Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing Study.
Chiastra, Claudio; Grundeken, Maik J; Collet, Carlos; Wu, Wei; Wykrzykowska, Joanna J; Pennati, Giancarlo; Dubini, Gabriele; Migliavacca, Francesco.
Afiliação
  • Chiastra C; Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy. claudio.chiastra@polimi.it.
  • Grundeken MJ; The Heart Center, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • Collet C; The Heart Center, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • Wu W; Department of Cardiology, Universitair Ziekenhuis Brussel, Brussels, Belgium.
  • Wykrzykowska JJ; Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy.
  • Pennati G; Department of Mechanical Engineering, University of Texas at San Antonio, San Antonio, TX, USA.
  • Dubini G; The Heart Center, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
  • Migliavacca F; Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy.
Cardiovasc Eng Technol ; 9(3): 415-426, 2018 09.
Article em En | MEDLINE | ID: mdl-29777394
The treatment of coronary bifurcations is challenging for interventional cardiologists. The Tryton stent (Tryton Medical, Inc., USA) is one of the few devices specifically designed for coronary bifurcations that underwent large clinical trials. Although the manufacturer provides specific recommendations to position the stent in the bifurcation side branch (SB) according to four radio-opaque markers under angiographic guidance, wrong device positioning may accidentally occur. In this study, the virtual bench testing approach was used to investigate the impact of wrong positioning of the Tryton stent in coronary bifurcations in terms of geometrical and biomechanical criteria. A finite element model of the left anterior descending/first diagonal coronary bifurcation was created with a 45° distal angle and realistic lumen diameters. A validated model of the Tryton stent mounted on stepped delivery balloon was used. All steps of the Tryton deployment sequence were simulated. Three Tryton positions, namely 'proximal', 'recommended', and 'distal' positions, obtained by progressively implanting the stent more distally in the SB, were compared. The 'recommended' case exhibited the lowest ostial area stenosis (44.8 vs. 74.3% ('proximal') and 51.5% ('distal')), the highest diameter at the SB ostium (2.81 vs. 2.70 mm ('proximal') and 2.54 mm ('distal')), low stent malapposition (9.9 vs. 16.3% ('proximal') and 8.5% ('distal')), and the lowest peak wall stress (0.37 vs. 2.20 MPa ('proximal') and 0.71 MPa ('distal')). In conclusion, the study shows that a 'recommended' Tryton stent positioning may be required for optimal clinical results.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Simulação por Computador / Teste de Materiais / Angioplastia Coronária com Balão / Stents / Vasos Coronários / Estenose Coronária / Modelos Cardiovasculares Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Cardiovasc Eng Technol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Simulação por Computador / Teste de Materiais / Angioplastia Coronária com Balão / Stents / Vasos Coronários / Estenose Coronária / Modelos Cardiovasculares Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Revista: Cardiovasc Eng Technol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Itália