Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Infect Chemother ; 29(6): 586-591, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36849098

RESUMO

BACKGROUND: In the context of the coronavirus disease 2019 (COVID-19) pandemic, a rapid and reliable point-of-care test is an essential tool for controlling the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In particular, an immunochromatography test (ICT) that uses saliva specimens for rapid antigen detection not only reduces the risk of secondary infections but also reduces the burden on medical personnel. METHODS: The newly developed salivary antigen test kit "Inspecter Kowa® SARS-CoV-2" is an ICT to which saliva specimens can be directly applied. We evaluated its usefulness in comparison with reverse transcription quantitative PCR (RT-qPCR) and the Espline® SARS-CoV-2 Kit for the detection of SARS-CoV-2 using nasopharyngeal swab specimens. In this study, 140 patients with suspected symptomatic COVID-19 who visited our hospital were enrolled, and nasopharyngeal swab and saliva specimens were collected after they consented to participate in the study. RESULTS: Inspector Kowa SARS-CoV-2 was positive in 45 of 61 (73.8%) saliva that were positive by RT-qPCR and the Espline® SARS-CoV-2 Kit was also positive in 56 of 60 (93.3%) Np swabs that were positive by RT-qPCR. Good antigen detection was achieved by ICT with saliva and nasopharyngeal swab specimens when viral load was ≥105 copies/mL, whereas detection sensitivity was low when viral load was <105 copies/mL, especially in saliva specimens. CONCLUSION: This ICT for the detection of SARS-CoV-2 salivary antigen is an attractive tool that does not require specialized equipment and allows patients to perform the entire process from sample collection to self-diagnose and to reduce the burden on medical care during a pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Técnicas de Laboratório Clínico/métodos , Manejo de Espécimes/métodos , Nasofaringe
2.
BMC Med ; 20(1): 406, 2022 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-36280827

RESUMO

BACKGROUND: The diagnostic accuracy of unsupervised self-testing with rapid antigen diagnostic tests (Ag-RDTs) is mostly unknown. We studied the diagnostic accuracy of a self-performed SARS-CoV-2 saliva and nasal Ag-RDT in the general population. METHODS: This large cross-sectional study consecutively included unselected individuals aged ≥ 16 years presenting for SARS-CoV-2 testing at three public health service test sites. Participants underwent molecular test sampling and received two self-tests (the Hangzhou AllTest Biotech saliva self-test and the SD Biosensor nasal self-test by Roche Diagnostics) to perform themselves at home. Diagnostic accuracy of both self-tests was assessed with molecular testing as reference. RESULTS: Out of 2819 participants, 6.5% had a positive molecular test. Overall sensitivities were 46.7% (39.3-54.2%) for the saliva Ag-RDT and 68.9% (61.6-75.6%) for the nasal Ag-RDT. With a viral load cut-off (≥ 5.2 log10 SARS-CoV-2 E-gene copies/mL) as a proxy of infectiousness, these sensitivities increased to 54.9% (46.4-63.3%) and 83.9% (76.9-89.5%), respectively. For the nasal Ag-RDT, sensitivities were 78.5% (71.1-84.8%) and 22.6% (9.6-41.1%) in those symptomatic and asymptomatic at the time of sampling, which increased to 90.4% (83.8-94.9%) and 38.9% (17.3-64.3%) after applying the viral load cut-off. In those with and without prior SARS-CoV-2 infection, sensitivities were 36.8% (16.3-61.6%) and 72.7% (65.1-79.4%). Specificities were > 99% and > 99%, positive predictive values > 70% and > 90%, and negative predictive values > 95% and > 95%, for the saliva and nasal Ag-RDT, respectively, in most analyses. Most participants considered the self-performing and result interpretation (very) easy for both self-tests. CONCLUSIONS: The Hangzhou AllTest Biotech saliva self Ag-RDT is not reliable for SARS-CoV-2 detection, overall, and in all studied subgroups. The SD Biosensor nasal self Ag-RDT had high sensitivity in individuals with symptoms and in those without prior SARS-CoV-2 infection but low sensitivity in asymptomatic individuals and those with a prior SARS-CoV-2 infection which warrants further investigation.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Estudos Transversais , Teste para COVID-19 , Saliva , Sensibilidade e Especificidade , Antígenos Virais
3.
J Infect Chemother ; 27(7): 1058-1062, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33934920

