Your browser doesn't support javascript.
loading
Long-Term Ultrasound Twinkling Detectability and Safety of a Polymethyl Methacrylate Soft Tissue Marker Compared to Conventional Breast Biopsy Markers-A Preclinical Study in a Porcine Model.
Lee, Christine U; Urban, Matthew W; Hesley, Gina K; Wood, Benjamin G; Meier, Thomas R; Chen, Beiyun; Kassmeyer, Blake A; Larson, Nicholas B; Lee Miller, A; Herrick, James L; Jakub, James W; Piltin, Mara A.
Afiliação
  • Lee CU; Department of Radiology, Division of Breast Imaging and Intervention, Mayo Clinic, Rochester, MD, USA. Electronic address: lee.christine@mayo.edu.
  • Urban MW; Department of Radiology, Division of Radiology Research, Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MD, USA.
  • Hesley GK; Department of Radiology, Division of Breast Imaging and Intervention, Mayo Clinic, Rochester, MD, USA.
  • Wood BG; Mayo Graduate School, Mayo Clinic, Rochester, MD, USA.
  • Meier TR; Department of Comparative Medicine, Mayo Clinic, Rochester, MD, USA.
  • Chen B; Department of Laboratory Medicine and Pathology, Division of Anatomic Pathology, Mayo Clinic, Rochester, MD, USA.
  • Kassmeyer BA; Department of Quantitative Health Sciences, Division of Clinical Trials and Biostatistics, Mayo Clinic, Rochester, MD, USA.
  • Larson NB; Department of Quantitative Health Sciences, Division of Clinical Trials and Biostatistics, Mayo Clinic, Rochester, MD, USA.
  • Lee Miller A; Biomaterials and Histomorphometry Core, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MD, USA.
  • Herrick JL; Biomaterials and Histomorphometry Core, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MD, USA.
  • Jakub JW; Department of Surgery, Division of Surgical Oncology, Mayo Clinic, Jacksonville, FL USA.
  • Piltin MA; Department of Surgery, Breast and Melanoma Surgical Oncology, Mayo Clinic, Rochester, MD, USA.
Ultrasound Med Biol ; 50(7): 1001-1009, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38575416
ABSTRACT

OBJECTIVE:

We have studied the use of polymethyl methacrylate (PMMA) as an alternative biopsy marker that is readily detectable with ultrasound Doppler twinkling in cases of in vitro, ex vivo, or limited duration in vivo settings. This study investigates the long-term safety and ultrasound Doppler twinkling detectability of a PMMA breast biopsy marker following local perturbations and different dwell times in a 6-mo animal experiment.

METHODS:

This study, which was approved by our Institutional Animal Care and Use Committee, involved three pigs and utilized various markers, including PMMA (Zimmer Biomet), 3D-printed, and Tumark Q markers. Markers were implanted at different times for each pig. Mesh material or ethanol was used to induce a local inflammatory reaction near certain markers. A semiquantitative twinkling score assessed twinkling for actionable localization during monthly ultrasounds. At the primary endpoint, ultrasound-guided localization of lymph nodes with detectable markers was performed. Following surgical resection of the localized nodes, histomorphometric analysis was conducted to evaluate for tissue ingrowth and the formation of a tissue rind around the markers.

RESULTS:

No adverse events occurred. Twinkling scores of all markers for all three pigs decreased gradually over time. The Q marker exhibited the highest mean twinkling score followed by the PMMA marker, PMMA with mesh, and Q with ethanol. The 3D-printed marker with mesh and PMMA with ethanol had the lowest scores. All wire-localized lymph nodes were successfully resected. Despite varying percentages of tissue rind around the markers and a significant reduction in overall twinkling (p < 0.001) over time, mean PMMA twinkling scores remained clinically actionable at 6 and 5 mo using a General Electric C1-6 probe and 9L-probe, respectively.

CONCLUSIONS:

In this porcine model, the PMMA marker demonstrates an acceptable safety profile. Clinically actionable twinkling aids PMMA marker detection even after 6 mo of dwell time in porcine lymph nodes. The Q marker maintained the greatest twinkling over time compared to all the other markers studied.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polimetil Metacrilato Limite: Animals Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polimetil Metacrilato Limite: Animals Idioma: En Revista: Ultrasound Med Biol Ano de publicação: 2024 Tipo de documento: Article