Your browser doesn't support javascript.
loading
Novel functional fiber loaded with carbon dots for the deep removal of Cr(VI) by adsorption and photocatalytic reduction.
Xiao, Junfeng; Cheng, Yuanpeng; Guo, Caixia; Liu, Xiangting; Zhang, Bing; Yuan, Siguo; Huang, Jiajia.
Afiliação
  • Xiao J; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China.
  • Cheng Y; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China.
  • Guo C; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China.
  • Liu X; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China.
  • Zhang B; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China.
  • Yuan S; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China.
  • Huang J; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China. Electronic address: huangjiajia@zzu.edu.cn.
J Environ Sci (China) ; 83: 195-204, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31221382
A novel functional fiber (PAN-CDs) loaded with carbon dots (CDs) with excellent photoreduction and adsorption properties for Cr(VI) was prepared via an amidization reaction between the CDs' carboxyl groups and amine groups on polyacrylonitrile (PAN)-based ion exchange fibers, which could completely preserve the fluorescence properties of the CDs. The photoluminescence (PL), photocatalysis and adsorption properties of PAN-CDs were characterized and analyzed. The PAN-CDs possess high adsorption capacity (297.6 mg/g) and excellent kinetic behavior (attaining adsorption equilibrium in 30 min) for Cr(VI) adsorption. Furthermore, the residual Cr(VI) (approximately 3 mg/L) after adsorption could be removed completely by subsequent photoreduction by the PAN-CDs. The Cr-saturated PAN-CDs could be easily separated by filtering and regenerated, with no observable decay of removal efficiency after five regeneration cycles. In addition, due to the PL quenching action of Cr(VI), the PAN-CDs can also be used as sensor for quantitative detection of trace Cr(VI) in aqueous solution.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Cromo Idioma: En Revista: J Environ Sci (China) Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Cromo Idioma: En Revista: J Environ Sci (China) Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China