Your browser doesn't support javascript.
loading
Correlation between Polysomnographic Parameters and Tridimensional Changes in the Upper Airway of Obstructive Sleep Apnea Patients Treated with Mandibular Advancement Devices.
Camañes-Gonzalvo, Sara; Marco-Pitarch, Rocío; Plaza-Espín, Andrés; Puertas-Cuesta, Javier; Agustín-Panadero, Rubén; Fons-Font, Antonio; Fons-Badal, Carla; García-Selva, Marina.
Afiliação
  • Camañes-Gonzalvo S; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
  • Marco-Pitarch R; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
  • Plaza-Espín A; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
  • Puertas-Cuesta J; Medical School of Medicine, Universidad Católica de Valencia, 46002 Valencia, Spain.
  • Agustín-Panadero R; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
  • Fons-Font A; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
  • Fons-Badal C; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
  • García-Selva M; Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
J Clin Med ; 10(22)2021 Nov 11.
Article em En | MEDLINE | ID: mdl-34830533
BACKGROUND: The effectiveness of mandibular advancement devices has been solidly demonstrated in the past. They are considered a valid alternative treatment to continuous positive airway pressure for patients with obstructive sleep apnea. Nevertheless, the relationship between polysomnographic parameters and the increase in the volume of the upper airway in patients with obstructive sleep apnea syndrome has not been clearly established so far. This study aimed to determine the impact of these oral appliances upon the volume of the airway after the device titration phase and correlate it with the degree of mandibular advancement and the improvement of polysomnographic parameters. METHODS: All patients were diagnosed by polysomnography and were treated with a customized, titratable mandibular advancement device. Three-dimensional volumetric measurements were performed using cone beam computed tomography. RESULTS: The present study included 45 patients diagnosed with obstructive sleep apnea hypopnea syndrome (mild in 23 patients, moderate in 11 and severe in 11). Forty-four percent of the patients presented with an apnea hypopnea index <5/h at the end of treatment. The volume of the upper airway increased an average of 4.3 ± 5.9 cm3, this represents a percentage increase of 20.9%, which was significantly correlated with an apnea hypopnea index and a minimum oxygen saturation improvement. CONCLUSIONS: The mandibular advancement device used was found to be effective in improving polysomnographic parameters. Moreover, the oral appliance was able to significantly increase the tridimensional dimensions of the upper airway. Moreover, this finding was correlated with a reduction in the apnea hypopnea index (p = 0.007) and an increase on minimum oxygen saturation (p = 0.033).
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha