Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Surg Radiol Anat ; 40(1): 31-37, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28828519

RESUMO

PURPOSE: Advanced imaging modalities, such as multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT), greatly facilitate diagnostic medicine. In radiological research, it is important to know how accurately a scanned object is visualized, and whether the methodology leads to image distortion. The objective of this study was to evaluate whether formalin fixation impacted the accuracy of virtual 3D bone models generated via CBCT and MSCT using a software-based evaluation method that excluded human measurement errors. METHODS: A head specimen, with and without formalin preservation, was subjected to MSCT and CBCT scans using the manufacturers' predefined scanning protocols. Digital models of the lower jaw were constructed and superimposed with a master model generated based on optical scanning with an industrial non-contact scanner. Means and standard deviations were calculated to assess accuracy, and a t test was used for comparisons between the fixed and unfixed specimens. RESULTS: The extent of discrepancy between the fixed and unfixed specimens was analyzed using a total of 200 points (n = 200) in each specimen state. The mean deviation between states was 0.01 mm for MSCT (at both 80 and 140 kV). Mean values from CBCT at 0.4 voxel did not differ between states. CONCLUSIONS: Our results suggest that formalin fixation of an anatomical specimen does not substantially affect the accuracy of a three-dimensional image generated with CBCT and MSCT. Thus, fixed specimen can be used in future investigations of 3D models without concerns regarding the accuracy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fixadores , Formaldeído , Tomografia Computadorizada Multidetectores , Fixação de Tecidos , Humanos
2.
Med Sci Law ; 58(1): 58-61, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29363384

RESUMO

Dental injuries, especially of the incisors, caused by punches in violent criminal attacks could be seen in daily forensic casework involving the identification of injuries to a living body. Sometimes, when there is neither circumstantial evidence nor information about the surrounding circumstances, it is difficult to discern the cause of these injuries and the manner in which they were inflicted. As an example of clinical forensic medicine, we present the case of a 58-year-old woman whose teeth were injured when fighting with her son-in-law over household affairs with no witnesses present. The two parties had conflicting stories about the cause of the woman's injury. The woman claimed that her teeth were lost while she was being beaten by her son-in-law, and the man argued that the damage to his mother-in-law's teeth was self-inflicted when she bit his fingers. The police attending the crime called for a forensic examination. Forensic practitioners analysed the mechanism of the tooth loss using multi-slice spiral computed tomography (MSCT) and imaging reconstruction technology. Local alveolar bone (medial alveolar) fracture and a small area of alveolar bone loss were found on MSCT. Thus, forensic medical experts speculated that the woman's lower central and lateral incisors were lost as a result of a violent attack and were not self-inflicted. Finally, forensic practitioners helped police in avoiding a miscarriage of justice and wrongful conviction.


Assuntos
Perda do Osso Alveolar/diagnóstico por imagem , Processo Alveolar/diagnóstico por imagem , Processo Alveolar/lesões , Fraturas Maxilomandibulares/diagnóstico por imagem , Abuso Físico , Perda do Osso Alveolar/etiologia , Feminino , Medicina Legal , Humanos , Fraturas Maxilomandibulares/etiologia , Pessoa de Meia-Idade , Tomografia Computadorizada Espiral
3.
Dentomaxillofac Radiol ; 46(6): 20160418, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28306334

RESUMO

OBJECTIVES: To assess the impact of supine, prone and oblique patient imaging positions on the image quality, contrast-to-noise ratio (CNR) and figure of merit (FOM) value in the maxillofacial region using a CBCT scanner. Furthermore, the CBCT supine images were compared with supine multislice CT (MSCT) images. METHODS: One fresh frozen cadaver head was scanned in prone, supine and oblique imaging positions using a mobile CBCT scanner. MSCT images of the head were acquired in a supine position. Two radiologists graded the CBCT and MSCT images at ten different anatomical sites according to their image quality using a six-point scale. The CNR and FOM values were calculated at two different anatomical sites on the CBCT and MSCT images. RESULTS: The best image quality was achieved in the prone imaging position for sinus, mandible and maxilla, followed by the supine and oblique imaging positions. 12-mA prone images presented high delineation scores for all anatomical landmarks, except for the ear region (carotid canal), which presented adequate to poor delineation scores for all studied head positions and exposure parameters. The MSCT scanner offered similar image qualities to the 7.5-mA supine images acquired using the mobile CBCT scanner. The prone imaging position offered the best CNR and FOM values on the mobile CBCT scanner. CONCLUSIONS: Head positioning has an impact on CBCT image quality. The best CBCT image quality can be achieved using the prone and supine imaging positions. The oblique imaging position offers inadequate image quality except in the sinus region.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Cabeça/diagnóstico por imagem , Posicionamento do Paciente/métodos , Cadáver , Humanos , Decúbito Ventral , Decúbito Dorsal
4.
J Orofac Orthop ; 77(3): 176-84, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27103014

RESUMO

OBJECTIVES: To evaluate patients with oculoauriculovertebral spectrum (OAVS) malformations based on Katsumata's asymmetry index and to assess the usefulness of the scores thus obtained in identifying degrees and sites of asymmetry. METHODS: Multislice spiral computed tomography (MSCT) datasets of 8 female and 12 male OAVS patients aged 5.7-23.9 years were retrospectively analyzed. After three-dimensional reconstruction, central and bilateral anatomical landmarks were identified within a coordinate system defined by the sella, nasion, and dens axis. MSCT datasets of 20 clinically symmetrical patients were used to define the cutoff values for asymmetry. Based on the mean asymmetry scores and their standard deviations, the severities and sites of asymmetry were evaluated and processed for visual presentation in charts. RESULTS: Both interrater (ICC 0.7070-0.9984) and intrarater (FVU 0.0014-0.2930) reliability was very high. The calculated asymmetry scores added up to mean values and standard deviations that were higher by factors of around 1.5-2.5 than reported by Katsumata et al. More anatomical landmarks were rated as asymmetric in OAVS patients showing unilateral agenesis of an external acoustic pore than in OAVS patients without such agenesis: in the former patients, statistically significant asymmetries compared to the control group were present at the L1M (coronal pulp cavity of the lower first molar), CoP (coronoid process), and Co (condylion superius) landmarks, whereas the latter group showed such significant asymmetries at the CoP and Co landmarks. Likewise, more patients with unilateral agenesis showed asymmetries at the level of the maxilla. Highly variable severities of asymmetry were found in both subgroups of OAVS patients. CONCLUSION: Katsumata's asymmetry index can yield well-structured and illustrative views of landmark distribution, thus, suitably allowing for qualitative asymmetry evaluation of OAVS cases and identification of the skeletal regions involved.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Síndrome de Goldenhar/classificação , Síndrome de Goldenhar/diagnóstico por imagem , Imageamento Tridimensional/métodos , Índice de Gravidade de Doença , Tomografia Computadorizada Espiral/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Dentária/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
J Craniomaxillofac Surg ; 44(5): 632-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27017101

RESUMO

OBJECTIVES: Multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) are indispensable imaging techniques in advanced medicine. The possibility of creating virtual and corporal three-dimensional (3D) models enables detailed planning in craniofacial and oral surgery. The objective of this study was to evaluate the impact of different scan protocols for CBCT and MSCT on virtual 3D model accuracy using a software-based evaluation method that excludes human measurement errors. MATERIAL AND METHODS: MSCT and CBCT scans with different manufacturers' predefined scan protocols were obtained from a human lower jaw and were superimposed with a master model generated by an optical scan of an industrial noncontact scanner. To determine the accuracy, the mean and standard deviations were calculated, and t-tests were used for comparisons between the different settings. RESULTS: Averaged over 10 repeated X-ray scans per method and 19 measurement points per scan (n = 190), it was found that the MSCT scan protocol 140 kV delivered the most accurate virtual 3D model, with a mean deviation of 0.106 mm compared to the master model. Only the CBCT scans with 0.2-voxel resolution delivered a similar accurate 3D model (mean deviation 0.119 mm). CONCLUSION: Within the limitations of this study, it was demonstrated that the accuracy of a 3D model of the lower jaw depends on the protocol used for MSCT and CBCT scans.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Simulação por Computador , Humanos , Software
6.
J Dent ; 42(4): 460-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24412585

RESUMO

AIM: Today Cone Beam Computed Tomography (CBCT) has become an important image technique for dento-maxilla facial applications. In the paper a new method to assess the geometric accuracy of these systems was proposed. It uses a free form benchmark model and a non-contact Reverse Engineering (RE) system. METHOD: The test geometry chosen for this study was designed in such a way that it simulated human spongy bone, cortical bone, gingiva and teeth and it composed of removable free form parts. It was acquired with a high-resolution laser scanner (D700 Scanner - 3Shape, Denmark). The reference 3D surface models obtained with the laser scanner was compared with the 3D models that were created from a CBCT system (Scanora 3D - Soderex, Finland) and from a traditional Multi-Slice Computed Tomography (MSCT) scanner (LightSpeed VCT 64 Slice - General Electric, USA) at different reconstruction settings, using an iterative closest point algorithm (ICP) in Geomagic(®) software. RESULTS: The comparison between the different pairs of CAD models clearly shows that there is a good overlap between the models. CONCLUSIONS: Although the results obtained in this study could lead to increase the use of CBCT for an increasing number of dental procedures, the publication of the European Commission guidelines represents a baseline on which the clinicians should rely heavily when considering the use of CBCT in their practice. CLINICAL SIGNIFICANCE: The results of this research show that the accuracy of CBCT 3D models is comparable to MSCT 3D models.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Algoritmos , Benchmarking/estatística & dados numéricos , Osso e Ossos/diagnóstico por imagem , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/instrumentação , Esmalte Dentário/diagnóstico por imagem , Dentina/diagnóstico por imagem , Engenharia/estatística & dados numéricos , Gengiva/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/métodos , Lasers , Modelos Anatômicos , Tomografia Computadorizada Multidetectores/instrumentação , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Dente/diagnóstico por imagem
7.
JACC Cardiovasc Interv ; 7(1): 89-99, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24139932

RESUMO

OBJECTIVES: This study sought to perform clinical and imaging assessments of the DESolve Bioresorbable Coronary Scaffold (BCS). BACKGROUND: BCS, which is drug eluting, may have potential advantages compared with conventional metallic drug-eluting stents. The DESolve system, designed to provide vessel support and neointimal suppression, combines a poly-l-lactic acid-based scaffold with the antiproliferative myolimus. METHODS: The DESolve First-in-Man (a non-randomized, consecutive enrollment evaluation of the DESolve myolimus eluting bioresorbable coronary stent in the treatment of patients with de novo native coronary artery lesions) trial was a prospective multicenter study enrolling 16 patients eligible for treatment. The principal safety endpoint was a composite of cardiac death, myocardial infarction, and clinically indicated target lesion revascularization. The principal imaging endpoint was in-scaffold late lumen loss (LLL) assessed by quantitative coronary angiography (QCA) at 6 months. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) imaging was performed at baseline and 6 months; multislice computed tomography (MSCT) was performed at 12 months. RESULTS: Acute procedural success was achieved in 15 of 15 patients receiving a study scaffold. At 12 months, there was no scaffold thrombosis and no major adverse cardiac events directly attributable to the scaffold. At 6 months, in-scaffold LLL (by QCA) was 0.19 ± 0.19 mm; neointimal volume (by IVUS) was 7.19 ± 3.56%, with no evidence of scaffold recoil or late malapposition. Findings were confirmed with OCT and showed uniform, thin neointimal coverage (0.12 ± 0.04 mm). At 12 months, MSCT demonstrated excellent vessel patency. CONCLUSIONS: This study demonstrated the feasibility and efficacy of the DESolve BCS. Results showing low in-scaffold LLL, low % neointimal volume at 6 months, no chronic recoil, and maintenance of lumen patency at 12 months prompt further study. (DESolve First-in-Man; EudraCT number 2011-000027-32).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Imagem Multimodal , Intervenção Coronária Percutânea/instrumentação , Alicerces Teciduais , Idoso , Idoso de 80 Anos ou mais , Bélgica , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Feminino , Humanos , Ácido Láctico/química , Masculino , Teste de Materiais , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores , Imagem Multimodal/métodos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Neointima , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Poliésteres , Polímeros/química , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular
8.
JACC Cardiovasc Interv ; 6(10): 999-1009, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24156961

RESUMO

OBJECTIVES: This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California). BACKGROUND: Multimodality imaging of the first-in-humans trial using a ABSORB BVS scaffold demonstrated at 2 years the bioresorption of the device while preventing restenosis. However, the long-term safety and efficacy of this therapy remain to be documented. METHODS: In the ABSORB cohort A trial (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation), 30 patients with a single de novo coronary artery lesion were treated with the fully resorbable everolimus-eluting Absorb scaffold at 4 centers. As an optional investigation in 3 of the 4 centers, the patients underwent multislice computed tomography (MSCT) angiography at 18 months and 5 years. Acquired MSCT data were analyzed at an independent core laboratory (Cardialysis, Rotterdam, the Netherlands) for quantitative analysis of lumen dimensions and was further processed for calculation of fractional flow reserve (FFR) at another independent core laboratory (Heart Flow, Redwood City, California). RESULTS: Five-year clinical follow-up is available for 29 patients. One patient withdrew consent after 6 months, but the vital status of this patient remains available. At 46 days, 1 patient experienced a single episode of chest pain and underwent a target lesion revascularization with a slight troponin increase after the procedure. At 5 years, the ischemia-driven major adverse cardiac event rate of 3.4% remained unchanged. Clopidogrel was discontinued in all but 1 patient. Scaffold thrombosis was not observed in any patient. Two noncardiac deaths were reported, 1 caused by duodenal perforation and the other from Hodgkin's disease. At 5 years, 18 patients underwent MSCT angiography. All scaffolds were patent, with a median minimal lumen area of 3.25 mm(2) (interquartile range: 2.20 to 4.30). Noninvasive FFR analysis was feasible in 13 of 18 scans, which yielded a median distal FFR of 0.86 (interquartile range: 0.82 to 0.94). CONCLUSIONS: The low event rate at 5 years suggests sustained safety after the implantation of a fully bioresorbable Absorb everolimus-eluting scaffold. Noninvasive assessment of the coronary artery with an option of functional assessment could be an alternative to invasive imaging after treatment of coronary narrowing with such a polymeric bioresorbable scaffold. (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation [ABSORB]; NCT00300131).


Assuntos
Materiais Biocompatíveis , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Tomografia Computadorizada Multidetectores , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Europa (Continente) , Everolimo , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA