Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 281
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Int Endod J ; 57(8): 1021-1042, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38606520

RESUMO

BACKGROUND: Limited evidence is available regarding the superior clinical properties of bioceramic sealers comparted with traditional standard sealers. OBJECTIVES: This review aimed to answer the following research questions: 'In healthy patients requiring a root canal treatment (P), what is the efficacy of premixed bioceramic sealers (I) compared with traditional root canal epoxy resin-based sealers (C) in terms of survival, success rates (PICO1) sealer extrusion and resorption (PICO2) post-obturation pain (PICO3) (O)?' METHODS: Authors independently searched three electronic databases: PubMed (including MEDLINE), Web of Science, Embase and Scopus up to 31 October 2023. This was accompanied by both grey literature and manual search. Detailed selection criteria were applied, namely mature permanent teeth requiring root canal treatment, premixed bioceramic sealer with gutta-percha as an intervention group, a standard filling technique as control group and full-text available in English. A random-effect meta-analysis was used to synthesize the body of evidence regarding the use of bioceramic sealers in root canal treatment and their impact on post-obturation pain. Effect sizes were represented as relative risks on a logarithmic scale for binary outcomes and as mean differences for continuous outcomes. RESULTS: A total of 941 articles were identified. Fifteen Comparative clinical studies were finally included. Eleven were randomized clinical trials, and four were prospective clinical trials with control group. The follow-up of these studies was not greater than 2 years. No publication bias was observed in any study. No significant differences were observed between the two groups in terms of survival and success rates. A small non-significant lower risk of extrusion was observed for bioceramics. A small, non-significantly lower post-operative-pain within 24-h was observed when bioceramics were used. DISCUSSION: The majority of current evidence shows inconsistencies in reporting and is of short-term duration. Robust prospective long-term trials are needed in this area to better support future recommendations. CONCLUSION: This systematic review is the first to analyse several clinical outcomes using premixed sealers. Included studies differed in terms of clinical protocol and operator expertise, but reported a similar outcome when comparing bioceramic versus standard sealers. Tooth survival, treatment outcome, post-operative pain and periapical extrusion were similar and presented no significant differences between the two sealer types. REGISTRATION: PROSPERO database (CRD42023449151).


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/uso terapêutico , Resultado do Tratamento , Obturação do Canal Radicular/métodos , Cerâmica , Tratamento do Canal Radicular/métodos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Resinas Epóxi/uso terapêutico , Guta-Percha/uso terapêutico
2.
Odontology ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39060895

RESUMO

OBJECTIVE: This study evaluated the influence of melatonin supplementation on tissue's response of endodontic sealers in Wistar rats. METHODOLOGY: Forty-eight rats received subcutaneous implants of four polyethylene tubes: one empty (control) and three filled with endodontic sealers (AH Plus, Endofill and Sealapex). Half of the animals were supplemented with melatonin (ME) and the remaining treated with water (WA) for 15 days before the implantation until euthanasia, forming the groups: control-WA, AH Plus-WA, Endofill-WA, Sealapex-WA, Control-ME, AH Plus-ME, Endofill-ME and Sealapex-ME. After 5, 15 and 30 days, (n = 8) tubes were removed and evaluated in H&E., immunohistochemistry, PSR, VK and POL. The results were statistically analyzed (p < 0.05). RESULTS: In animals treated with water, Endofill-WA evoked more intense inflammatory infiltrate compared to AH Plus-WA and Control-WA in a 30-day period (p < 0.05). In animals supplemented with melatonin, there was any difference among endodontic sealers' response in any period of analysis (p > 0.05). Comparing the individual response of each sealer, over a 30-day period, Endofill-ME and Sealapex-ME showed less inflammatory infiltrate compared to Endofill-WA and Sealapex-WA, respectively (p < 0.05). Immunostaining for IL-6 and TNF-α was less intense for all groups in animals supplemented with melatonin, in most periods, except for the Endofill sealer (p < 0.05). Furthermore, Endofill-ME at 5 days and AH-Plus-ME at 30 days showed a higher percentage of mature collagen fibers compared to the Endofill-WA and AH Plus-WA, respectively (p < 0.05). Positive structures for von Kossa staining and birefringent to polarized light were observed only for Sealapex-WA and Sealapex-ME in all periods. CONCLUSIONS: It can be concluded that melatonin influences the tissue response to endodontic sealers, modulating the inflammatory and reparative process.

3.
Odontology ; 112(3): 657-671, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38381264

RESUMO

This scoping review aimed to map whether the use of sonic and ultrasonic methods to activate the endodontic sealer improves the sealer filling quality in the root canal, considering the bond strength and intratubular penetration to the root dentin as evaluation criteria. The study protocol was prospectively registered and is available online ( https://osf.io/x5fma/ ). Reporting was based on PRISMA Extension for Scoping Reviews. The search was performed in Embase, PubMed, Scopus, and Web of Science. We selected studies without time and language restrictions that used sonic or ultrasonic methods to activate endodontic sealer, whose outcomes were bond strength and intratubular penetration. Three researchers independently selected the articles and collected data. Of 1422 articles, 19 were read in full and 13 studies were included. The vast majority of studies opted for direct activation of the endodontic sealer. The most investigated sealers were the epoxy resin-based sealers, and the ultrasonic activation method was the most explored. For the bond strength outcome, there was a trend toward higher values when the sealer was activated ultrasonically, but the findings seem to be divergent. The sonic activation was not effective for its intended purpose. For the outcome of intratubular penetration, the vast majority of studies indicate that the use of sonic and ultrasonic methods to activate the endodontic sealer is capable of increasing intratubular penetration. The use of sonic and ultrasonic methods to directly activate the endodontic sealer can increase the intratubular penetration of the sealer, but their benefits on the bond strength are uncertain.


Assuntos
Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/química , Humanos , Ultrassom , Obturação do Canal Radicular/métodos , Colagem Dentária/métodos , Sonicação
4.
Molecules ; 29(18)2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39339417

RESUMO

This study evaluated push-out bond test (POBT), surface roughness, and antimicrobial properties against Enterococcus faecalis of bioceramic sealers supplemented with silver nanoparticles (AgNPs). The sealers tested were CeraSeal®, EndoSequence® BC SealerTM, and Bio-C® Sealer. The POBT was measured with a Universal Testing Machine, and the type of failure was evaluated with a stereomicroscope. The roughness average (Sa) and peak-valley height (Sy) values were evaluated by atomic force microscopy. The bacterial growth inhibition was evaluated using a disk diffusion test, and antimicrobial activity was determined with the plate microdilution method. The POBT showed no significant difference between sealers with and those without NPs in cervical and apical thirds (p > 0.05). In the middle third, the adhesion force was significant for Endosequence BC Sealer® (p < 0.05). The results showed that the Sa and Sy parameters, when AgNPs were added, did not show a statistically significant difference compared to the groups without nanoparticles (p > 0.05). All tested sealers showed bacterial growth inhibition, but no significant difference was found. Their efficacy, in descending order of antibacterial activity when AgNPs were added, is as follows: EndoSequence® BC SealerTM > Bio-C® Sealer > CeraSeal®. The incorporation of AgNPs into bioceramics improves antimicrobial activity without affecting mechanical properties.


Assuntos
Enterococcus faecalis , Nanopartículas Metálicas , Materiais Restauradores do Canal Radicular , Prata , Propriedades de Superfície , Prata/química , Prata/farmacologia , Nanopartículas Metálicas/química , Materiais Restauradores do Canal Radicular/química , Materiais Restauradores do Canal Radicular/farmacologia , Enterococcus faecalis/efeitos dos fármacos , Enterococcus faecalis/crescimento & desenvolvimento , Anti-Infecciosos/farmacologia , Anti-Infecciosos/química , Antibacterianos/farmacologia , Antibacterianos/química , Teste de Materiais , Humanos , Testes de Sensibilidade Microbiana , Cerâmica/química , Cerâmica/farmacologia , Microscopia de Força Atômica , Fosfatos de Cálcio , Combinação de Medicamentos , Óxidos , Silicatos
5.
BMC Oral Health ; 24(1): 258, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378554

RESUMO

AIM: To compare and evaluate the sealing ability of four different commercially available sealers to provide seal against the dye penetration test using a stereomicroscope-an in-vitro study. MATERIAL/METHOD: 80 extracted single rooted mandibular premolar with single canal were used in this study. The samples were divided in 4 groups (20 in each) based on sealer. Group I (Diaproseal), Group II (apexit Plus), Group III (MTA Fillapex) and Group IV (Bio-C). The samples were analyzed using a stereomicroscope and data analysis was done with one-way Anova And post hoc Tukey's test. RESULT: The mean dye penetration score was 1.2400 ± 0.778 mm for Group I. 2.6000 ± 0.897 mm for Group II, 4.2000 ± 0.923 mm for Group III and 4.225 ± 2.055 mm for Group IV. One-way Anova analysis shows that intergroup comparison was statistically significant between the four groups. The post hoc Tukey's test reveals that the difference was statistically non-significant between group III and group IV. CONCLUSION: It was concluded that between the four groups the Group I (Diaproseal) showed the least dye penetration followed by Group II (Apexit Pus), Group III (MTA Fillapex) and then Group IV (Bio-C), where there was no significant difference between the Group III (MTA Fillapex) and Group IV (Bio-C).


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Cavidade Pulpar , Hidróxido de Cálcio , Microscopia
6.
BMC Oral Health ; 24(1): 352, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504287

RESUMO

BACKGROUND: AH Plus, an epoxy resin-based sealer, is widely used in endodontic practice, owing to its good physical properties that confers longstanding dimensional stability and good adhesion to dentin. Nevertheless, its propensity to trigger inflammation, especially in its freshly mixed state, has been extensively documented. Phytochemicals such as Petasin, Pachymic acid, Curcumin, and Shilajit are known for their anti-inflammatory and analgesic effects. This study aimed to analyze and determine the effect of these natural products on the physical properties of AH Plus sealer when incorporated with the sealer. METHODS: AH Plus (AHR) sealer was mixed with 10% petasin, 0.75% pachymic, 0.5% and 6%shilajit to obtain AHP, AHA, AHC and AHS in the ratio of 10:1 and 5:1 respectively. Five samples of each material were assessed for setting time, solubility, flow, and dimensional stability in accordance with the ISO 6876:2012 standardization. Sealers were characterized through scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy, X-ray diffraction (XRD), and Fourier transform infrared (FTIR) spectroscopy. Statistical evaluation involved the Kolmogorov-Smirnov and Shapiro-Wilks tests for normality and the one-way ANOVA test for analysis. RESULTS: In this investigation, the characterisation analysis revealed a relatively similar microstructure in all the experimental root canal sealers. All experimental groups, excluding the control group, exhibited an increase in flow ranging from 11.9 to 31.4% at a 10:1 ratio. Similarly, for the 5:1 ratio, the increase ranged from 12.02 to 31.83%. In terms of dimensional stability, all groups at the 10:1 ratio showed a decrease compared to the control group. The addition of natural agents to AHR in 10:1 ratio led to a reduction in setting time by 8.9-31.6%, and at a 5:1 ratio, the reduction ranged from 8.1 to 31.5%. However, regarding solubility, the addition of natural agents did not induce any significant alterations. CONCLUSION: Based on the results of this study, it can be concluded that all tested root canal sealers exhibited properties that met the acceptable criteria outlined in the ISO 6876:2012 standardization.


Assuntos
Curcumina , Minerais , Resinas Vegetais , Materiais Restauradores do Canal Radicular , Sesquiterpenos , Triterpenos , Humanos , Materiais Restauradores do Canal Radicular/química , Curcumina/farmacologia , Resinas Epóxi , Teste de Materiais , Silicatos/química , Compostos de Cálcio/química
7.
J Contemp Dent Pract ; 25(4): 335-341, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38956848

RESUMO

AIM OF THE STUDY: The study aimed to assess the microleakage of nanoparticle-based (NPB) cyanoacrylate sealer and epoxy resin-based (ERB) sealer using radioisotope method and confocal laser scanning microscopy (CLSM). MATERIALS AND METHODS: A total of 100 single-rooted teeth were collected; specimens were accessed, instrumented, and irrigated, and randomly distributed into 4 groups of 25 samples each: Group I: Positive control, group II: Negative control, group III: Obturated with NPB sealer, and group IV: Obturated with ERB sealer. All samples were immersed in 99mTc pertechnetate solution, for 3 hours after which radioactivity was estimated under a Gamma camera. The radioactivity released by specimens before and after nail varnish removal was statistically analyzed. After 2 weeks, the same samples were used for CLSM analysis. The sealer tubular penetration depth was measured at the deepest level for each group using ZEN lite 2012. Data collected was statistically evaluated. RESULTS: The amount of radioactivity observed at first in group III and group IV was 194.76 and 599.12 units, respectively, with p-value < 0.001, indicating significant interaction, and after nail varnish removal, it was 89.68 and 468.44 units, respectively, with a p-value < 0.001; again, indicating statistical significance. Hence, the radioactivity of NPB sealer was found to be lower than ERB sealer in both cases, indicating better sealing of the former. The photomicrographs show that mean value of dye penetration in NPB sealer in first, second, and third segment from apex was 85.06, 75.73, and 66.09, respectively; while in the case of ERB sealer, those were 597.28, 461.17, and 195.68, respectively; with p-value < 0.001; signifying that NPB sealer exhibited higher resistance to microleakage than ERB sealer. CONCLUSION: The NPB sealer can become a potential root canal sealer in future endodontics due to superior physiochemical properties attributed to the cyanoacrylate and incorporated nanoparticles. CLINICAL SIGNIFICANCE: The study clinically signifies that we can equally use the radioisotopic method along with confocal method while conducting the microleakage studies. In addition, NPB sealer can be an emerging replacement with better properties than gold standard root canal sealers for clinical use. How to cite this article: Shetty C, Qaiser S, Shetty A, et al. Evaluation of Microleakage of Nanoparticle-incorporated Cyanoacrylate Root Canal Sealer Using the Radioisotopic Method: An In Vitro Study. J Contemp Dent Pract 2024;25(4):335-341.


Assuntos
Infiltração Dentária , Resinas Epóxi , Microscopia Confocal , Nanopartículas , Materiais Restauradores do Canal Radicular , Infiltração Dentária/prevenção & controle , Materiais Restauradores do Canal Radicular/química , Humanos , Técnicas In Vitro , Cianoacrilatos , Obturação do Canal Radicular/métodos , Pertecnetato Tc 99m de Sódio , Teste de Materiais
8.
Int Endod J ; 56 Suppl 3: 436-454, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35735776

RESUMO

BACKGROUND: Apical periodontitis (AP) is an inflammatory disease of the apical periodontium as sequelae of pulp death. It is managed by disinfection and filling of the root canal space. OBJECTIVES: The aim of this systematic review was to investigate whether obturation techniques and materials used for root canal filling led to the management of AP. METHODS: A systematic review protocol was written following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) checklist and registered on the international prospective register of systematic reviews (PROSPERO; CRD42021260275) including two populations, interventions, comparisons, outcomes and time (PICOT) for the research questions querying the effectiveness of obturation techniques (PICOT 1) and materials (PICOT 2) for the management of AP. Electronic searches were conducted on PubMed, ScienceDirect, Scopus and Embase search engines. Searches on International Endodontic Journal, Journal of Endodontics, Clinical Oral Investigations, Journal of Dental Research and Journal of Dentistry websites were also conducted, until May 2021. Both primary (tooth survival) and secondary outcomes were evaluated. The risk of bias was assessed by Cochrane RoB2 for the randomized and ROBINS-I for the nonrandomized trials. RESULTS: The search strategy identified 1652 studies, with 1600 excluded on the title and abstract screening, leaving 52 studies for full-text screening. In total, 10 studies met the inclusion criteria. The obturation technique and materials used did not affect the outcome of AP. Vertical compaction resulted in faster resolution of periapical lesions. The oral health-related quality of life of patients treated with lateral condensation exhibited poorer outcomes compared with single matched cone after 6 months of recall. DISCUSSION: The inclusion and exclusion criteria used for this systematic review enabled the capture of all the literature available on the effect of obturation techniques and materials on the outcome of AP. The data were heterogenous, and a number of articles investigating obturation techniques had no information on the materials and techniques used as they looked at the quality of fill. CONCLUSIONS: Included studies did not find any difference between different procedures (PICOT 1) and materials (PICOT 2). The risk of bias was high, thus the findings should be interpreted with caution. REGISTRATION: PROSPERO registration number: CRD42021260275.


Assuntos
Periodontite Periapical , Materiais Restauradores do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/uso terapêutico , Guta-Percha/uso terapêutico , Qualidade de Vida , Revisões Sistemáticas como Assunto , Obturação do Canal Radicular/métodos , Periodontite Periapical/tratamento farmacológico , Preparo de Canal Radicular/métodos , Cavidade Pulpar
9.
Int Endod J ; 56(3): 318-330, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36385378

RESUMO

AIM: This randomized clinical trial aimed to evaluate and compare the effect of mineral trioxide aggregate (MTA)-based bioceramic- and resin-based sealers on the incidence and intensity of post-obturation pain and treatment outcome in asymptomatic vital molar teeth in single-visit root canal treatment. METHODOLOGY: One hundred asymptomatic mandibular molar teeth with vital pulp were randomly assigned into two groups according to the sealer used: MTA Fillapex or AH Plus sealer. WaveOne Gold instruments were used for root canal preparations. Root canals were obturated with WaveOne Gold gutta-percha cones corresponding in size and taper to the last instrument used. MTA Fillapex was used in the first group and AH Plus was used in the second group as the root canal sealer. The effects of age, gender, tooth types and the level of root canal filling on the treatment outcome were evaluated after 1 and 2 years. Postoperative pain at 6, 12, 24, 48, 72 h, 4, 5, 6, 7 and 30 days after root canal treatment was measured with the Numerical Rating Scale. Chi-square test was used for the treatment outcome and Mann-Whitney U, chi-Square and Spearman correlation analyses were used for postoperative pain. α = .05 was the level of significance. RESULTS: Twelve patients did not complete the 2-year follow-up and the study finished with 88 patients. In the MTA Fillapex group 41 correct, one short, two extruded, and in the AH Plus group 40 correct, one short and three extruded root canal fillings were detected. No significant differences were observed between the first- and second-year treatment outcomes between the groups (p > .05).There was no association between age, gender, tooth number, root canal filling length and the treatment success in all evaluated teeth (p > .05). The differences between the groups in terms of postoperative pain incidence and intensity at all time-points were not significant (p > .05). There was no correlation between the age and postoperative pain (p > .05), but pain was statistically higher in women (p < .05). CONCLUSIONS: Mineral trioxide aggregate Fillapex showed similar success rate and post-obturation pain incidence and intensity as AH Plus sealer and can be used as a root canal sealer in asymptomatic mandibular molars with irreversible pulpitis.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Feminino , Lactente , Pré-Escolar , Materiais Restauradores do Canal Radicular/uso terapêutico , Cavidade Pulpar , Estudos Prospectivos , Guta-Percha , Obturação do Canal Radicular , Preparo de Canal Radicular , Dor Pós-Operatória/tratamento farmacológico , Resultado do Tratamento , Resinas Epóxi
10.
Clin Oral Investig ; 27(12): 7919-7933, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38032392

RESUMO

AIM: To evaluate the bond strength (BS) and analysis of the adhesive interface in root canals filled with bioceramic gutta percha sealers and cones. MATERIAL AND METHODS: Ninety-six maxillary canines were divided into eight groups according to the endodontic sealer (AH Plus, AH Plus Bioceramic, Bio-C Sealer or Bio-C Sealer Ion+ and gutta percha cones (conventional or bioceramic) tested. They were analyzed using the BS test, failure pattern, analysis of the adhesive interface by scanning electron microscopy and confocal laser scanning microscopy. The BS data were compared between groups using the analysis of variance test with the Turkey post-test. The chi-square test was used to assess the type of failure and the non-parametric Mann-Whitney and Kruse-Wallis tests (P < 0.05). RESULTS: Analysis of variance showed higher BS values for the groups of bioceramic gutta percha cones in Bio-C Sealer Ion+ (8.38 ± 4.27), AH Plus Bioceramic (6.19 ± 3.28), Bio-C Sealer (5.70 ± 3.18), AH Plus (4.61 ± 2.11) and for conventional gutta percha cones in AH Plus sealers (4.26 ± 2.35), Bio-C Sealer Ion + (3.63 ± 2.29), Bio-C Sealer (2.94 ± 2.32) and AH Plus Bioceramic (1.19 ± 0.89) (P < 0.05). Relative to the type of failure and adaptation of the types of filling material, a higher percentage of mixed failures was observed (gaps between 1 µm-10 µm) for the group with bioceramic gutta percha cones (P < 0.001). CONCLUSION: The bond between sealers and bioceramic gutta percha cones showed higher bond strength values and greater penetration into the dentin tubules. CLINICAL RELEVANCE: The filling the root canal system with bioceramic sealers should be associated with bioceramic gutta percha cones.


Assuntos
Guta-Percha , Materiais Restauradores do Canal Radicular , Guta-Percha/química , Materiais Restauradores do Canal Radicular/química , Resinas Epóxi/química , Cavidade Pulpar , Cimentos Dentários , Obturação do Canal Radicular , Teste de Materiais
11.
Clin Oral Investig ; 27(8): 4147-4155, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37460901

RESUMO

OBJECTIVES: The introduction of hydraulic cement sealers has increased the popularity of single cone obturation where the chemistry and properties of hydraulic cement sealers are crucial. This article has investigated the materials present on the market by reviewing the chemistry aiming at understanding whether these materials are optimized or have been tested appropriately. METHODOLOGY: A market search on materials called bioceramic and hydraulic sealers was undertaken. The safety data sheet and manufacturer details for every material were searched and the components were checked. The literature was searched for information about the properties of these materials based on their composition. RESULTS: The safety data sheets and manufacturer details were imprecise with some manufacturers providing little detail on composition. From the publications reviewed, it is apparent that the materials used clinically are not optimized, and there is little evidence that the material chemistry and presentation aid the clinical technique in any way. CONCLUSIONS: There has been a rapid increase in materials identifying as bioceramics on the market. These materials have diverse chemistries, and some of the constituents are not declared. This may affect the clinical performance of these materials. CLINICAL SIGNIFICANCE: Smart materials developed on the clinical need which are appropriately tested are necessary for a paradigm shift in root canal obturation. It is important to use reputable materials that have been adequately researched in clinical practice.


Assuntos
Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/química , Resinas Epóxi/química , Guta-Percha/química , Cavidade Pulpar , Teste de Materiais , Compostos de Cálcio/química , Silicatos/química , Obturação do Canal Radicular/métodos
12.
Clin Oral Investig ; 27(5): 2221-2234, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36977761

RESUMO

OBJECTIVES: To evaluate the biocompatibility, physical and chemical properties of three pre-mixed calcium silicate-based sealers and an epoxy resin-based material were assessed. Pre-mixed sealers supposedly obtain water from the root canal moist to hydrate and set. MATERIALS AND METHODS: Polyethylene tubes were filled with the materials Bio-C Sealer Ion+, Bio-C Sealer, EndoSequence BC Sealer and AH Plus Jet, or left empty and surgically implanted in the subcutaneous tissue of Wistar rats. The animals were euthanised and the tubes and tissue were removed for histological analysis and scanning electron microscopy (SEM) coupled with energy-dispersive spectrometry (EDS). Materials' surface chemical characterisation was assessed using Raman spectroscopy and SEM/EDS. Flow, setting time (in two conditions), solubility, radiopacity and pH were also analysed. ANOVA and Bonferroni correction were performed for comparisons (P < 0.05). RESULTS: Inflammatory response observed in the tissues subsided from 7 to 30 days. Tungsten migration could be detected in the surrounding tissue following AH Plus Jet implantation. All calcium silicate-based sealers exhibited zirconium oxide (radiopacifier) and tricalcium silicate peaks before and after implantation. All materials exhibited flow values above 17 mm. An approximately tenfold difference was observed between the plaster- and metal-mould setting times of the calcium silicate cements indicating its sensitivity to moist variations and solubility above 8% was also observed for these materials. CONCLUSIONS: Pre-mixed materials exhibited variable setting time and solubility with a decreasing inflammatory response. CLINICAL RELEVANCE: The variable moist-dependant setting time with high solubility poses a concern for the clinical use of these pre-mixed sealers.


Assuntos
Materiais Restauradores do Canal Radicular , Ratos , Animais , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Tela Subcutânea , Ratos Wistar , Cromatografia Gasosa-Espectrometria de Massas , Compostos de Cálcio/química , Resinas Epóxi/química , Silicatos/química , Teste de Materiais
13.
Clin Oral Investig ; 27(11): 6757-6768, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37796335

RESUMO

OBJECTIVES: To investigate the effect of three different calcium silicate-based materials (CSBM) on the biological behavior of human periodontal ligament stem cells (hPDLSCs). METHODS: Eluates of Biodentine, NeoPutty and TheraCal PT prepared at 1:1, 1:2, and 1:4 ratios were extracted under sterile conditions. The cytotoxicity of the extracts to the hPDLSCs was assessed using the MTT assay. Scratch wound healing assay was utilized for assessing cell migration. Scanning electron microscopy was used to detect cell attachment and morphology. Calcium ion release was measured using inductively coupled plasma-optical emission spectrometry; the pH-value was evaluated with a pH-meter. ANOVA with post hoc Tukey test was used for statistical analysis. RESULTS: Cell viability was significantly higher for Biodentine and NeoPutty at day 1 with all dilutions (p < 0.05), while at day 3 and day 7 with dilutions 1:2 and 1:4; all materials showed similar behavior (p > 0.05). Biodentine had the highest percentage of cell migration into the scratched area at day 1 for all dilutions (p < 0.05). Stem cells were attached favorably on Biodentine and NeoPutty with evident spreading, and intercellular communications; however, this was not shown for TheraCal PT. Biodentine showed the highest pH values and calcium ion release (p < 0.05). CONCLUSIONS: The resin-free CSBM showed better performance and favorable biological effects on hPDLSCs and were therefore considered promising for usage as endodontic repair materials. CLINICAL SIGNIFICANCE: Proper selection of materials with favorable impact on the host stem cells is crucial to ensure outcome in different clinical scenarios.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/farmacologia , Cálcio/farmacologia , Teste de Materiais , Ligamento Periodontal , Compostos de Cálcio/farmacologia , Silicatos/farmacologia , Células-Tronco , Óxidos/farmacologia
14.
Odontology ; 111(1): 93-104, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35751826

RESUMO

The aim of this study was to evaluate the biocompatibility and immunoinflammatory response of the Sealepox and Sealepox-RP, based on interleukin (IL)-6, tumor necrosis factor (TNF)-α, and CD5 immunolabelling. The ProRoot MTA (PRMTA) was used for comparison. Polyethylene tubes (1.0-mm internal, 1.6-mm external diameter, and 10.0-mm length; ISO 10993) with or without (control) materials were randomly implanted in the dorsum of 35 rats (4 per rat). After 7, 15, 30, 60, and 90 days (n = 7), the tubes were removed for histological and immunohistochemical analysis. The Kruskal-Wallis and Dunn's test for non-parametric data and, ANOVA and Tukey test for parametric data were used (P < 0.05). Hematoxylin and eosin staining revealed that the concentration of inflammatory cells decreased over time with no differences between groups in all periods (P > 0.05). Regarding IL-6 immunostaining, there was no difference at 7 days (P > 0.05); all groups decreased over time, being faster for the PRMTA group and also, with no differences between groups in the last period (P > 0.05). For TNF-α, at 7 days there was no difference between groups (P > 0.05); there was an increase at 15 days for PRMTA and, at 30 and 60 days, for PRMTA and Sealepox compared to the control (P < 0.05). At 90 days, Sealepox RP showed the lowest immunostaining being similar to the control (P > 0.05). Regarding CD5 cells, at 7 days, there was high immunostaining for PRMTA compared to the control (P < 0.05); and significant reduction over time with difference for all groups at 30 and 60 days. (P < 0.05); Sealepox was similar to the control in all periods (P > 0.05). Sealepox RP showed the highest immunostaining at 15 days, being different from the control and PRMTA (P < 0.05); in the other periods it was similar to the control (P > 0.05). It can be concluded that Sealepox and Sealepox-RP were biocompatible and demonstrated similar immunoinflammatory response regarding IL-6, TNF-α, and CD5 compared to PRMTA.


Assuntos
Materiais Restauradores do Canal Radicular , Fator de Necrose Tumoral alfa , Ratos , Animais , Compostos de Cálcio , Interleucina-6 , Materiais Restauradores do Canal Radicular/farmacologia , Silicatos , Materiais Biocompatíveis , Teste de Materiais , Combinação de Medicamentos
15.
Odontology ; 111(4): 793-812, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37378833

RESUMO

The aim of this systematic review and meta-analysis (SRM) was to assess postoperative pain (PP) after endodontic treatment with bioceramic root canal sealer compared to AH Plus® sealer. This SRM was carried out in accordance with the items on the PRISMA 2020 checklist and Cochrane guidelines and registered in PROSPERO (CRD42021259283). Only randomized clinical trials (RCTs) were included. Meta-analysis was conducted using R software, the standardized means difference (SMD) measure of effect was calculated for quantitative variables, and the odds ratio (OR) for binary variables. The Cochrane tool (RoB 2.0) was used to assess the risk of bias, and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach was used to assess the quality of evidence. Qualitative and quantitative analysis included 18 and 17 studies, respectively. For quantitative variables, the bioceramic root canal sealer presented less occurrence of postoperative pain than the AH Plus® sealer in 24 h (SMD - 0.17 [- 0.34; - 0.01], p = 0.0340). For binary variables, there was no difference observed between the sealers evaluated, except for sealer extrusion where the bioceramic group had lower post-filling material extrusion (OR 0.52 [0.32; 0.84], p = 0.007). Regarding the risk of bias analysis, low risk was observed for most domains, except allocation that was considered unclear, while the certainty of evidence ranged from moderate to low. The results showed that bioceramics sealers reduced postoperative endodontic pain only after 24 h and showed less sealer extrusion compared to the AH Plus® sealer. However, more robust and standardized clinical trials are needed to confirm the results with less heterogeneity and higher quality of evidence.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Resinas Epóxi , Cavidade Pulpar , Ensaios Clínicos Controlados Aleatórios como Assunto , Obturação do Canal Radicular/métodos , Dor Pós-Operatória/prevenção & controle
16.
J Contemp Dent Pract ; 24(9): 707-714, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152946

RESUMO

AIM: The present study's objective was to compare the impact of CerasealR, total fill BC SealerR, Bio-C SealerR, AH Plus BioceramicR, and K-BiocerR on the elimination of a multispecies' endodontic biofilm at 3, 7 and 14 days. MATERIALS AND METHODS: A total of 20 freshly extracted, caries-free premolars were prepared for the study to create dentinal disks. For the multispecies biofilm formation, Enterococcus faecalis, Proteus mirabilis, Pseudomonas aeruginosa, and Candida albicans were cultured and used to inoculate hydroxyapatite discs. After incubation, the biofilms were placed on blotting papers in petri dishes with an orthodontic bend. Different root canal sealers, including CeraSeal, total Fill BC Sealer, Bio-C Sealer, AH Plus Bioceramic, K-Biocer, and Sealite, were injected into the bend, facilitating contact with the biofilms. The samples were divided into seven groups, including a negative control. At specific intervals, 3, 7, and 14 days, 3 biofilm samples from each group were collected, diluted, and plated on Agar media for colony counting and analysis. RESULTS: In all tested groups, the total bacterial count significantly decreased between day 3 and 14 (p < 0.05) with no statistically significant differences among the different sealers' groups at all-time points for the total bacterial count, E. faecalis count, and P. mirabilis count. However, Sealite demonstrated the most consistent effectiveness in reducing bacterial counts across multiple categories. The sealite group was capable of decreasing the C. albicans count significantly between day 3 and day 14 (p < 0.05) in comparison with the bioceramic groups. CONCLUSION: All sealers had antibacterial activity against the multispecies biofilm between day 3 and day 14. The ascending order of sealers in terms of their effectiveness in killing bacteria, based on the provided results, is as follows: Sealite, Bio-C Sealer, AH Plus, CeraSeal, TotalFill, and K-Biocer. However, there were no statistically significant differences in the bacterial counts among the different sealer groups at any time point. CLINICAL SIGNIFICANCE: The role of sealers in combating biofilm-associated infections highlights their potential clinical utility in preserving root canal health. Understanding the antimicrobial properties of these sealers is vital for informed decision-making in selecting the most effective materials for improved treatment outcomes and long-term success in endodontic procedures.


Assuntos
Anti-Infecciosos , Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/farmacologia , Resinas Epóxi , Cavidade Pulpar , Anti-Infecciosos/farmacologia , Biofilmes
17.
J Contemp Dent Pract ; 24(8): 610-619, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38193186

RESUMO

AIM: This review aimed to evaluate the in vitro studies done with regard to the cytotoxicity associated with mineral trioxide aggregate (MTA)-based root canal sealers. BACKGROUND: Root canal sealers are used during endodontic treatment as fillers to seal the gaps between the canal gutta-percha cone and canal walls. It is necessary to understand the cytotoxicity of these materials on human-derived cells as these materials interact with human cells periapically. REVIEW RESULTS: Six in vitro studies were chosen for review. In these selected studies, along with MTA-based root canal sealers, other sealers were tested for cytotoxicity on human periodontal ligament (PDL) stem cells, human PDL fibroblasts, and human osteoblast cells. Regarding cytotoxicity, the studies were diverse, and most were based on 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyl-2H-tetrazolium bromide) (MTT) assay. In general, the studies suggested that root canal sealers cause mild to severe cytotoxic effects and that several factors influence this effect, such as material setting time, concentration, and duration of exposure. CONCLUSION: All studies in the review indicated that MTA. Fillapex must be used cautiously as it exhibited the highest cytotoxic effect compared to other MTA-based and non-MTA-based sealers. CLINICAL SIGNIFICANCE: Endodontic sealers do serve the purpose of bridging the gaps between the gutta-percha cone and the canal wall but knowing its biocompatibility becomes important as the material is extruded beyond the apical foramen where it comes in contact with the surrounding tissues. The effect of sealers on the surrounding tissues affects the healing and prognosis of the treatment.


Assuntos
Compostos de Cálcio , Guta-Percha , Humanos , Compostos de Cálcio/toxicidade , Guta-Percha/toxicidade , Projetos de Pesquisa
18.
Int Endod J ; 55(7): 772-783, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35383959

RESUMO

AIM: To evaluate the physicochemical properties of five root canal sealers and assess their effect on an ex vivo dental plaque-derived polymicrobial community. METHODOLOGY: Dental plaque-derived microbial communities were exposed to the sealers (AH Plus [AHP], GuttaFlow Bioseal [GFB], Endoseal MTA [ESM], Bio-C sealer [BCS] and BioRoot RCS [BRR]) for 3, 6 and 18 h. The sealers' effect on the biofilm biomass and metabolic activity was quantified using crystal violet (CV) staining and MTT assay, respectively. Biofilm community composition and morphology were assessed by denaturing gradient gel electrophoresis (DGGE), 16S rRNA sequencing and scanning electron microscopy. The ISO6876:2012 specifications were followed to determine the setting time, radiopacity, flowability and solubility. Obturated acrylic teeth were used to assess the sealers' effect on pH. Surface chemical characterization was performed using SEM with coupled energy-dispersive spectroscopy. Data normality was assessed using the Shapiro-Wilk test. One-way anova and Tukey's tests were used to analyze data from setting time, radiopacity, flowability and solubility. Two-way anova and Dunnett's tests were used for the data analysis from CV, MTT and pH. 16S rRNA sequencing data were analyzed for alpha (Shannon index and Chao analysis) and beta diversity (Bray-Curtis dissimilarities). Differences in community composition were evaluated by analysis of similarity (p < .05). RESULTS: The sealers significantly influenced microbial community composition and morphology. All sealers complied with ISO6876:2012 requirements for setting time, radiopacity and flowability. Although only AHP effectively reduced the biofilm biomass, all sealers, except BRR, reduced biofilm metabolic activity. CONCLUSION: Despite adequate physical properties, none of the sealers tested prevented biofilm growth. Significant changes in community composition were observed. If observed in vivo, these changes could affect intracanal microbial survival, pathogenicity and treatment outcomes.


Assuntos
Placa Dentária , Materiais Restauradores do Canal Radicular , Biofilmes , Compostos de Cálcio/química , Cavidade Pulpar , Resinas Epóxi/química , Humanos , Teste de Materiais , RNA Ribossômico 16S , Materiais Restauradores do Canal Radicular/química , Materiais Restauradores do Canal Radicular/farmacologia , Silicatos/química
19.
Odontology ; 110(1): 127-137, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34382118

RESUMO

The aim of this study was to characterize a clonal human periodontal ligament (PDL) stem cell line (line 2-23 cells) cultured with root canal sealers based on methacrylate resin (SuperBond sealer; SB), bioactive glass (Nishika Canal Sealer BG; BG), or silicon (GuttaFlow 2; GF). The sealers were set in rubber molds to form sealer discs. Line 2-23 cells were cultured with or without the discs for 3 days. The cell viability was evaluated by direct cell counting and MTT assay. Inflammation-, PDL-, collagen-, and cell cycle-related gene expression was investigated by real-time RT-PCR. Collagen production was analyzed by Picro Sirius Red staining. Calcium ion concentration in the culture was measured by a QuantiChrom calcium assay kit. Line 2-23 cells survived when cultured with GF discs, but decreased cell viability was observed with SB and BG discs. The expression of inflammation-related genes was higher in cells cultured with SB discs, and expression of PDL-related genes was lower in cells exposed to SB and BG discs. These discs also down-regulated collagen production in line 2-23 cells. BG discs increased calcium ion concentration in the culture medium. Cells exposed to GF discs exhibited the same inflammation-, PDL-, collagen-, and cell cycle-related gene expression and collagen production as untreated cells. These results suggested that the characteristics of line 2-23 cells cultured with GF discs was highly resemble to untreated cells throughout the 3 days of the culture model.


Assuntos
Materiais Restauradores do Canal Radicular , Silício , Linhagem Celular , Cavidade Pulpar , Resinas Epóxi , Humanos , Teste de Materiais , Metacrilatos , Ligamento Periodontal , Materiais Restauradores do Canal Radicular/farmacologia
20.
Int J Mol Sci ; 23(22)2022 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-36430393

RESUMO

The aim of the study was to analyze the chemical−physical properties and bioactivity (apatite-forming ability) of three recently introduced premixed bioceramic root canal sealers containing varied amounts of different calcium silicates (CaSi): a dicalcium and tricalcium silicate (1−10% and 20−30%)-containing sealer with zirconium dioxide and tricalcium aluminate (CERASEAL); a tricalcium silicate (5−15%)-containing sealer with zirconium dioxide, dimethyl sulfoxide and lithium carbonate (AH PLUS BIOCERAMIC) and a dicalcium and tricalcium silicate (10% and 25%)-containing sealer with calcium aluminate, tricalcium aluminate and tantalite (NEOSEALER FLO). An epoxy resin-based sealer (AH PLUS) was used as control. The initial and final setting times, radiopacity, flowability, film thickness, open pore volume, water absorption, solubility, calcium release and alkalizing activity were tested. The nucleation of calcium phosphates and/or apatite after 28 days aging in Hanks balanced salt solution (HBSS) was evaluated by ESEM-EDX, vibrational IR and micro-Raman spectroscopy. The analyses showed for NeoSealer Flo and AH Plus the longest final setting times (1344 ± 60 and 1300 ± 60 min, respectively), while shorter times for AH Plus Bioceramic and Ceraseal (660 ± 60 and 720 ± 60 min, respectively). Radiopacity, flowability and film thickness complied with ISO 6876/12 for all tested materials. A significantly higher open pore volume was observed for NeoSealer Flo, AH Plus Bioceramic and Ceraseal when compared to AH Plus (p < 0.05), significantly higher values were observed for NeoSealer Flo and AH Plus Bioceramic (p < 0.05). Ceraseal and AH Plus revealed the lowest solubility. All CaSi-containing sealers released calcium and alkalized the soaking water. After 28 days immersion in HBSS, ESEM-EDX analyses revealed the formation of a mineral layer that covered the surface of all bioceramic sealers, with a lower detection of radiopacifiers (Zirconium for Ceraseal and AH Plus Bioceramic, Tantalum for NeoSealer Flo) and an increase in calcium, phosphorous and carbon. The calcium phosphate (CaP) layer was more evident on NeoSealer Flo and AH Plus Bioceramic. IR and micro-Raman revealed the formation of calcium carbonate on the surface of all set materials. A thin layer of a CaP phase was detected only on AH Plus Bioceramic and NeoSealer Flo. Ceraseal did not show CaP deposit despite its highest calcium release among all the tested CaSi-containing sealers. In conclusion, CaSi-containing sealers met the required chemical and physical standards and released biologically relevant ions. Slight/limited apatite nucleation was observed in relation to the high carbonation processes.


Assuntos
Materiais Restauradores do Canal Radicular , Materiais Restauradores do Canal Radicular/química , Cálcio/química , Cavidade Pulpar , Silicatos/química , Água/química , Apatitas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA