Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.053
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(8): 429, 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39001891

RESUMO

OBJECTIVES: To evaluate three temporary luting cements in terms of their restoration loss rates, biological interactions, esthetic properties, and handling characteristics. MATERIALS AND METHODS: 75 adults requiring fixed prosthodontics voluntarily participated in a single-blind, randomized controlled trial. After preparation, temporary restorations were luted with a randomly selected temporary luting cement (either Provicol QM Plus (PQP), Bifix Temp (BT), or Provicol QM Aesthetic (PQA)). Clinical examinations were performed one to two weeks after cementation. The following criteria were evaluated: tooth vitality, percussion, hypersensitivity, gingival bleeding, odor formation, esthetics, cement handling, removability, cleanability, and retention loss. Antagonistic teeth served as controls. Statistical analysis was performed using the paired t-test, one-way ANOVA, Pearson's chi-square and Fisher's exact test, where appropriate. RESULTS: The overall loss rate of temporary restorations was 16.0%, showing no cement-specific differences. Postoperative hypersensitivity occurred in 8% of cases regardless of cement type. Esthetic impairment was reported by 31% of the PQP-fixed restorations, compared with 4.0% and 4.2% of the BT and PQA-bonded restorations. Cement application was reported to be easy in 100% of cases, excess removal in 88-96%, depending on the cement used. CONCLUSIONS: The choice of luting material affects the esthetic appearance of a temporary restoration and should be considered, particularly in restorations in esthetically demanding areas. No significant differences between the cements were identified regarding biocompatibility, handling, and loss rate. CLINICAL RELEVANCE: Translucent cements can help to reduce color interferences, resulting in a more appealing appearance of the temporary restoration.


Assuntos
Cimentos Dentários , Estética Dentária , Humanos , Método Simples-Cego , Masculino , Feminino , Cimentos Dentários/química , Adulto , Pessoa de Meia-Idade , Restauração Dentária Temporária , Idoso , Cimentação/métodos
2.
J Shoulder Elbow Surg ; 33(8): 1755-1761, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38242528

RESUMO

BACKGROUND: Although cementation of humeral stems has long been considered the gold standard for anatomic shoulder arthroplasty (aTSA), cementless, or press-fit, fixation offers a relatively cheaper and less demanding alternative, particularly in the setting of a revision procedure. However, this approach has been accompanied by concerns of implant loosening and high rates of radiolucency. In the present study, we performed a propensity-matched comparison of clinical and patient-reported outcomes between cemented and cementless fixation techniques for aTSA. We hypothesized that cemented fixation of the humeral component would have significantly better implant survival while providing comparable functional outcomes at final follow-up. METHODS: This study was a retrospective comparison of 50 shoulders undergoing aTSA: 25 using cemented humeral fixation vs. 25 using press-fit humeral fixation. Patients in the 2 groups were propensity matched according to age, sex, and preoperative American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) score. Primary outcome measures included range of motion (ROM) (forward elevation, external rotation, internal rotation), patient-reported outcomes (ASES, Simple Shoulder Test [SST], visual analog scale [VAS]), and implant survival. RESULTS: At baseline, the 2 fixation groups were similar in regard to age, sex, body mass index, preoperative ASES score, and surgical indication. Mean follow-up was 11.7 ± 4.95 years in the cemented cohort and 9.13 ± 3.77 years in the press-fit cohort (P = .045). Both groups demonstrated significant improvements postoperatively in all included ROM and patient-reported outcomes. However, press-fit patients reported significantly better VAS, ASES, and SST scores. Mean VAS pain score was 1.1 ± 1.8 in press-fit patients and 3.2 ± 3.0 in cemented patients (P = .005). The mean ASES score was 87.7 ± 12.4 in press-fit patients and 69.5 ± 22.7 in cemented patients (P = .002). Lastly, the mean SST score was 9.8 ± 3.1 in press-fit patients and 7.7 ± 3.7 in cemented patients (P = .040). Both fixation techniques provided lasting implant survivorship with only a single revision operation in each of the cohorts. CONCLUSION: Herein, we provide a propensity-matched, long-term comparison of patients receiving anatomic shoulder arthroplasty stratified according to humeral stem fixation technique. The results of this analysis illustrate that both types of humeral fixation techniques yield durable and significant improvements in shoulder function with similar rates of survival at 10 years of follow-up.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Amplitude de Movimento Articular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Seguimentos , Pessoa de Meia-Idade , Artroplastia do Ombro/métodos , Prótese de Ombro , Cimentação , Cimentos Ósseos , Úmero/cirurgia , Pontuação de Propensão , Falha de Prótese , Articulação do Ombro/cirurgia , Resultado do Tratamento
3.
J Arthroplasty ; 39(8): 2007-2013, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38355062

RESUMO

BACKGROUND: Periprosthetic fractures are rare but serious complications of unicompartmental knee arthroplasty (UKA). Although cementless UKA has a lower risk of loosening than cemented, there are concerns that tibial fracture risk may be higher given the reliance on interference fit for primary stability. The risk of fracture and the effect of surgical fixation are currently unknown. We compared the periprosthetic fracture rate following cemented and cementless UKA surgery. METHODS: A total of 14,122 medial mobile-bearing UKAs (7,061 cemented and 7,061 cementless) from the National Joint Registry and Hospital Episodes Statistics database were propensity score-matched. Cumulative fracture rates were calculated and Cox regressions were used to compare fixation groups. RESULTS: The three-month periprosthetic fracture rates were similar (P = .80), being 0.10% in the cemented group and 0.11% in the cementless group. The fracture rates were highest during the first three months postoperatively, but then decreased and remained constant between one and 10 years after surgery. The one-year cumulative fracture rates were 0.2% (confidence interval [CI]: 0.1 to 0.3) for cemented and 0.2% (CI: 0.1 to 0.3) for cementless cases. The 10-year cumulative fracture rates were 0.8% (CI: 0.2 to 1.3) and 0.8% (CI: 0.3 to 1.3), respectively. The hazard ratio during the whole study period was 1.06 (CI: 0.64 to 1.77; P = .79). CONCLUSIONS: The periprosthetic fracture rate following mobile bearing UKA surgery is low, being about 1% at 10 years. There were no significant differences in fracture rates between cemented and cementless implants after matching. We surmise that surgeons are aware of the higher theoretical risk of early fracture with cementless components and take care with tibial preparation. LEVELS OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Cimentos Ósseos , Prótese do Joelho , Fraturas Periprotéticas , Sistema de Registros , Humanos , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/efeitos adversos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Masculino , Idoso , Feminino , Prótese do Joelho/efeitos adversos , Pessoa de Meia-Idade , Irlanda do Norte/epidemiologia , Inglaterra/epidemiologia , País de Gales/epidemiologia , Fraturas da Tíbia/cirurgia , Desenho de Prótese , Idoso de 80 Anos ou mais , Cimentação , Falha de Prótese
4.
J Prosthet Dent ; 131(2): 252.e1-252.e8, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38042643

RESUMO

STATEMENT OF PROBLEM: Veneer preparation designs impact veneer accuracy. However, whether a modified design could reduce absolute margin discrepancy and marginal overhangs is unclear. PURPOSE: The purpose of this in vitro study was to investigate whether a modified veneer preparation design enhances the absolute margin discrepancy and marginal overhang. MATERIAL AND METHODS: The absolute margin discrepancy and the marginal overhang of 3 different veneer preparation designs on a typodont tooth (n=20): feather edge, shoulder, and shoulder with wings were measured. The feather edge design was prepared first and subsequently modified to create the shoulder and shoulder with wings preparations. Ceramic veneers were fabricated using computer-aided design and computer-aided manufacture with each veneer assessed for fit before cementation. Ten specimens were cut vertically, and 10 were cut horizontally in each group. The absolute margin discrepancy and marginal overhangs were measured for each cross-section with scanning electron microscopy. Descriptive data analysis and hypothesis testing were conducted using the nonparametric Kruskal Wallis test (α=.05). RESULTS: On the vertical sections, the shoulder with wings preparation had the best absolute margin discrepancy and overhang. The design was also best for mesial overhang and mesial absolute margin discrepancy when measuring horizontally. CONCLUSIONS: The shoulder with wings preparation design produced the smallest cervical absolute margin discrepancy and overhang. This design also produced absolute margin discrepancy and overhangs comparable with those of the shoulder design in the proximal areas.


Assuntos
Facetas Dentárias , Preparo Prostodôntico do Dente , Cerâmica , Desenho Assistido por Computador , Cimentação , Planejamento de Prótese Dentária , Adaptação Marginal Dentária , Porcelana Dentária , Coroas
5.
Arch Orthop Trauma Surg ; 144(6): 2673-2681, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38830998

RESUMO

INTRODUCTION: Cemented hip hemiarthroplasty is a routine surgical option for elderly neck of femur (NOF) fractures. It is uncertain if quality of cementing has any effect on functional outcomes. The aim of this study was to determine if the quality of cementing would affect short term functional outcomes in elderly neck of femur fractures. MATERIALS AND METHODS: Retrospective analysis of 637 single-centre cemented hip hemiarthroplasties from 2014 to 2021 was performed. Each post-operative radiograph was double-read by 2 authors (1 resident and 1 fellowship trained surgeon) to determine quality of cementing via the Barrack grading. Disagreements were reviewed by a third reader. Cement grades were grouped as Optimal (Barrack grade A-B), or Suboptimal (Barrack grade C-D). Functional outcomes were compared using mobility (community- or home-ambulant), assistance required for mobility, and Modified Barthel Index (MBI). Surgical parameters were compared between the groups. RESULTS: There were 429 Optimal and 208 Suboptimal cases of cementing performed. There was no difference in age, American Society of Anesthesiologists score, mobility, assistance required, and MBI score pre-operatively (p > 0.05). Patients in the "Suboptimal" cementing group had a higher Charlson Comorbidity Index (CCI) score (p < 0.001). At 1 year post-operation, there was no significant difference between "Optimal" and "Suboptimal" cementing with regards to the proportion of community ambulators (30.2% vs. 25.7%, p = 0.252), walking independence (independent walkers (19.8% vs.17.3%), independent walkers with aids (41.3%vs.42.1%), walker with caregiver assistance (29.2%vs.33.7%), wheelchair-bound (9.6%vs.6.9%), p = 0.478), and distribution of MBI score (81.1%vs.82.2% achieving MBI > 60, p = 0.767). There was no significant difference in the proportion of patients with postoperative delirium (7.9% vs. 5.8, p = 0.324) or 1-year mortality rates (3.5% vs. 2.9%, p = 0.685). Except for stem design (12.2% tapered vs 20.1% collared; p = 0.011), no other surgical parameters were significantly different. The kappa value for inter-reader agreement was "substantial" at 0.727 (95% CI 0.682-0.772) (p < 0.001). CONCLUSION: Quality of cementing in cemented hip hemiarthroplasty for elderly NOF fractures does not affect the short-term functional outcomes. In low demand patients and patients at risk of BCIS, optimal cementing may not be necessary to achieve similar short-term functional outcomes. Further studies should be conducted to determine the effect of sub-optimal cementing on long-term functional outcomes.


Assuntos
Cimentos Ósseos , Fraturas do Colo Femoral , Hemiartroplastia , Humanos , Hemiartroplastia/métodos , Estudos Retrospectivos , Fraturas do Colo Femoral/cirurgia , Feminino , Masculino , Idoso de 80 Anos ou mais , Idoso , Resultado do Tratamento , Cimentação
6.
Arch Orthop Trauma Surg ; 144(5): 2019-2026, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38581441

RESUMO

BACKGROUND: Routine total hip arthroplasty (THA) using a short cemented stem as compared with a standard length cemented stem may have benefits in terms of stress distribution, bone preservation, stem subsidence and ease of revision surgery. Two senior arthroplasty surgeons transitioned their routine femoral implant from a standard 150 mm Exeter V40 cemented stem to a short 125 mm Exeter V40 cemented stem for all patients over the course of several years. We analysed revision rates, adjusted survival, and PROMS scores for patients who received a standard stem and a short stem in routine THA. METHODS: All THAs performed by the two surgeons between January 2011 and December 2021 were included. All procedures were performed using either a 150 mm or 125 mm Exeter V40 stem. Demographic data, acetabular implant type, and outcome data including implant survival, reason for revision, and post-operative Oxford Hip Scores were obtained from the New Zealand Joint Registry (NZJR), and detailed survival analyses were performed. Primary outcome was revision for any reason. Reason for revision, including femoral or acetabular failure, and time to revision were also recorded. RESULTS: 1335 THAs were included. 516 using the 150 mm stem and 819 using the 125 mm stem. There were 4055.5 and 3227.8 component years analysed in the standard stem and short stem groups respectively due to a longer mean follow up in the 150 mm group. Patient reported outcomes were comparable across all groups. Revision rates were comparable between the standard 150 mm stem (0.44 revisions/100 component years) and the short 125 mm stem (0.56 revisions/100 component years) with no statistically significant difference found (p = 0.240). CONCLUSION: Routine use of a short 125 mm stem had no statistically significant impact on revision rate or PROMS scores when compared to a standard 150 mm stem. There may be benefits to routine use of a short cemented femoral implant.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Prótese de Quadril , Medidas de Resultados Relatados pelo Paciente , Desenho de Prótese , Reoperação , Humanos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Reoperação/estatística & dados numéricos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Falha de Prótese , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos , Cimentação
7.
BMC Oral Health ; 24(1): 586, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773502

RESUMO

BACKGROUND: Cement spacer is essential for compensating deformation of zirconia restoration after sintering shrinkage, allowing proper seating and better fracture resistance of the restoration. Studies assessing the effect of cement spacer on fit accuracy and fracture strength of zirconia frameworks are missing in the literature. Therefore, the aim of this study was to evaluate the effect of different cement spacer settings on fit accuracy and fracture strength of 3-unit and 4-unit zirconia frameworks. METHODS: Sixty standardized stainless-steel master dies were manufactured with 2 prepared abutments for fabricating 3-unit and 4-unit zirconia frameworks. The frameworks were assigned into 6 groups (n = 10) according to cement spacer setting (30 µm, 50 µm, and 80 µm) as follows: 3-unit frameworks; 3u-30, 3u-50, 3u-80, and 4-unit frameworks; 4u-30, 4u-50, and 4u-80. The frameworks were assessed for fit accuracy with the replica method. The specimens were cemented to their corresponding dies, and the fracture strength was measured in a universal testing machine. The Weibull parameters were calculated for the study groups and fractured specimens were inspected for failure mode. Two-Way ANOVA followed by Tukey test for pairwise comparison between study groups (α = 0.05). RESULTS: The cement spacer had a significant effect on both fit accuracy and fracture strength for 3-unit and 4-unit frameworks. The 50 µm spacer had significantly better fit accuracy followed by 80 µm, and 30 µm spacers. Both 50 µm and 80 µm spacers had similar fracture strength, and both had significantly better strength than 30 µm spacer. CONCLUSIONS: For both 3-unit and 4-unit zirconia frameworks, 50 µm cement spacer can be recommended over 30 µm and 80 µm spacers for significantly better fit accuracy and adequate fracture strength.


Assuntos
Análise do Estresse Dentário , Teste de Materiais , Zircônio , Zircônio/química , Cimentos Dentários/química , Falha de Restauração Dentária , Humanos , Cimentação/métodos
8.
BMC Oral Health ; 24(1): 670, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38851731

RESUMO

OBJECTIVE: To investigate the fracture resistance and failure modalities of anterior endocrown restorations fabricated employing diverse ceramic materials, and bonded using various cementation methodologies. MATERIALS AND METHODS: Forty maxillary central incisors were divided into two main groups based on the ceramic materials used; GroupI (Zir): zirconia endocrwons (Zolid HT+, Ceramill, Amanngirrbach) and GroupII (E-Max): e-max endocrowns (IPS e.max CAD, Ivoclar Vivadent). Both groups were further split into two subgroups depending on the cementation protocols; subgroup IA "ZirMDP": endocowns cemented with MDP primer + MDP resin cement, subgroup IB (ZirNon-MDP): cemented with MDP primer + non-MDP resin cement, subgroup IIA (E-maxMDP): cemented with MDP primer + MDP resin cement, subgroup IIB (E-maxNon-MDP): cemented with MDP primer + non-MDP resin cement. (n = 10/subgroup). Endocrowns were manufactured using CAD/ CAM. Teeth were subjected to 10,000 thermal cycles. The fracture test was performed at 45o with a palatal force direction until the fracture occurred. Test results were recorded in Newton. The failure mode was examined using a stereomicroscope. A One-way ANOVA test was utilized to compare different groups regarding fracture strength values. Tukey`s Post Hoc was utilized for multiple comparisons. RESULTS: The comparative analysis of fracture strength across the diverse groups yielded non-significant differences, as indicated by a p-value exceeding 0.05. Nonetheless, an observable trend emerged regarding the mode of failure. Specifically, a statistically significant prevalence was noted in fractures localized within the endocrown/tooth complex below the cementoenamel junction (CEJ) across all groups, except for Group IIB, "E-max Non-MDP," where fractures within the endocrown/tooth complex occurred above the CEJ. CONCLUSIONS: Combining an MDP-based primer with an MDP-based resin cement did not result in a significant effect on the anterior endocrown fracture strength. CLINICAL RELEVANCE: Regardless of the presence of the MDP monomer in its composition, adhesive resin cement achieved highly successful fracture strength when used with MDP-based ceramic primers. Additionally, ceramic materials exhibiting elastic moduli surpassing those of dentin are discouraged due to their propensity to induce catastrophic fractures within the tooth structure.


Assuntos
Cimentação , Análise do Estresse Dentário , Incisivo , Humanos , Cimentação/métodos , Técnicas In Vitro , Cimentos de Resina/química , Zircônio/química , Teste de Materiais , Coroas , Falha de Restauração Dentária , Cerâmica/química , Materiais Dentários/química , Desenho Assistido por Computador , Porcelana Dentária/química
9.
BMC Oral Health ; 24(1): 617, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807096

RESUMO

BACKGROUND: Retrieval of cement-retained implant-supported restorations is intriguing in cases of screw loosening. Detecting the estimated size of the screw access hole (SAH) could decrease destruction to the prosthesis and preserve the crown. OBJECTIVES: To precisely localize loose implant screws through cemented crowns to reduce crown damage after screw loosening. MATERIALS AND METHODS: In this in vitro study, 60 cement-retained implants supported 30 zirconia-based, and 30 ceramics fused to metal (CFM) lower molar crowns were invented, and each was subdivided into three subgroups (10 each). In group I (AI/BI) (control), SAH was created with the aid of orthopantomography (OPG). In contrast, in group II (zirconia-crown), SAH was created with the aid of CBCT + 3D printed surgical guide with a 2 mm metal sleeve in subgroups IIA/IIIA and CBCT + MAR was used to develop SAH in subgroups IIB/IIIB. SEM and Micro-CT scanned the SAH openings to determine the diameter of the hole, cracking, chipping, and chipping volume. RESULTS: Regarding the effect of plane CBCT and CBCT + MAR on prepared crowns, a highly significant association between group I with group II (p = 0.001) and group III (p = 0.002) was detected. Regarding the cracking of SAH, significant differences between the zirconium crown and CFM restoration (p = 0.009) were found, while for the chipping, no significant association was seen between groups (p = 0.19). CONCLUSIONS: CBCT, either as a plane CBCT or with MAR, significantly improved the accuracy of drilling the screw channel and decreased injury to the existing restoration and abutment, aiding in better localization of SAH in loosened implant abutment screws.


Assuntos
Coroas , Prótese Dentária Fixada por Implante , Técnicas In Vitro , Humanos , Falha de Restauração Dentária , Microtomografia por Raio-X , Cimentos Dentários , Tomografia Computadorizada de Feixe Cônico , Cimentação/métodos , Zircônio , Microscopia Eletrônica de Varredura , Parafusos Ósseos
10.
J Prosthodont ; 33(3): 266-272, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36951153

RESUMO

PURPOSE: To investigate the distribution of marginal excess cement in vented and non-vented crowns and evaluate the effect of clinical cleaning procedures on the reduction of excess cement. MATERIALS AND METHODS: Forty models with implant analogs in the position of the right maxillary first molar were divided into four groups (n = 10/group, vented/non-vented crowns with or without cleaning procedures). The abutment finish lines were placed 1 mm below the artificial gingiva buccally, mesially, and distally and at the gingival level palatally. A standardized amount (20 mg) of resin cement was applied in a thin layer to the intaglio surface of zirconia vented and non-vented crowns. The excess cement was removed by a dental explorer in groups with cleaning procedures. The distribution (area and depth) of the marginal excess cement was measured at each quadrant (buccal, mesial, palatal, and distal) for all study samples. The data were analyzed using descriptive and analytical statistics (ɑ = 0.05). RESULTS: The area and depth values of the excess cement in each quadrant in the vented group were significantly smaller than that in the non-vented group, both with and without cleaning (p < 0.001). Cleaning procedures significantly reduced the area of excess cement in both vented and non-vented groups (all, p < 0.001 except for p < 0.05 at the buccal aspect of the vented group). The depth of excess cement in the vented group was significantly decreased with cleaning in the buccal quadrant compared with that without cleaning (p < 0.01). However, the depth of excess cement of the non-vented group was significantly increased with cleaning in all quadrants compared with that without cleaning (all, p < 0.001 except for p < 0.05 at the distal aspect). CONCLUSIONS: Crown venting significantly reduced the area and depth of the marginal excess cement in vitro. Cleaning procedure with a dental explorer significantly reduced the area of marginal excess cement in vitro; however, the excess cement can be pushed deeper in the non-vented group.


Assuntos
Cimentação , Implantes Dentários , Zircônio , Cimentação/métodos , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Coroas , Prótese Dentária Fixada por Implante , Dente Suporte
11.
Gen Dent ; 72(4): 50-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38905605

RESUMO

Patients are always looking for conservative, esthetic, and long-lasting dental restorations, and the technique used directly influences the longevity of the treatment. The location of the restoration in the mouth and the extent of the decay influence the treatment choice. The larger the dimensions of the cavity preparation, the greater the difficulties in restoring the tooth using direct techniques. The semidirect technique, when indicated, can achieve satisfactory results. It is a relatively easy procedure, consisting of tooth preparation to receive an indirect restoration, fabrication of an alginate impression, fabrication of the composite resin restoration on a flexible cast, cementation, removal of excess cement, and occlusal adjustment. The aim of this case report is to present a viable alternative to direct and indirect restorations for posterior teeth with extensive decay. The article describes the extraoral semidirect technique for fabricating a composite resin restoration, highlighting its indications and discussing advantages and disadvantages.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Humanos , Resinas Compostas/uso terapêutico , Restauração Dentária Permanente/métodos , Seguimentos , Feminino , Cárie Dentária/terapia , Masculino , Preparo da Cavidade Dentária/métodos , Cimentação/métodos , Materiais Dentários/uso terapêutico , Materiais Dentários/química , Dente Molar , Técnica de Moldagem Odontológica
12.
Eur J Orthop Surg Traumatol ; 34(4): 1825-1830, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38429555

RESUMO

INTRODUCTION: There is continued debate regarding the survivorship and revision rate of cementless versus cemented total knee arthroplasty (TKA) prostheses. This includes the assessment of early revision surgery due to aseptic loosenings and periprosthetic joint infections (PJIs). Studies have not always taken into account the impact of comorbidities, such as diabetes, obesity, and tobacco. Therefore, we compared revisions in a large population of patients undergoing cemented or cementless TKAs at 90 days, 1 year, and 2 years. METHODS: A review of an administrative claims database was used to identify patients undergoing primary TKA, either cementless (n = 8,890) or cemented (n = 215,460), from October 1, 2015 to October 31, 2020. Revision surgery for PJI and aseptic loosening were identified with diagnosis and associated procedural codes at 90 days, 1 year, and 2 years and then compared between groups. A propensity matched-analysis was performed for age, sex, Charles Comorbidity Index (CCI) > 3, alcohol abuse, tobacco use, obesity, and diabetes. Chi square tests assessed statistical significance of differences in the matched cohorts using odds ratios (ORs) with 95% confidence intervals (CIs). A P < 0.05 was defined as statistically significant. RESULTS: Cementless TKA was associated with similar revisions rates due to PJIs at 90 days (OR, 1.04, 95% CI 0.79-1.38, p = 0.83), 1 year (OR, 0.93, 95% CI 0.75-1.14, p = 0.53, and 2 years (OR, 0.87, 95% CI 0.73-1.05, p = 0.17) in comparison to the cemented TKA cohort. The odds ratio of revision due to aseptic loosening was similar as well at 90 days (OR, 0.67, 95% CI 0.34-1.31, 0.31), 1 year (OR, 1.09, 95% CI 0.73-1.61, p = 0.76), and 2 years (OR, 1.00, 95% CI 0.73-1.61, p = 0.99). CONCLUSIONS: This study found a comparable risk of PJI and aseptic loosening in cementless and cemented TKA when controlling for several comorbidities, such as tobacco, diabetes, and alcohol. Therefore, with proper patient selection, cementless TKAs can be performed with expectation of low risks of infections and aseptic loosenings.


Assuntos
Artroplastia do Joelho , Cimentos Ósseos , Pontuação de Propensão , Falha de Prótese , Infecções Relacionadas à Prótese , Reoperação , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Feminino , Masculino , Reoperação/estatística & dados numéricos , Idoso , Falha de Prótese/etiologia , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Comorbidade , Cimentação
13.
Eur J Orthop Surg Traumatol ; 34(4): 1927-1935, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462554

RESUMO

BACKGROUND: Periprosthetic femoral fractures (PFF) carry significant morbidity following arthroplasty for femoral neck fracture (FNF). This study assessed fracture complications following arthroplasty for FNF and the effect of cement fixation of the femoral component on intraoperative and post-operative PFF. METHODS: Between February 2014 and September 2021, 740 patients with a FNF who underwent arthroplasty were analyzed for demographics, surgical management, use of cement for fixation of the femoral component, and subsequent PFF. Variables were compared with Mann-Whitney or Chi-square as appropriate. Multivariate logistic regression was used to assess independent risk factors associated with intraoperative or post-operative PFF. RESULTS: There were 163 THAs (41% cemented) and 577 HAs (95% cemented). There were 28 PFFs (3.8%): 18 post-operative and 10 intraoperative. Fewer post-operative PFFs occurred with cemented stems (1.63% vs. 6.30%, p = 0.002). Mean time from surgery to presentation with post-operative PFF was 14 months (0-45 months). Mean follow-up time was 10.3 months (range: 0-75.7 months). In multivariate regression, use of cement and THA was independently associated with decreased post-operative PFF (cement: OR 0.112, 95% CI 0.036-0.352, p < 0.001 and THA: OR 0.249, 95% CI 0.064-0.961, p = 0.044). More intraoperative fractures occurred during THA (3.68% vs. 0.69%, p = 0.004) and non-cemented procedures (5.51% vs. 0.49%, p < 0.001). In multivariate regression, use of cement was protective against intraoperative fracture (OR 0.100, CI 0.017-0.571, p = 0.010). CONCLUSIONS: In patients with a FNF treated with arthroplasty, cementing the femoral component is associated with a lower risk of intraoperative and post-operative PFF. Choice of procedure may be based on patient factors and surgeon preference.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Fraturas do Colo Femoral , Fraturas Periprotéticas , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/prevenção & controle , Fraturas Periprotéticas/cirurgia , Masculino , Feminino , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Idoso , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Cimentação
14.
Eur J Orthop Surg Traumatol ; 34(5): 2573-2580, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38695885

RESUMO

PURPOSE: According to Vancouver classification, B2 type fractures are most often treated with removal of the loose stem and implantation of a long stem that bypasses the fracture site. However, there is a controversy about the stem fixation that should be used: cemented or cementless. Hence, this study aims to compare cemented and cementless stems in prosthetic revision due to Vancouver B2 (VB2) periprosthetic hip fracture. METHODS: A retrospective study was done including all the patients treated with stem exchange due to VB2 periprosthetic hip fracture in a tertiary hospital between 2015 and 2022. Patients were divided into two groups according to the stem fixation used: cemented or cementless. Functional outcomes, hospital stay, surgical time, complication rate, and mortality were compared between the two groups of patients. RESULTS: Of the 30 included patients, 13 (43.4%) were treated with cementless stems and 17 (56.7%) with cemented stems. There were no statistically significant differences in age, gender, anesthesia risk scale (ASA) or functional capacity prior to the intervention. Patients treated with cementless stems had a higher complication and reintervention rate than those treated with cemented stems: 62 and 45% versus 34 and 6% (p = 0.035; p = 0.010), respectively. Furthermore, in the group of cementless stems a higher proportion of non-union was found (53.8% vs. 17.6%; p = 0.037). Also, the hospital stay (33 vs. 24 days; p = 0.037) and the time to full weight-bearing (21 days vs. 9 days; p < 0.001) were longer in the cementless stem group. CONCLUSION: Cemented fixation in stem revision due to Vancouver B2 periprosthetic hip fracture could be an optimal option with faster recovery which could decrease the rate of complications and reintervention, without compromising the fracture healing and patient mortality. Thus, this option can be considered when an anatomical reduction can be obtained, especially in elderly patients with multiple comorbidities in which a less aggressive surgical option should be considered.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Fraturas do Quadril , Prótese de Quadril , Fraturas Periprotéticas , Reoperação , Humanos , Masculino , Feminino , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Estudos Retrospectivos , Idoso , Artroplastia de Quadril/métodos , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos/uso terapêutico , Fraturas do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Idoso de 80 Anos ou mais , Tempo de Internação/estatística & dados numéricos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/etiologia , Duração da Cirurgia , Falha de Prótese , Desenho de Prótese , Cimentação
15.
Stomatologiia (Mosk) ; 103(3): 26-30, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38904556

RESUMO

OBJECTIVE: The aim of the study is measuring the magnitude and determining the method of finger pressure exerted by doctors on ceramic veneers during their fixation. MATERIAL AND METHODS: A simulation model was designed in order to measure the volume of finger pressure. Veneers were produced for 2 central incisors. Doctors alternately placed veneers on the model and applied pressure on them for 20 seconds simulating the clinical stage of cementing. The operator recorded the maximum readings of the scales and entered the result on the research protocol. In addition, it was recorded which finger the doctor exerts on the veneer during its cementing to ensure a tight fit: thumb or index finger. RESULTS: The values obtained during cementation of 54% doctors ranged up to 1 kg, 27% of doctors from 1 to 2 kg and only 19% more than 2 kg. 80% of doctors applied the main pressure on the veneer using their thumb, while the pressure force was 1.4 kg. For those doctors who pressed the veneer to the tooth with their index finger, the impact value was 0.8 kg. CONCLUSION: The finger pressure on the veneer during cementation applied by dentists varies, the average pressure on the veneers was about 1.5 kg. The amount of pressure on cement during laboratory tests of cements for fixing veneers differs from clinical values many times. The development of a veneers fixation protocol, taking into account the conducted research, will ensure a reliable and accurate fit of the veneer at the stage of its cementing.


Assuntos
Cerâmica , Facetas Dentárias , Pressão , Humanos , Cerâmica/química , Cimentação/métodos , Dedos , Cimentos Dentários/química
16.
Clin Oral Implants Res ; 34(1): 33-41, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36278423

RESUMO

OBJECTIVES: To evaluate the association between different vertical levels of the abutment margin and residual cement prevalence in cement-retained implant restorations with customized abutments. METHODS: One hundred and nine single-unit cement-retained implant restorations with a screw-access channel were included. The crowns were intraorally cemented on the abutments, and excess cement was removed. The abutment-crown complex was unscrewed, and the abutment-crown complex and peri-implant tissue were photographed. Residual cement presence was recorded by dividing the abutment-crown complex and peri-implant tissue into four quadrants: mesial, distal, buccal, and lingual. The prevalence of residual cement was compared according to the height of the custom abutment margin of the corresponding quadrant. A multilevel model was used for statistical analysis (α = .05). RESULTS: Cement remnants were discovered on 72.48% of the dental implants. When the restoration quadrants were compared, cement remnants were present on 51.38%, 39.45%, 20.18%, and 17.43% of the mesial, distal, buccal, and lingual surfaces, respectively (p < .01). Regarding the abutment margin level, cement residues were found in 60.22% and 61.4% of the 0.5 mm subgingival and ≥1 mm subgingival margin groups, respectively, which were significantly more than those in the supragingival (23.65%) and equigingival (26.59%) margin groups (p < .01). After adjustment for confounding factors, the adjusted odds ratio (with 95% confidence interval) for residual cement in the subgingival margin groups was 3.664 (1.71, 7.852) when compared to the supragingival and equigingival margin groups. CONCLUSIONS: The risk of residual cement occurrence was 3.66-fold higher with a subgingival abutment margin than with supragingival and equigingival abutment margins.


Assuntos
Cimentação , Implantes Dentários , Dente Suporte , Prótese Dentária Fixada por Implante , Cimentos Dentários , Cimentos de Ionômeros de Vidro/química , Coroas
17.
Clin Oral Investig ; 27(3): 1071-1078, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36030454

RESUMO

OBJECTIVES: To evaluate the longevity of metal-ceramic single crowns cemented onto resin composite prosthetic cores using a self-adhesive resin cement in a prospective clinical descriptive study. METHODS: A total of 152 teeth were endodontically treated and received resin composite prosthetic cores and metal-ceramic crowns cemented with a self-adhesive resin cement. The patients included in the sample were recalled for clinical and radiography evaluation in an up-to-106-month period after the final cementation procedures, with an average of 62 months of follow-up. 91.5% of the sample (142 teeth) were evaluated regarding the treatment survival rate, analyzed considering the loss of crown retention (crown debonding) and tooth loss as the primary outcome. In addition, post debonding, and root fracture occurrences were also recorded as secondary outcomes to evaluate the success rate of the prosthetic treatment. The aesthetic parameters were also evaluated according to the FDI criteria. The Kaplan-Meier method and Cox regression with 95% confidence interval were applied for the statistical analysis. RESULTS: Regarding the primary outcome, the metal-ceramic crowns cemented with self-adhesive resin cement presented a high survival rate (91.5%), with 8 crown debondings and 3 tooth losses (1 due to caries and 2 due to periodontal disease) occurring after the evaluation period. For secondary outcomes, 9 root fractures and 4 post debondings occurred, generating a success rate of 72%. All crowns had a score 1 on the FDI criteria, indicating that they were clinically excellent or very good regarding the aesthetic parameters. CONCLUSION: The metal-ceramic crowns luted with a self-adhesive resin cement presented a survival rate of 91.5% after an average of 62 months of follow-up. Furthermore, the restorations remained aesthetically satisfactory over time, without changes that would indicate prosthetic retreatment. A success rate of 72% was obtained considering the secondary outcome, mainly related to intraradicular retainer failures (root fractures or post debonding). CLINICAL SIGNIFICANCE: The self-adhesive resin cement is clinically indicated for cementation of metal-ceramic crowns onto resin composite prosthetic cores.


Assuntos
Cimentos Dentários , Cimentos de Resina , Humanos , Seguimentos , Estética Dentária , Resinas Compostas , Coroas , Cimentação/métodos , Cerâmica , Teste de Materiais , Falha de Restauração Dentária
18.
Clin Oral Investig ; 27(5): 2197-2206, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36894666

RESUMO

OBJECTIVES: The objective of this study is to evaluate the longevity of two fiber post cementation strategies in a prospective, multicenter, non-inferiority, double-blind randomized controlled trial. METHODS: A total of 152 teeth, with adequate endodontic treatment and loss of coronal structure and bilateral simultaneous posterior occlusal contacts, were randomly allocated to receive glass fiber posts cemented with a conventional cementation strategy (CRC group: adhesive system + resin cement) (Adper Single Bond + RelyX ARC; 3 M-ESPE) or a self-adhesive cementation strategy (SRC group: self-adhesive resin cement; RelyX U100/U200; 3 M-ESPE). The patients were recalled annually for clinical and radiographical evaluation with a 93% recall rate (142 teeth, with 74 at CR groups and 68 at SRC group). The primary outcome was survival rate, considering the fiber post debonding (loss of retention). The secondary outcome included the success rate of the prosthetic treatment with crown debonding, post fracture, and tooth loss (not related to post failure). Both outcomes were evaluated annually. The Kaplan-Meier method and Cox regression with 95% confidence interval were used for the statistical analysis. RESULTS: For the primary outcome (failures directly related to fiber posts cementation strategy), there were 4 fiber post debondings (2 per group), 8 root fractures (3 for SRC group and 5 for CRC group), and one mixed failure (debonding combined with root fracture for CRC), with both strategies presenting similar survival rates (p = 0.331), with 88.9% for the CRC group and 90.9% for the SRC group. For the secondary outcome (failures not related to fiber post cementation strategies), there were 8 crown debondings, 3 post fractures, and 3 tooth losses, with no statistically difference between groups (p = 0.701), with 77% for SRC and 82% for CRC. CONCLUSION: Fiber post cementation strategies with conventional or self-adhesive resin cement presents similar tooth survival and success rates. TRIAL REGISTRATION: NCT01461239 CLINICAL RELEVANCE: Both adhesive cementation strategies led to high survival and success rates and are indicated for fiber post cementation, even after a long follow-up period (up to 106 months).


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Humanos , Cimentos de Resina/química , Cimentação/métodos , Cimentos Dentários/química , Taxa de Sobrevida , Estudos Prospectivos , Vidro/química , Teste de Materiais , Análise do Estresse Dentário , Dentina
19.
J Shoulder Elbow Surg ; 32(2): 383-391, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36206984

RESUMO

BACKGROUND: There are no generally accepted guidelines for polyethylene (PE) glenoid component cementation techniques. In particular, it is not known whether the backside of a PE glenoid should be fully or partially cemented-or not cemented at all. We hypothesized that cementing techniques would have an impact on cement mantle volume and integrity, as well as biomechanical stability, measured as micromotion under cyclic loading. METHODS: To address our hypothesis, 3 different cementation techniques using a single 2-peg PE glenoid design with polyurethane foam were compared regarding (1) the quality and quantity of the cement mantle and (2) biomechanical stability after cyclic loading in vitro. Eight identically cemented glenoids per group were used. Group A underwent cement application only into the peg holes, group B received additional complete cement mantle application on the backside of the glenoid, and group C received the same treatment as group B but with additional standardized drill holes in the surface of the glenoid bone for extra cement interdigitation. All glenoids underwent cyclic edge loading by 105 cycles according to ASTM F2028-14. Before and after loading, cement mantle evaluation was performed by XtremeCT and biomechanical strength and loosening were evaluated by measuring the relative motion of the implants. RESULTS: The cement mantle at the back of the implant was incomplete in group A as compared with groups B and C, in which the complete PE backside was covered with a homogeneous cement mantle. The cement mantle was thickest in group C, followed by group B (P = .006) and group A (P < .001). We did not detect any breakage of the cement mantle in any of the 3 groups after testing. Primary stability during cyclic loading was similar in all groups after the "running-in" phase (up to 4000 cycles). Gross loosening did not occur in any implant. CONCLUSIONS: Coverage of the PE glenoid with cement was reproducible in the fully cemented groups (ie, groups B and C) as compared with relevant cement defects in group A. The addition of cement to the back of the PE glenoid and additional drill holes in the glenoid surface did not improve primary stability in the tested setting.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Polietileno , Cimentação/métodos , Artroplastia do Ombro/métodos , Tomografia Computadorizada por Raios X , Cimentos Ósseos , Desenho de Prótese , Falha de Prótese
20.
J Arthroplasty ; 38(6): 1052-1056, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36858126

RESUMO

BACKGROUND: This study investigated the presence and progression of radiolucent lines (RLLs) after cemented total knee arthroplasty (TKA) with or without tourniquet use. METHODS: There were 369 consecutive primary cemented TKAs with 5 to 8 years of follow-up. A tourniquet was used during component cementation in patients who underwent surgery from January 3, 2006, to March 31, 2010. No tourniquet was used from August 14, 2009, to October 14, 2014. There were 192 patients in the tourniquet group (TQ) and 177 patients in the no tourniquet group (NQ). Patient demographics, reoperations, and complications were recorded. RLLs were identified on anteroposterior, lateral, and skyline x-rays at 1, 2, and 5 to 8 years postoperatively using the modern knee society radiographic evaluation system. Demographics, reoperations, complications, and RLLs were compared. Age, sex, and body mass index were similar between groups. Mean tourniquet time in TQ was 11 minutes (range, 8 to 25). RESULTS: The presence of RLLs differed between groups, with 65% of TQ knees having RLLs under any part of the prostheses versus 46% of NQ knees (P < .001). The progression of RLL >2 mm occurred in 26.0% of knees in TQ and 16.7% of knees in NQ (P = .028). There were 13 TKAs that underwent subsequent revision surgery. There was no statistically or clinically significant difference in revision rate between groups (7 revisions in TQ, 6 in NQ, P = .66). CONCLUSION: Less RLLs were identified in NQ versus TQ. There were no statistically or clinically significant differences in revision rates between the NQ and TQ groups at 5 to 8 years.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Cimentação , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Radiografia , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA