Your browser doesn't support javascript.
loading
Highly sensitive electrocatalytic biosensing of hypoxanthine based on functionalization of graphene sheets with water-soluble conducting graft copolymer.
Zhang, Jing; Lei, Jianping; Pan, Rong; Xue, Yadong; Ju, Huangxian.
Afiliação
  • Zhang J; Key Laboratory of Analytical Chemistry for Life Science (Ministry of Education of China), Department of Chemistry, Nanjing University, Nanjing 210093, PR China.
Biosens Bioelectron ; 26(2): 371-6, 2010 Oct 15.
Article em En | MEDLINE | ID: mdl-20729055
A novel electrocatalytic biosensing platform was designed by the functionalization of reduced graphene oxide sheets (RGO) with conducting polypyrrole graft copolymer, poly(styrenesulfonic acid-g-pyrrole) (PSSA-g-PPY), via π-π noncovalent interaction. The resulting nanocomposite could well disperse in water for at least 2 months with a solubility of 3.0 mg mL(-1). The nanocomposite was characterized with atomic force microscopy, X-ray photoelectron spectroscopy, ultraviolet-visible absorption, contact angle measurement, and electrochemical impedance spectroscopy. Based on the advantageous functions of PSSA-g-PPY and RGO, the functional nanocomposite modified platinum electrode showed high electrocatalytic activity toward the oxidation of hydrogen peroxide and uric acid in neutral media. Further, a hypoxanthine biosensor was constructed by combining the modified electrode with the enzymatic reaction of xanthine oxidase. The biosensor exhibited a wide linear response ranging from 3.0×10(-8) to 2.8×10(-5) M with a high sensitivity of 673±4 µA M(-1) cm(-2). The detection limit of 10nM at a signal-to-noise ratio of 3 was one order of magnitude lower than that reported previously. The assay results of hypoxanthine in fish samples were in a good agreement with the reference values. The water-soluble conducting copolymer could serve as an efficient species for functionalization and solubilization of graphene sheets in biosensing and biocatalytic applications.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Poliestirenos / Pirróis / Água / Técnicas Biossensoriais / Condutometria / Hipoxantina / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Poliestirenos / Pirróis / Água / Técnicas Biossensoriais / Condutometria / Hipoxantina / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2010 Tipo de documento: Article