Your browser doesn't support javascript.
loading
In vitro scanning accuracy using different aids for multiple implants in the edentulous arch.
Kernen, Florian R; Recca, Mario; Vach, Kirstin; Nahles, Susanne; Nelson, Katja; Flügge, Tabea V.
Afiliación
  • Kernen FR; Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Recca M; Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Vach K; Institute of Medical Biometry and Statistics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Nahles S; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany.
  • Nelson K; Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Flügge TV; Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Berlin, Germany.
Clin Oral Implants Res ; 33(10): 1010-1020, 2022 Oct.
Article en En | MEDLINE | ID: mdl-35861128
ABSTRACT

OBJECTIVES:

Optical impressions of implants in the edentulous arch are challenged by the absence of distinct surface morphology between multiple implant scan bodies. The purpose of this in vitro study was to evaluate a newly developed scan aid in various designs and colors to improve the accuracy of multi-implant scans. MATERIALS AND

METHODS:

A universal scan aid in three different designs (circular, square, irregular) and three different materials (colors beige, gray, white) was applied to the implant scan bodies of a master model of six implants in an edentulous maxilla. Ten scans using an intra-oral scanner of each scan aid were acquired. Reference scanning was performed using a desktop optical scanner. Alignment of scans was performed at the first scan body in a three-dimensional modeling and inspection software and deviations for trueness and precision were calculated using the signed nearest-neighbor method and then statistically analyzed (α = .05).

RESULTS:

Overall, the beige irregular scan aid had the highest trueness and showed significant differences compared to unsplinted scans. The precision showed more heterogenous results and decreased when using the scan aid. Ease of use was observed with the irregular gray scan aid due to its increased elongation at break.

CONCLUSIONS:

The evaluated scan aid led to improved trueness when compared to unsplinted scans. Even though the irregular design in beige color showed highest trueness, the poor fracture strength of the tested material requires further improvement.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Implantes Dentales / Boca Edéntula Límite: Humans Idioma: En Revista: Clin Oral Implants Res Asunto de la revista: ODONTOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Implantes Dentales / Boca Edéntula Límite: Humans Idioma: En Revista: Clin Oral Implants Res Asunto de la revista: ODONTOLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Alemania