Your browser doesn't support javascript.
loading
The Effectiveness of Osseodensification Drilling versus the Conventional Surgical Technique on Implant Stability: A Clinical Trial.
Fontes Pereira, João; Costa, Rosana; Nunes Vasques, Miguel; Relvas, Marta; Braga, Ana Cristina; Salazar, Filomena; Infante da Câmara, Marco.
Afiliação
  • Fontes Pereira J; Department of Medicine and Oral Surgery, University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
  • Costa R; Oral Pathology and Rehabilitation Research Unit (UNIPRO), University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
  • Nunes Vasques M; Department of Medicine and Oral Surgery, University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
  • Relvas M; Oral Pathology and Rehabilitation Research Unit (UNIPRO), University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
  • Braga AC; Department of Medicine and Oral Surgery, University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
  • Salazar F; Oral Pathology and Rehabilitation Research Unit (UNIPRO), University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
  • Infante da Câmara M; Department of Medicine and Oral Surgery, University Institute of Health Sciences (IUCS-CESPU), 4585-116 Gandra, Portugal.
J Clin Med ; 13(10)2024 May 15.
Article em En | MEDLINE | ID: mdl-38792453
ABSTRACT
Background/

Objective:

To ensure that implants are able to support prosthetic rehabilitation, a stable and functional union between the bone and the implant surface is crucial to its stability and success. To increase bone volume and density and excel bone-implant contact, a novel drilling method, called osseodensification (OD), was performed. To assess the effectiveness of the osseodensification drilling protocol versus the conventional surgical technique on implant stability.

Methods:

Bone Level Tapered Straumann implants were placed side-by-side with both OD and subtractive conventional drilling (SD) in 90 patients from CESPU-Famalicão clinical unit. IT was measured using a manual torque wrench, and the Implant stability quotient (ISQ) value was registered using the Osstell® IDX.

Results:

According to the multifactorial ANOVA, there were statistically significant differences in the mean IT values due to the arch only (F(1.270) = 4.702, p-value = 0.031 < 0.05). Regarding the length of the implant, there were statistically significant differences in the mean IT in the OD group (p = 0.041), with significantly lower mean IT values for the Regular implants compared to the Long. With respect to the arch, the analyses of the overall ISQ values showed an upward trend in both groups in the maxilla and mandible. High levels of IT also showed high ISQ values, which represent good indicators of primary stability.

Conclusions:

OD does not have a negative influence on osseointegration compared to conventional subtractive osteotomy.