Effect of clinical and laboratory techniques of cementation on the assessment of marginal and internal fit of prosthetic elements
Pinto, Carolina Chaves; Silva, Leonardo André Lins da; Licurci, Cristiana Almeida de Assis; Canabarro, Antonio.
Afiliação
  • Pinto, Carolina Chaves; Veiga de Almeida University. Rio de Janeiro. BR
  • Silva, Leonardo André Lins da; Veiga de Almeida University. Rio de Janeiro. BR
  • Licurci, Cristiana Almeida de Assis; Veiga de Almeida University. Rio de Janeiro. BR
  • Canabarro, Antonio; Veiga de Almeida University. Rio de Janeiro. BR
Braz. j. oral sci ; 23: e240950, 2024. ilus
Article em En | LILACS, BBO | ID: biblio-1527011
Biblioteca responsável: BR218.1
ABSTRACT

Aim:

The aim of this in vitro study was to compare machine and manual cementation of prosthetic elements by measuring internal and marginal fits.

Methods:

Eighteen anatomic prefabricated abutments were used to manufacture zirconia copings in the Ceramill (n=9) and Lava systems (n=9). The copings were cemented with a fluid consistency addition silicone using a machine (n=18) and manually (n=18) according to the replica technique. They were then cut in the buccal-palatal and mesial-distal directions. The film thickness was photographed using an optical microscope and measured in the internal and marginal regions. The data collected were analyzed by repeated measures ANOVA and Bonferroni's multiple comparison test (∂=.05). The Bland-Altman test was performed to evaluate the agreement between the methods.

Results:

In the evaluation of the internal and marginal misfits, the mean values observed for the cementation performed with the aid of a machine and manually, were as follows angular regions, 76.7 µm and 76.2 µm; linear regions, 60.6 µm and 60.7 µm; incisal region, 144.8 µm and 145.2 µm; marginal region, 40.1 µm and 40.2 µm; and overall mean, 80.4 µm and 80.6 µm, respectively. No significant differences were found between the 2 methods, for any of regions and systems (P>.05). The Bland-Altman test showed agreement between the methods (P>.05) and that the limits of agreement found were clinically acceptable.

Conclusions:

Within the limitations of this in vitro study, we can conclude that cementation using manual techniques or mechanical aid produces the same cement films
Licença
Assuntos

Texto completo: 1 Base de dados: BBO / LILACS Assunto principal: Cimentação / Planejamento de Prótese Dentária / Desenho Assistido por Computador / Adaptação Marginal Dentária Tipo de estudo: Guideline Idioma: En Revista: Braz. j. oral sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: BBO / LILACS Assunto principal: Cimentação / Planejamento de Prótese Dentária / Desenho Assistido por Computador / Adaptação Marginal Dentária Tipo de estudo: Guideline Idioma: En Revista: Braz. j. oral sci Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil