Your browser doesn't support javascript.
loading
Dimensional changes from the sintering process and fit of Y-TZP copings: Micro-CT analysis.
Edwards Rezende, Carlos Eduardo; Sanches Borges, Ana Flávia; Macedo, Rander Moreira; Rubo, José Henrique; Griggs, Jason Alan.
Afiliação
  • Edwards Rezende CE; Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla 9-75, Bauru, SP 17012-901, Brazil; Post-Graduation Program in Clinical Dentistry, Dental School, Positivo University, 5300 Pedro Viriato Parigot de Souza Rd., Curitiba, PR 81280-330, B
  • Sanches Borges AF; Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla 7-35, Bauru, SP 17012-901, Brazil. Electronic address: afborges@fob.usp.br.
  • Macedo RM; Post-Graduation Program in Clinical Dentistry, Dental School, Positivo University, 5300 Pedro Viriato Parigot de Souza Rd., Curitiba, PR 81280-330, Brazil. Electronic address: mmrander@hotmail.com.
  • Rubo JH; Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla 9-75, Bauru, SP 17012-901, Brazil. Electronic address: jrubo@fob.usp.br.
  • Griggs JA; Department of Biomedical Materials Science, University of Mississippi Medical Center,2500 North State Street, Jackson, MS 39216-4505, USA. Electronic address: jgriggs@umc.edu.
Dent Mater ; 33(11): e405-e413, 2017 11.
Article em En | MEDLINE | ID: mdl-28939084
OBJECTIVE: To evaluate the dimensional changes from the sintering process of Y-TZP and relate them to the fit of zirconia copings. METHODS: The sintering shrinkage rate (SSR) was obtained from the measurement of geometric specimens (4×4×2mm). Thirty-six zirconia copings made using CAD/CAM were equally divided into three groups (n=12): ZMAX - IPS e.max ZirCAD (Ivoclar Vivadent, Liechtenstein); ZYZ - InCeram YZ (Vita Zahnfabrik, Germany); and ZK - Zirklein (Zirklein, Brazil). The copings were scanned in micro-CT before and after sintering so that SSR was obtained. The SSR of geometrical specimens and copings was compared to each other and those the manufacturers reported (ANOVA-2 and Tukey, p≤.05). The copings were settled on an abutment and taken to the micro-CT to evaluate their marginal and internal fit. The data enabled the statistical comparison (ANOVA-2 and Tukey, p≤.05) between groups and measurement sites and between the fit obtained with that stipulated by the CAD/CAM software (80µm) (Dunnett test, p≤.05). RESULTS: All groups showed statistical differences between the SSR the manufacturer reported and those obtained experimentally and between the SSR of the geometric specimens and copings. In general, the SSR of the copings showed no uniformity. There was no statistical difference among the groups for marginal fit, with differences only for internal fit and between the different regions measured. The fit obtained experimentally differed from the internal space determined in the CAD/CAM software. SIGNIFICANCE: The lack of uniformity of sintering shrinkage might lead to a non-uniform internal fit of Y-TZP copings.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ítrio / Zircônio / Cerâmica / Planejamento de Prótese Dentária / Coroas / Materiais Dentários / Microtomografia por Raio-X Limite: Humans Idioma: En Revista: Dent Mater Assunto da revista: ODONTOLOGIA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ítrio / Zircônio / Cerâmica / Planejamento de Prótese Dentária / Coroas / Materiais Dentários / Microtomografia por Raio-X Limite: Humans Idioma: En Revista: Dent Mater Assunto da revista: ODONTOLOGIA Ano de publicação: 2017 Tipo de documento: Article