Your browser doesn't support javascript.
loading
Restoration of endodontically treated teeth with major hard tissue loss - influence of post surface design on pull-out bond strength of fiber-reinforced composite posts.
Koch, Andreas Thomas Alfred; Binus, Stefanie Martina; Holzschuh, Barbara; Petschelt, Anselm; Powers, John M; Berthold, Christine.
Afiliación
  • Koch AT; Dental Clinic 1 - Operative Dentistry and Periodontology, Friedrich-Alexander-University, Erlangen, Germany.
Dent Traumatol ; 30(4): 270-9, 2014 Aug.
Article en En | MEDLINE | ID: mdl-24476378
ABSTRACT

AIM:

The aim was to evaluate the influence of post surface design and luting system on bond strength of quartz-fiber-reinforced composite posts (QFRCPs) luted to root canal dentin. MATERIALS AND

METHODS:

Single-rooted bovine teeth (n = 650) were randomly assigned (13 groups, n = 50), sectioned, endodontically treated, filled, and post space (length 8 mm) prepared. Custom-made plain-surfaced fiber posts (PSXRO) and (both RTD) macroretentive Macro-Lock Post Illusion X-RO (MLXRO) were inserted into the post spaces using six luting systems Ketac Cem (KC), Fuji Plus (FP), RelyX Unicem, Multilink Primer_Multilink, Sealbond Ultima_CoreCem, and LuxaBond_LuxaCore Z. As control, a titanium post was cemented with KC. After water storage (24 h, 37°C), pull-out test was performed, followed by failure mode assessment. Bond strength was calculated in MPa and analyzed using anova, Dunnett-T3-test, and Student's t-test with Bonferroni correction.

RESULTS:

Post design and luting system significantly influenced the bond strength [MPa] (P < 0.05). Compared with the control 4.3 (1.5), all test groups exhibited higher bond strengths (P < 0.05), except for group PSXRO/KC 4.2 (1.0). The remaining bond strengths were PSXRO FP 8.6 (1.5), RelyX Unicem 10.4 (3.4), Multilink Primer_Multilink 12.7 (3.0), SealBond Ultima_CoreCem 12.7 (3.0), LuxaBond_LuxaCore Z 15.7 (2.5), and MLXRO KC 7.2 (2.2), FP 13.4 (2.5), RelyX Unicem 9.2 (2.9), Multilink Primer_Multilink 12.5 (4.5), SealBond Ultima_CoreCem 13.7 (4.6), LuxaBond_LuxaCore Z 20.6 (2.2). The bond strengths of MLXRO were higher than those of PSXRO when luted with KC, FP, and LuxaBond_LuxaCore Z (P < 0.05).

CONCLUSION:

The post surface design and luting system selection influenced the bond strength of conventionally and adhesively luted QFRCPs to bovine root canal dentin.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tratamiento del Conducto Radicular / Técnica de Perno Muñón / Recubrimiento Dental Adhesivo / Restauración Dental Permanente Límite: Animals Idioma: En Revista: Dent Traumatol Asunto de la revista: ODONTOLOGIA / TRAUMATOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tratamiento del Conducto Radicular / Técnica de Perno Muñón / Recubrimiento Dental Adhesivo / Restauración Dental Permanente Límite: Animals Idioma: En Revista: Dent Traumatol Asunto de la revista: ODONTOLOGIA / TRAUMATOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Alemania