RESUMO

INTRODUCTION: Rapid antigen detection (RAD) tests are convenient tools for detecting the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in clinics, and testing using saliva samples could decrease the risk of infection during sample collection. This study aimed to assess the accuracy of the SARS-CoV-2 RAD for testing of nasopharyngeal swab specimens and saliva samples in comparison with the RT-PCR tests and viral culture for detecting viable virus. METHODS: One hundred seventeen nasopharyngeal swab specimens and 73 saliva samples with positive results on RT-PCR were used. Residual samples were assayed using a commercially available RAD test immediately, and its positivity was determined at various time points during the clinical course. The concordance between 54 nasopharyngeal swab samples and saliva samples that were collected simultaneously was determined. Viral culture was performed on 117 samples and compared with the results of the RAD test. RESULTS: The positive rate of RAD test using saliva samples was low throughout the clinical course. Poor concordance was observed between nasopharyngeal swab specimens and saliva samples (75.9%, kappa coefficient 0.310). However, a substantially high concordance between the RAD test and viral culture was observed in both nasopharyngeal swab specimens (86.8%, kappa coefficient 0.680) and saliva samples (95.1%, kappa coefficient 0.643). CONCLUSIONS: The sensitivity of the SARS-CoV-2 RAD test was insufficient, particularly for saliva samples. However, a substantially high concordance with viral culture suggests its potential utility as an auxiliary test for estimating SARS-CoV-2 viability.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Nasofaringe , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Saliva
4.
J Infect Chemother ; 27(6): 915-918, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33676843

RESUMO

INTRODUCTION: The rapid and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is required to prevent the spread of COVID-19. This study evaluated the utility of two SARS-CoV-2 antigen detection methods. METHODS: We evaluated two types of antigen detection methods using immunochromatography (Espline) and quantitative chemiluminescent enzyme immunoassay (Lumipulse). RT-PCR was performed as a standard procedure for COVID-19 diagnosis. Lumipulse and RT-PCR were performed for all 486 nasopharyngeal swabs and 136 saliva samples, and the Espline test was performed for 271 nasopharyngeal swabs and 93 saliva samples. RESULTS: The sensitivity and specificity of the Espline test were 10/11 and 260/260 (100%), respectively for the nasopharyngeal swabs and 3/9 and 84/84 (100%), respectively for the saliva samples. High sensitivities for both saliva (8/9) and nasopharyngeal swabs (22/24) were observed in the Lumipulse test. The specificities of the Lumipulse test for nasopharyngeal swabs and saliva samples were 460/462 (99.6%) and 123/127 (96.9%), respectively. CONCLUSION: The Espline test is not effective for saliva samples but is useful for simple and rapid COVID-19 tests using nasopharyngeal swabs because it does not require special devices. The Lumipulse test is a powerful high-throughput tool for COVID-19 diagnosis because it has high detection performance for nasopharyngeal swabs and saliva samples.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Cromatografia de Afinidade , Técnicas Imunoenzimáticas , Medições Luminescentes , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos Virais/isolamento & purificação , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Saliva/virologia , Adulto Jovem
5.
Bioelectrochemistry ; 156: 108619, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38128441

RESUMO

Herein, we developed a new waste solution-free paper-based electrochemical immunosensor for SARS-CoV-2 detection in saliva, by combining vertical and lateral flow. In detail, the device was constituted of a reservoir containing all reagents for the construction of the immunological chain onto the magnetic beads and a lateral flow holder which contained a polyester-based electrode, a magnet, and an adsorbent pad. The measurement was carried out by adding the saliva sample into the reservoir, followed by the addition of this solution in the hole present in the lateral flow holder. The successive additions of washing buffer and TMB solution in the lateral flow holder allowed the detection of N protein in saliva in the range of 0.06 to 4 µg/mL with a detection limit equal to 30 ng/mL. The analysis of several saliva samples with the sensing tool and the reference method, demonstrated the effectiveness of this device, being able to identify positive patients with high values of CT e.g. 35. This new configuration paves the way for the realization of any magnetic beads-based immunosystem without waste solution production, enlarging the application of paper-based devices.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , Saliva , SARS-CoV-2 , Imunoensaio/métodos , Técnicas Biossensoriais/métodos , Smartphone , COVID-19/diagnóstico , Limite de Detecção , Técnicas Eletroquímicas/métodos , Eletrodos
6.
Vet Res Commun ; 47(4): 1915-1924, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37222940

RESUMO

Foot-and-mouth disease (FMD) is endemic in India with a majority of outbreaks caused by FMD virus (FMDV) serotype O. In the present study a panel of eight (2F9, 2G10, 3B9, 3H5, 4C8, 4D6, 4G10 and 5B6) mouse monoclonal antibodies (MAbs) were developed against FMDV serotype O Indian vaccine strain, O/IND/R2/75 via hybridoma systems. The MAbs generated were FMDV/O specific without cross-reactivity against FMDV type A and Asia 1. All the MAbs were identified as IgG1/kappa type. Out of eight, three MAbs (3B9, 3H5 and 4G10) demonstrated virus neutralizing activity. The reactivity of all MAbs increased with heat treated (@560C) serotype O antigen compared to untreated antigen in sandwich ELISA indicating that their binding epitopes are linear. Six MAbs (except 2F9 and 4D6) reacted with recombinant P1 protein of homologous virus in an indirect ELISA among which only MAb 3B9 bound to VP1. MAb profiling of 37 serotype O field viruses isolated between the years 1962 and 2021 demonstrated antigenic similarity between field isolates and reference vaccine strain. MAbs 5B6 and 4C8 consistently reacted with all 37 isolates. In indirect immunofluorescence assay MAb 5B6 bound well with FMDV/O antigen. Finally, a sandwich ELISA was successfully developed using rabbit polyclonal anti-FMDV/O serum and MAb 5B6 for detection of FMDV/O antigen in clinical samples (n = 649). The new assay exhibited 100% and 98.89% diagnostic sensitivity and specificity respectively compared to traditional polyclonal antibody-based sandwich ELISA suggesting that the MAb-based ELISA developed here could be an effective method for detection of FMDV serotype O.


Assuntos
Vírus da Febre Aftosa , Febre Aftosa , Vacinas , Camundongos , Animais , Coelhos , Anticorpos Monoclonais , Sorogrupo , Antígenos O , Febre Aftosa/diagnóstico , Ensaio de Imunoadsorção Enzimática/veterinária , Anticorpos Antivirais
7.
Biosens Bioelectron ; 200: 113909, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-34995838

RESUMO

Coronavirus disease 2019 (COVID-19) has been recognized as a global pandemic outbreak, opening the most severe socio-economic crisis since World War II. Different scientific activities have been emerged in this global scenario, including the development of innovative analytical tools to measure nucleic acid, antibodies, and antigens in the nasopharyngeal swab, serum, and saliva for prompt identification of COVID-19 patients and to evaluate the immune response to the vaccine. The detection of SARS-CoV-2 in saliva remains a challenge for the lack of sufficient sensitivity. To address this issue, we developed a novel paper-based immunoassay using magnetic beads to support the immunological chain and 96-well wax-printed paper plate as a platform for color visualization by using a smartphone combined with Spotxel free-charge app. To assess the reliability of the measurement of SARS-CoV-2 in saliva, untreated saliva was used as a specimen and the calibration curve demonstrated a dynamic range up to 10 µg/mL, with a detection limit equal to 0.1 µg/mL. The effectiveness of this sustainable analytical tool in saliva was evaluated by comparing the data with the nasopharyngeal swab specimens sampled by the same patients and tested with Real-Time PCR reference method, founding 100% of agreement, even in the case of high Cycle Threshold (CT) numbers (low viral load). Furthermore, the positive saliva samples were characterized by the next-generation sequencing method, demonstrating the capability to detect the Delta variant, which is actually (July 2021) the most relevant variant of concern.


Assuntos
Técnicas Biossensoriais , COVID-19 , Colorimetria , Humanos , Imunoensaio , Fenômenos Magnéticos , Nasofaringe , Reprodutibilidade dos Testes , SARS-CoV-2 , Saliva , Smartphone , Manejo de Espécimes
8.
J Virol Methods ; 275: 113736, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31669454

RESUMO

A silver amplification immunochromatography (SAI) kit for the detection of all seven serotypes of foot-and-mouth disease virus (FMDV)-FMDV-Ag SAI-was developed using the monoclonal antibody 1H5 recognizing the highly conserved N terminus region of VP2. The FMDV-Ag SAI can be used under conditions of high biosecurity containment as it does not require any apparatus. The FMDV-Ag SAI exhibited 10-100 times higher sensitivity against the five serotypes (O, A, Asia1, C, and SAT1) and similar sensitivity against SAT2 and SAT3, compared with the Svanodip® FMDV-Ag kit immunochromatography kit. The Svanodip kit showed inhibitory results with several saliva samples but not with the FMDV-Ag SAI kit. In a validation study using clinical samples (n = 132; vesicular epithelium = 92, vesicular lesion swabs = 20, saliva = 20) in Mongolia, the sensitivity of FMDV-Ag SAI in comparison with real-time reverse transcription-polymerase chain reaction revealed the following data: vesicular epithelium, 85.4% (76/89); vesicular lesion swab, 46.7% (7/17); and saliva, 36.8% (7/19). No cross-reactivity with the non-FMDV vesicular-forming viruses and taxonomically related viruses of the Picornaviridae family occurred. The FMDV-Ag SAI is a highly sensitive diagnostic tool that enables pen-side diagnosis without requiring the use of any equipment.


Assuntos
Antígenos Virais/isolamento & purificação , Cromatografia de Afinidade/instrumentação , Vírus da Febre Aftosa/isolamento & purificação , Kit de Reagentes para Diagnóstico , Prata/química , Animais , Bovinos , Doenças dos Bovinos/diagnóstico , Linhagem Celular , Febre Aftosa/diagnóstico , Vírus da Febre Aftosa/classificação , Sensibilidade e Especificidade , Sorogrupo
9.
Biomaterials ; 64: 2-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26102329

RESUMO

This paper reports a new and general in situ methodology to grow fluorescent polymer conjugates from the interchain disulfide bridging sites of a monoclonal antibody. Atom transfer radical polymerization (ATRP) initiators were attached to a monoclonal antibody at its interchain disulfide bridging sites by disulfide re-bridging to yield a macroinitiator. Subsequent in situ ATRP of PEG-like monomers with dye-functionalized monomers from the macroinitiator formed antibody-polymer-dye conjugates with site-selectivity and tunable dye-to-antibody ratios. Notably, these conjugates can amplify antigen detection signal by reducing label-density dependent fluorescence quenching and by increasing dye-to-antibody ratios. The method developed may be applicable to a variety of antibodies, dyes and drugs to create a number of antibody-polymer-dye/drug conjugates for advanced diagnosis and therapy of diseases.


Assuntos
Anticorpos Monoclonais/química , Reações Antígeno-Anticorpo , Dissulfetos/química , Corantes Fluorescentes/análise , Imunoconjugados/química , Metacrilatos/química , Polietilenoglicóis/química , Rodaminas/análise , Animais , Afinidade de Anticorpos , Sítios de Ligação de Anticorpos , Cisteína/química , Cistina/química , Técnica Direta de Fluorescência para Anticorpo , Corantes Fluorescentes/química , Humanos , Camundongos , Células NIH 3T3 , Conformação Proteica , Receptor ErbB-2/análise , Receptor ErbB-2/imunologia , Rodaminas/química , Espectrometria de Massas em Tandem , Trastuzumab/química , Trastuzumab/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA