[Application of GORE-TEX Dual Mesh fixing into peritoneum in sigmoid-colostomy to prevent peristomal hernia].
Zhonghua Wei Chang Wai Ke Za Zhi
; 12(5): 480-2, 2009 Sep.
Article
em Zh
| MEDLINE
| ID: mdl-19742339
ABSTRACT
OBJECTIVE:
To investigate the effect of GORE-TEX Dual Mesh fixing into peritoneum in sigmoid-colostomy on the prevention of peristomal hernia.METHODS:
Sixty patients undergone sigmoid-colostomy from Jan. 2003 to Jan. 2005 in the first affiliated hospital of Sun Yat-sen University were selected and randomly divided into two groups. Patients received papillary sigmoid-colostomy through rectus abdominis and peritoneum in control group and GORE-TEX Dual Mesh fixing into peritoneum during sigmoid-colostomy in observation group. Complications and recurrence rate were recorded in follow-up period.RESULTS:
Peristomal hernia occurred in eight patients (8/30) in control group (26.7%), while no hernia happened in observation group (0/30).CONCLUSION:
GORE-TEX Dual Mesh fixing into peritoneum in sigmoid-colostomy can prevent peristomal hernia.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Neoplasias Retais
/
Colo Sigmoide
/
Colostomia
/
Hérnia
Tipo de estudo:
Clinical_trials
/
Etiology_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Zh
Revista:
Zhonghua Wei Chang Wai Ke Za Zhi
Assunto da revista:
GASTROENTEROLOGIA
Ano de publicação:
2009
Tipo de documento:
Article
País de afiliação:
China