Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 520
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(20): 4491-4501, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38877148

RESUMO

In the present study, click chemistry and Schiff base reactions were simultaneously applied to prepare polymer brush (PEG)-functionalized MOF materials (UiO-66-NH2) and immobilized with Ti4+ (MOF-Brush-THBA-Ti4+) for phosphopeptide analysis. The material has a detection limit of 0.5 fmol, a selectivity of 2000:1, and a loading capacity of 133 mg/g for phosphopeptides. It also demonstrated great repeatability (10 cycles) and recovery rate (96.7 ± 1.4%). During the analysis of bio-samples, 4 specific phosphopeptides were identified in endogenous breast cancer serum, while 11 phosphopeptides were identified in skimmed milk. Moreover, 47 phosphopeptides correlated with 29 phosphorylated proteins were selectively identified from normal control serum, and 66 phosphopeptides correlated with 26 phosphorylated proteins were identified from breast cancer serum. Further analysis of gene ontology (GO) revealed that the detected phosphorylated proteins associated with breast cancer included positive regulation of receptor-mediated endocytosis, proteolysis, extracellular exosome, heparin binding, and chaperone binding. These findings suggest that these associated pathways might contribute to the etiology of breast cancer. Overall, this application exhibits enormous potential in the identification of phosphorylated peptides within bio-samples.


Assuntos
Estruturas Metalorgânicas , Leite , Fosfopeptídeos , Titânio , Zircônio , Humanos , Fosfopeptídeos/sangue , Fosfopeptídeos/química , Titânio/química , Zircônio/química , Estruturas Metalorgânicas/química , Leite/química , Animais , Polímeros/química , Feminino , Neoplasias da Mama/sangue , Limite de Detecção , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-39056305

RESUMO

OBJECTIVE: To assess the clinical, radiographic and patient-reported outcomes (PROMs) of posterior zirconia and titanium implants at 1 year of implant loading. MATERIALS AND METHODS: Forty-two patients with two adjacent missing teeth were enrolled in a randomized controlled trial with a within-subject controlled design. Each patient received one zirconia (Zr) and one titanium (Ti) implant, with the mesial and distal positions randomized. The implant restoration consisted of multiple layered zirconia, with the buccal aspect veneered. In group Zr, the restoration was intraorally cemented onto the one-piece Zr implant, whereas in group Ti, the restoration was extraorally cemented onto the titanium base abutment and intraorally screw-retained onto the Ti implant. Examinations were performed following restoration delivery at baseline (BL) and at 1 year. Measurements included clinical parameters, radiographic outcomes (MBL) and PROMs. RESULTS: Bleeding on probing showed an increase from BL to 1 year (34 ± 30% for Zr; 25 ± 21% for Ti). MBL remained stable with minimal changes from BL to 1 year, measuring 0.1 ± 0.4 mm (mean ± SD) for Zr and -0.1 ± 0.7 mm for Ti. Veneering fractures were the most frequent technical complication and amounted to 17.5% in group Zr and 5% in group Ti (p = .100). Patients preferred Zr implants for their soft tissue color, with a significant difference in perception between patients and clinicians (p < .017). CONCLUSION: The study showed that both Zr and Ti implants had similar clinical outcomes, despite a high prevalence of mucositis and a few technical complications. Both implant types demonstrated stable marginal bone levels and similar patient-reported outcome measures.

