Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
EMBO J ; 39(24): e106807, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33196145

RESUMO

Assembly of extracellular filaments and matrices mediating fundamental biological processes such as morphogenesis, hearing, fertilization, and antibacterial defense is driven by a ubiquitous polymerization module known as zona pellucida (ZP) "domain". Despite the conservation of this element from hydra to humans, no detailed information is available on the filamentous conformation of any ZP module protein. Here, we report a cryo-electron microscopy study of uromodulin (UMOD)/Tamm-Horsfall protein, the most abundant protein in human urine and an archetypal ZP module-containing molecule, in its mature homopolymeric state. UMOD forms a one-start helix with an unprecedented 180-degree twist between subunits enfolded by interdomain linkers that have completely reorganized as a result of propeptide dissociation. Lateral interaction between filaments in the urine generates sheets exposing a checkerboard of binding sites to capture uropathogenic bacteria, and UMOD-based models of heteromeric vertebrate egg coat filaments identify a common sperm-binding region at the interface between subunits.


Assuntos
Polímeros/química , Uromodulina/química , Zona Pelúcida/química , Sequência de Aminoácidos , Animais , Microscopia Crioeletrônica/métodos , Feminino , Humanos , Polimerização , Polímeros/metabolismo , Conformação Proteica , Domínios Proteicos , Domínios e Motivos de Interação entre Proteínas , Uromodulina/genética , Uromodulina/metabolismo , Zona Pelúcida/metabolismo
2.
Clin Oral Implants Res ; 35(4): 386-395, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38286766

RESUMO

OBJECTIVES: To assess the efficacy of dynamic computer-aided surgery (dCAS) in replacing a single missing posterior tooth, we compare outcomes when using registration-and-fixation devices positioned anterior or posterior to the surgical site. Registration is performed on either the anterior or opposite posterior teeth. METHODS: Forty individuals needing posterior single-tooth implant placement were randomly assigned to anterior or posterior registration. Nine parameters were analyzed to detect the deviations between planned and actual implant placement, using Mann-Whitney and t-tests for nonnormally and normally distributed data, respectively. RESULTS: The overall average angular deviation for this study was 2.08 ± 1.12°, with the respective average 3D platform and apex deviations of 0.77 ± 0.32 mm and 0.88 ± 0.32 mm. Angular deviation values for individuals in the anterior and posterior registration groups were 1.58°(IQR: 0.98°-2.38°) and 2.25°(IQR: 1.46°-3.43°), respectively (p = .165), with 3D platform deviations of 0.81 ± 0.29 mm and 0.74 ± 0.36 mm (p = .464), as well as 3D apex deviations of 0.89 ± 0.32 mm and 0.88 ± 0.33 mm (p = .986). No significant variations in absolute buccolingual (platform, p = .659; apex, p = .063), apicocoronal (platform, p = .671; apex, p = .649), or mesiodistal (platform, p = .134; apex, p = .355) deviations were observed at either analyzed levels. CONCLUSIONS: Both anterior and posterior registration approaches facilitate accurate dCAS-mediated implant placement for single missing posterior teeth. The device's placement (posterior-to or anterior-to the surgical site) did not affect the clinician's ability to achieve the planned implant location.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Dente , Humanos , Implantação Dentária Endóssea , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional
3.
Clin Oral Implants Res ; 35(4): 407-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38287504

RESUMO

OBJECTIVES: To study bone healing of two-wall bone defects after alveolar ridge preservation using mineralized dentin matrix. MATERIALS AND METHODS: After distal roots extraction of second and fourth premolars (P2, P4) on one lateral mandible in 12 beagles, two-wall bone defects (5 × 5 × 5 mm) were surgically created distally to the remaining mesial roots of P2 and P4. A total of 24 sites were randomly allocated to three groups (implant material- time of execution): mineralized dentin matrix (MDM)-3 m (MDM + collagen membrane; 3 months), MDM-6 m (MDM particles + collagen membrane; 6 months), and C-6 m (collagen membrane only; 6 months). Clinical, radiographic, digital, and histological examinations were performed 3 and 6 months after surgery. RESULTS: The bone healing in MDM groups were better compared to Control group (volume of bone regenerated in total: 25.12 mm3 vs. 13.30 mm3, p = .046; trabecular volume/total volume: 58.84% vs. 39.18%, p = .001; new bone formation rate: 44.13% vs. 31.88%, p = .047). Vertically, the radiological bone level of bone defect in MDM-6 m group was higher than that in C-6 m group (vertical height of bone defect: 1.55 mm vs. 2.74 mm, p = .018). Horizontally, no significant differences in buccolingual bone width were found between MDM and C groups at any time or at any level below the alveolar ridge. The percentages of remaining MDM were <1% in both MDM-3 m and MDM-6 m groups. CONCLUSIONS: MDM improved bone healing of two-wall bone defects and might be considered as a socket fill material used following tooth extraction.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Cães , Animais , Alvéolo Dental/cirurgia , Alvéolo Dental/patologia , Processo Alveolar/cirurgia , Processo Alveolar/patologia , Colágeno , Extração Dentária , Dentina , Perda do Osso Alveolar/prevenção & controle , Perda do Osso Alveolar/cirurgia , Perda do Osso Alveolar/patologia
4.
Clin Oral Investig ; 28(7): 375, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38878120

RESUMO

OBJECTIVE: To investigate the impact of mineralized dentin matrix (MDM) on the prognosis on bone regeneration and migration of retained roots after coronectomy. MATERIALS AND METHODS: Patients were divided into three groups based on the type of bone graft after coronectomy: Group C (n = 20, collagen), Group T (n = 20, tricalcium phosphate (TCP) + collagen), and Group D (n = 20, MDM + collagen). CBCT scans, conducted immediately and 6 months after surgery, were analyzed using digital software. Primary outcomes, including changes in bone defect depth and retained root migration distance, were evaluated 6 months after surgery. RESULTS: After 6 months, both Groups D and T exhibited greater reduction of the bone defect and lesser retained root migration than Group C (p < 0.001). Group D had greater regenerated bone volume in the distal 2 mm (73 mm3 vs. 57 mm3, p = 0.011) and lesser root migration (2.18 mm vs. 2.96 mm, p < 0.001) than Group T. The proportion of completely bone embedded retained roots was also greater in Group D than in Group C (70.0% vs. 42.1%, p = 0.003). CONCLUSIONS: MDM is an appropriate graft material for improving bone defect healing and reducing retained root migration after coronectomy. CLINICAL RELEVANCE: MDM is an autogenous material prepared chairside, which can significantly improve bone healing and reduce the risk of retained root re-eruption. MDM holds promise as a routine bone substitute material after M3M coronectomy.


Assuntos
Regeneração Óssea , Fosfatos de Cálcio , Colágeno , Tomografia Computadorizada de Feixe Cônico , Dentina , Humanos , Masculino , Feminino , Fosfatos de Cálcio/uso terapêutico , Prognóstico , Pessoa de Meia-Idade , Colágeno/uso terapêutico , Regeneração Óssea/efeitos dos fármacos , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/cirurgia , Adulto , Coroa do Dente/cirurgia , Resultado do Tratamento , Transplante Ósseo/métodos , Substitutos Ósseos/uso terapêutico
5.
Clin Oral Investig ; 28(8): 439, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037593

RESUMO

OBJECTIVES: To conduct a finite element analysis of the impact of different variables on tooth sectioning efficiency and trauma to surrounding tissues when utilizing high-speed surgical handpieces and elevators. METHODS: CBCT data from the horizontally impacted third mandibular molar (M3M) of a patient were utilized to establish digital models of the M3M, adjacent M2M, and surrounding bone. To simulate tooth sectioning, a 3D finite element model was established with the following variables: remaining tooth tissue thickness (1-5 mm), tooth section fissure width (1-3 mm), elevator depth in fissure (2-6 mm), elevator position (buccal, lingual, central), elevator width (2-5 mm), and application of force (rotating, levering). Using this model, the distribution of stress on the M3M and the surrounding tissue was assessed while measuring tooth sectioning efficiency and trauma to the surrounding tissue. RESULTS: Factors associated with uniform stress at the site of sectioning included thin (≤ 3 mm) remaining tooth tissue, appropriate fissure width (~ 2 mm), a wide (≥ 4 mm) elevator, and central elevator positioning. Levering the elevator yielded greater stress on the M3M than rotating force. Greater sectioning efficiency was associated with increased stress placed on the distobuccal side of M2M. CONCLUSIONS: Tooth sectioning efficiency can be improved by adjusting the high-speed surgical handpiece and elevator. However, it is important to remain attentive to the trauma to which adjacent teeth are exposed during this process. CLINICAL SIGNIFICANCE: These results offer guidance for approaches to improving operator efficiency and reducing trauma to surrounding tissues during tooth sectioning.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Análise de Elementos Finitos , Mandíbula , Dente Serotino , Dente Impactado , Humanos , Dente Serotino/cirurgia , Dente Impactado/cirurgia , Dente Impactado/diagnóstico por imagem , Mandíbula/cirurgia , Imageamento Tridimensional , Equipamentos Odontológicos de Alta Rotação , Análise do Estresse Dentário
6.
Mol Pharm ; 20(8): 4007-4020, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37427910

RESUMO

Distant metastasis of malignant tumors is considered to be the main culprit for the failure of current antitumor treatments. Conventional single treatments often exhibit limited efficacy in inhibiting tumor metastasis. Therefore, there is a growing interest in developing collaborative antitumor strategies based on photothermal therapy (PTT) and free-radical-generated photodynamic therapy (PDT), especially utilizing oxygen-independent nanoplatforms, to address this challenge. Such antitumor strategies can enhance the therapeutic outcomes by ensuring the cytotoxicity of free radicals even in the hypoxic tumor microenvironment, thereby improving the effective suppression of primary tumors. Additionally, these approaches can stimulate the production of tumor-associated antigens and amplify the immunogenic cell death (ICD) effects, potentially feasible for enhancing the therapeutic outcomes of immunotherapy. Herein, we fabricated a functional nanosystem that co-loads IR780 and 2,2'-azobis[2-(2-imidazolin-2-yl)propane]-dihydrochloride (AIPH) to realize PTT-triggered thermodynamic combination therapy via the oxygen-independent pathway for the elimination of primary tumors. Furthermore, the nanocomposites were surface-decorated with a predesigned complex peptide (PLGVRGC-anti-PD-L1 peptide, MMP-sensitive), which facilitated the immunotherapy targeting distant tumors. Through the specific recognition of matrix metalloproteinase (MMP), the sensitive segment on the obtained aNC@IR780A was cleaved. As a result, the freed anti-PD-L1 peptide effectively blocked immune checkpoints, leading to the infiltration and activation of T cells (CTLs). This nanosystem was proven to be effective at inhibiting both primary tumors and distant tumors, providing a promising combination strategy for tumor PTT/TDT/immunotherapy.


Assuntos
Nanopartículas , Fototerapia , Linhagem Celular Tumoral , Imunoterapia , Oxigênio , Peptídeos , Polímeros , Termodinâmica , Microambiente Tumoral , Humanos
7.
Macromol Rapid Commun ; 44(3): e2200650, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36350231

RESUMO

Shape memory polymers have great potential in the fields of soft robotics, injectable medical devices, and as essential materials for advanced electronic devices. Herein, light-triggered shape-memory thermoplastic polyurethane (TPU) is reported using azido TPU grafted by the photoswitchable azo compound. The trans-cis transitions of the azobenzene on the side chain of the TPU induce the recoiling of the main chain, leading to shaping memory behavior. Under UV irradiation, cis-azo allows the oriented main chain to recoil to release residual stress and realize light-triggered shape memory behavior. The facile method proposed here for the preparation of azo-functionalized TPU can provide viable opportunities for soft robotics and smart TPU applications.


Assuntos
Robótica , Materiais Inteligentes , Poliuretanos/química , Raios Ultravioleta
8.
Clin Oral Implants Res ; 34(3): 221-232, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36691811

RESUMO

OBJECTIVES: To assess the relative accuracy of manual (U-shaped tube) and automatic (two-in-one) dynamic navigation registration techniques for implant surgery performed in posterior sites missing one tooth. MATERIALS AND METHODS: This study included 58 partially edentulous patients with 58 implants, including 31 and 27 in the manual and automatic groups. Deviations between the planned and actual implant placement were assessed. RESULTS: The angular deviation in the overall study cohort was 2.54 ± 1.21°, while the 3D deviations at the implant platform and apex were 0.90 ± 0.46 mm and 1.04 ± 0.47 mm, respectively. The respective angular deviations in the manual and automatic groups were 2.82 ± 1.17° and 2.21 ± 1.19° (p > .05), while platform deviations were 0.89 ± 0.48 mm and 0.91 ± 0.45 mm (p > .05), and apex deviations were 0.99 ± 0.48 mm and 1.11 ± 0.46 mm (p > .05). No significant differences in absolute buccolingual, mesiodistal, or apicocoronal deviations were detected between these groups at either level (p > .05) nor were did deviation distributions differ in the buccolingual, mesiodistal, or apicocoronal directions at the platform or apex levels (p > .05). CONCLUSIONS: Manual and automatic dynamic navigation registration techniques can achieve excellent accuracy when placing implants in posterior sites missing a single tooth. The two-in-one automatic registration technique can reduce the amount of time and intraoperative steps necessary to complete the registration process relative to the manual U-shaped tube registration technique. Further follow-up studies are necessary to expand on these results.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Dente , Humanos , Implantação Dentária Endóssea/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador , Imageamento Tridimensional
9.
Artigo em Inglês | MEDLINE | ID: mdl-37814595

RESUMO

OBJECTIVES: To gauge the relative accuracy of the use of passive and active dynamic navigation systems when placing dental implants, and to determine how registration areas affect the performance of these systems. MATERIALS AND METHODS: Eighty implants were assigned to be placed into 40 total resin mandible models missing either the left or right first molars using either passive or active dynamic navigation system approaches. U-shaped tube registration devices were fixed in the edentulous site for 20 models each on the left or right side. Planned and actual implant positions were superimposed to assess procedural accuracy, and parameters including 3D entry deviation, angular deviation, and 3D apex deviation were evaluated with Mann-Whitney U tests and Wilcoxon signed-rank tests. RESULTS: Respective angular, entry, and apex deviation values of 1.563 ± 0.977°, 0.725 ± 0.268 mm, and 0.808 ± 0.284 mm were calculated for all included implants, with corresponding values of 1.388 ± 1.090°, 0.789 ± 0.285 mm, and 0.846 ± 0.301 mm in the active group and 1.739 ± 0.826°, 0.661 ± 0.236 mm, and 0.769 ± 0.264 mm in the passive group. Only angular deviation differed significantly among groups, and the registration area was not associated with any significant differences among groups. CONCLUSIONS: Passive and active dynamic navigation approaches can achieve comparable in vitro accuracy. Registration on one side of the missing single posterior tooth area in the mandible can complete single-tooth implantation on both sides of the posterior teeth, highlighting the promise of further clinical research focused on this topic.

10.
Orthod Craniofac Res ; 26(4): 650-659, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37036602

RESUMO

OBJECTIVES: The aims of this study were to evaluate the effect of related factors that influence orthodontic treatment time and to identify the predictors of orthodontic treatment duration in a Chinese population. MATERIALS AND METHODS: Information for 29 sociodemographic, malocclusion and orthodontic treatment characteristics was collected. Patients were divided into two groups: the duration ≤24 months group and duration >24 months group. The treatment dates of the initial visit and end of orthodontic treatment were obtained to calculate duration. The data were subjected to univariate and multivariate logistic regression modelling to quantify the association between characteristics and the treatment duration; odds ratios (ORs) and 95% confidence intervals (95% CIs) are reported. RESULTS: Of 2120 patients, 704 patients (mean age, 15.9 ± 6.0 years) were included. Age, extraction, Bolton ratio (overall), rotated teeth, overjet and crowding (lower arch) were predictors for duration. The nomogram based on predictive factors exhibited strong discrimination ability, with concordance indices of 0.755 (95% CI = 0.712-0.798) in the training cohort model and 0.717 (95% CI = 0.647-0.787) in the validation cohort model. The calibration curves for the training and validation cohorts showed that the probabilities of the nomogram agreed well with actual probabilities. CONCLUSIONS: Young age, non-extraction and severe crowding (lower arch) can increase the chance of durations of ≤24 months. Rotated teeth, excessive overjet and Bolton ratio (overall) can increase the chance of durations of >24 months.


Assuntos
Má Oclusão , Sobremordida , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Estudos Retrospectivos , Ortodontia Corretiva , Má Oclusão/terapia , Aparelhos Ortodônticos Fixos , Fatores Socioeconômicos
11.
Molecules ; 28(20)2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37894582

RESUMO

Molecularly imprinted polymers (MIPs) have gained significant attention as artificial receptors due to their low cost, mild operating conditions, and excellent selectivity. To optimize the synthesis process and enhance the recognition performance, various support materials for molecular imprinting have been explored as a crucial research direction. Yeast, a biological material, offers advantages such as being green and environmentally friendly, low cost, and easy availability, making it a promising supporting substrate in the molecular imprinting process. We focus on the preparation of different types of MIPs involving yeast and elaborate on the specific roles it plays in each case. Additionally, we discuss the advantages and limitations of yeast in the preparation of MIPs and conclude with the challenges and future development trends of yeast in molecular imprinting research.


Assuntos
Impressão Molecular , Polímeros Molecularmente Impressos , Saccharomyces cerevisiae , Polímeros/química , Polimerização
12.
Molecules ; 28(10)2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37241780

RESUMO

In this work, we designed biodegradable glycopolymers consisting of a carbohydrate conjugated to a biodegradable polymer, poly(lactic acid) (PLA), through a poly(ethylene glycol) (PEG) linker. The glycopolymers were synthesized by coupling alkyne end-functionalized PEG-PLA with azide-derivatized mannose, trehalose, or maltoheptaose via the click reaction. The coupling yield was in the range of 40-50% and was independent of the size of the carbohydrate. The resulting glycopolymers were able to form micelles with the hydrophobic PLA in the core and the carbohydrates on the surface, as confirmed by binding with the lectin Concanavalin A. The glycomicelles were ~30 nm in diameter with low size dispersity. The glycomicelles were able to encapsulate both non-polar (rifampicin) and polar (ciprofloxacin) antibiotics. Rifampicin-encapsulated micelles were much smaller (27-32 nm) compared to the ciprofloxacin-encapsulated micelles (~417 nm). Moreover, more rifampicin was loaded into the glycomicelles (66-80 µg/mg, 7-8%) than ciprofloxacin (1.2-2.5 µg/mg, 0.1-0.2%). Despite the low loading, the antibiotic-encapsulated glycomicelles were at least as active or 2-4 times more active than the free antibiotics. For glycopolymers without the PEG linker, the antibiotics encapsulated in micelles were 2-6 times worse than the free antibiotics.


Assuntos
Portadores de Fármacos , Micelas , Portadores de Fármacos/química , Antibacterianos , Rifampina , Polietilenoglicóis/química , Poliésteres/química , Carboidratos , Ciprofloxacina
13.
Int J Comput Dent ; 26(1): 49-60, 2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36825567

RESUMO

AIM: The present study aimed to develop a method for measuring 3D maxillary tooth movement during orthodontic treatment and to verify the accuracy of the method. MATERIALS AND METHODS: A 3D model analysis method was established to measure tooth movement by combining the effects of CBCT and intraoral scans. Transformation matrices were used to abstract the motion features of the teeth and translate them into translations and rotations. To test the validity and reliability of the method for clinical application, the inclination of the central incisor was measured using a 3D model analysis method and cephalometric analysis. Measurement error, correlation, and agreement between the two methods were analyzed using the Dahlberg formula, intraclass correlation coefficient, and Bland-Altman analysis, respectively. The performance of the 3D model analysis method was evaluated by monitoring the canine movement of a patient who underwent a premolar extraction. RESULTS: The measurement error was 0.58 degrees for the 3D model analysis and 2.02 degrees for the cephalometric analysis. There was no significant difference in the central incisor inclination measurements between the cephalometric and the 3D model analyses methods. A high correlation (0.974) and narrow limits of agreement (-3.55 degrees, 4.16 degrees) were obtained between the two methods. Minute movements and additional details of orthodontic tooth movements could be observed using the 3D model analysis method. CONCLUSION: The 3D model analysis method was reliable and reproducible for clinical application in monitoring the 3D maxillary tooth movement during orthodontic treatment. The trueness should be further evaluated. (Int J Comput Dent 2023;26(1): 49-0; doi: 10.3290/j.ijcd.b3818301).


Assuntos
Imageamento Tridimensional , Técnicas de Movimentação Dentária , Dente Pré-Molar , Imageamento Tridimensional/métodos , Maxila , Reprodutibilidade dos Testes , Ortodontia
14.
J Am Chem Soc ; 144(19): 8807-8817, 2022 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-35522220

RESUMO

Here, we describe the unexpected discovery of a Cu-catalyzed condensation polymerization reaction of propargylic electrophiles (CPPE) that transforms simple C3 building blocks into polydiynes of C6 repeating units. This reaction was achieved by a simple system composed of a copper acetylide initiator and an electron-rich phosphine ligand. Alkyne polymers (up to 33.8 kg/mol) were produced in good yields and exclusive regioselectivity with high functional group compatibility. Hydrogenation of the product afforded a new polyolefin-type backbone, while base-mediated isomerization led to a new type of dienyne-based electron-deficient conjugated polymer. Mechanistic studies revealed a new α-α selective Cu-catalyzed dimerization pathway of the C3 unit, followed by in situ organocopper-mediated chain-growth propagation. These insights not only provide an important understanding of the Cu-catalyzed CPPE of C3, C4, and C6 monomers in general but also lead to a significantly improved synthesis of polydiynes from simpler starting materials with handles for the incorporation of an α-end functional group.


Assuntos
Alcinos , Cobre , Catálise , Dimerização , Polimerização , Polímeros
15.
Biotechnol Bioeng ; 119(8): 2105-2114, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438195

RESUMO

EG5C-1, processive endoglucanase from Bacillus subtilis, is a typical bifunctional cellulase with endoglucanase and exoglucanase activities. The engineering of processive endoglucanase focuses on the catalytic pocket or carbohydrate-binding module tailoring based on sequence/structure information. Herein, a computational strategy was applied to identify the desired mutants in the enzyme molecule by evolutionary-coupling analysis; subsequently, four residue pairs were selected as evolutionary mutational hotspots. Based on iterative-saturation mutagenesis and subsequent enzymatic activity analysis, a superior mutant K51T/L93T has been identified away from the active center. This variant had increased specific activity from 4170 U/µmol of wild-type (WT) to 5678 U/µmol towards carboxymethyl cellulose-Na and an increase towards the substrate Avicel from 320 U/µmol in WT to 521 U/µmol. In addition, kinetic measurements suggested that superior mutant K51T/L93T had a high substrate affinity (Km ) and a remarkable improvement in catalytic efficiency (kcat /Km ). Furthermore, molecular dynamics simulations revealed that the K51T/L93T mutation altered the spatial conformation at the active site cleft, enhancing the interaction frequency between active site residues and substrate, and improving catalytic efficiency and substrate affinity. The current studies provided some perspectives on the effects of distal residue substitution, which might assist in the engineering of processive endoglucanase or other glycoside hydrolases.


Assuntos
Celulase , Aminoácidos , Bacillus subtilis/genética , Bacillus subtilis/metabolismo , Domínio Catalítico , Celulase/química , Celulose/metabolismo
16.
Environ Res ; 214(Pt 3): 114048, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35961548

RESUMO

Although the contamination of microplastics (MPs) in groundwater has been anticipated, their occurrence, distribution, and composition require further understanding. In this study, the occurrence and distributions of MPs were investigated in shallow groundwater from an important water source district in Tianjin city of northern China. The abundance, the physical morphology, the chemical composition, and the potential correlations of the determined MPs with human activities were thoroughly characterized. MPs were determined from all ten sampling sites with the abundance ranged between 17.0 ± 2.16 to 44.0 ± 1.63 n/L, revealing the ubiquitous existed MPs contamination. Based on the physical categorization, fiber (44.74%) was the most abundant shape, while blue (31.02%) and transparent (26.09%) were the most prevalent colors. The dominant size of MPs was smaller than 200 µm which accounted for 73.10%. A total of seven types of MPs were determined with polyethylene, polyethylene terephthalate, and polystyrene as the main types, of which, polypropylene showed strong positive correlations with polystyrene, indicating the possible similar sources of them. Besides, the determined MPs in groundwater were greater in areas with the high population density and strong population activity, indicating their high correlation with human activity. The study highlighted the presence of MPs in groundwater of drinking water source in northern China and provided useful information for evaluating the potential ecological effects on water quality safety and human health brought by MPs.


Assuntos
Água Potável , Água Subterrânea , Poluentes Químicos da Água , China , Monitoramento Ambiental , Humanos , Microplásticos , Plásticos , Poliestirenos , Poluentes Químicos da Água/análise
17.
Sensors (Basel) ; 22(20)2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36298126

RESUMO

The elasto-magnetic method is a promising pathway for cable force monitoring in cable-stayed bridges. Under the action of an externally applied pulsed magnetic field, both the variation in the main flux recorded by the induction coil and the localized surface magnetic field measured by the packaged magnetic sensor are typical signals for observing the elasto-magnetic effect in tensioned cables. However, the performances of the parameters extracted from the two types of elasto-magnetic signals are never strictly compared in the experiment. Meanwhile, comprehensive indicators for evaluating the ability of elasto-magnetic parameters on cable force characterization are seldom discussed. As a result, it is difficult to compare the performances of elasto-magnetic devices developed by different teams, and the pathway of seeking new parameters for cable force monitoring is obstructed. In this study, elasto-magnetic calibration experiments were performed on a cable of seven-wire steel strands to simultaneously measure the variation in the main flux and the localized surface magnetic field. Comprehensive indicators considering sensitivity, hysteresis error, and cable force resolution are proposed to examine the performances of classic elasto-magnetic parameters and new candidate ones. Through comparative study, two new parameters demonstrated outstanding ability for cable force measurement, and they are the minimum amplitude of the induced voltage and the area under the curve between two points of 3 dB height of the voltage measured by a Hall sensor. The latter is recommended for high-performance cable force monitoring from the perspective of simplicity in sensor configuration.


Assuntos
Magnetismo , Aço , Estresse Mecânico , Fenômenos Físicos , Fenômenos Magnéticos
18.
Acta Clin Croat ; 61(1): 138-144, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36398079

RESUMO

Three-dimensional printed polyetheretherketone (PEEK) extravascular stent was applied to treat a 14-year-old boy with nutcracker syndrome. Digital subtraction angiography revealed a segment of the left renal vein (LRV) with reduced contrast filling immediately before its inflow into the inferior vena cava, and high-pressure gradient. The three-dimensional reconstruction model demonstrated that the LRV and the duodenum were contracted at the aortomesenteric angle, resulting in LRV compression from the abnormal high-level duodenal compartment. When duodenum courses between the abdominal aorta and superior mesenteric artery (duodenal interposition), the LRV entrapment occurs even at <90 aortomesenteric degrees. Three-dimensional printed PEEK extravascular stent was chosen to elevate the superior mesenteric artery and lower the duodenum position, thus relieving LRV compression. This extravascular application has significant advantages over open surgery, endovascular stenting and artificial vessel procedures with expanded polytetrafluoroethylene. It provides better cellular vitality by ensuring soft tissue proliferation. By reducing external acceleration and centrifugal force, a three-dimensional printed PEEK extravascular stent reduces adverse side effects. Such a stent has a distinctive personalized design, good stiffness, and durability that allows blood vessel growth, preventing stent migration and thrombosis. Therefore, it is suitable for both adult and pediatric patients. According to the abdominal ultrasound and multi-slice computed tomography scan, the postoperative follow-up results were satisfactory one year after surgery. The patient felt well, the blood flow in the LRV was not obstructed, and the blood flow velocity was average. The external stent was in place.


Assuntos
Síndrome do Quebra-Nozes , Adulto , Masculino , Humanos , Adolescente , Criança , Síndrome do Quebra-Nozes/complicações , Síndrome do Quebra-Nozes/cirurgia , Stents/efeitos adversos , Veias Renais/cirurgia , Cetonas , Polietilenoglicóis , Impressão Tridimensional
19.
Biomacromolecules ; 22(2): 374-385, 2021 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-33356173

RESUMO

Polylactic acid (PLA) is a biodegradable thermoplastic polyester produced from natural resources. Because of its brittleness, many tougheners have been developed. However, traditional toughening methods cause either the loss of modulus and strength or the lack of degradability. In this work, we synthesized a biobased and potentially biodegradable poly(butylene 2,5-furandicarboxylate)-b-poly(ethylene glycol) (PBFEG50) copolymer to toughen PLA, with the purpose of both keeping mechanical strength and enhancing the toughness. The blend containing 5 wt % PBFEG50 exhibited about 28.5 times increase in elongation at break (5.5% vs 156.5%). At the same time, the tensile modulus even strikingly increased by 21.6% while the tensile strength was seldom deteriorated. Such a phenomenon could be explained by the stretch-induced crystallization of the BF segment and the interconnected morphology of PBFEG50 domains in PLA5. The Raman spectrum was used to identify the phase dispersion of PLA and PBFEG50 phases. As the PBFEG50 content increased, the interconnected PBFEG50 domains start to separate, but their size increases. Interestingly, tensile-induced cavitation could be clearly identified in scanning electron microscopy images, which meant that the miscibility between PLA and PBFEG50 was limited. The crystallization of PLA/PBFEG50 blends was examined by differential scanning calorimetry, and the plasticizer effect of the EG segment on the PLA matrix could be confirmed. The rheological experiment revealed decreased viscosity of PLA/PBFEG50 blends, implying the possible greener processing. Finally, potential biodegradability of these blends was proved.


Assuntos
Poliésteres , Polietilenoglicóis , Alcenos , Polímeros
20.
J Nanobiotechnology ; 19(1): 8, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407527

RESUMO

BACKGROUND: Non-Hodgkin's lymphoma (NHL) possesses great heterogeneity in cytogenetics, immunophenotype and clinical features, and chemotherapy currently serves as the main treatment modality. Although employing monoclonal antibody targeted drugs has significantly improved its overall efficacy, various patients continue to suffer from drug resistance or recurrence. Chinese medicine has long been used in the treatment of malignant tumors. Therefore, we constructed a low pH value sensitivity drug delivery system based on the cancer cell membrane modified mesoporous silica nanoparticles loaded with traditional Chinese medicine, which can reduce systemic toxicity and improve the therapeutic effect for the targeted drug delivery of tumor cells. RESULTS: Accordingly, this study put forward the construction of a nano-platform based on mesoporous silica nanoparticles (MSNs) loaded with the traditional Chinese medicine isoimperatorin (ISOIM), which was camouflaged by the cancer cell membrane (CCM) called CCM@MSNs-ISOIM. The proposed nano-platform has characteristics of immune escape, anti-phagocytosis, high drug loading rate, low pH value sensitivity, good biocompatibility and active targeting of the tumor site, blocking the lymphoma cell cycle and promoting mitochondrial-mediated apoptosis. CONCLUSIONS: Furthermore, this study provides a theoretical basis in finding novel clinical treatments for lymphoma.


Assuntos
Antineoplásicos/administração & dosagem , Membrana Celular , Portadores de Fármacos/farmacologia , Sistemas de Liberação de Medicamentos/métodos , Linfoma/tratamento farmacológico , Nanopartículas/química , Animais , Apoptose/efeitos dos fármacos , Materiais Biocompatíveis , Proliferação de Células , Modelos Animais de Doenças , Furocumarinas/farmacologia , Humanos , Medicina Tradicional Chinesa , Camundongos Nus , Espécies Reativas de Oxigênio , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA