The use of Mitek anchors to secure mesh in abdominal wall reconstruction.
Francis, K R; Hoffman, L A; Cornell, C; Cortese, A.
Afiliação
  • Francis KR; Department of Orthopedics, New York Hospital/Cornell University Medical Center, New York.
Plast Reconstr Surg ; 93(2): 419-21, 1994 Feb.
Article em En | MEDLINE | ID: mdl-8310039
ABSTRACT
Abdominal wall complications of TRAM flap breast reconstruction are well described. Synthetic mesh abdominal reinforcement is believed to decrease the incidence of these complications. An innovative technique with commonly available suture anchors has been used in a case of recurrent abdominal laxity after a TRAM flap. Osseous fixation of synthetic mesh with the Mitek GII suture anchor will undoubtedly be used more widely in abdominal wall reconstruction.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Retalhos Cirúrgicos / Telas Cirúrgicas / Suturas / Mamoplastia / Músculos Abdominais / Hérnia Umbilical Tipo de estudo: Etiology_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Plast Reconstr Surg Ano de publicação: 1994 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Retalhos Cirúrgicos / Telas Cirúrgicas / Suturas / Mamoplastia / Músculos Abdominais / Hérnia Umbilical Tipo de estudo: Etiology_studies Limite: Female / Humans / Middle aged Idioma: En Revista: Plast Reconstr Surg Ano de publicação: 1994 Tipo de documento: Article