Your browser doesn't support javascript.
loading
Preparation of molecularly imprinted polymers on the surface of magnetic carbon nanotubes with a pseudo template for rapid simultaneous extraction of four fluoroquinolones in egg samples.
Xiao, Deli; Dramou, Pierre; Xiong, Nanqian; He, Hua; Yuan, Danhua; Dai, Hao; Li, Hui; He, Xiaomei; Peng, Jun; Li, Nan.
Afiliação
  • Xiao D; Department of Analytical Chemistry, China Pharmaceutical University, 24 Tongjia Lane, Nanjing 210009, Jiangsu, China.
Analyst ; 138(11): 3287-96, 2013 Jun 07.
Article em En | MEDLINE | ID: mdl-23620872
ABSTRACT
Fluoroquinolones (FQs) have emerged as one of the most important class of antibiotics. Due to their low concentration in bio-matrix samples which contain a lot of interfering substances, the efficient solid phase extraction and accurate determination of FQs remain a challenge. In this paper, a new strategy for the isolation and enrichment of FQs from egg samples was obtained by molecularly imprinted polymers on the surface of magnetic carbon nanotubes (MCNTs@MIP), which not only can be collected and separated rapidly by an external magnetic field, but also have a high specific surface area, outstanding mechanical properties and specific recognition for FQs. MCNTs@MIP were prepared using ofloxacin as a pseudo template, methacrylic acid as a functional monomer, and ethylene glycol dimethacrylate as a cross-linker. The characteristics of the MCNTs@MIP were assessed by transmission electron microscopy (TEM), multipoint Brunauer-Emmett-Teller (BET) analysis, vibrating sample magnetometry (VSM), X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy. The results of the adsorption experiments not only demonstrated rapid dynamic adsorption but also showed a high selectivity toward FQs. An extraction method using MCNTs@MIP coupled with high performance liquid chromatography (HPLC) was developed for the determination of four FQs in egg samples. The recovery of four FQs ranged from 95.2% ± 3.2% to 100.7% ± 3.1% and the detection limits ranged from 0.25-0.40 ng g(-1). The results demonstrate that the proposed method based on pseudo template MCNTs@MIP is a promising approach for the preconcentration, purification, and simultaneous analysis of four FQs in bio-matrix samples.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Óvulo / Polímeros / Fluoroquinolonas / Nanotubos de Carbono / Impressão Molecular Idioma: En Revista: Analyst Ano de publicação: 2013 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Óvulo / Polímeros / Fluoroquinolonas / Nanotubos de Carbono / Impressão Molecular Idioma: En Revista: Analyst Ano de publicação: 2013 Tipo de documento: Article País de afiliação: China