3.
Artigo em Inglês | MEDLINE | ID: mdl-39072795

RESUMO

OBJECTIVES: To evaluate the influence of multiplanar reconstruction thickness on the detection of peri-implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri-implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri-implant bone defects using a 5-point scale. Diagnostic parameters were calculated and compared using Two-way ANOVA (α = .05). RESULTS: The studied factors showed no significant influence on the diagnosis of peri-implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2-mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82). CONCLUSIONS: The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri-implant bone defects on CBCT images.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38801118

RESUMO

OBJECTIVE: This study was designed to compare discomfort/pain after periodontal and peri-implant probing in patients with titanium compared with zirconium implants. METHODS: One examiner recruited and examined 70 patients, each of whom had a dental implant with a contralateral tooth; 37 patients had titanium implants of various types and 33 patients had zirconium implants; one implant was analyzed for each patient. Periodontal and peri-implant probing pocket depth (PPD) and clinical attachment level (CAL) were assessed. Immediately after probing, patients rated their discomfort/pain with a visual analog scale (VAS). The emergence profiles of implant crowns were assessed on periapical radiographs of the implants. RESULTS: Seventy patients with a median age of 55 years (interquartile range [IQR]: 42-65 years), including 43 females and 16 current smokers, were examined. The mean PPD and bleeding on probing (BOP) were higher around implants than around teeth (p < .001). CAL and suppuration were well-balanced between implants and teeth. Peri-implant probing caused significantly more discomfort/pain than periodontal probing [median VAS score: 12.5 (IQR 4-22) vs. 9 (2-15); p < .001]. Logistic regression revealed that discomfort/pain after peri-implant probing was less intense in patients who had taken analgesic medication (p = .021) and around titanium implants (p = .037). CONCLUSIONS: Peri-implant probing caused significantly more discomfort/pain than periodontal probing. Patients who had taken analgesic medication experienced less discomfort and pain with peri-implant probing than those who had not; furthermore, titanium implants were associated with less pain than zirconium implants.

5.
Chem Pharm Bull (Tokyo) ; 72(3): 286-293, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38447973

RESUMO

To explore drug interactions involving sodium zirconium cyclosilicate hydrate (SZC) and concomitant drugs like calcium antagonists (amlodipine and nifedipine) and ß-blockers (carvedilol and bisoprolol), we investigate how these concomitant drugs influenced the administration of SZC in an artificial intestinal juice. Initially, we assessed the potassium ion adsorption capacity, ranking it as follows: calcium polystyrene sulfonate (CPS, 54.9 mg/g) < sodium polystyrene sulfonate (SPS, 62.1 mg/g) < SZC (90.8 mg/g). However, the adsorption equilibrium was achieved in the order of CPS ≒ SPS (within 1 min) < SZC (within 1 h). Subsequently, we determined the residual percentages of amlodipine, nifedipine, carvedilol, and bisoprolol, finding them to be 79.0-91.9% for SZC, 0.38-38.4% for SPS, and 0.57-29.0% for CPS. These results suggest the efficacy of SZC in managing hyperkalemia alongside concomitant drugs in an artificial intestinal juice, with particular emphasis on amlodipine (calcium antagonist) and carvedilol (ß-blocker). Additionally, we identified the presence of carbon, nitrogen, and oxygen components from both drugs on the SZC surface following interaction. We also evaluated how amlodipine, nifedipine, carvedilol, and bisoprolol affected the administration of SZC in the presence of potassium ions. Our results indicate that potassium ions and concomitant drugs did not interfere with each other in the artificial intestinal juice. These results offer valuable insights into the administration of SZC in conjunction with concomitant drugs. Lastly, the presented data shows qualitative results in this study.


Assuntos
Bisoprolol , Nifedipino , Poliestirenos , Silicatos , Preparações Farmacêuticas , Carvedilol , Cálcio , Anlodipino , Íons , Potássio
6.
Clin Oral Investig ; 28(1): 94, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38221600

RESUMO

OBJECTIVES: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. MATERIALS AND METHODS: Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. RESULTS: Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. CONCLUSIONS: Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. CLINICAL RELEVANCE: Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.


Assuntos
Cerâmica , Falha de Restauração Dentária , Zircônio , Prótese Parcial Fixa , Porcelana Dentária , Teste de Materiais , Análise do Estresse Dentário , Coroas
7.
J Arthroplasty ; 39(7): 1714-1718, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38244639

RESUMO

BACKGROUND: Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses. METHODS: A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians. RESULTS: The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 µg/L, range 0 to 1941 µg/L) and the "well-fixed" (mean 0.6 µg/L, range 0 to 6 µg/L) implants. The receiver operating characteristic analysis revealed 0.25 µg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66). CONCLUSIONS: Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.


Assuntos
Artroplastia do Joelho , Biomarcadores , Cimentos Ósseos , Prótese do Joelho , Falha de Prótese , Líquido Sinovial , Zircônio , Humanos , Zircônio/química , Idoso , Masculino , Feminino , Biomarcadores/análise , Líquido Sinovial/química , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Reoperação , Articulação do Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem
8.
J Esthet Restor Dent ; 36(9): 1326-1336, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38665052

RESUMO

OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.


Assuntos
Coroas , Análise do Estresse Dentário , Zircônio , Zircônio/química , Cerâmica/química , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Prótese Dentária Fixada por Implante , Teste de Materiais , Humanos
9.
Int J Mol Sci ; 25(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38928293

RESUMO

Zr-50Ti alloys are promising biomaterials due to their excellent mechanical properties and low magnetic susceptibility. However, Zr-50Ti alloys do not inherently bond well with bone. This study aims to enhance the bioactivity and bonding strength of Zr-50Ti alloys for orthopedic implant materials. Initially, the surface of Zr-50Ti alloys was treated with a sulfuric acid solution to create a microporous structure, increasing surface roughness and area. Subsequently, low crystalline calcium phosphate (L-CaP) precipitation was controlled by adding Mg2+ and/or CO32- ions in modified simulated body fluid (m-SBF). The treated Zr-50Ti alloys were then subjected to cold isostatic pressing to force m-SBF into the micropores, followed by incubation to allow L-CaP formation. The apatite-forming process was tested in simulated body fluid (SBF). The results demonstrated that the incorporation of Mg2+ and/or CO32- ions enabled the L-CaP to cover the entire surface of Zr-50Ti alloys within only one day. After short-term soaking in SBF, the L-CaP layer, modulated by Mg2+ and/or CO32- ions, formed a uniform hydroxyapatite (HA) coating on the surface of the Zr-50Ti alloys, showing potential for optimized bone integration. After soaking in SBF for 14 days, the bonding strength between the apatite layer and alloy has the potential to meet the orthopedic application requirement of 22 MPa. This study demonstrates an effective method to enhance the bioactivity and bonding strength of Zr-50Ti alloys for orthopedic applications.


Assuntos
Ligas , Líquidos Corporais , Fosfatos de Cálcio , Propriedades de Superfície , Zircônio , Ligas/química , Zircônio/química , Líquidos Corporais/química , Fosfatos de Cálcio/química , Titânio/química , Materiais Biocompatíveis/química , Teste de Materiais , Magnésio/química , Durapatita/química
10.
BMC Oral Health ; 24(1): 999, 2024 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-39183312

RESUMO

BACKGROUND: Marginal misfit and surface roughness of customized implant abutments is critical for restorative success. However, little is known about the comparison of misfit and surface roughness of CAD-CAM Zirconium oxide (ZrO), selective laser melting (SLM) Cobalt Chrome (CoCr) and preformed abutments. The aim of the study is to investigate the relation of misfit and micro-roughness of selective laser melting (SLM), preformed and CAD-CAM implant abutments. METHODS: Thirty internal connection, endosseous dental implants (Ø 4.0 mm x 10 mm, Dentium) were mounted in Polymethyl methacrylate vertically. Ten preformed Titanium alloy (Ti) abutments with 1 mm soft tissue height and Ø 4.5 mm were included as controls. Ten each of Y-TZP and SLM-CoCr, abutment/crowns were fabricated using CAD-CAM milling (CAD-CAM-ZrO) and SLM techniques. Surface micro-roughness (Ra) of the fabricated implant abutment/crown was evaluated with a 3D optical non-contact microscope. All implant restorations were torqued to implants (30 Ncm) using a Tohnichi BTGE digital torque gauge and were analyzed with Bruker micro-CT (Skyscan 1173) to detect micro-gaps at pre-selected points at implant abutment interface. The Ra and misfit data were compared using ANOVA, Tukey-Kramer, Kruskal-Wallis test and Pearson correlation (p < 0.05). RESULTS: Mean Ra among SLM CoCr abutments [0.88 (0.09) µm] were lower than CAD-CAM-ZrO and higher than preformed Ti abutments. Horizontal misfit among SLM-CoCr [45.43 (9.41) µm] and preformed Ti [36.87 (13.23) µm] abutments was not statistically different (p > 0.05). Misfit was significantly higher in Y-TZP samples compared to SLM-CoCr (p = 0.031) and preformed Ti abutments (p = 0.01). Preformed Ti abutments showed significantly lower misfit compared to SLM-CoCr abutments (p = 0.01). A positive linear correlation was observed between the surface roughness (Ra) and vertical misfit (r = 0.61, p < 0.05). CONCLUSION: SLM CoCr abutments showed rough surface compared to preformed Ti abutments, while horizontal misfit was comparable among SLM-CoCr and preformed abutments. Misfit was significantly greater in Y-TZP abutments, compared to SLM and preformed abutments. SLM abutment fabrication technique needs further improvement to provide better fit and surface topography.


Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Coroas , Dente Suporte , Projeto do Implante Dentário-Pivô , Lasers , Propriedades de Superfície , Titânio , Zircônio , Zircônio/química , Titânio/química , Ligas de Cromo/química , Humanos , Planejamento de Prótese Dentária , Adaptação Marginal Dentária
11.
BMC Oral Health ; 24(1): 760, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965507

RESUMO

BACKGROUND: Preservation of the remaining structures while maintaining an esthetic appearance is a major objective in removable partial prosthodontics. So, the aim of the current study was to compare the stresses induced on the supporting structures by two digitally produced esthetic core materials; Zirconia and Polyetheretherketone when used as an extracoronal attachment in distal extension removable partial dentures using strain gauge analysis. METHODS: A mandibular Kennedy class II stone cast with the necessary abutments' preparations was scanned. The mandibular left canine and first premolar teeth were virtually removed. An acrylic mandibular left canine and first premolar teeth were prepared with heavy chamfer finish line and scanned. Virtual superimposition of the acrylic teeth in their corresponding positions was done. Two strain gauge slots were designed: distal to the terminal abutment and in the residual ridge. Two models and two sets of scanned teeth were digitally printed. The printed teeth were then placed in their corresponding sockets in each model and scanned. The attachment design was selected from the software library and milled out of Zirconia in the model ZR and Polyetheretherketone in the model PE. Five removable partial dentures were constructed for each model. The strain gauges were installed in their grooves. A Universal testing machine was used for unilateral load application of 100 N (N). For each removable partial denture, five measurements were made. The data followed normal distribution and were statistically analyzed by using unpaired t test. P value < 0.05 was considered to be statistically significant. RESULTS: During unilateral loading unpaired t test showed statistically significant difference (p = 0.0001) in the microstrain values recorded distal to the abutment between the models ZR (-1001.6 µÎµ ± 24.56) and PE (-682.6 µÎµ ± 22.18). However, non statistically significant difference (p = 0.3122) was observed in the residual ridge between them; ZR (16.2 µÎµ ± 4.53) and PE (15 µÎµ ± 3.74). CONCLUSIONS: In removable partial dentures, Polyetheretherketone extracoronal attachment induces less stress on the supporting abutments compared to the zirconia one with no difference in the stresses induced by them on the residual ridge.


Assuntos
Benzofenonas , Planejamento de Dentadura , Prótese Parcial Removível , Cetonas , Polímeros , Zircônio , Cetonas/química , Humanos , Zircônio/química , Polietilenoglicóis , Análise do Estresse Dentário , Materiais Dentários/química , Desenho Assistido por Computador , Dente Suporte , Estresse Mecânico , Estética Dentária , Teste de Materiais
12.
J Prosthodont ; 33(4): 382-388, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37155925

RESUMO

PURPOSE: The purpose of this in vitro study was to assess the color match of ultra-translucency multilayer zirconia restorations with different designs and backgrounds. MATERIALS AND METHODS: Thirty ultra-translucency multilayer zirconia crown specimens were made in VITA classical shade B2 for a prepared maxillary central incisor. The specimens were divided into three groups based on the restoration design: veneered zirconia with a trestle design (VZT), veneered zirconia with a dentin core design (VZD), and full-contour zirconia (FCZ). In the groups VZT and VZD, the zirconia specimens were layered with a feldspathic veneering ceramic. The specimens were seated on five different backgrounds: shade B2 composite resin, shade B2 zirconia, copper-colored metal alloy, silver-colored metal alloy, and the prepared central incisor. CIELab values of the labial middle sections of the crown specimens were measured with a spectrophotometer. Color differences between the specimens and a shade B2 VITA classical tab (as a control) were calculated from the ΔE* ab formula and compared with an acceptability threshold (ΔE* ab = 3.7) to be clinically explicated. RESULTS: Mean ΔE* ab values ranged between 1.17 and 8.48. The restoration design, the background type, and their interaction affected the ΔE* ab (p < 0.001). The mean ΔE* ab values for VZT with all backgrounds and for VZD with the silver-colored metal background were greater than the threshold (p < 0.001), whereas the mean ΔE* ab values for VZD with the other backgrounds and FCZ with all backgrounds were less than the threshold (p = 1). CONCLUSIONS: Restoration design and background type affected the color match of ultra-translucency multilayer zirconia restorations. VZT restorations on all backgrounds and VZD restorations on a silver-colored metal background showed color mismatches. However, VZD restorations on the other backgrounds and FCZ restorations on all backgrounds demonstrated color matches.


Assuntos
Porcelana Dentária , Prata , Cor , Teste de Materiais , Propriedades de Superfície , Cerâmica , Materiais Dentários , Zircônio , Ligas
13.
J Prosthodont ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38734932

RESUMO

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

14.
J Evid Based Dent Pract ; 24(2): 101970, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38821661

RESUMO

OBJECTIVES: The primary aim was to investigate survival rate of zirconia versus metal abutments, and the secondary aim was clinical outcomes of all-ceramic versus metal-ceramic crowns on single-tooth implants. METHODS: Patients with tooth-agenesis participated to previously published prospective clinical study with 3-year follow-up were recalled after 5 years. Biological variables included survival and success rate of implants, marginal bone level, modified Plaque and Sulcus Bleeding Index and biological complications. Technical variables included restoration survival rate, marginal adaptation and technical complications. The aesthetic outcome of crowns and peri-implant mucosa in addition to patient-reported outcome were recorded. Descriptive analysis, linear mixed model for quantitative data, or generalized linear mixed model for ordinal categorical data were applied; significance was set to 0.05. RESULTS: Fifty-three patients (mean age: 32.4 years), with 89 implants participated to the 5-years examination. The implants supported 50 zirconia abutments with 50 all-ceramic (AC) crown and 39 metal abutments with 29 metal-ceramic (MC) and 10 AC crowns. The Implant and restoration survival rate was 100% and 96%, respectively. No clinically relevant biological difference between implants supporting metal or zirconia abutments was registered. The technical complications were veneering fracture of AC-crowns (n = 3), crown loosening of MC-crowns (n = 4) and one abutment screw loosening (MC-crown on metal abutment). MC-crowns had significantly better marginal adaptation than AC-crowns (p = .01). AC-crowns had significantly better color and morphology than MC-crowns (p = .01). CONCLUSIONS: Zirconia-based single-tooth restorations are reliable alternative materials to metal-based restorations with favorable biological and aesthetic outcome, and few technical complications.


Assuntos
Coroas , Dente Suporte , Implantes Dentários para Um Único Dente , Prótese Dentária Fixada por Implante , Zircônio , Humanos , Estudos Prospectivos , Feminino , Masculino , Adulto , Falha de Restauração Dentária , Pessoa de Meia-Idade , Anodontia , Adulto Jovem , Ligas Metalo-Cerâmicas , Estética Dentária
15.
Stomatologiia (Mosk) ; 103(3): 39-41, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38904558

RESUMO

Ceramic based on zirconium dioxide (ZD) is a modern, durable material for the manufacture of dentures. It is known that ZD is not etched as glass-ceramic, making it difficult to prepare this material before fixing. OBJECTIVE: To study the impact of various methods of surface treatment of ZD-based ceramic on adhesive strength. MATERIALS AND METHODS: Sandblasting with Al2O3 particles sized 50 µm and application of primers with 10-MDP phosphate monomer were used. Adhesive strength values for following 4 groups of samples were obtained: 1st group - RelyX U200 + sandblasting + Compofix new primer (n=9); 2nd group - Compofix + sandblasting + Compofix new primer (n=9); 3rd group - Panavia F 2.0 + sandblasting (n=9); 4th group (control) - Variolink Esthetic DC + sandblasting + Monobond Plus primer (n=9). RESULTS: The highest strength of adhesion was in the 4th group - 48.71±5.71MPa, the smallest in the 3rd group - 9.49±35.24 MPa. Fully domestic components used in the 2nd group allowed to obtain values of 42.50±9.79 MPa. Adhesive strength in the 1st group was 34.11±4.78 MPa. CONCLUSION: The absence of the 10-MDP-based primers application in the preparation of ZD ceramic reduces the adhesive strength between resin cement and its surface. The domestic set for fixation of dentures can be effectively used for ZD on the same basis as European analogue.


Assuntos
Propriedades de Superfície , Zircônio , Zircônio/química , Teste de Materiais , Cerâmica/química , Colagem Dentária/métodos , Cimentos de Resina/química , Humanos , Cimentos Dentários/química , Corrosão Dentária/métodos
16.
Clin Oral Implants Res ; 34(1): 20-32, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36259118

RESUMO

OBJECTIVES: The purpose of this study was to investigate the efficiency of different implant-decontamination methods regarding biofilm modification and potential cytotoxic effects. Therefore, the amount of biofilm reduction, cytocompatibility, and elementary surface alterations were evaluated after decontamination of titanium and zirconium surfaces. MATERIAL AND METHODS: Titanium and zirconium disks were contaminated with a newly developed high-adherence biofilm consisting of six microbial species. Decontaminations were performed using titanium curette, stainless steel ultrasonic scaler (US), glycine (GPAP) and erythritol (EPAP) powder air-polishing, Er:YAG laser, 1% chlorhexidine (CHX), 10% povidone-iodine (PVI), 14% doxycycline (doxy), and 0.95% NaOCl solution. Microbiologic analysis was done using real-time qPCR. For assessment of cytocompatibility, a multiplex assay for the detection of cytotoxicity, viability, and apoptosis on human gingival fibroblasts was performed. X-ray photoelectron spectroscopy (XPS) was used to evaluate chemical alterations on implant surfaces. RESULTS: Compared with untreated control disks, only GPAP, EPAP, US, and Er:YAG laser significantly reduced rRNA counts (activity) on titanium and zirconium (p < .01), whereas NaOCl decreased rRNA count on titanium (p < .01). Genome count (bacterial presence) was significantly reduced by GPAP, EPAP, and US on zirconium only (p < .05). X-ray photoelectron spectroscopy analyses revealed relevant re-exposure of implant surface elements after GPAP, EPAP, and US treatment on both materials, however, not after Er:YAG laser application. Cytocompatibility was impaired by CHX, PVI, doxy, and NaOCl. CHX and PVI resulted in the lowest viability and doxy in the highest apoptosis. CONCLUSIONS: Within the limits of this in vitro study, air-polishing methods and ultrasonic device resulted in effective biofilm inactivation with surface re-exposure and favorable cytocompatibility on titanium and zirconium. Chemical agents, when applied on implant surfaces, may cause potential cytotoxic effects.


Assuntos
Anti-Infecciosos , Implantes Dentários , Humanos , Titânio/química , Zircônio/farmacologia , Descontaminação/métodos , Clorexidina/farmacologia , Biofilmes , Propriedades de Superfície , Implantes Dentários/microbiologia
17.
Clin Oral Implants Res ; 34 Suppl 26: 125-142, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750527

RESUMO

OBJECTIVES: In patients with dental implants, what is the effect of transmucosal components made of materials other than titanium (alloys) compared to titanium (alloys) on the surrounding peri-implant tissues after at least 1 year? MATERIALS AND METHODS: This systematic review included eligible randomized controlled trials identified through an electronic search (Medline, Embase and Web of Science) comparing alternative abutment materials versus titanium (alloy) abutments with a minimum follow-up of 1 year and including at least 10 patients/group. Primary outcomes were peri-implant marginal bone level (MBL) and probing depth (PD), these were evaluated based on meta-analyses. Abutment survival, biological and technical complications and aesthetic outcomes were the secondary outcomes. The risk of bias was assessed with the RoB2-tool. This review is registered in PROSPERO with the number (CRD42022376487). RESULTS: From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 12 articles could be included. Concerning the primary outcomes (MBL and PD), no differences could be seen between titanium abutment and zirconia or alumina abutments, not after 1 year (MBL: zirconia: MD = -0.24, 95% CI: -0.65 to 0.16, alumina: MD = -0.06, 95% CI: -0.29 to 0.17) (PD: zirconia: MD = -0.06, 95% CI: -0.41 to 0.30, alumina: MD = -0.29, 95% CI: -0.96 to 0.38), nor after 5 years. Additionally, no differences were found concerning the biological complications and aesthetic outcomes. The most important technical finding was abutment fracture in the ceramic group and chipping of the veneering material. CONCLUSIONS: Biologically, titanium and zirconia abutments seem to function equally up to 5 years after placement.


Assuntos
Implantes Dentários , Titânio , Humanos , Ligas , Óxido de Alumínio
18.
Clin Oral Implants Res ; 34 Suppl 26: 112-124, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37750521

RESUMO

OBJECTIVES: For the present review, the following focused question was addressed: In patients with root-analog dental implants, what is the effect of implants made of other materials than titanium (alloy) on implant survival, marginal bone loss (MBL), and technical and biological complications after at least 5 years. MATERIALS AND METHODS: An electronic (Medline, Embase, Web of Science) search was performed to identify observational clinical studies published from January 2000 investigating a minimum of 20 commercially available zirconia implants with a mean follow-up of at least 60 months. Primary outcome was implant survival, secondary outcomes included peri-implant MBL, probing depths (PDs), and technical and biological complications. Meta-analyses were performed to evaluate implant survival, MBL, and PD. RESULTS: From 5129 titles, 580 abstracts were selected, and 111 full-text articles were screened. Finally, 4 prospective and 2 retrospective observational clinical cohort studies were included for data extraction. Meta-analyses estimated after 5 years of loading mean values of 97.2% (95% CI 94.7-99.1) for survival (277 implants, 221 patients), 1.1 mm (95% CI: 0.9-1.3) for MBL (229 implants, 173 patients), and 3.0 mm (95% CI 2.5-3.4) for PDs (231 implants, 175 patients). CONCLUSIONS: After 5 years, commercially available zirconia implants showed reliable clinical performance based on survival rates, MBL, and PD values. However, more well-designed prospective clinical studies and randomized clinical trials investigating titanium and zirconia implants are needed to confirm the presently evaluated promising outcomes.


Assuntos
Doenças Ósseas Metabólicas , Implantes Dentários , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Titânio
19.
Clin Oral Implants Res ; 34(7): 751-767, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37232220

RESUMO

BACKGROUND: Narrow diameter implants (NDIs) are used in cases of limited mesio-distal space, or if the alveolar ridge does not allow placement of a standard diameter implant. PURPOSE: The aim of this prospective case series study is to present the 5-year clinical-, radiological-, and patient-reported outcome measures (PROMs) of patients with partial edentulism in the anterior area of the jaws requiring the placement of two narrow diameter implants to support a 3- or 4-unit fixed partial denture (FPD). MATERIALS AND METHODS: Thirty partially edentulous patients missing 3 or 4 adjacent teeth in the anterior area of the jaws were included in the study. Two titanium-zirconium tissue-level NDIs were placed in each patient in healed anterior sites (60 implants). A conventional loading protocol was performed to provide a FPD. Implant survival, success, marginal bone-level changes (MBL), clinical parameters, buccal bone stability with CBCT, adverse events and PROMs were recorded. RESULTS: The survival and success rates for the implants were 100%. The mean MBL (±SD) after prosthesis delivery, and 5-year follow-up (mean 58.8 months; range: 36-60) was 0.12 ± 0.22 and 0.52 ± 0.46 mm, respectively. Decementation and screw loosening were the most frequent prosthetic complications, yielding a prosthetic survival and success rates of 100% and 80%, respectively. Patient satisfaction was high with a mean (±SD) score of 89.6 ± 15.1. CONCLUSIONS: The use of tissue-level titanium-zirconium NDIs supporting splinted multi-unit FPDs in the anterior area seems to be a safe and predictable treatment option after a 5-year follow-up period.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Humanos , Estudos Prospectivos , Zircônio , Titânio , Planejamento de Prótese Dentária , Seguimentos , Prótese Dentária Fixada por Implante , Resultado do Tratamento
20.
Clin Oral Investig ; 27(11): 6279-6290, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37740825

RESUMO

OBJECTIVE: This systematic review assessed the available evidence on the survival and success rate of zirconia and titanium implants. As secondary outcomes, aesthetic, radiographic and clinical parameters, as well as biological and mechanical complications, were considered. MATERIALS AND METHODS: A systematic search was performed up to March 2022 to identify CCTs/RCTs comparing zirconia and titanium implants with a minimum of 12 months of follow-up. Meta-analysis was performed when ≥ 2 articles with similar characteristics were retrieved. RESULTS: Four published articles with two RCTs (2 different patient populations) with 100 zirconia and 99 titanium implants that were followed up over 12-80 months were selected out of the 6040 articles. A non-statistically significant difference between zirconia and titanium implant survival at 12 months was suggested (P = 0.0938). The success rates were 57.5-93.3% and 57.1-100% for zirconia and titanium implants, respectively. The pink aesthetic score (PES) was higher for zirconia (10.33 ± 2.06 to 11.38 ± 0.92) compared to titanium implants (8.14 ± 3.58 to 11.56 ± 1.0). CONCLUSION: Based on the 2 RCTs retrieved in the literature, similar survival rates were reported for zirconia and titanium implants in the short term (12 months of follow-up). Future RCTs are warranted to evaluate the long-term outcomes of zirconia implants. CLINICAL RELEVANCE: Zirconia implants may be the procedure of choice, particularly in the aesthetic zone, since they show a similar survival and success rate as titanium implants on a short-term follow-up. TRIAL REGISTRATION: Systematic review registration number-CRD42021288704 (PROSPERO).


Assuntos
Implantes Dentários , Humanos , Titânio , Falha de Restauração Dentária , Estética Dentária , Zircônio , Planejamento de Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA