Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.379
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Neurophysiol ; 132(1): 308-315, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38865216

RESUMO

Neurophysiological recording with a new probe often yields better signal quality than with a used probe. Why does the signal quality degrade after only a few experiments? Here, we considered silicon probes in which the contacts are densely packed, and each contact is coated with a conductive polymer that increases its surface area. We tested 12 Cambridge Neurotech silicon probes during 61 recording sessions from the brain of three marmosets. Out of the box, each probe arrived with an electrodeposited polymer coating on 64 gold contacts and an impedance of around 50 kΩ. With repeated use, the impedance increased and there was a corresponding decrease in the number of well-isolated neurons. Imaging of the probes suggested that the reduction in signal quality was due to a gradual loss of the polymer coating. To rejuvenate the probes, we first stripped the contacts, completely removing their polymer coating, and then recoated them in a solution of 10 mM 3,4-Ethylenedioxythiophene (EDOT) monomer with 11 mM Poly(sodium 4-styrenesulfonate) (PSS) using a current density of about 3 mA/cm2 for 30 s. This recoating process not only returned probe impedance to around 50 kΩ but also yielded significantly improved signal quality during neurophysiological recordings. Thus, insertion into the brain promoted the loss of the polymer that coated the contacts of the silicon probes. This led to degradation of signal quality, but recoating rejuvenated the probes.NEW & NOTEWORTHY With repeated use, a silicon probe's ability to isolate neurons degrades. As a result, the probe is often discarded after only a handful of uses. Here, we demonstrate a major source of this problem and then produce a solution to rejuvenate the probes.


Assuntos
Callithrix , Neurônios , Silício , Animais , Silício/farmacologia , Neurônios/fisiologia , Neurônios/efeitos dos fármacos , Impedância Elétrica , Eletrodos Implantados , Encéfalo/fisiologia , Encéfalo/efeitos dos fármacos , Polímeros/farmacologia , Masculino , Neurofisiologia/instrumentação , Neurofisiologia/métodos , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Microeletrodos
2.
Anal Chem ; 96(31): 12701-12709, 2024 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-39039062

RESUMO

Microelectrodes are useful electrochemical sensors that can provide spatial biological monitoring. Carbon fiber has been by far the most widely used microelectrode; however, a vast number of different materials and modification strategies have been developed to broaden the scope of microelectrodes. Carbon composite electrodes provide a simple approach to making microelectrodes with a wide range of materials, but manufacturing strategies are complex. 3D printing can provide the ability to make microelectrodes with high precision. We used fused filament fabrication to print single strands of carbon black/polylactic acid (CB/PLA) and multiwall carbon nanotube/polylactic acid (MWCNT/PLA), which were then made into microelectrodes. Microelectrodes ranged from 70 µm in diameter to 400 µm in diameter and were assessed using standard redox probes. MWCNT/PLA electrodes exhibited greater sensitivity, a lower limit of detection, and stability for the measurement of serotonin (5-HT). Both CB/PLA and MWCNT/PLA microelectrodes were able to monitor 5-HT overflow from the ex vivo ileum tissue. MWCNT/PLA microelectrodes were utilized to show differences in 5-HT overflow from ex vivo ileum and colon following exposure to odorants present in spices. These findings highlight that any conductive thermoplastic material can be fabricated into a microelectrode. This simple strategy can utilize a wide range of materials to make 3D-printed microelectrodes for a diverse range of applications.


Assuntos
Microeletrodos , Nanotubos de Carbono , Impressão Tridimensional , Nanotubos de Carbono/química , Animais , Serotonina/análise , Poliésteres/química , Fuligem/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos
3.
Anal Chem ; 96(25): 10322-10331, 2024 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-38801718

RESUMO

The chemical information on brain science provided by electrochemical sensors is critical for understanding brain chemistry during physiological and pathological processes. A major challenge is the selectivity of electrochemical sensors in vivo. This work developed a universal covalent grafting strategy of an aptamer on a carbon fiber microelectrode (CFE) for selective determination of dopamine in vivo. The universal strategy was proposed by oxidizing poly(tannic acid) (pTA) to form an oxidized state (pTAox) and then coupling a nucleophilic sulfhydryl molecule of the dopamine-binding mercapto-aptamer with the o-quinone moiety of pTAox based on click chemistry for the interfacial functionalization of the CFE surface. It was found that the universal strategy proposed could efficiently graft the aptamer on a glassy carbon electrode, which was verified by using electroactive 6-(ferrocenyl) hexanethiol as a redox reporter. The amperometric method using a fabricated aptasensor for the determination of dopamine was developed. The linear range of the aptasensor for the determination of dopamine was 0.2-20 µM with a sensitivity of 0.09 nA/µM and a limit of detection of 88 nM (S/N = 3). The developed method has high selectivity originating from the specific recognition of the aptamer in concert with the cation-selective action of pTA and could be easily applicable to probe dopamine dynamics in the brain. Furthermore, complex vesicle fusion modes were first observed at the animal level. This work demonstrated that the covalently grafted immobilization strategy proposed is promising and could be extended to the in vivo analysis of other neurochemicals.


Assuntos
Aptâmeros de Nucleotídeos , Fibra de Carbono , Dopamina , Microeletrodos , Dopamina/análise , Aptâmeros de Nucleotídeos/química , Fibra de Carbono/química , Animais , Técnicas Eletroquímicas/métodos , Carbono/química , Ratos , Técnicas Biossensoriais/métodos , Masculino , Oxirredução
4.
Small ; 20(33): e2311274, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38511575

RESUMO

Preclinical drug screening for cardiac toxicity has traditionally relied on observing changes in cardiomyocytes' electrical activity, primarily through invasive patch clamp techniques or non-invasive microelectrode arrays (MEA). However, relying solely on field potential duration (FPD) measurements for electrophysiological assessment can miss the full spectrum of drug-induced toxicity, as different drugs affect cardiomyocytes through various mechanisms. A more comprehensive approach, combining field potential and contractility measurements, is essential for accurate toxicity profiling, particularly for drugs targeting contractile proteins without affecting electrophysiology. However, previously proposed platform has significant limitations in terms of simultaneous measurement. The novel platform addresses these issues, offering enhanced, non-invasive evaluation of drug-induced cardiotoxicity. It features eight cantilevers with patterned strain sensors and MEA, enabling real-time monitoring of both cardiomyocyte contraction force and field potential. This system can detect minimum cardiac contraction force of ≈2 µN and field potential signals with 50 µm MEA diameter, using the same cardiomyocytes in measurements of two parameters. Testing with six drugs of varied mechanisms of action, the platform successfully identifies these mechanisms and accurately assesses toxicity profiles, including drugs not inhibiting potassium channels. This innovative approach presents a comprehensive, non-invasive method for cardiac function assessment, poised to revolutionize preclinical cardiotoxicity screening.


Assuntos
Cardiotoxicidade , Miócitos Cardíacos , Polímeros , Miócitos Cardíacos/efeitos dos fármacos , Animais , Polímeros/química , Microeletrodos , Avaliação Pré-Clínica de Medicamentos/métodos , Contração Miocárdica/efeitos dos fármacos , Ratos
5.
Analyst ; 149(8): 2351-2362, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38375597

RESUMO

Monitoring the coordinated signaling of dopamine (DA) and serotonin (5-HT) is important for advancing our understanding of the brain. However, the co-detection and robust quantification of these signals at low concentrations is yet to be demonstrated. Here, we present the quantification of DA and 5-HT using nano-graphitic (NG) sensors together with fast-scan cyclic voltammetry (FSCV) employing an engineered N-shape potential waveform. Our method yields 6% error in quantifying DA and 5-HT analytes present in in vitro mixtures at concentrations below 100 nM. This advance is due to the electrochemical properties of NG sensors which, in combination with the engineered FSCV waveform, provided distinguishable cyclic voltammograms (CVs) for DA and 5-HT. We also demonstrate the generalizability of the prediction model across different NG sensors, which arises from the consistent voltammetric fingerprints produced by our NG sensors. Curiously, the proposed engineered waveform also improves the distinguishability of DA and 5-HT CVs obtained from traditional carbon fiber (CF) microelectrodes. Nevertheless, this improved distinguishability of CVs obtained from CF is inferior to that of NG sensors, arising from differences in the electrochemical properties of the sensor materials. Our findings demonstrate the potential of NG sensors and our proposed FSCV waveform for future brain studies.


Assuntos
Dopamina , Grafite , Carbono , Serotonina , Fibra de Carbono , Microeletrodos , Técnicas Eletroquímicas/métodos
6.
Analyst ; 149(2): 457-466, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38087947

RESUMO

Carbon-fiber microelectrodes (CFMEs) are primarily used to detect neurotransmitters in vivo with fast-scan cyclic voltammetry (FSCV) but other carbon nanomaterial electrodes are being developed. CFME sensitivity to dopamine is improved by applying a constant 1.5 V vs. Ag/AgCl for 3 minutes while dipped in 1 M KOH, which etches the surface and adds oxygen functional groups. However, KOH etching of other carbon nanomaterials and applications to other neurochemicals have not been investigated. Here, we explored KOH etching of CFMEs and carbon nanotube yarn microelectrodes (CNTYMEs) to characterize sensitivity to dopamine, epinephrine, norepinephrine, serotonin, and 3,4-dihydroxyphenylacetic acid (DOPAC). With CNTYMEs, the potential was applied in KOH for 1 minute because the electrode surface cracked with the longer time. KOH treatment increased electrode sensitivity to each cationic neurotransmitter roughly 2-fold for CFMEs, and 2- to 4-fold for CNTYMEs. KOH treatment decreased the background current of the CFMEs by etching the surface carbon; however, KOH-treatment increased the CNTYME background current because the potential separates individual nanotubes. For DOPAC, the current increase was smaller at CNTYMEs because it is anionic and was repelled by the negative holding potential and did not access the crevices. XPS and Raman spectroscopy showed that KOH treatment changed the CNTYME surface chemistry by increasing defect sites and adding oxide functional groups. KOH-treated CNTYMEs had less fouling to serotonin than normal CNTYMEs. Therefore, KOH treatment activates both CFMEs and CNTYMEs and could be used in biological measurements to increase the sensitivity and decrease fouling for neurochemical measurements.


Assuntos
Nanoestruturas , Nanotubos de Carbono , Dopamina , Serotonina , Ácido 3,4-Di-Hidroxifenilacético , Microeletrodos , Nanotubos de Carbono/química , Neurotransmissores , Fibra de Carbono
7.
Analyst ; 149(10): 3008-3016, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38606455

RESUMO

Fast-scan cyclic voltammetry (FSCV) is a widely used technique for detecting neurotransmitters. However, electrode fouling can negatively impact its accuracy and sensitivity. Fouling refers to the accumulation of unwanted materials on the electrode surface, which can alter its electrochemical properties and reduce its sensitivity and selectivity. Fouling mechanisms can be broad and may include biofouling, the accumulation of biomolecules on the electrode surface, and chemical fouling, the deposition of unwanted chemical species. Despite individual studies discussing fouling effects on either the working electrode or the reference electrode, no comprehensive study has been conducted to compare the overall fouling effects on both electrodes in the context of FSCV. Here, we examined the effects of biofouling and chemical fouling on the carbon fiber micro-electrode (CFME) as the working electrode and the Ag/AgCl reference electrode with FSCV. Both fouling mechanisms significantly decreased the sensitivity and caused peak voltage shifts in the FSCV signal with the CFME, but not with the Ag/AgCl reference electrode. Interestingly, previous studies have reported peak voltage shifts in FSCV signals due to the fouling of Ag/AgCl electrodes after implantation in the brain. We noticed in a previous study that energy-dispersive spectroscopy (EDS) spectra showed increased sulfide ion concentration after implantation. We hypothesized that sulfide ions may be responsible for the peak voltage shift. To test this hypothesis, we added sulfide ions to the buffer solution, which decreased the open circuit potential of the Ag/AgCl electrode and caused a peak voltage shift in the FSCV voltammograms. Also, EDS analysis showed that sulfide ion concentration increased on the surface of the Ag/AgCl electrodes after 3 weeks of chronic implantation, necessitating consideration of sulfide ions as the fouling agent for the reference electrodes. Overall, our study provides important insights into the mechanisms of electrode fouling and its impact on FSCV measurements. These findings could inform the design of FSCV experiments, with the development of new strategies for improving the accuracy and reliability of FSCV measurements in vivo.


Assuntos
Incrustação Biológica , Técnicas Eletroquímicas , Neurotransmissores , Neurotransmissores/análise , Incrustação Biológica/prevenção & controle , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Animais , Compostos de Prata/química , Fibra de Carbono/química , Microeletrodos , Sulfetos/química , Eletrodos
8.
Analyst ; 149(18): 4643-4652, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39136087

RESUMO

The sensitivity of zinc (Zn(II)) detection using fast-scan cyclic voltammetry (FSCV) with carbon fiber microelectrodes (CFMEs) is low compared to other neurochemicals. We have shown previously that Zn(II) plates to the surface of CFME's and we speculate that it is because of the abundance of oxide functionality on the surface. Plating reduces sensitivity over time and causes significant disruption to detection stability. This limited sensitivity and stability hinders Zn(II) detection, especially in complex matrices like the brain. To address this, we developed plasma-treated gold fiber microelectrodes (AuMEs) which enable sensitive and stable Zn(II) detection with FSCV. Typically, gold fibers are treated using corrosive acids to clean the surface and this step is important for preparing the surface for electrochemistry. Likewise, because FSCV is an adsorption-based technique, it is also important for Zn(II) to adsorb and desorb to prevent irreversible plating. Because of these requirements, careful optimization of the electrode surface was necessary to render the surface for Zn(II) adsorption yet strike a balance between attraction to the surface vs. irreversible interactions. In this study, we employed oxygen plasma treatment to activate the gold fiber surface without inducing significant morphological changes. This treatment effectively removes the organic layer while functionalizing the surface with oxygen, enabling Zn(II) detection that is not possible on untreated gold surfaces. Our results demonstrate significantly improved Zn(II) detection sensitivity and stability on AuME compared to CFME's. Overall, this work provides an advance in our understanding of Zn(II) electrochemistry and a new tool for improved metallotransmitter detection in the brain.


Assuntos
Técnicas Eletroquímicas , Ouro , Microeletrodos , Zinco , Zinco/química , Ouro/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Fibra de Carbono/química , Gases em Plasma/química , Carbono/química , Adsorção , Oxigênio/química
9.
Anal Bioanal Chem ; 416(21): 4807-4818, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38914733

RESUMO

The hormone Neuropeptide Y (NPY) plays critical roles in feeding, satiety, obesity, and weight control. However, its complex peptide structure has hindered the development of fast and biocompatible detection methods. Previous studies utilizing electrochemical techniques with carbon fiber microelectrodes (CFMEs) have targeted the oxidation of amino acid residues like tyrosine to measure peptides. Here, we employ the modified sawhorse waveform (MSW) to enable voltammetric identification of NPY through tyrosine oxidation. Use of MSW improves NPY detection sensitivity and selectivity by reducing interference from catecholamines like dopamine, serotonin, and others compared to the traditional triangle waveform. The technique utilizes a holding potential of -0.2 V and a switching potential of 1.2 V that effectively etches and renews the CFME surface to simultaneously detect NPY and other monoamines with a sensitivity of 5.8 ± 0.94 nA/µM (n = 5). Furthermore, we observed adsorption-controlled, subsecond NPY measurements with CFMEs and MSW. The effective identification of exogenously applied NPY in biological fluids demonstrates the feasibility of this methodology for in vivo and ex vivo studies. These results highlight the potential of MSW voltammetry to enable fast, biocompatible NPY quantification to further elucidate its physiological roles.


Assuntos
Técnicas Eletroquímicas , Neuropeptídeo Y , Neuropeptídeo Y/análise , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Microeletrodos , Humanos , Oxirredução , Fibra de Carbono/química , Tirosina/análise , Tirosina/química , Animais
10.
J Nanobiotechnology ; 22(1): 55, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331774

RESUMO

BACKGROUND: Exosomes are nanoscale extracellular vesicles (30-160 nm) with endosome origin secreted by almost all types of cells, which are considered to be messengers of intercellular communication. Cancerous exosomes serve as a rich source of biomarkers for monitoring changes in cancer-related physiological status, because they carry a large number of biological macromolecules derived from parental tumors. The ultrasensitive quantification of trace amounts of cancerous exosomes is highly valuable for non-invasive early cancer diagnosis, yet it remains challenging. Herein, we developed an aptamer-carrying tetrahedral DNA (Apt-TDNA) microelectrode sensor, assisted by a polydopamine (PDA) coating with semiconducting properties, for the ultrasensitive electrochemical detection of cancer-derived exosomes. RESULTS: The stable rigid structure and orientation of Apt-TDNA ensured efficient capture of suspended exosomes. Without PDA coating signal amplification strategy, the sensor has a linear working range of 102-107 particles mL-1, with LOD of ~ 69 exosomes and ~ 42 exosomes for EIS and DPV, respectively. With PDA coating, the electrochemical signal of the microelectrode is further amplified, achieving single particle level sensitivity (~ 14 exosomes by EIS and ~ 6 exosomes by DPV). CONCLUSIONS: The proposed PDA-assisted Apt-TDNA microelectrode sensor, which integrates efficient exosome capture, sensitive electrochemical signal feedback with PDA coating signal amplification, provides a new avenue for the development of simple and sensitive electrochemical sensing techniques in non-invasive cancer diagnosis and monitoring treatment response.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Exossomos , Indóis , Neoplasias , Polímeros , Humanos , Microeletrodos , Exossomos/química , DNA/análise , Neoplasias/diagnóstico , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA