Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.889
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(10): e2306508, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37919860

RESUMO

The design and fabrication of NO-evolving core-shell nanoparticles (denoted as NC@Fe), comprised of BNN6-laden COF@Fe3 O4 nanoparticles, are reported. This innovation extends to the modification of 3D printed polyetheretherketone scaffolds with NC@Fe, establishing a pioneering approach to multi-modal bone therapy tailored to address complications such as device-associated infections and osteomyelitis. This work stands out prominently from previous research, particularly those relying on the use of antibiotics, by introducing a bone implant capable of simultaneous NO gas therapy and photothermal therapy (PPT). Under NIR laser irradiation, the Fe3 O4 NP core (photothermal conversion agent) within NC@Fe absorbs photoenergy and initiates electron transfer to the loaded NO donor (BNN6), resulting in controlled NO release. The additional heat generated through photothermal conversion further propels the NC@Fe nanoparticles, amplifying the therapeutic reach. The combined effect of NO release and PPT enhances the efficacy in eradicating bacteria over a more extensive area around the implant, presenting a distinctive solution to conventional challenges. Thorough in vitro and in vivo investigations validate the robust potential of the scaffold in infection control, osteogenesis, and angiogenesis, emphasizing the timeliness of this unique solution in managing complicated bone related infectious diseases.


Assuntos
Estruturas Metalorgânicas , Polímeros , Benzofenonas , Polietilenoglicóis , Cetonas
2.
Langmuir ; 40(20): 10648-10662, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38712915

RESUMO

This study presents new insights into the potential role of polyelectrolyte interfaces in regulating low friction and interstitial fluid pressurization of cartilage. Polymer brushes composed of hydrophilic 3-sulfopropyl methacrylate potassium salt (SPMK) tethered to a PEEK substrate (SPMK-g-PEEK) are a compelling biomimetic solution for interfacing with cartilage, inspired by the natural lubricating biopolyelectrolyte constituents of synovial fluid. These SPMK-g-PEEK surfaces exhibit a hydrated compliant layer approximately 5 µm thick, demonstrating the ability to maintain low friction coefficients (µ ∼ 0.01) across a wide speed range (0.1-200 mm/s) under physiological loads (0.75-1.2 MPa). A novel polyelectrolyte-enhanced tribological rehydration mechanism is elucidated, capable of recovering up to ∼12% cartilage strain and subsequently facilitating cartilage interstitial fluid recovery, under loads ranging from 0.25 to 2.21 MPa. This is attributed to the combined effects of fluid confinement within the contact gap and the enhanced elastohydrodynamic behavior of polymer brushes. Contrary to conventional theories that emphasize interstitial fluid pressurization in regulating cartilage lubrication, this work demonstrates that SPMK-g-PEEK's frictional behavior with cartilage is independent of these factors and provides unabating aqueous lubrication. Polyelectrolyte-enhanced tribological rehydration can occur within a static contact area and operates independently of known mechanisms of cartilage interstitial fluid recovery established for converging or migrating cartilage contacts. These findings challenge existing paradigms, proposing a novel polyelectrolyte-cartilage tribological mechanism not exclusively reliant on interstitial fluid pressurization or cartilage contact geometry. The implications of this research extend to a broader understanding of synovial joint lubrication, offering insights into the development of joint replacement materials that more accurately replicate the natural functionality of cartilage.


Assuntos
Lubrificação , Polímeros , Polímeros/química , Animais , Polieletrólitos/química , Polietilenoglicóis/química , Cartilagem/química , Cartilagem/efeitos dos fármacos , Propriedades de Superfície , Benzofenonas/química , Cartilagem Articular/química , Cartilagem Articular/fisiologia , Cetonas/química
3.
Biomacromolecules ; 25(4): 2261-2276, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38490188

RESUMO

Polysaccharides are biodegradable, abundant, sustainable, and often benign natural polymers. The achievement of selective modification of polysaccharides is important for targeting specific properties and structures and will benefit future development of highly functional, sustainable materials. The synthesis of polysaccharides containing aldehyde or ketone moieties is a promising tool for achieving this goal because of the rich chemistry of aldehyde or ketone groups, including Schiff base formation, nucleophilic addition, and reductive amination. The obtained polysaccharide aldehydes or ketones themselves have rich potential for making useful materials, such as self-healing hydrogels, polysaccharide-protein therapeutic conjugates, or drug delivery vehicles. Herein, we review recent advances in synthesizing polysaccharides containing aldehyde or ketone moieties and briefly introduce their reactivity and corresponding applications.


Assuntos
Aldeídos , Cetonas , Aldeídos/química , Cetonas/química , Polissacarídeos/química , Sistemas de Liberação de Medicamentos , Polímeros/química , Hidrogéis/química
4.
Eur Spine J ; 33(1): 332-338, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37737497

RESUMO

BACKGROUND: A comparison of fusion rates and clinical outcomes of instrumented transforaminal interbody fusion (TLIF) between polyetheretherketone (PEEK) and titanium-coated PEEK (Ti-PEEK) cages is not well documented. METHODS: A single-centre, prospective, randomised study included patients who underwent one-level TLIF between L3-S1 segments. Patients were randomised into one of two groups: TLIF surgery with the PEEK cage and TLIF surgery with the Ti-PEEK cage. Clinical results were measured. All patients were assessed by repeated X-rays and 3D CT scans. Cage integration was assessed using a modified Bridwell classification. The impact of obesity and smoking on fusion quality was also analysed. Patients in both groups were followed up for 2 years. RESULTS: Altogether 87 patients were included in the study: of these 87 patients, 81 (93.1%) completed the 2-year follow-up. A significant improvement in clinical outcome was found in the two measurements scales in both groups (RM: p = 0.257, VAS: p = 0.229). There was an increase in CobbS and CobbL angle in both groups (p = 0.172 for CobbS and p = 0.403for CobbL). Bony fusion was achieved in 37 of 40 (92.5%) patients in the TiPEEK group and 35 of 41 (85.4%) in the PEEK group (p = 0.157). Cage subsided in 2 of 40 patients (5%) in the TiPEEK group and 11 of 41 (26.8%) in the PEEK group (p = 0.007). Body mass index > 30 and smoking were not predictive factors of bony fusion achievement. CONCLUSION: There is no significant advantage of TiPEEK cages over PEEK cages in clinical outcome and fusion rate 2 years after surgery.


Assuntos
Benzofenonas , Polímeros , Fusão Vertebral , Titânio , Humanos , Vértebras Lombares/cirurgia , Estudos Prospectivos , Fusão Vertebral/métodos , Polietilenoglicóis , Cetonas , Resultado do Tratamento
5.
BMC Musculoskelet Disord ; 25(1): 488, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909212

RESUMO

PURPOSE: To analyze the characteristics of PEEK rods retrieved in vivo, specifically their wear and deformation, biodegradability, histocompatibility, and mechanical properties. METHOD: Six PEEK rods were retrieved from revision surgeries along with periprosthetic tissue. The retrieved PEEK rods were evaluated for surface damage and internal changes using Micro-CT, while light and electron microscopy were utilized to determine any histological changes in periprosthetic tissues. Patient history was gathered from medical records. Two intact and retrieved PEEK rods were used for fatigue testing analysis by sinusoidal load to the spinal construct. RESULTS: All implants showed evidence of plastic deformation around the screw-rod interface, while the inner structure of PEEK rods appeared unchanged with no visible voids or cracks. Examining images captured through light and electron microscopy indicated that phagocytosis of macrophages around PEEK rods was less severe in comparison to the screw-rod interface. The results of an energy spectrum analysis suggested that the distribution of tissue elements around PEEK rods did not differ significantly from normal tissue. During fatigue testing, it was found that the retrieved PEEK rods cracked after 1.36 million tests, whereas the intact PEEK rods completed 5 million fatigue tests without any failure. CONCLUSION: PEEK rods demonstrate satisfactory biocompatibility, corrosion resistance, chemical stability, and mechanical properties. Nevertheless, it is observed that the indentation at the junction between the nut and the rod exhibits relatively weak strength, making it susceptible to breakage. As a precautionary measure, it is recommended to secure the nut with a counter wrench, applying the preset torque to prevent overtightening.


Assuntos
Benzofenonas , Cetonas , Parafusos Pediculares , Polímeros , Humanos , Cetonas/química , Feminino , Masculino , Polietilenoglicóis/química , Pessoa de Meia-Idade , Remoção de Dispositivo , Teste de Materiais , Idoso , Materiais Biocompatíveis , Falha de Prótese , Reoperação
6.
Arthroscopy ; 40(2): 201-203, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38296430

RESUMO

Anterior cruciate ligament reconstruction (ACLR) is among the most common procedures performed by orthopaedic sports medicine surgeons and has inherent challenges due to the complex anatomy and biomechanical properties required to reproduce the function and stability of the native ACL. Awareness of the anatomic and biomechanical factors, including graft selection and tunnel placement, along with graft tensioning and fixation techniques, is vital in achieving a successful clinical outcome. Common techniques for ACLR graft fixation include intratunnel fixation with interference screws, suspensory fixation, or hybrid fixation strategies, along with several supplemental fixation techniques. Interference screw fixation may decrease graft-tunnel motion, tunnel widening, and graft creep and may be performed with metallic, PEEK (polyether ether ketone), or bioabsorbable screws. Suspensory fixation techniques primarily include suture-buttons, anchors, staples, and screws/washers. Suspensory fixation allows adequate biomechanical strength, although some techniques have been linked to increased graft-tunnel motion and potential tunnel widening. Supplemental fixation techniques may be performed in the setting of concerns for adequacy of primary fixation and includes the use of suture anchors, staples, and screw/washer devices. Regardless of the implant chosen for fixation, secure fixation is paramount to avoid displacement of the graft and allow for integration into the bone tunnel and facilitates early postoperative rehabilitation. It is important for orthopaedic sports medicine surgeons performing primary and revision ACLR to be familiar with multiple fixation techniques.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Benzofenonas , Humanos , Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Polietilenoglicóis , Polímeros , Cetonas , Lesões do Ligamento Cruzado Anterior/cirurgia , Tíbia/cirurgia , Fenômenos Biomecânicos
7.
BMC Surg ; 24(1): 169, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811965

RESUMO

BACKGROUND: Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS: An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS: With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS: Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.


Assuntos
Ligas , Benzofenonas , Análise de Elementos Finitos , Cetonas , Vértebras Lombares , Polietilenoglicóis , Polímeros , Fusão Vertebral , Titânio , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular , Materiais Biocompatíveis
8.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
9.
J Craniofac Surg ; 35(5): 1517-1522, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38814081

RESUMO

INTRODUCTION AND AIM: Polyetheretherketone (PEEK) and titanium (Ti) cranioplasty implants ideal outcomes are good esthetics, long-term stability, and protection of the fragile brain tissue. However, it is unclear whether PEEK implants can offer an equal alternative to Ti implants. This work aimed to critically review papers and case series published on both Ti and PEEK Cranioplasty regarding complications, clinical outcomes, ease of use, esthetics, manufacture and availability, cost and time-saving factors, postoperative quality of life (QOL), as well as their suitability for the fronto-orbito region reconstruction. METHODS: PubMed database was sourced for published literature in the period 2007 to the end of 2023; a further manual search for articles was carried out on the reference lists of each paper. RESULTS: A total of 48980 papers were found during the initial search, but only 33 articles met the inclusion criteria. A total of 6023 cranial implants, with 3879 being Ti and 1205 PEEK. Titanium was the material of choice in over 64.4% of cases; however, Ti has been in application for many years compared to PEEK. Out of the 33 papers, there was 27 retrospective cohort/analysis/case series and reviews: 1 meta-analysis, 2 systematic reviews and 3 randomized control trials. Four articles commented on the QOL, 15 on esthetics, 7 discussed cost and time-saving without measurable variables, and 7 articles looked explicitly at the complex fronto-orbito region, of which 49% were primary 1-stage surgical reconstructions, 54% were reconstructed with PEEK and 7% Ti (CAD/CAM). CONCLUSION: There is no absolute consensus for the preference of either material, however, in the fronto-orbito region, PEEK is the material of choice for ease of use, esthetics, and time-saving. However, there are no long-term studies on PEEK cranioplasty, and fewer in comparison with Ti implants. Further research is required in this field. No reliable or measurable data was found to determine the QOL, esthetics, cost, or time-saving elements.


Assuntos
Benzofenonas , Materiais Biocompatíveis , Cetonas , Polietilenoglicóis , Polímeros , Qualidade de Vida , Crânio , Titânio , Humanos , Crânio/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Próteses e Implantes , Estética
10.
Aesthetic Plast Surg ; 48(10): 1889-1898, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38409347

RESUMO

BACKGROUND: Forehead augmentation have become popular aesthetic procedures among Asians in recent years. However, the use of polyetheretherketone (PEEK) patient-specific implant (PSI) in the facial contouring surgery for aesthetic considerations is not well documented in the existing studies. The purpose of this study was to develop a novel method for forehead augmentation and assess the clinical outcomes and complications in patients who underwent forehead augmentation with PEEK PSI assisted by endoscopy. METHODS: The PEEK PSIs were fabricated using the virtual surgical planning (VSP) and the computer-aided manufacturing (CAM) for each patient, preoperatively. The implant pockets were dissected in the subperiosteal plane, and PEEK PSIs were placed in their designed position and fixed assisting by endoscopy via small incision within the hairline. All patients were asked to complete the FACE-Q questionnaire before and 6 months after the operation. Pre- and postoperative demographics, photographs, and other clinical data of patients were collected and analyzed. RESULTS: 11 patients underwent forehead augmentation were enrolled in this study. All procedures were completed successfully with the help of endoscope. The average patient age was 30.63 ± 2.54 years. The mean thickness and size of PEEK PSI were 4.44 ± 1.77 mm and 38.43 ± 22.66 cm2, respectively. The mean operative time was 83.00 ± 29.44 min, and the mean postoperative follow-up period was 11.00 ± 6.50 months. No implant exposure, extrusion or removal were reported. The FACE-Q scores of patients in satisfaction with the forehead increased from 47.64 ± 7.15 to 78.81 ± 6.35. CONCLUSIONS: PEEK PSIs can be prefabricated to achieve accurate remodeling of the frontal contour with good esthetic outcomes. The endoscope provides direct and magnified vision, which allow easy access to the supraorbital rim and lateral edge of the eyebrow arch and confirming the position of the implants without damaging nerves and vessels. Endoscopic-assisted forehead augmentation with PEEK PSI is safe and effective. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Benzofenonas , Endoscopia , Estética , Testa , Cetonas , Polietilenoglicóis , Polímeros , Humanos , Adulto , Feminino , Testa/cirurgia , Endoscopia/métodos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Materiais Biocompatíveis , Estudos de Coortes , Próteses e Implantes
11.
Int J Mol Sci ; 25(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38256172

RESUMO

In this research, two polymers of P1 and P2 based on monomers consisting of thiophene, 3,4-Ethylenedioxythiophene (EDOT) and diketopyrrolopyrrole (DPP) are designed and obtained via Stille coupling polycondensation. The material shows excellent coplanarity and structural regularity due to the fine planarity of DPP itself and the weak non-covalent bonding interactions existing between the three units. Two different lengths of non-conjugated side chains are introduced and this has an effect on the intermolecular chain stacking, causing the film absorption to display different characteristic properties. On the other hand, the difference in the side chains does not have a significant effect on the thermal stability and the energy levels of the frontier orbitals of the materials, which is related to the fact that the materials both feature extremely high conjugation lengths and specific molecular compositions. Microscopic investigations targeting the side chains provide a contribution to the further design of organic semiconductor materials that meet device requirements. Tests based on organic transistors show a slight difference in conductivity between the two polymers, with P2 having better hole mobility than P1. This study highlights the importance of the impact of side chains on device performance, especially in the field of organic electronics.


Assuntos
Eletrônica , Cetonas , Polímeros , Pirróis , Tiofenos , Condutividade Elétrica
12.
J Prosthet Dent ; 131(2): 273-280, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37620182

RESUMO

STATEMENT OF PROBLEM: Although polyetheretherketone (PEEK) and zirconia (Zir) have been used as implant-supported prosthesis (ISP) frameworks, the long-term effects of thermomechanical aging on the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with titanium (Ti) bases for patients with a partially edentulous arch are not clear. PURPOSE: The purpose of this in vitro study was to determine the marginal fit and fracture resistance of PEEK and Zir ISP frameworks with Ti bases and Ti ISP frameworks for partially edentulous arches after aging. MATERIAL AND METHODS: A total of 30 ISP epoxy resin casts were obtained from a typodont with 1 straight implant (Nobel Biocare) in the mandibular right canine region and 1 implant with a 30-degree distal tilt in the mandibular right first molar region. All frameworks (n=10) were fabricated on their own epoxy resin cast with multiunit abutment replicas by using a computer-aided design and computer-aided manufacturing system (exocad-Yenadent). The PEEK and Zir frameworks were fabricated with Ti-bases. Primer (MKZ) and resin cement (DTK adhesive) were used to cement the frameworks to the Ti-bases under a static load of 10 N. After thermomechanical aging (1.2×106 cycles, 120 N, 5 °C-55 °C), marginal gaps between the Ti-bases and cemented frameworks and vertical and passive fits between the Ti-bases and framework and multi-unit abutments were measured by using a stereomicroscope (Euromex) at ×100 magnification. Fracture resistances and types were then determined by using a universal test machine and a stereomicroscope at ×40 magnification. Data were analyzed by using 1-way analysis of variance (ANOVA) and the Tukey HSD and Fisher-Freeman-Halton tests (α=.05). RESULTS: The marginal gaps of the PEEK and Zir frameworks were respectively 83.5 ±27.1 and 81.8 ±17.8 µm. PEEK (23.7 ±4.6) and Zir (32.9 ±8.7) had a better vertical fit (µm) than Ti (52.5 ±10.6) (P<.001). Zir (49.3 ±16.2) (P<.001) and PEEK (70.9 ±19.6) (P>.05) frameworks had better passive fit (µm) than Ti (91.3 ±24.2). Ti had the highest mean fracture resistance (N) (14800.2 ±3442.3) followed by Zir (7318.7 ±1385.1) and PEEK (3448.9 ±486.6) (P<.001). Fracture types were different in different groups (P<.001). CONCLUSIONS: The PEEK and Zir frameworks with Ti bases had better vertical and passive fit than the Ti frameworks. All ISP frameworks represented mean marginal fit below 92 µm and withstood physiologic occlusal forces after thermomechanical aging.


Assuntos
Benzofenonas , Implantes Dentários , Boca Edêntula , Polímeros , Humanos , Titânio , Resinas Epóxi , Polietilenoglicóis , Zircônio , Cetonas , Desenho Assistido por Computador , Teste de Materiais
13.
J Prosthet Dent ; 131(2): 291.e1-291.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38057199

RESUMO

STATEMENT OF PROBLEM: The retentive force and deformation of milled polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) removable partial denture (RPD) frameworks are not well understood. PURPOSE: The purpose of this in vitro study was to assess the retentive force and deformation of PEEK and PEKK Akers clasps with different designs and undercut depths. MATERIAL AND METHODS: A master model containing the first and second molar abutments was used to design Akers clasps of different cross-sectional dimensions, undercut depths (0.5 and 0.75 mm), and materials. The components of the removable partial denture framework also included an occlusal rest and were manufactured using a milling machine (n=5). The fatigue resistance of the Akers clasps was measured before and after deformation regarding the retentive forces. RESULTS: The PEEK2-U50 clasp had the largest retentive force with no significant difference among all groups before and after the insertion and removal cycle. In addition, the increased cross-sectional dimensions of the design resulted in significant differences in retentive forces between the PEEK1 and PEEK2 groups and between the PEEK and PEKK materials. CONCLUSIONS: Increasing the clasp's cross-sectional dimensions significantly impacted retentive forces, especially between different PEEK groups and between PEEK and PEKK materials.


Assuntos
Benzofenonas , Ligas de Cromo , Prótese Parcial Removível , Polímeros , Estudos Transversais , Retenção de Dentadura , Polietilenoglicóis , Cetonas , Grampos Dentários
14.
J Prosthet Dent ; 131(6): 1235.e1-1235.e8, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38594086

RESUMO

STATEMENT OF PROBLEM: Additive (AM) and subtractive (SM) manufacturing have become popular for fabricating occlusal devices with materials of different chemical compositions. However, knowledge on the effect of material and antagonist type on the wear characteristics of occlusal devices fabricated by using different methods is limited. PURPOSE: The purpose of this in vitro study was to evaluate the effect of material and antagonist type on the wear of occlusal devices fabricated by using conventional manufacturing, AM, and SM. MATERIAL AND METHODS: Two-hundred and forty Ø10×2-mm disk-shaped specimens were fabricated by using heat-polymerized polymethylmethacrylate (control, CM), AM clear device resin fabricated in 3 different orientations (horizontal [AMH], diagonal [AMD], and vertical [AMV]), SM polymethylmethacrylate (SMP), and SM ceramic-reinforced polyetheretherketone (SMB) (n=40). Specimens were then divided into 4 groups based on the antagonists: steatite ceramic (SC); multilayered zirconia (ZR); lithium disilicate (EX); and zirconia-reinforced lithium silicate (ZLS) used for thermomechanical aging (n=10). After aging, the volume loss (mm3) and maximum wear depth (µm) were digitally evaluated. Data were analyzed with 2-way analysis of variance and Tukey honestly significant difference tests (α=.05). RESULTS: The interaction between the device material and the antagonist affected volume loss and maximum depth of wear (P<.001). AMH had volume loss and depth of wear that was either similar to or higher than those of other materials (P≤.044). When SC was used, CM had higher volume loss and depth of wear than AMV, and, when EX was used, AMD had higher volume loss and depth of wear than SMP (P≤.013). SC and ZR led to higher volume loss of CM and AMH than EX and led to the highest depth of wear for these materials, while ZR also led to the highest volume loss and depth of wear of AMD and AMV (P≤.019). EX led to the lowest volume loss and depth of wear of AMV and SMP and to the lowest depth of wear of AMH (P≤.021). Regardless of the antagonist, SMB had the lowest volume loss and depth of wear (P≤.005). CONCLUSIONS: AMH mostly had higher volume loss and depth of wear, while SMB had the lowest volume loss, and its depth of wear was not affected by the tested antagonists. ZR mostly led to higher volume loss and maximum depth of wear, while EX mostly led to lower volume loss and maximum depth of wear of the tested occlusal device materials.


Assuntos
Materiais Dentários , Teste de Materiais , Polimetil Metacrilato , Zircônio , Materiais Dentários/química , Polimetil Metacrilato/química , Zircônio/química , Cerâmica/química , Humanos , Técnicas In Vitro , Placas Oclusais , Desgaste de Restauração Dentária , Planejamento de Prótese Dentária , Benzofenonas , Porcelana Dentária/química , Polímeros/química , Propriedades de Superfície , Polietilenoglicóis/química , Cetonas/química
15.
Arch Orthop Trauma Surg ; 144(5): 2067-2076, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38642161

RESUMO

BACKGROUND: Polyaryl-ether-ether-ketone (PEEK) has gained popularity as a substrate for orthopaedic hardware due to its desirable properties such as heat and deformation resistance, low weight, and ease of manufacturing. However, we observed a relatively high failure rate of PEEK-based hinges in a distal femur reconstruction system. In this study, we aimed to evaluate the proportion of patients who experienced implant failure, analyse the mechanism of failure, and document the associated clinical findings. METHODS: We conducted a retrospective cohort study, reviewing the medical charts of 56 patients who underwent distal femur resection and reconstruction with a PEEK Optima hinge-based prosthesis between 2004 and 2018. Concurrently, we performed a clinical and biomechanical failure analysis. RESULTS: PEEK component failure occurred in 21 out of 56 patients (37.5%), with a mean time to failure of 63.2 months (range: 13-144 months, SD: 37.9). The survival distributions of PEEK hinges for males and females were significantly different (chi-square test, p-value = 0.005). Patient weight was also significantly associated with the hazard of failure (Wald's test statistic, p-value = 0.031). DISCUSSION: Our findings suggest that PEEK hinge failure in a distal femur reconstruction system is correlated with patient weight and male gender. Retrieval analysis revealed that failure was related to fretting and microscopic fractures due to cyclic loading, leading to instability and mechanical failure of the PEEK component in full extension. Further assessment of PEEK-based weight bearing articulating components against metal is warranted.


Assuntos
Benzofenonas , Fêmur , Cetonas , Polietilenoglicóis , Polímeros , Desenho de Prótese , Falha de Prótese , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Fêmur/cirurgia , Adulto , Idoso de 80 Anos ou mais
16.
BMC Oral Health ; 24(1): 444, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609958

RESUMO

BACKGROUND: This study evaluated the shear bond strength (SBS) of two different polyetheretherketone (PEEK) and CAD-CAM materials after aging. METHODS: A total of 42 frameworks were designed and milled from 2 different PEEK discs (Copra Peek, P and BioHPP, B). P and B frameworks were divided into 3 subgroups (n = 7). 14 slices were prepared each from feldspathic ceramic (Vitablocs Mark II, VM), hybrid nanoceramic (Cerasmart, CS), and polymer-infiltrated ceramic (Vita Enamic, VE) blocks. After surface preparations, the slices were cemented to P and B surfaces. The samples were subjected to thermal aging (5000 cycles). SBS of all the samples was measured. Fractured surfaces were examined by SEM/EDX analysis. The Shapiro-Wilk, Two-way Robust ANOVA and Bonferroni correction tests were used to analyze the data (a = .05). RESULTS: Frameworks, ceramics, and frameworks x ceramics had significant differences (p < 0.05). The highest SBS value was seen in B-VM (p < 0.05). VM offered the highest SBS with both P and B. The differences between P-VM, P-CS, P-VE and B-CS and B-VE were insignificant (p > 0.05). According to EDX analysis, ytterbium and fluorine was seen in B content, unlike P. While VM and CS contained fluorine, barium, and aluminum; sodium and aluminum were observed in the VE structure. CONCLUSION: Bonding of P and B with VM offers higher SBS. VM, CS and VE did not make any difference in SBS for P, however VM showed a significant difference for B.


Assuntos
Alumínio , Benzofenonas , Flúor , Polímeros , Humanos , Polietilenoglicóis , Desenho Assistido por Computador , Cetonas
17.
BMC Oral Health ; 24(1): 760, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965507

RESUMO

BACKGROUND: Preservation of the remaining structures while maintaining an esthetic appearance is a major objective in removable partial prosthodontics. So, the aim of the current study was to compare the stresses induced on the supporting structures by two digitally produced esthetic core materials; Zirconia and Polyetheretherketone when used as an extracoronal attachment in distal extension removable partial dentures using strain gauge analysis. METHODS: A mandibular Kennedy class II stone cast with the necessary abutments' preparations was scanned. The mandibular left canine and first premolar teeth were virtually removed. An acrylic mandibular left canine and first premolar teeth were prepared with heavy chamfer finish line and scanned. Virtual superimposition of the acrylic teeth in their corresponding positions was done. Two strain gauge slots were designed: distal to the terminal abutment and in the residual ridge. Two models and two sets of scanned teeth were digitally printed. The printed teeth were then placed in their corresponding sockets in each model and scanned. The attachment design was selected from the software library and milled out of Zirconia in the model ZR and Polyetheretherketone in the model PE. Five removable partial dentures were constructed for each model. The strain gauges were installed in their grooves. A Universal testing machine was used for unilateral load application of 100 N (N). For each removable partial denture, five measurements were made. The data followed normal distribution and were statistically analyzed by using unpaired t test. P value < 0.05 was considered to be statistically significant. RESULTS: During unilateral loading unpaired t test showed statistically significant difference (p = 0.0001) in the microstrain values recorded distal to the abutment between the models ZR (-1001.6 µÎµ ± 24.56) and PE (-682.6 µÎµ ± 22.18). However, non statistically significant difference (p = 0.3122) was observed in the residual ridge between them; ZR (16.2 µÎµ ± 4.53) and PE (15 µÎµ ± 3.74). CONCLUSIONS: In removable partial dentures, Polyetheretherketone extracoronal attachment induces less stress on the supporting abutments compared to the zirconia one with no difference in the stresses induced by them on the residual ridge.


Assuntos
Benzofenonas , Planejamento de Dentadura , Prótese Parcial Removível , Cetonas , Polímeros , Zircônio , Cetonas/química , Humanos , Zircônio/química , Polietilenoglicóis , Análise do Estresse Dentário , Materiais Dentários/química , Desenho Assistido por Computador , Dente Suporte , Estresse Mecânico , Estética Dentária , Teste de Materiais
18.
BMC Oral Health ; 24(1): 248, 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38368396

RESUMO

INTRODUCTION: The prevalence of adults with partially dental arches is expected to be more than imagined and patients requiring replacement of missing teeth are slowly increasing in number too. Removable partial dentures are known to provide for substantial replacement for the missing teeth with also added advantages when compared to fixed or implant prosthesis, mainly in elderly patients. Denture base material performance and durability are greatly influenced by wettability and water contact angle. In the case of dentures; adequate moisture distribution is necessary to ensure excellent wettability which has an influence on comfort and oral health. The purpose of conducting this study was to find out whether the advancements made using PEEK (Polyether ether ketone) would prove to be more beneficial than the current upgrades in the current material spectrum. MATERIALS AND METHODS: This study was performed under in vitro conditions. All the fabrication and processing was done only by one operator. The materials used were divided into three groups each comprising 20 samples. Group A was modified polymethylmethacrylate (Bredent Polyan), Group B was polyoxymethylene acetal resin (Biodentaplast) and Group C was PEEK. An Ossila Goniometer was used to measure the contact angle. The three types of liquids used for the testing included distilled water, natural saliva and mouth wetting solution (Wet Mouth Liquid, ICPA India). Human saliva was collected from an individual with no medical conditions and normal salivary secretion. RESULTS: The data was analyzed using One-way ANOVA test and a pairwise comparison using the Post Hoc Tukey's Honest Significant Difference. Table 1 consists of the mean water contact angles of the denture base materials and mean contact angles of various denture base materials. In saliva, mouth wetting solution and distilled water, the highest mean and least mean contact angle was seen in Polyan and Biodentaplast respectively. A signicant difference was seen between PEEK and Polyan and Biodentaplast and Polyan on further comparison. CONCLUSION: From the resources and the materials at our disposal, it could be concluded that Polyan, Biodentaplast and PEEK and could be used as viable options in cast partial denture framework.


Assuntos
Resinas Acrílicas , Benzofenonas , Polímeros , Polimetil Metacrilato , Bases de Dentadura , Prótese Parcial , Cetonas , Teste de Materiais , Metacrilatos , Polietilenoglicóis , Água , Molhabilidade
19.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702708

RESUMO

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Estética Dentária , Técnica para Retentor Intrarradicular , Humanos , Cerâmica , Análise do Estresse Dentário , Benzofenonas , Incisivo/lesões , Materiais Dentários/química , Polietilenoglicóis , Cetonas/química , Polímeros , Vidro , Teste de Materiais , Planejamento de Prótese Dentária
20.
BMC Oral Health ; 24(1): 765, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970080

RESUMO

OBJECTIVE: To determine the effects of conventional cigarette smoking (CS) and recent heated tobacco products (HTPs) on the surface roughness and color stability of different indirect restorative materials. MATERIALS AND METHODS: One hundred disc-shaped samples were constructed of three different restorative CAD/CAM materials: lithium disilicate glass-ceramic (IPS e.max CAD; Ivoclar Vivadent, Liechtenstein), zirconia (BruxZir® Zirconia, Glidewell, USA) and polyetheretherketone (BioHPP® bredent GmbH, Germany). Of the IPS e.max CAD and the Bruxzir samples, 20 samples were glazed, and 20 samples were polished, while the BioHPP samples were all polished according to the manufacturer's instructions. Fifty samples were subjected to conventional cigarette smoking (LM, Philip Morris International Inc., Egypt) (Groups: IPS e.max CAD_Glazed exposed to CS (LD_G_Cig), IPS e.max CAD_Polished exposed to CS (LD_P_Cig), Bruxzir_Glazed exposed to CS (Zr_G_Cig), Bruxzir _Polished exposed to CS (Zr_P_Cig) and BioHPP exposed to CS (PEEK_Cig) and fifty samples were exposed to heated tobacco product smoking (Heets, Russet selection, Philip Morris International Inc., Italy) (Groups: IPS e.max CAD_Glazed exposed to HTP (LD_G_HTP), IPS e.max CAD_Polished exposed to HTP (LD_P_HTP), Bruxzir_Glazed exposed to HTP (Zr_G_HTP), Bruxzir CAD_Polished exposed to HTP (Zr_P_HTP) and BioHPP exposed to HTP (PEEK_HTP).. Six hundred cigarettes/heets representing 30 days of medium smoking behavior (20 cigarettes/day) were used. Before and after exposure to smoke, the surface roughness of all the samples was measured using JITAI8101 surface roughness tester (Beijing Jitai Tech Detection Device Co., Ltd, China, and the color parameters were assessed using VITA Easyshade Advance 4.01 (VITA shade, VITA made, VITA). The data were analyzed using One-way ANOVA, paired sample t-test and independent sample t-test. The significance level was set at α < 0.05. The surface topography was evaluated by scanning electron microscopy (SEM) and analyzed using energy-dispersive X-ray (EDX) spectroscopy to determine changes in the surface chemical composition. RESULTS: Both types of smoking caused significant increases in the surface roughness of all the samples. There was a significant difference in color change between CS and HTP for all materials with different surface finish (P < 0.01) and zirconia had the greatest effect on color change (P < 0.001). In contrast, polyetheretherketone (PEEK) "BioHPP" had the least effect (P < 0.001). CONCLUSION: Exposure to different types of smoking induce changes in the surface topography and color of different esthetic restorative materials. Compared with HTP, conventional cigarette smoke has a greater effect on the surface roughness and color stability of esthetic restorative materials. The glazed surfaces showed less change in surface topography than did the polished surfaces. Zirconia showed better color stability when compared to polyetheretherketone (PEEK).


Assuntos
Cerâmica , Fumar Cigarros , Desenho Assistido por Computador , Materiais Dentários , Porcelana Dentária , Cetonas , Polietilenoglicóis , Polímeros , Propriedades de Superfície , Produtos do Tabaco , Zircônio , Polietilenoglicóis/química , Zircônio/química , Produtos do Tabaco/efeitos adversos , Cerâmica/química , Cetonas/química , Porcelana Dentária/química , Fumar Cigarros/efeitos adversos , Materiais Dentários/química , Benzofenonas , Teste de Materiais , Temperatura Alta , Humanos , Cor , Restauração Dentária Permanente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA