After irradiation, the samples were immersed in distilled water for 1 hour and then weighted again. The final mass was obtained and laser-irradiated substrate mass loss was calculated by the difference between the initial and final mass. Afterwards, specimens were prepared for SEM. RESULTS: Data were submitted to ANOVA and Tukey's test (P < 0.05). It was observed that the 2.0 mL/minute resulted in a higher mass loss, 1.0 mL/minute showed a lower mass loss, and 1.5 mL/minute demonstrated intermediate results (P < 0.05). The increase of water flow promoted less melting areas and cracks. Furthermore, dentin was more ablated than enamel. It may be concluded that the water flow of Er:YAG laser and the substrates affected the ablation rate. Among the tested parameters, 2.0 mL/minute improved the ability of ablation in enamel and dentin, with less morphologic surface alteration.


Assuntos
Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Terapia a Laser , Humanos
9.
Microsc Res Tech ; 85(5): 1884-1890, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34997799

RESUMO

Several mechanical and biological factors may change the orthodontic wire frictional resistance (FR). Titanium dioxide (TiO2 ) and silica dioxide (SiO2 ) nanoparticle (NP) coatings may be used to improve the characteristics of materials, reducing FR between archwire and bracket. This in vitro study aimed to evaluate the FR of orthodontic wires with and without coating in both dry and wet environments and measure the surface roughness (SR). One hundred and eighty segments of rectangular Cr-Ni orthodontic wires (Morelli Co, Brazil) were divided into three groups according to the NP coating applied: TiO2 group; SiO2 group; and control group. The SR parameters were measured in an optical profilometer, the surface morphology was analyzed with scanning electron microscopy (SEM), and FR was performed in a universal testing machine in dry and wet environments (n = 30). The statistical analysis was performed using the Generalized Estimated Equations model with a Bonferroni post-test (α = 0.05). It was observed that SiO2 NP coating decreased FR significantly when compared to the TiO2 and control groups, in both environments (p < .001). The SiO2 and TiO2 groups presented statistically lower SR than the control group and were similar to each other (p < .001). The SiO2 group presented the lower depth of Valley parameter than the TiO2 group (p < .001). The SEM showed that the TiO2 coating had the most heterogeneous surface morphology than the SiO2 and control groups. The orthodontic wires with NP coating modified the FR and morphology. The SiO2 coating reduced FR in both dry and wet environments and decreased SR. Titanium dioxide (TiO2 ) and silica dioxide (SiO2 ) nanoparticles coatings may be used to reduce frictional resistance (FR) between archwire and bracket as well as to improve surface morphology. The SiO2 coating reduced FR in both dry and wet environments and decreased the SR of Cr-Ni orthodontic wire. The TiO2 coating promoted the most heterogeneous surface morphology of Cr-Ni orthodontic wire.


Assuntos
Nanopartículas , Braquetes Ortodônticos , Ligas Dentárias , Fricção , Teste de Materiais , Fios Ortodônticos , Dióxido de Silício , Propriedades de Superfície , Titânio
10.
Int J Esthet Dent ; 17(1): 100-114, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35175011

RESUMO

BACKGROUND: Due to controversial results in relation to the influence of desensitizing agents on sensitivity during bleaching, the present study evaluated the degree of tooth bleaching sensitivity, color change, and patient acceptability of desensitizing agents containing potassium nitrate/sodium fluoride (PNF) or nanostructured calcium phosphate (N) associated with in-office bleaching with 35% hydrogen peroxide (HP). MATERIALS AND METHODS: Seventy-five patients were randomly distributed into three groups (n = 25): 1) Group W - in-office bleaching (Whiteness HP Maxx - three sessions of 45 min); 2) Group WD - associated with PNF desensitizing gel (Desensibilize KF 2%) applied for 10 min before each session; 3) Group WDN - associated with N desensitizing paste (Desensibilize Nano P) applied after bleaching for 5 min. The degree of sensitivity and patient acceptability of the desensitizing treatments were evaluated using a visual analog scale. Color change evaluations were made over different time intervals. RESULTS: The three groups showed no significant difference in sensitivity between the time intervals throughout the evaluation, except for the one of 24 h after the second bleaching session, in which group WD showed lower bleaching sensitivity than group W (P < 0.05; Kruskal-Wallis and Dunn tests). The use of PNF gel and N paste did not interfere with the color change during dental bleaching. CONCLUSIONS: Although the use of desensitizing agents during bleaching did not interfere with the color change during dental bleaching, it was shown that these agents were not effective in the treatment of tooth bleaching sensitivity, despite being acceptable to the patients.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/tratamento farmacológico , Humanos , Peróxido de Hidrogênio , Clareamento Dental/métodos
11.
Microsc Res Tech ; 85(1): 270-282, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34386997

RESUMO

This study evaluated the influence of Libidibia ferrea (Lf) extract used as dentin pretreatment on the resin-dentin bond strength stability and dentin endogenous enzymatic activity. The phytochemical profile (PP) of the Lf extract was evaluated by liquid chromatography; particle size, polydispersity index (PdI), and zeta potential (ZP) were evaluated by dynamic light scattering. The tested groups were ER-Scotchbond Universal (SBU) in the etch-and-rinse (ER) mode; ERLf-SBU in the ER mode + Lf after etching; SE- SBU in the self-etch (SE) mode; and LfSE-Lf before SBU in the SE mode. Sticks were obtained for microtensile bond strength tests and failure mode (24 hr and 12 months). The hybrid layer was evaluated using scanning electron microscopy. The endogenous enzymatic activity of the underlying dentin was analyzed by in situ zymography with the same treatments. The PP showed the presence of quercetin (2.6% w/w). Lf particles were considered large after the analysis of the PdI. The ZP remained stable over time. The ER and ERLf groups had lower bond strength after 12 months, but SE and LfSE remained stable. The predominant failure mode was adhesive for both times. ER and ERLf had longer resin tags and a thicker hybrid layer. The ER and LfSE groups showed higher enzymatic activity than the ERLf and SE groups after 12 months. The Lf extract may contribute to inhibit the dentin endogenous enzymatic activity when associated with an adhesive system in the ER mode.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Extratos Vegetais/farmacologia , Cimentos de Resina , Resistência à Tração
12.
Am J Dent ; 24(4): 245-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22016920

RESUMO

PURPOSE: To investigate the effect of bleaching and staining solutions on roughness and shade changes in a nanofilled resin composite [Filtek Supreme (FS)]. METHODS: FS specimens (n = 135) were light cured and separated into groups (n = 45) that were bleached with 10% carbamide peroxide (CP) agent or 16% or 35% hydrogen peroxide (HP). In the first two groups the bleaching gel was used for 4 hours a day, during 14 days, and for the third group in three sessions of 45 minutes. Each group was subdivided (n = 15) and immersed in coffee, red wine or distilled water for 3 hours a day during 40 days. The roughness values (Ra) and shade (parameter CLELab) were evaluated at baseline, after bleaching and after staining. The data was analyzed by ANOVA and Tukey test or Kruskal Wallis. RESULTS: The effects on specimens varied depending on the bleaching product and staining solution. FS after bleaching and after staining presented higher roughness. In the evaluation of shade changes after bleaching, it was observed that resin color changed and that 35% hydrogen peroxide bleached the resin more than the others. After staining in three solutions, all specimens changed color and wine showed the higher staining capacity.


