Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Radiol ; 79(3): e468-e474, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38185579

RESUMEN

AIM: To investigate the relevance of dynamic contrast enhanced imaging (DCE) within multiparametric magnetic resonance imaging (mpMRI) for the detection of clinically significant prostate cancer (csPC) depending on reader experience. MATERIALS AND METHODS: Consecutive patients with 3 T mpMRI and subsequent combined MRI/ultrasound fusion-guided targeted and systematic biopsy from January to September 2019 were included. All mpMRI examinations were read separately by two less experienced (R1; <500 prostate MRI) and two expert radiologists (R2; >5,000 prostate MRI) in consensus and blinded re-read as biparametric MRI (bpMRI). The primary endpoint was the performance comparison of mpMRI versus bpMRI of R1 and R2. RESULTS: Fifty-three of 124 patients had csPC (43%). The PI-RADS agreement of bpMRI and mpMRI was fair for R1 (κ = 0.373) and moderate for R2 (κ = 0.508). R1 assessed 11 csPC with PI-RADS ≤3 (20.8%) on mpMRI and 12 (22.6%) on bpMRI (R2: 1 [1.9%] and 6 [11.3%], respectively). Sensitivity for csPC of mpMRI was 79.3% (NPV 79.3%) for R1 and 98.1% (NPV 97.5%) for R2 (bpMRI: 77.4% [NVP 75.5%] and 86.8% [NPV 84.4%], respectively). Specificity of mpMRI for csPC was 59.2% for R1 and 54.9% for R2 (bpMRI: 52.1% and 53.5%, respectively). Overall accuracy of mpMRI was 79.8% for R1 compared to bpMRI 66.9% (p=0.017; R2: 87.1% and 81.5%; p=0.230). CONCLUSION: Prostate MRI benefits from reader experience. Less experienced readers missed a relevant proportion of csPC with mpMRI and even more with bpMRI. The overall performance of expert readers was comparable for mpMRI and bpMRI but DCE enabled detection of some further ISUP 2 PC.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Biopsia , Estudios Retrospectivos
2.
Eur Radiol ; 32(4): 2351-2359, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34748064

RESUMEN

OBJECTIVES: T o evaluate the value of multiparametric MRI (mpMRI) for the prediction of prostate cancer (PCA) aggressiveness. METHODS: In this single center cohort study, consecutive patients with histologically confirmed PCA were retrospectively enrolled. Four different ISUP grade groups (1, 2, 3, 4-5) were defined and fifty patients per group were included. Several clinical (age, PSA, PSAD, percentage of PCA infiltration) and mpMRI parameters (ADC value, signal increase on high b-value images, diameter, extraprostatic extension [EPE], cross-zonal growth) were evaluated and correlated within the four groups. Based on combined descriptors, MRI grading groups (mG1-mG3) were defined to predict PCA aggressiveness. RESULTS: In total, 200 patients (mean age 68 years, median PSA value 8.1 ng/ml) were analyzed. Between the four groups, statistically significant differences could be shown for age, PSA, PSAD, and for MRI parameters cross-zonal growth, high b-value signal increase, EPE, and ADC (p < 0.01). All examined parameters revealed a significant correlation with the histopathologic biopsy ISUP grade groups (p < 0.01), except PCA diameter (p = 0.09). A mixed linear model demonstrated the strongest prediction of the respective ISUP grade group for the MRI grading system (p < 0.01) compared to single parameters. CONCLUSIONS: MpMRI yields relevant pre-biopsy information about PCA aggressiveness. A combination of quantitative and qualitative parameters (MRI grading groups) provided the best prediction of the biopsy ISUP grade group and may improve clinical pathway and treatment planning, adding useful information beyond PI-RADS assessment category. Due to the high prevalence of higher grade PCA in patients within mG3, an early re-biopsy seems indicated in cases of negative or post-biopsy low-grade PCA. KEY POINTS: • MpMRI yields relevant pre-biopsy information about prostate cancer aggressiveness. • MRI grading in addition to PI-RADS classification seems to be helpful for a size independent early prediction of clinically significant PCA. • MRI grading groups may help urologists in clinical pathway and treatment planning, especially when to consider an early re-biopsy.


Asunto(s)
Neoplasias de la Próstata , Anciano , Estudios de Cohortes , Humanos , Biopsia Guiada por Imagen , Imagen por Resonancia Magnética/métodos , Masculino , Clasificación del Tumor , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Estudios Retrospectivos
3.
Eur Radiol ; 30(11): 6042-6051, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32591887

RESUMEN

OBJECTIVES: To assess the ability of multiparametric MRI (mp-MRI) of the prostate to exclude prostate cancer (PCa) progression during monitoring patients on active surveillance (AS). METHODS: One hundred forty-seven consecutive patients on AS with mp-MRI (T2WI, DWI, DCE-MRI) at 3T were initially enrolled. Fifty-five received follow-up mp-MRI after a minimum interval of 12 months and subsequent targeted MR/US fusion-guided biopsy (FUS-GB) plus concurrent systematic transrectal ultrasound-guided (TRUS-GB) biopsy as reference standard. Primary endpoint was the negative predictive value (NPV) of the follow-up mp-MRI to exclude histopathologic tumor progression using PRECISE recommendations. Secondary endpoints were the positive predictive value (PPV), sensitivity, specificity, Gleason score (GS) upgrades, and comparison of biopsy method. RESULTS: Of 55 patients, 29 (53%) had a GS upgrade on re-biopsy. All 29 patients showed a tumor progression on follow-up mp-MRI. Fifteen of 55 patients (27%) displayed signs of tumor progression, but had stable GS on re-biopsy. None of the 11 patients (20%) without signs of progression on follow-up mp-MRI had a GS upgrade on re-biopsy. The NPV was 100%, PPV was 66%, sensitivity was 100%, and specificity 42%. FUS-GB resulted in GS upgrade significantly more often (n = 28; 51%) compared with TRUS-GB (n = 12; 22%; p < 0.001). CONCLUSIONS: (Follow-up) Mp-MRI can reliably exclude PCa progression in patients on AS. Standard serial re-biopsies might be waived if follow-up mp-MRIs are stable. Over 60% of patients with signs of tumor progression on mp-MRI during AS had a GS upgrade on re-biopsy. Targeted re-biopsies should be performed if cancer progression or higher-grade PCa is suspected on mp-MRI. KEY POINTS: • None of the patients with unsuspicious mp-MRI had a GS upgrade in re-biopsy and mp-MRI might replace serial biopsies in these cases • More than 60% of patients with mp-MRI signs of tumor progression had subsequent Gleason score (GS) upgrades • Targeted re-biopsies should be performed in case of higher GS cancer suspicion on mp-MRI.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata/diagnóstico por imagen , Espera Vigilante , Anciano , Progresión de la Enfermedad , Humanos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Valor Predictivo de las Pruebas , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/terapia , Estudios Retrospectivos , Ultrasonografía
4.
Radiologe ; 60(8): 737-746, 2020 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-32350555

RESUMEN

PURPOSE: Interdisciplinary tumor boards are periodical conferences, where optimal individual therapy plans are developed among medical experts with different specializations. The presence of a board-certified radiologist is medically indispensable in almost all relevant boards. In order to systematically evaluate the current workload for radiologists caused by these boards, we evaluated the current situation within German radiology to obtain numbers for future personnel planning. MATERIALS AND METHODS: We performed an online survey. We invited all 33 German university chairmen and 50 randomly selected head physicians of radiology at level 3 hospitals to participate. RESULTS: We had a participation rate of 79% (26/33) at university hospitals and 56% (28/50) at of level 3 non-university hospitals. The average total number of tumor boards was 3.3/day or 16.7/week at university hospitals and 2.6/day or 13/week at level 3 non-university hospitals. We calculated an average time considering preparation and execution as well as the average number of boards of 33.1 h/week for university hospitals and 18.2 h/week for level 3 hospitals. This results in a 78.8% workload for a board-certified radiologist at a university hospital (regular weekly work time 42 h) and 45.5% work load for level 3 hospitals (regular weekly work time 40 h). CONCLUSION: "Speaking radiology" as in interdisciplinary tumor boards represents a fundamental matter of course in radiology. The active participation in boards accomplished by radiologists improves evidence-based patient care. However, given the prevailing scarcity of resources in medicine, the data collected here regarding personnel costs for clinical radiology for participation in tumor boards must be taken into account in future discussions on personnel compensation.


Asunto(s)
Neoplasias/diagnóstico por imagen , Radiología/organización & administración , Alemania , Consejo Directivo/organización & administración , Humanos , Internet , Encuestas y Cuestionarios
5.
Eur Radiol ; 29(12): 6965-6970, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31250168

RESUMEN

OBJECTIVES: To evaluate different analgesic techniques in MRI-guided in-bore prostate biopsy (IB-GB) regarding the influence on patient procedural experience of pain. METHODS: Two hundred fifty-two consecutive patients who had received an IB-GB either with intrarectal instillation of 2% lidocaine gel (n = 126, group A) or with periprostatic nerve block (PPNB) with 2% mepivacaine (n = 126, group B) were retrospectively included in this study. Pain scores were measured on a visual analog scale, the operating room time (ORT) was recorded for each biopsy and correlations between the parameters were analysed. RESULTS: Pain scores for IB-GB were slightly lower in group B compared with group A (2.0 ± 1.9; 2.4 ± 1.7; p = 0.02). In group A, significantly more targeted biopsy cores were acquired (group B: 5.2 ± 1.1; group A: 5.6 ± 0.8; p < 0.01). ORT was comparable and not significantly different in both groups. There was only a weak correlation between pain scores and ORT in group B (rS = 0.22; p = 0.01), but no correlation between pain scores and the number of biopsy cores or the prostate volume. CONCLUSIONS: Pain levels are generally low for MRI-guided in-bore biopsy using either PPNB or intrarectal instillation of lidocaine gel. A statistically significant, slightly lower pain score was documented for PPNB and might be preferred when the focus is analgesia. On the other hand, due to the minor difference and easier administration, intrarectal gel instillation seems to be a reasonable practice for standard analgesia for MRI-guided in-bore biopsy. KEY POINTS: • Pain levels were low for MRI-guided in-bore biopsy using either PPNB or intrarectal instillation of lidocaine gel as analgesic method. • PPNB prior to IB-GB resulted in a slightly lower pain score but required a higher effort. • Intrarectal gel anaesthesia seems to be a reasonable practice for standard analgesia for IB-GB in an outpatient setting.


Asunto(s)
Anestésicos Locales/administración & dosificación , Lidocaína/administración & dosificación , Mepivacaína/administración & dosificación , Dolor/prevención & control , Próstata/patología , Neoplasias de la Próstata/patología , Anciano , Anciano de 80 o más Años , Analgesia/métodos , Biopsia con Aguja Gruesa/efectos adversos , Biopsia con Aguja Gruesa/métodos , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Bloqueo Nervioso/métodos , Tempo Operativo , Manejo del Dolor , Dimensión del Dolor , Estudios Retrospectivos
6.
Pneumologie ; 73(10): 573-577, 2019 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-31537020

RESUMEN

Substantial new data on early detection of lung cancer with low-dose CT has become available since the last joint statement of the German Roentgenological Society and the German Respiratory Society was published in 2011. The German S3 guideline on lung cancer was revised in 2018 and now contains a weak recommendation towards early detection of lung cancer with low-dose CT in a quality-assured early detection program. These new developments required a repositioning of the involved professional societies. This present joint statement describes main features of a quality-assured program for early detection of lung cancer with low-dose CT in Germany.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias Pulmonares/diagnóstico por imagen , Protección Radiológica/métodos , Protección Radiológica/normas , Tomografía Computarizada por Rayos X/normas , Alemania , Humanos , Guías de Práctica Clínica como Asunto , Radiografía , Sociedades Médicas
7.
Eur Radiol ; 28(1): 17-23, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28687912

RESUMEN

OBJECTIVES: To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla. METHODS: One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients´ weight, and (3) prostate volume. RESULTS: In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98). CONCLUSIONS: Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported. KEY POINTS: • Hyoscine butylbromide (HBB) improved image quality in over 2/3 of patients. • Severe artefacts were reduced after HBB in more than 20%. • The number of non-diagnostic MRI was reduced to <1% after HBB. • HBB effect was independent of bodyweight and prostate volume. • No side effects of HBB were reported in this study population.


Asunto(s)
Artefactos , Bromuro de Butilescopolamonio/administración & dosificación , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico , Anciano , Humanos , Inyecciones Intravenosas , Imagen por Resonancia Magnética/métodos , Masculino , Parasimpatolíticos/administración & dosificación , Curva ROC
8.
Clin Radiol ; 73(7): 677.e13-677.e20, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29567269

RESUMEN

AIM: To evaluate the implementation of the updated computed tomography (CT) diagnostic reference levels (DRLs) from the German Federal Office for Radiation Protection into clinical routine using an automatic CT dose monitoring system. METHODS AND MATERIALS: CT radiation exposure was analysed before and after implementing the updated national DRLs into routine clinical work in 2016. After the implementation process, institutional CT protocols were mapped to the anatomical regions for which DRLs were provided. Systematically, protocols that exceeded the thresholds were optimised and analysed in detail. The CT radiation output parameters analysed were volumetric CT dose index (CTDIvol) and dose-length product (DLP). Three radiologists evaluated subjective image quality using a three-point Likert scale. RESULTS: The study included 94,258 CT series (from 27,103 CT examinations) in adult patients performed in 2016. When averaged over all body regions with available DRL, institutional CTDIvol/DLP values were always below the DRLs (65.2±32.9%/67.3±41.5% initially; 59.4±32%/60.5±39.9% after optimisation). Values exceeding the national DRLs were found for pelvis (n=268; CTDIvol 107.7±65.7%/DLP 106.3±79.3%), lumbar spine (n=91; 160.8±74.7%/175.2±104.1%), and facial bones (n=527; 108±39%/152.7±75.7%). After optimisation, CTDIvol and DLP were 87.9±73%/87.8±80.8% for the pelvis, 67.8±33.2%/74.5±50.6% for the lumbar spine and 95.1±45.8%/133.3±74.6% for the viscerocranium. CONCLUSION: An automatic CT dose monitoring system enabled not only comprehensive monitoring of a DRL implementation process but can also help to optimise radiation exposure.


Asunto(s)
Garantía de la Calidad de Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/estadística & datos numéricos , Dosis de Radiación , Exposición a la Radiación/normas , Tomografía Computarizada por Rayos X/normas , Adulto , Humanos , Exposición a la Radiación/estadística & datos numéricos , Valores de Referencia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
9.
Clin Radiol ; 72(5): 428.e7-428.e12, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28065638

RESUMEN

AIM: To investigate the value of dedicated computed tomography (CT) iterative metal artefact reduction (iMAR) algorithms in patients after spinal instrumentation. MATERIALS AND METHODS: Post-surgical spinal CT images of 24 patients performed between March 2015 and July 2016 were retrospectively included. Images were reconstructed with standard weighted filtered back projection (WFBP) and with two dedicated iMAR algorithms (iMAR-Algo1, adjusted to spinal instrumentations and iMAR-Algo2, adjusted to large metallic hip implants) using a medium smooth kernel (B30f) and a sharp kernel (B70f). Frequencies of density changes were quantified to assess objective image quality. Image quality was rated subjectively by evaluating the visibility of critical anatomical structures including the central canal, the spinal cord, neural foramina, and vertebral bone. RESULTS: Both iMAR algorithms significantly reduced artefacts from metal compared with WFBP (p<0.0001). Results of subjective image analysis showed that both iMAR algorithms led to an improvement in visualisation of soft-tissue structures (median iMAR-Algo1=3; interquartile range [IQR]:1.5-3; iMAR-Algo2=4; IQR: 3.5-4) and bone structures (iMAR-Algo1=3; IQR:3-4; iMAR-Algo2=4; IQR:4-5) compared to WFBP (soft tissue: median 2; IQR: 0.5-2 and bone structures: median 2; IQR: 1-3; p<0.0001). Compared with iMAR-Algo1, objective artefact reduction and subjective visualisation of soft-tissue and bone structures were improved with iMAR-Algo2 (p<0.0001). CONCLUSION: Both iMAR algorithms reduced artefacts compared with WFBP, however, the iMAR algorithm with dedicated settings for large metallic implants was superior to the algorithm specifically adjusted to spinal implants.


Asunto(s)
Algoritmos , Artefactos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
10.
Osteoarthritis Cartilage ; 24(10): 1761-1768, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27163444

RESUMEN

OBJECTIVE: To assess the glycosaminoglycan (GAG) content of lumbar intervertebral discs (IVD) in healthy volunteers with facet tropism (FT) and sagittal facet joint (FJ) orientation using glycosaminoglycan chemical exchange saturation transfer imaging (gagCEST). METHOD: Seventy-five lumbar IVDs of twenty-five young, healthy volunteers without any history of lumbar spine pathologies (13 female; 12 male; mean age: 28.0 ± 4.4 years; range: 21-35 years) were examined with a 3T MRI scanner. Orientation of FT and FJ were assessed for L3/4, L4/5 and L5/S1 using standard T2 weighted images. Biochemical gagCEST imaging was used to determine the GAG content of each nucleus pulposus (NP) and annulus fibrosus (AF). RESULTS: Significantly higher gagCEST values of NP were found in volunteers without FT and normal FJ orientation compared to volunteers with FT and sagittal FJ orientation >45° (P < 0.0001). GagCEST values were significantly higher in volunteers without FT compared to volunteers with moderate or severe FT (moderate FT: P < 0.0001; severe FT: P = 0.0033). Volunteers with normal FJ orientation showed significantly higher gagCEST values compared to those with sagittal FJ orientation >45° (P < 0.001). We found a significant, negative correlation between gagCEST values and higher angels in sagittal FJ orientation (rho = -0.459; P < 0.0001). CONCLUSION: GagCEST analysis indicated lower GAG values of NP in young volunteers with FT and sagittal orientated FJ, indicating that FT and sagittal orientation of the FJ represent risk factors for the development of early biochemical alterations of lumbar IVDs.


Asunto(s)
Articulación Cigapofisaria , Adulto , Femenino , Humanos , Disco Intervertebral , Vértebras Lumbares , Imagen por Resonancia Magnética , Masculino , Factores de Riesgo , Tropismo , Adulto Joven
11.
Eur Radiol ; 26(11): 3858-3864, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26920391

RESUMEN

PURPOSE: This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. METHODS: Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. RESULTS: For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). CONCLUSION: The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. KEY POINTS: • Higher PI-RADS overall score (IV-V) correlated well with PCa detection rate • In more than 80 % SBC was concordant regarding overall PCa detection • In almost 90 % there was no Gleason upgrading by the SBC • Only 2/54 (3.7 %) csPCa was missed when the SBC was omitted • For IB-GB a further reduction of biopsy cores is reasonable.


Asunto(s)
Biopsia con Aguja Gruesa/métodos , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico , Anciano , Humanos , Masculino , Clasificación del Tumor , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
Clin Radiol ; 70(2): 176-82, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25496824

RESUMEN

AIM: To perform a systematic, large-scale analysis using the Digital Imaging and Communication in Medicine structured report (DICOM-SR) to assess the relationship between body mass index (BMI) and radiation exposure in abdominal CT. MATERIALS AND METHODS: A retrospective analysis of DICOM-SR of 3121 abdominal CT examinations between April 2013 and March 2014 was performed. All examinations were conducted using a 128 row CT system. Patients (mean age 61 ± 15 years) were divided into five groups according to their BMI: group A <20 kg/m(2) (underweight), group B 20-25 kg/m(2) (normal weight), group C 25-30 kg/m(2) (overweight), group D 30-35 kg/m(2) (obese), and group E > 35 kg/m(2) (extremely obese). CT dose index (CTDIvol) and dose-length product (DLP) were compared between all groups and matched to national diagnostic reference values. RESULTS: The mean CTDIvol and DLP were 5.4 ± 2.9 mGy and 243 ± 153 mGy.cm in group A, 6 ± 3.6 mGy and 264 ± 179 mGy.cm in group B, 7 ± 3.6 mGy and 320 ± 180 mGy.cm in group C, 8.1 ± 5.2 mGy and 375 ± 306 mGy.cm in group D, and 10 ± 8 mGy and 476 ± 403 mGy.cm in group E, respectively. Except for group A versus group B, CTDIvol and DLP differed significantly between all groups (p<0.05). Significantly more CTDIvol values exceeded national diagnostic reference values in groups D and E (2.1% and 6.3%) compared to group B (0.5%, p<0.05). CONCLUSION: DICOM-SR is a comprehensive, fast, and reproducible way to analyse dose-related data at CT. It allows for automated evaluation of radiation dose in a large study population. Dose exposition is related to the patient's BMI and is increased by up to 96% for extremely obese patients undergoing abdominal CT.


Asunto(s)
Índice de Masa Corporal , Dosis de Radiación , Monitoreo de Radiación/estadística & datos numéricos , Radiografía Abdominal/métodos , Sistemas de Información Radiológica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/diagnóstico por imagen , Obesidad Mórbida/diagnóstico por imagen , Estudios Retrospectivos
13.
Skeletal Radiol ; 44(4): 513-8, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25367672

RESUMEN

OBJECTIVE: To intra-individually assess the association of inflammation severity and cartilage composition measured by RAMRIS synovitis sub-score and delayed gadolinium-enhanced magnetic resonance imaging of the cartilage (dGEMRIC) of metacarpophalangeal (MCP) joints in patients with rheumatoid arthritis (RA). METHODS: Forty-three patients with RA according to ACR/EULAR classification criteria (age 52.9 ± 14.5 years, range, 18-77 years) were included in this study. All study participants received 3-T MRI scans of the metacarpophalangeal joints of the second and third finger (MCP 2 and 3). The severity of synovitis was scored according to the RAMRIS synovitis sub-score by two readers in consensus. In the cases with identical synovitis sub-scores, two radiologists decided in consensus on the joint with more severe synovitis. Cartilage composition was assessed with dGEMRIC. To test the association of inflammation severity and cartilage damage and in order to eliminate inter-patient confounders, each patient's MCP 2 and 3 were dichotomized into the joint with more severe synovitis versus the joint with less severe synovitis for a paired Wilcoxon test of dGEMRIC value. RESULTS: There was a significant difference of dGEMRIC value (median of difference: 47.12, CI [16.6; 62.76]) between the dichotomized MCPs (p = 0.0001). There was a significant correlation between dGEMRIC value and RAMRIS synovitis grading of the joint with more severe synovitis (r = 0.5; p < 0.05) and the joint with less severe synovitis (r = 0.33; p < 0.05). CONCLUSIONS: Our data concur with the concept that synovitis severity is associated with cartilage damage. The local inflammatory status on a joint level correlated significantly with the extent of cartilage degradation in biochemical MRI.


Asunto(s)
Artritis Reumatoide/patología , Cartílago/patología , Articulaciones de los Dedos/patología , Inflamación/patología , Imagen por Resonancia Magnética , Adolescente , Adulto , Anciano , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Adulto Joven
14.
Z Gastroenterol ; 53(1): 28-32, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25594704

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate potential causes of Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. MATERIAL AND METHODS: We retrospectively evaluated 26 patients who required TIPS revision (group I) and 24 patients who did not require any further intervention (group II) within the first two years following TIPS implantation. The distance of the distal end of the stent to the hepatocaval junction was measured. Furthermore, the angle between the stent and the portal vein (inflow) and the angle between the stent and the hepatic vein (outflow) were measured. Furthermore, the following data were evaluated: pre- and postinterventional portal pressure gradients, maximal postinterventional flow and blood values [C-reactive protein (CRP), bilirubin, glutamic-oxaloacetic transaminase (GOT), glutamic-pyruvic transaminase (GPT)]. RESULTS: Compared with control subjects, patients who required TIPS revision showed a significantly longer distance from the distal end of the stent to the hepatocaval junction (I: 17.3 ±â€Š10 mm, II: 6.7 ±â€Š5.7 mm, p < 0.001). There was a statistically significant correlation between the above named distance and the time to revision (Pearson's correlation coefficient, r = 0.5, p = 0.01). In addition, patients with TIPS revision had a significantly larger angle of portalvenous inflow (alpha angle) than the control group (I: 100.5 ±â€Š31.5°, II: 64.5 ±â€Š31.6°, p < 0.001). CONCLUSION: Our results show that the distance from the end of the stent to the hepatocaval junction and the angle of portalvenous inflow are technical factors that may influence the shunt's patency rate. Of these two, the distance to the hepatocaval junction can be influenced easily by the interventionalist.


Asunto(s)
Supervivencia de Injerto/fisiología , Venas Hepáticas/fisiología , Circulación Hepática/fisiología , Derivación Portosistémica Intrahepática Transyugular , Stents , Grado de Desobstrucción Vascular/fisiología , Velocidad del Flujo Sanguíneo , Análisis de Falla de Equipo , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
15.
Eur Radiol ; 24(2): 527-30, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24154793

RESUMEN

OBJECTIVE: To evaluate the prognostic value of hyperattenuating adrenal glands on contrast-enhanced CT of polytraumatised patients. METHODS: Two hundred ninety-two patients (195 men and 97 women, mean age 45.3 ± 23.3 years) were included in this retrospective study. CT examinations were performed 60 s after intravenous injection of contrast material. Image analysis was performed by two radiologists. Patients were assigned to one of two groups according to the attenuation of the adrenal gland [group 1: adrenal glands ≥ inferior vena cava (IVC); group 2: adrenal glands < IVC]. RESULTS: Eighteen patients (42.2 years ± 24.2) were assigned to group 1 and 274 patients (48.4 years ± 22.4) to group 2. The average adrenal density was 150.8 ± 36.1 HU in group 1 and 83.7 ± 23.6 HU in group 2 (P < 0.0001). Eight of the 18 patients in group 1 (44.4%) and 33 of the 274 patients in group 2 (12.4%) died during hospitalisation (P < 0.05). Mean adrenal enhancement was significantly higher in patients who died (101.9 ± 40.6 HU) compared with survivors (86.1 ± 27.0 HU; P < 0.001). CONCLUSION: Hyperattenuation of adrenal glands is associated with a higher mortality rate in polytraumatised patients and may serve as a predictor of poor clinical outcome. KEY POINTS: • Hyperattenuating adrenal glands can be observed in 6.2% of polytraumatised patients. • Hyperattenuating adrenal glands indicate poor clinical outcome in polytraumatised patients. • In polytraumatised patients, hyperattenuating adrenal glands are associated with a high mortality rate. • Adrenal enhancement is higher amongst patients who died than amongst survivors.


Asunto(s)
Glándulas Suprarrenales/diagnóstico por imagen , Medios de Contraste , Traumatismo Múltiple/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Niño , Preescolar , Medios de Contraste/administración & dosificación , Femenino , Estudios de Seguimiento , Alemania/epidemiología , Humanos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Traumatismo Múltiple/mortalidad , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tasa de Supervivencia/tendencias
16.
Clin Radiol ; 69(7): 721-6, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24836523

RESUMEN

AIM: To evaluate the influence of attenuation-based tube potential selection (ATPS) in combination with organ-specific dose reduction (OSDR) on radiation dose and image quality of contrast-enhanced chest computed tomography (CT) examinations. MATERIAL AND METHODS: Seventy consecutive patients (59.2 ± 16.1 years; 49 men; 21 women) were randomized into two groups and underwent contrast-enhanced chest CT using a 128 section CT scanner. CT examinations were performed as standard protocol in group A (n = 35) and with the activated novel dose-saving devices, OSDR and ATPS, in group B (n = 35). Objective [signal-to-noise (SNR) and contrast-to-noise ratio (CNR)] and subjective image quality (five-point scale; 1 = non diagnostic; 5 = excellent) as well as radiation dose (CTDIvol) were analysed. RESULTS: CTDIvol of the protocol using OSDR and ATPS was significantly lower than in standard chest CT examinations (3.4 ± 1 versus 6.1 ± 2.3 mGy; p < 0.001). Although the level of noise was slightly elevated in group B (14.1 ± 1.7 versus 11.4 ± 1.9 HU; p < 0.01), no significant differences in SNR (17.1 ± 5 versus 16.3 ± 4.7) or subjective image quality (mean score of 4.6 versus 4.4) were observed between both imaging protocols. CONCLUSION: Attenuation-based tube potential selection in combination with organ-specific dose reduction essentially reduces the dose of chest CT in patients with normal body mass index (BMI) in clinical routine while maintaining subjective and objective image quality.


Asunto(s)
Neumonía/diagnóstico por imagen , Dosis de Radiación , Anciano , Algoritmos , Medios de Contraste , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Protección Radiológica , Relación Señal-Ruido , Tórax/efectos de la radiación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
17.
Radiologe ; 54(4): 359-62, 2014 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-24549740

RESUMEN

(DICOM E-MAIL provides a standardized way for exchanging DICOM objects (Digital Imaging and Communications in Medicine) and further relevant patient data for the treatment context reliably and securely via encrypted e-mails. The current version of the DICOM E-MAIL standard recommendations of the"Deutsche Röntgengesellschaft" (DRG, German Röntgen Society) defines for the first time options for setting up a special directory service for the provision and distribution of communication data of all participants in a network. By using such"telephone books", networks of any size can be operated independent of the provider. Compared to a Cross-Enterprise Document Sharing (XDS) scenario, the required infrastructure is considerably less complex and quicker to realize. Critical success factors are, in addition to the technology and an effective support, that the participants themselves contribute to the further development of the network and in this way, the network approach can be practiced.


Asunto(s)
Redes Comunitarias/organización & administración , Correo Electrónico/organización & administración , Sistemas de Información Radiológica/organización & administración , Derivación y Consulta/organización & administración , Telerradiología/organización & administración , Alemania , Difusión de la Información/métodos
18.
Abdom Radiol (NY) ; 49(1): 192-201, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37906272

RESUMEN

OBJECTIVES: To analyze multiparametric MRI (mpMRI) characteristics of patients with International Society of Urological Pathology (ISUP) grade group (GG) 4 or 5 prostate cancer (PC) and to correlate MRI parameters with the occurrence of biochemical recurrence (BCR) after radical prostatectomy (RPE). METHODS: In this single-center cohort study consecutive patients with mpMRI and ISUP GG 4 or 5 PC were retrospectively analyzed. Clinical, MR-guided biopsy, and diagnostic mpMRI parameter were assessed. A subcohort of patients with RPE and follow-up was analyzed separately. A univariate and multivariate analyses were performed to determine parameters that are associated to patients with BCR after RPE. RESULTS: 145 patients (mean age 70y, median PSA 10.9 ng/ml) were analyzed. 99% had a PI-RADS classification of 4 or 5, 48% revealed MRI T3 stage, and median diameter of the MRI index lesion (IL) was 15 mm. IL showed a median ADC value of 668 ×10-6 mm2/s and exhibited contrast enhancement in 94% of the cases. For patients with follow-up after RPE (n = 82; mean follow-up time 68 ± 27 m), MRI parameters were significantly different for contact length of the IL to the pseudocapsule (LCC), MRI T3 stage, and IL localization (p < 0.05). Higher PSAD and MRI T3 stage were independent parameters for the risk of BCR when incorporating clinical, biopsy, and MRI parameters. CONCLUSION: ISUP GG 4 or 5 PC has distinctive characteristics on mpMRI and were detected on MRI in all cases. In addition, higher PSAD and MRI T3 stage were significant predictors for BCR after RPE.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Anciano , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Imagen por Resonancia Magnética , Estudios Retrospectivos , Estudios de Seguimiento , Estudios de Cohortes , Antígeno Prostático Específico , Biopsia Guiada por Imagen
19.
Eur J Radiol ; 175: 111436, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38522396

RESUMEN

PURPOSE: Patients with suspicion of clinically significant prostate cancer (csPC) on multiparametric prostate MRI (mpMRI) but negative or inconclusive MRI/US fusion-guided biopsy (FB) can be challenging in clinical practice. To assess the utility of MRI in-bore biopsy (IB) in patients with discordant imaging and histopathological findings after FB. METHODS: Consecutive patients with Prostate Imaging Reporting and Data System (PI-RADS) category 4 or 5 on mpMRI at 3T after FB without histologically confirmed csPC who underwent IB between 01/2014 and 05/2022, were retrospectively included. The primary objective was to assess the detection rate of csPC. Secondary objectives were to analyze clinical parameters, MRI parameters, and lesion localization. RESULTS: In the final cohort of 51 patients, the IB resulted in an overall detection rate of 71% for PC and 47% for csPC. Furthermore, in 55% of cases with initial low-grade PC, the Gleason score was upgraded after IB. CsPC was often detected apical and/or anterior. The detection rate for PC was 58% in PI-RADS category 4 and 94% in PI-RADS category 5 (csPC 39% and 61%, respectively). Patients with csPC had statistically significant smaller prostate volumes, a higher PI-RADS category, a higher prostate-specific antigen density (PSAD), and were older. CONCLUSIONS: For a relevant proportion of patients with PI-RADS category 4 or 5 and negative or inconclusive findings on previous FB, but with persistent suspicion of csPC, a subsequent IB verified the presence of csPC. Therefore, IB can be a backup in cases of uncertainty.


Asunto(s)
Biopsia Guiada por Imagen , Neoplasias de la Próstata , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Biopsia Guiada por Imagen/métodos , Anciano , Persona de Mediana Edad , Estudios Retrospectivos , Ultrasonografía Intervencional , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Reproducibilidad de los Resultados
20.
Eur Radiol ; 23(6): 1503-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23300039

RESUMEN

OBJECTIVES: Organ-specific dose reduction (OSDR) algorithms can reduce radiation on radiosensitive organs up to 59 %. This study evaluates the influence of a new OSDR algorithm on image quality of head and neck computed tomographic angiography (CTA) in clinical routine. METHODS: Sixty-two consecutive patients (68 ± 13 years) were randomised into two groups and imaged using 128-row multidetector CT. Group A (n = 31) underwent conventional CTA and group B (n = 31) CTA with a novel OSDR algorithm. Subjective and objective image quality were statistically compared. Subjective image quality was rated on a five-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated with region-of-interest measurements. RESULTS: The SNR of the common carotid artery and middle cerebral artery was 53.6 ± 22.7 and 43.3 ± 15.3 (group A) versus 54.1 ± 20.5 and 46.2 ± 14.6 (group B). The CNR was 40.0 ± 19.3 and 29.7 ± 12.0 (group A) compared with 40.7 ± 16.8 and 32.9 ± 10.9 (group B), respectively. Subjective image quality was excellent in both groups (mean score 4.4 ± 0.7 versus 4.4 ± 0.6). Differences between the two groups were not significant. CONCLUSIONS: The novel OSDR algorithm does not compromise image quality of head and neck CTA. Its application can be recommended for CTA in clinical routine to protect the thyroid gland and ocular lenses from unnecessary high radiation. KEY POINTS: • Organ-specific dose reduction (OSDR) can significantly reduce radiation exposure during CT • OSDR does not compromise image quality of head and neck CTA • OSDR can significantly lower the risk of radiation damage to sensitive organs • OSDR can easily be applied in routine clinical practice.


Asunto(s)
Angiografía Cerebral/métodos , Neoplasias de Cabeza y Cuello/diagnóstico , Neoplasias de Cabeza y Cuello/patología , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Arteria Carótida Común/patología , Medios de Contraste/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/patología , Estudios Prospectivos , Reproducibilidad de los Resultados , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA