[Medpor plus titanic mesh implant in the repair of orbital blowout fractures].
Zhonghua Yi Xue Za Zhi
; 91(17): 1181-3, 2011 May 10.
Article
en Zh
| MEDLINE
| ID: mdl-21756771
OBJECTIVE: To study the efficacy of porous polyethylene (Medpor) plus titanic mesh sheets in the repair of orbital blowout fractures. METHODS: A total of 20 patients underwent open surgical reduction with the combined usage of Medpor and titanic mesh. And they were followed up for average period of 14.5 months (range: 9 - 18). RESULTS: There is no infection or extrusion of medpor and titanic mesh in follow-up periods. There was no instance of decreased visual acuity at post-operation. And all cases of enophthalmos were corrected. The post-operative protrusion degree of both eyes was almost identical at less than 2 mm. The movement of eye balls was satisfactory in all directions. Diplopia disappeared in 18 cases with a cure rate of 90%, 1 case improved and 1 case persisted. CONCLUSION: Medpor plus titanic mesh implant is a safe and effective treatment in the repair of orbital blow out fractures.