Your browser doesn't support javascript.
loading
Increased Femoral Head Offset is Associated With Elevated Metal Ions in Asymptomatic Patients With Metal-on-Polyethylene Total Hip Arthroplasty.
Martin, John R; Camp, Christopher L; Wyles, Cody C; Taunton, Michael J; Trousdale, Robert T; Lewallen, David G.
Afiliação
  • Martin JR; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Camp CL; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Wyles CC; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Taunton MJ; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Trousdale RT; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
  • Lewallen DG; Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
J Arthroplasty ; 31(12): 2814-2818, 2016 12.
Article em En | MEDLINE | ID: mdl-27436501
ABSTRACT

BACKGROUND:

Predisposing factors for trunnionosis and elevated metal ion levels in metal-on-polyethylene (MOP) total hip arthroplasty (THA) are currently unknown.

METHODS:

This retrospective cohort study enrolled 80 consecutive patients (43 males) with an asymptomatic MOP THA at 2- to 5-year follow-up and no other metal implants. Serum cobalt (Co) and chromium (Cr) levels were collected at the time of enrollment, and retrospective review was performed regarding demographic, implant, and surgical characteristics. Mean age at the time of surgery was 65.7 years (range 35.6-85.9 years), and mean postoperative follow-up was 28.7 months (range 24.4-58.9 months).

RESULTS:

Femoral head offset was the only evaluated factor shown to increase serum Co ion levels above baseline within the cohort. Mean difference in Co level for high and low offset implants was 0.58 ppb (95% confidence interval [CI] = 0.05-1.11 ppb; P = .03). Mean difference in Cr level for high and low offset implants was 0.19 ppb (95% CI = -0.23 to 0.60 ppb; P = .37). Mean difference in Co level for small and large femoral heads was 0.20 ppb (95% CI = -0.41 to 0.81 ppb; P = .59). Mean difference in Cr level for small and large femoral heads was 0.28 ppb (95% CI = -0.18 to 0.74 ppb; P = .06). Age, gender, Harris Hip Score, and implant duration were not associated with changes in metal ion levels.

CONCLUSION:

Femoral head offset appears to be an important source of elevated metal ion levels in MOP THA. Further studies will be needed to understand if increasing femoral head offset is associated with subsequent adverse local tissue reactions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromo / Cobalto / Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cromo / Cobalto / Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2016 Tipo de documento: Article