ABSTRACT

INTRODUCTION:

At the moment, no commercial model solution is available for the individualisation of the dentition depending on the clinical case scenario. Furthermore, the realistic training of most restorative and prosthodontic procedures on a single dental study model is not possible. The aim of this study was the creation of a new training model to fill this gap. MATERIALS AND

METHODS:

Complete upper and lower jaw models were created based on existing scans and radiological data from a patient. All components for 100 complete models and 1128 teeth for the training were produced with a SLA-printer. Overall, 94 voluntary students attending the first and second preclinical course in prosthodontics tested the functionality of the model with three different tooth types against a standard dental study model and real teeth. After the training, the model was rated in a questionnaire.

RESULTS:

The production of the models and teeth was feasible. The overall rating of the different teeth was worse for type I (Ø 3.6 ± 1.1), significantly better for type II (Ø 2.5 ± 1.0) and type III (Ø 2.4 ± 1.0) than a standard typodont tooth (Ø 2.7 ± 1.1). The new model was rated significantly better overall (Ø 2.6 ± 1.0) than the standard training model (Ø 3.0 ± 1.1).

CONCLUSIONS:

The aim of this study was fulfilled. A superior training model was created with equivalent and better tooth types. The new teeth were outstanding in terms of cost-efficiency, appearance and feeling during preparation.