Your browser doesn't support javascript.
loading
Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model.
Choe, Jeong Cheon; Park, Jong Ha; Lee, Han Cheol; Park, Tae Sik; Ahn, Jinhee; Park, Jin Sup; Lee, Hye Won; Oh, Jun-Hyok; Choi, Jung Hyun; Cha, Kwang Soo; Yim, Changyong; Jeon, Sangmin.
Afiliação
  • Choe JC; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Park JH; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Lee HC; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea. glaraone@hanmail.net.
  • Park TS; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Ahn J; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Park JS; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Lee HW; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Oh JH; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Choi JH; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Cha KS; Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea.
  • Yim C; Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea.
  • Jeon S; Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea.
J Mater Sci Mater Med ; 31(12): 122, 2020 Nov 28.
Article em En | MEDLINE | ID: mdl-33247775
ABSTRACT
Device-related problems of drug-eluting stents, including stent thrombosis related to antiproliferative drugs and polymers, can cause adverse events such as inflammation and neointimal hyperplasia. Stent surface modification, wherein the drug and polymer are not required, may overcome these problems. We developed hydrophilic polyethylene glycol (PEG)-coating and hydrophobic octadecylthiol (ODT)-coating stents without a drug and polymer and evaluated their histopathologic response in a porcine coronary restenosis model. PEG-coating stents (n = 12), bare-metal stents (BMS) (n = 12), and ODT-coating stents (n = 10) were implanted with oversizing in 34 porcine coronary arteries. Four weeks later, the histopathologic response, arterial injury, inflammation, and fibrin scores were analyzed. A p value < 0.05 was considered statistically significant. There were significant differences in the internal elastic lamina area, lumen area, neointimal area, percent area of stenosis, arterial injury score, inflammation score, and fibrin score among the groups. Compared to the BMS or ODT-coating stent group, the PEG-coating stent group had significantly increased internal elastic lamina and lumen area (all p < 0.001) and decreased neointimal area and percent area of stenosis (BMS p = 0.03 and p < 0.001, respectively; ODT-coating p = 0.013 and p < 0.001, respectively). Similarly, the PEG-coating group showed significantly lower inflammation and fibrin scores than the BMS or ODT-coating groups (BMS p = 0.013 and p = 0.007, respectively; ODT-coating p = 0.014 and p = 0.008, respectively). In conclusion, hydrophilic PEG-coating stent implantation was associated with lower inflammatory response, decreased fibrin deposition, and reduced neointimal hyperplasia than BMS or hydrophobic ODT-coating stent implantation in the porcine coronary restenosis model.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Materiais Revestidos Biocompatíveis / Reestenose Coronária / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Evaluation_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Mater Sci Mater Med Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Materiais Revestidos Biocompatíveis / Reestenose Coronária / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Evaluation_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Mater Sci Mater Med Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2020 Tipo de documento: Article