Your browser doesn't support javascript.
loading
Influence of a mesial cantilever on stress, strain, and axial force in fixed partial dentures with a distally tilted implant in the atrophic posterior maxilla.
Fan, Xiaohui; Chen, Li; Chen, Qiuren; Wang, Feng; Wu, Yiqun; Sun, Yuanyuan.
Afiliação
  • Fan X; Shanghai Key Laboratory of Advanced High Temperature Materials and Precision Forming, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Chen L; Yangtze Delta Advanced Material Research Institute, Suzhou, China.
  • Chen Q; Yangtze Delta Advanced Material Research Institute, Suzhou, China.
  • Wang F; Department of Second Dental Center, Shanghai Ninth People's Hospital, School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology, Shanghai, China.
  • Wu Y; Department of Second Dental Center, Shanghai Ninth People's Hospital, School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology, Shanghai, China.
  • Sun Y; Department of Second Dental Center, Shanghai Ninth People's Hospital, School of Medicine; College of Stomatology, Shanghai Jiao Tong University; National Center for Stomatology; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology, Shanghai, China.
J Prosthodont Res ; 2024 Apr 12.
Article em En | MEDLINE | ID: mdl-38616127
ABSTRACT

PURPOSE:

This study aimed to investigate whether the presence of a mesial cantilever influences the biomechanical behavior and screw loosening in fixed partial dentures (FPDs) with a distally tilted implant in the atrophic posterior maxilla and where to best place the distal implant.

METHODS:

Two configurations of implant-supported four-unit FPDs were modelled using finite element analysis. Five interabutment distances were considered. The stress and strain distributions in the implants, abutments, and prosthetic screws were verified under occlusal loading. The development of the axial force on the abutments and screws was also examined. Two-sample t-tests were used to identify differences (P < 0.05).

RESULTS:

The von Mises stress distributions of the components in the two configurations were similar, as were the maximum plastic strains of the distal prosthetic screws, distal implants, and 30° abutments. The difference in the maximum plastic strains of the straight abutments was statistically significant. The preload of the 30° abutment screws was significantly reduced after the initial loading. In the absence of a mesial cantilever, the axial force on the straight abutments increased. However, when a mesial cantilever was used, the preload of the straight abutments was maintained, and the axial force on the prosthetic screws fluctuated less. The axial force fluctuation of the abutments gradually decreased as the interabutment distance increased.

CONCLUSIONS:

Mesial cantilever usage had minimal effect on stress or strain distribution in FPD implants, abutments, or prostheses. However, it helped resist screw loosening. The distal screw access hole was preferably positioned close to the prosthetic end.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Idioma: En Revista: J Prosthodont Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China