Assuntos
Corantes/química , Resinas Compostas/química , Materiais Dentários/química , Nanocompostos/química , Clareadores Dentários/química , Peróxido de Carbamida , Café/química , Cor , Humanos , Umidade , Peróxido de Hidrogênio/química , Imersão , Teste de Materiais , Peróxidos/química , Propriedades de Superfície , Temperatura , Fatores de Tempo , Ureia/análogos & derivados , Ureia/química , Água/química , Vinho
13.
Am J Dent ; 23(1): 23-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20437723

RESUMO

PURPOSE: To evaluate the in vitro microtensile bond strength (microTBS) of etch-and-rinse and self-etch adhesive systems to demineralized dentin after the use of a papain-based chemomechanical method. METHODS: 36 demineralized human dentin slabs were randomly distributed into two groups according to the method of caries removal: (1). Mechanical removal with manual excavators; (2) Chemomechanical removal with a papain-based gel (Papacárie). Subsequently, three adhesive systems were applied (n=6): (a) an etch-and-rinse adhesive system (Single Bond); (b) a two-step self-etch adhesive system (AdheSE); (c) a one-step self-etch adhesive system (Adper Prompt). The slabs were restored with a microhybrid resin composite and each resin-dentin block was sectioned into 1.0 mm2 thick slabs, which were kept in receptacles containing distilled water at relative humidity, for 24 hours, at 37 degrees C. After that, they were subjected to tensile stress in a universal testing machine at a speed of 0.5 mm/minute. Data were submitted to two-way ANOVA and Tukey's test at a 0.05 level of significance. The fractured specimens were observed under a stereomicroscope to assess the failure mode. RESULTS: The application of both chemomechanical and mechanical methods on demineralized dentin yielded microTBS values that were statistically similar among them, regardless of the adhesive system used. Caries removal with a chemomechanical papain-based method did not interfere in the adhesion of the tested adhesive systems to demineralized dentin.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Dentina , Papaína , Cimentos de Resina , Resinas Acrílicas , Bis-Fenol A-Glicidil Metacrilato , Preparo da Cavidade Dentária/métodos , Análise do Estresse Dentário , Dentina/patologia , Adesivos Dentinários , Humanos , Teste de Materiais , Resistência à Tração , Desmineralização do Dente
14.
Mater Sci Eng C Mater Biol Appl ; 116: 111235, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32806286

RESUMO

The aim of this paper was to evaluate the physical properties and the long-term bond strength of a 2.5% polyphenol-enriched extract of Arrabidaea chica (AC) incorporated into both the phosphoric acid and the primer of a three-step total-etch adhesive, or into an aqueous solution as a dentin pretreatment. Fifty dentin surfaces received the treatments (n = 10): CON (control) - application of the three-step adhesive system (Adper Scotchbond Multipurpose, 3M ESPE); WAT - distilled water used as a pretreatment after dentin etching and before application of the adhesive system; ACPA - AC incorporated into the phosphoric acid; ACW - dentin pre-treatment with AC incorporated into an aqueous solution after etching; ACP - AC incorporated into the primer. Microtensile bond strength tests were performed after 24 h, 6 and 12 months of storage. Slices from the resin-dentin interface were obtained for scanning electron microscopy analysis of the hybrid layer. Degree of conversion of AC incorporated into the primer was evaluated. The particle size, polydispersity index and zeta potential of all the solutions prepared by incorporating AC (phosphoric acid, primer and distilled water) were measured by dynamic light scattering, which brought about changes after incorporation. Degree of conversion of the primer was not affected after incorporating AC. ACP showed lower microtensile bond strength values than the other groups. Bond strength decreased after 6 months of storage, stabilizing at the 12-month evaluation. Therefore, use of AC incorporated into the primer led to lower bond strength values, since AC modified the physical properties (particle size, polydispersity index and zeta potential) of the primer, but did not change the degree of conversion. Application of AC as a dentin pretreatment did not affect bond strength or the micromorphological characteristics of the hybrid layer.


Assuntos
Colagem Dentária , Adesivos Dentinários , Condicionamento Ácido do Dente , Adesivos , Resinas Compostas , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Extratos Vegetais , Polifenóis , Cimentos de Resina , Propriedades de Superfície , Resistência à Tração
15.
Lasers Med Sci ; 24(5): 811-8, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18425563

RESUMO

Since lasers were introduced in dentistry, there has been considerable advancement in technology. Several wavelengths have been investigated as substitutes for high-speed air turbine. Owing to its high absorbability in water and hydroxyapatite, the erbium:yttrium-aluminum-garnet (Er:YAG) laser has been of great interest among dental practitioners and scientists. In spite of its great potential for hard tissue ablation, Er:YAG laser effectiveness and safety is directly related to an adequate setting of the working patterns. It is assumed that the ablation rate is influenced by certain conditions, such as water content of the target tissue, and laser parameters. It has been shown that Er:YAG irradiation with water coolant attenuates temperature rise and, hence, minimizes the risk of thermally induced pulp injury. It also increases ablation efficiency and enhances adhesion to the lased dental tissue. The aim of this review was to obtain insights into the ablation process and to discuss the effects of water flow on dental tissue ablation using Er:YAG laser.


Assuntos
Lasers de Estado Sólido/uso terapêutico , Dente/cirurgia , Cárie Dentária/cirurgia , Esmalte Dentário/cirurgia , Técnica Odontológica de Alta Rotação , Polpa Dentária/lesões , Dentina/cirurgia , Humanos , Técnicas In Vitro , Lasers de Estado Sólido/efeitos adversos , Temperatura , Água
16.
J Esthet Restor Dent ; 21(4): 242-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19689722

RESUMO

UNLABELLED: The regular use of mouthrinses, particularly when combined with the use of air-powder polishing, could affect the appearance of tooth-colored restorations. The current study sought to evaluate the effect of NaHCO(3) powder on translucency of a microfilled composite resin immersed in different mouthrinses, at distinct evaluation periods. Eighty disk-shaped specimens of composite resin (Durafill VS, Heraeus Kulzer GmbH & Co. KG, Hanau, Germany) were prepared. The composite specimens were then randomly allocated into two groups according to the surface treatment: exposure to NaHCO3 powder (10 seconds) or nonexposure, and they were randomly assigned into four subgroups, according to the mouthrinses employed (N = 10): Periogard (Colgate/Palmolive, São Bernardo do Campo, SP, Brazil), Cepacol (Aventis Pharma, São Paulo, SP, Brazil), Plax (Colgate/Palmolive), and distilled water (control group). The samples were immersed for 2 minutes daily, 5 days per week, over a 4-month test period. Translucency was measured with a transmission densitometer at seven evaluation periods. Statistical analyses (analysis of variance and Tukey's test) revealed that: distilled water presented higher translucency values (86.72%); Periogard demonstrated the lowest translucency values (72.70%); and Plax (74.05%) and Cepacol (73.32%) showed intermediate translucency values, which were statistically similar between them (p > 0.01). NaHCO3 air-powder polishing increased the changes in translucency associated with the mouthrinses. Air-powder polishing alone had no effect on material translucency. Translucency percent was gradually decreased from 1 week of immersion up to 4 months. It may be concluded that the NaHCO3 powder and the tested mouthrinses have affected the translucency of microfilled composite resin, according to the tested time. CLINICAL SIGNIFICANCE: During the last decade, the demand for composite resin restorations has grown considerably, however, controversy persists regarding the effect of surface roughness on color stability.


Assuntos
Resinas Compostas , Dentifrícios , Antissépticos Bucais , Bicarbonato de Sódio , Profilaxia Dentária/métodos , Concentração de Íons de Hidrogênio , Imersão , Teste de Materiais , Antissépticos Bucais/química , Fenômenos Ópticos , Tamanho da Partícula , Distribuição Aleatória
17.
Oper Dent ; 33(1): 51-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18335733

RESUMO

This in vitro study evaluated the microtensile bond strength of a resin composite to Er:YAG-prepared dentin after long-term storage and thermocycling. Eighty bovine incisors were selected and their roots removed. The crowns were ground to expose superficial dentin. The samples were randomly divided according to cavity preparation method (I-Er:YAG laser and II-carbide bur). Subsequently, an etch & rinse adhesive system was applied and the samples were restored with a resin composite. The samples were subdivided according to time of water storage (WS)/number of thermocycles (TC) performed: A) 24 hours WS/no TC; B) 7 days WS/500 TC; C) 1 month WS/2,000 TC; D) 6 months WS/12,000 TC. The teeth were sectioned in sticks with a cross-sectional area of 1.0-mm2, which were loaded in tension in a universal testing machine. The data were subjected to two-way ANOVA, Scheffé and Fisher's tests at a 5% level. In general, the bur-prepared group displayed higher microtensile bond strength values than the laser-treated group. Based on one-month water stbrage and 2,000 thermocycles, the performance of the tested adhesive system to Er:YAG-laser irradiated dentin was negatively affected (Group IC), while adhesion of the bur-prepared group decreased only within six months of water storage combined with 12,000 thermocycles (Group IID). It may be concluded that adhesion to the Er:YAG laser cavity preparation was more affected by the methods used for simulating degradation of the adhesive interface.


Assuntos
Colagem Dentária , Preparo da Cavidade Dentária/instrumentação , Adesivos Dentinários , Dentina , Cimentos de Resina , Análise de Variância , Animais , Bis-Fenol A-Glicidil Metacrilato , Bovinos , Resinas Compostas , Instrumentos Odontológicos , Falha de Restauração Dentária , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Armazenamento de Medicamentos , Lasers de Estado Sólido , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Resistência à Tração , Água
18.
Am J Dent ; 21(2): 124-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18578182

RESUMO

PURPOSE: To evaluate in vitro the influence of water flow rate on shear bond strength of a resin composite to enamel and dentin after Er:YAG cavity preparation. METHODS: Ten bovine incisors were selected and roots removed. Crowns were sectioned in four pieces, resulting in 40 samples that were individually embedded in polyester resin (n = 10), and ground to plane the enamel and expose the dentin. The bonding site was delimited and samples were randomly assigned according to cavity preparation: (1) Er:YAG/1.0 mL/minute; (2) Er:YAG/1.5 mL/minute; (3) Er:YAG/2.0 mL/minute and (4) High speed handpiece/bur (control group). Samples were fixed to a metallic device, where composite resin cylinders were prepared. Subsequently, they were stored for 24 hours and subjected to a shear bond strength test (500N at 0.5 mm/minute). RESULTS: Means (MPa) were: enamel: 1: 12.8; 2: 16.8; 3: 17.5; 4: 36.0 and Dentin: 1: 13.6; 2: 18.7; 3: 12.1; 4: 21.3. Data were submitted to ANOVA and Tukey's test. Adhesion to enamel was more efficient than for dentin. The cavities prepared with conventional bur (control) presented higher statistically significant bond strength values (P < 0.05) than for Er:YAG laser for both enamel and dentin. No significant differences were observed between water flow rates employed during enamel ablation. For dentin, the shear bond strength of 2.0 mL/minute water flow rate was lower than for 1.5 mL/minute and 1.0 mL/minute rates. The Er:YAG laser adversely affected shear bond strength of resin composite to both enamel and dentin, regardless of the water flow rate used.


Assuntos
Resinas Compostas/química , Colagem Dentária , Preparo da Cavidade Dentária/métodos , Materiais Dentários/química , Lasers de Estado Sólido , Água/química , Condicionamento Ácido do Dente , Adesividade , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Bovinos , Preparo da Cavidade Dentária/instrumentação , Esmalte Dentário/ultraestrutura , Equipamentos Odontológicos de Alta Rotação , Dentina/ultraestrutura , Adesivos Dentinários/química , Distribuição Aleatória , Resistência ao Cisalhamento , Estresse Mecânico , Temperatura , Fatores de Tempo
19.
Dent Mater ; 33(10): 1157-1170, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28781068

RESUMO

OBJECTIVES: To evaluate the bond strength to superficial (SD) and deep (DD) dentin after the use of 2.5% (T2.5%) or 4% (T4%) titanium tetrafluoride (TiF4) in aqueous solution as a dentin pretreatment, or when incorporated into the primer (T2.5%P and T4%P) of an adhesive system (Clearfil SE Bond/CL). Degree of conversion (DC), particle size (PS), polydispersity index (PI) and zeta potential (ZP) of the solutions were evaluated. METHODS: Fifty molars were sectioned longitudinally to obtain two slices of each tooth, which were demarcated into SD and DD. Treatments were applied (n=10): CL; T2.5%; T4%; T2.5%P; T4%P. After 24h or 180days storage, microshear bond strength tests were performed. The DC values of T2.5%P and T4%P were evaluated by FTIR. PS, PI and ZP were measured using dynamic light scattering. RESULTS: Analysis of mixed models showed significant effect of concentration of TiF4 * solution * storage time (p=0.0075). There were higher bond strength values in SD than in DD (p=0.0105) for all treatments in both times. The failure mode showed adhesive failures in the majority of groups, irrespective of depth and time (p=0.3746). The bond strength values were not affected by treatments. Lower average particle size was observed for T2.5%P and T4%P at baseline. T2.5% and T4% showed a trend towards agglomeration. SIGNIFICANCE: Higher bond strength values were achieved at SD for all treatments and times. The failure modes observed were adhesive. TiF4 incorporation did not affect DC. T2.5%P and T4%P presented excellent stability over time.


Assuntos
Colagem Dentária , Dentina , Cimentos de Resina , Cimentos Dentários , Adesivos Dentinários , Fluoretos , Humanos , Teste de Materiais , Resistência à Tração , Titânio
20.
Oper Dent ; 31(2): 212-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16827024

RESUMO

This study evaluated the effect of Er:YAG laser irradiation of enamel and dentin on the shear bond strength of resin-modified glass ionomer cements (RMGIC). Twenty molars were selected and the roots removed. The crowns were bisected, embedded in polyester resin and ground to plane the enamel or expose the dentin. The bonding site was delimited, and samples were randomly assigned according to the cavity preparation device: I--Er.YAG laser (350mJ/2Hz); II--Carbide bur (control group). They were subdivided according to the restorative material employed: A) Fuji II LC (GC); B) Vitremer (3M). Samples were then fixed to a metallic device where ionomer cylinders were prepared. Sequentially, the molars were stored for 24 hours and subjected to a shear bond strength test (50Kgf at 0.5 mm/minute). Means in MPa were: Enamel--IA) 4.77 (+/- 1.12); IB) 4.36 (+/- 1.50); IIA) 7.70 (+/- 1.53); IIB) 7.34 (+/- 1.52) and Dentin--IA) 3.13 (+/- 1.15); IB) 2.67 (+/- 0.74); IIA) 6.38 (+/- 1.44); IIB) 5.58 (+/-2.09). Data were submitted to statistical analysis by ANOVA. Adhesion for enamel was more efficient than for dentin (p < 0.01). The cavities prepared with a conventional bur (control group) presented higher bond strength values than those recorded for Er:YAG laser (p < 0.01). No significant differences were observed between the restorative materials. Based on these results, it was concluded that Er:YAG laser adversely affected the shear bond strength of RMGIC for both enamel and dentin.


Assuntos
Preparo da Cavidade Dentária/métodos , Esmalte Dentário/efeitos da radiação , Dentina/efeitos da radiação , Cimentos de Ionômeros de Vidro/química , Lasers/efeitos adversos , Análise de Variância , Humanos , Dente Molar , Resistência ao Cisalhamento