Your browser doesn't support javascript.
loading
A comparative analysis of dual-axis implants placed into maxillary anterior extraction sockets versus virtual planning with uniaxial implants: A simulated cone beam computed tomography study of implant length and diameter.
Song, Seung Jun; Chu, Stephanie M; Chu, Stephen J; Saito, Hanae; Levin, Barry P; Egbert, Nicholas L; Sarnachiaro, Guido O; Tarnow, Dennis P.
Afiliação
  • Song SJ; Division of Prosthodontics, Columbia University College of Dental Medicine, New York, New York, USA.
  • Chu SM; Post-Graduate Periodontics, New York Harbor Healthcare System, US Department of Veterans Affairs, New York, New York, USA.
  • Chu SJ; Private Practice.
  • Saito H; Private Practice.
  • Levin BP; Ashman Department of Periodontology and Implant Dentistry, Department of Prosthodontics, New York University College of Dentistry, New York, New York, USA.
  • Egbert NL; Department of Advanced Sciences & Therapeutics, Division of Periodontics, University of Maryland School of Dentistry, Baltimore, Maryland, USA.
  • Sarnachiaro GO; Private Practice.
  • Tarnow DP; Department of Periodontology, University of Pennsylvania School of Dental Medicine, Philadelphia, Pennsylvania, USA.
J Esthet Restor Dent ; 35(1): 206-214, 2023 01.
Article em En | MEDLINE | ID: mdl-36628940
ABSTRACT

OBJECTIVE:

The biaxial nature of the anterior maxilla poses a surgical and restorative challenge in implant dentistry. The present study sought to investigate the apical socket perforation rate (ASPR) from a simulated uniaxial implant placement and to determine the effect of implant length and diameter on ASPR when a uniaxial implant was placed compared with the orientation of the pre-existing dual-axis implant. MATERIAL AND

METHOD:

Cone beam computed tomography (CBCT) scans from the database of three private practices were searched for patients who received dual-axis implants within the esthetic zone in immediate tooth replacement therapy. A uniaxial implant was virtually placed using the pre-existing screw access channel of the dual-axis implant as a reference. The closest length and diameter were selected for the simulated implant. ASPR by the uniaxial implant was recorded. In addition, the affordable maximum length of a corresponding uniaxial implant that would avoid apical socket perforation was measured.

RESULT:

Eighty-one patients with a total of 101 dual-axis dental implants were selected for analysis. A simulated virtual surgical planning with uniaxial implants revealed high ASPR (48.51%). When the length of the uniaxial implant was reduced to 11 and 9 mm, ASPR was decreased to 41.58% and 20.79%, respectively.

CONCLUSION:

Dual-axis implant design effectively evades anatomical challenges in the anterior maxilla (esthetic zone). Considering the current evidence, efforts should be made to carefully consider the angular disparity between the extraction socket-alveolus complex and the future restorative emergence so that a harmonious biologic-esthetic result may be more predictably and consistently obtained.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários para Um Único Dente / Carga Imediata em Implante Dentário Limite: Humans Idioma: En Revista: J Esthet Restor Dent Assunto da revista: ODONTOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implantes Dentários para Um Único Dente / Carga Imediata em Implante Dentário Limite: Humans Idioma: En Revista: J Esthet Restor Dent Assunto da revista: ODONTOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos