Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Phys Rev Lett ; 132(2): 024001, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38277580

RESUMEN

The classical Richtmyer-Meshkov instability (RMI) is a hydrodynamic instability characterizing the evolution of an interface following shock loading. In contrast to other hydrodynamic instabilities such as Rayleigh-Taylor, it is known for being unconditionally unstable: regardless of the direction of shock passage, any deviations from a flat interface will be amplified. In this article, we show that for negative Atwood numbers, there exist special sequences of shocks which result in a nearly perfectly suppressed instability growth. We demonstrate this principle computationally and experimentally with stepped fliers and phase transition materials. A fascinating immediate corollary is that in specific instances, a phase-transitioning material may self-suppress RMI.

2.
Microsc Microanal ; 15(4): 272-81, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19575828

RESUMEN

Extrapolating from a brief survey of the literature, we outline a vision for the future development of time-resolved electron probe instruments that could offer levels of performance and flexibility that push the limits of physical possibility. This includes a discussion of the electron beam parameters (brightness and emittance) that limit performance, the identification of a dimensionless invariant figure of merit for pulsed electron guns (the number of electrons per lateral coherence area, per pulse), and calculations of how this figure of merit determines the trade-off of spatial against temporal resolution for different imaging modes. Modern photonics' ability to control its fundamental particles at the quantum level, while enjoying extreme flexibility and a very large variety of operating modes, is held up as an example and a goal. We argue that this goal may be approached by combining ideas already in the literature, suggesting the need for large-scale collaborative development of next-generation time-resolved instruments.


Asunto(s)
Microscopía Electrónica/métodos , Microscopía Electrónica/tendencias
3.
Genetics ; 154(1): 181-92, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10628979

RESUMEN

The mitochondrial genome (mtDNA) of the plant parasitic nematode Globodera pallida exists as a population of small, circular DNAs that, taken individually, are of insufficient length to encode the typical metazoan mitochondrial gene complement. As far as we are aware, this unusual structural organization is unique among higher metazoans, although interesting comparisons can be made with the multipartite mitochondrial genome organizations of plants and fungi. The variation in frequency between populations displayed by some components of the mtDNA is likely to have major implications for the way in which mtDNA can be used in population and evolutionary genetic studies of G. pallida.


Asunto(s)
ADN Mitocondrial/genética , Nematodos/genética , Solanum tuberosum/parasitología , Animales , Secuencia de Bases , Clonación Molecular , Cartilla de ADN , ADN Mitocondrial/ultraestructura , Microscopía Electrónica , Hibridación de Ácido Nucleico , Reacción en Cadena de la Polimerasa , Mapeo Restrictivo
4.
Neurology ; 45(10): 1808-14, 1995 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-7477973

RESUMEN

MRI is a sensitive technique for assessing disease activity in MS. Diseased white matter (WM) can be identified on T2-weighted images, and active disease is reflected by abnormalities in the blood-brain barrier (BBB) shown on T1-weighted images after administration of paramagnetic contrast agents. Active disease may be demonstrated by contrast-enhanced MRI in patients with early, mild relapsing-remitting (RR) MS even during periods of clinical stability, which indicates that MS is an active process even during the early phase of the illness. To examine the amount of abnormal WM at frequent intervals over time, we studied seven mildly affected RRMS patients, all of whom had frequent contrast-enhancing lesions. These RRMS patients were imaged monthly for 26 to 36 months at 1.5 tesla; the area of abnormal increased WM signal was calculated by image-processing software that utilizes both the T2- and T1-weighted images. All patients showed fluctuations over time in amount of abnormal WM signal, which reflected factors such as the amount of BBB breakdown (measured by number or area of enhancing lesions) and measurement error. All seven RRMS patients, however, showed an overall increase in abnormal WM. Because of the fluctuations between individual measurements, the increase was most accurately reflected when the mean of the first 6 months' measurements was compared with the mean of the final 6 months' measurements, or when a linear regression model was applied.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Encéfalo/patología , Esclerosis Múltiple/patología , Adulto , Medios de Contraste , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Esclerosis Múltiple/fisiopatología , Recurrencia , Factores de Tiempo
5.
Invest Radiol ; 36(2): 65-71, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11224753

RESUMEN

RATIONALE AND OBJECTIVES: The safety and diagnostic efficacy of MultiHance (gadobenate dimeglumine) in the central nervous system (CNS) were evaluated in a double-blind, multicenter, phase III clinical trial. METHODS: Two hundred five patients highly suspected of having a CNS lesion (by previous imaging exam) were enrolled at 16 sites in the United States. Patients were randomized to one of three incremental dosing regimens. Magnetic resonance imaging with Omniscan (gadodiamide) at doses of 0.1 and 0.3 mmol/kg was compared with MultiHance (gadobenate dimeglumine) at doses of 0.05 and 0.15 mmol/kg and at 0.1 and 0.2 mmol/kg. RESULTS: Compared with predose images alone, efficacy was demonstrated in each of the gadobenate dimeglumine and gadodiamide groups (single and cumulative doses) as indicated by the level of diagnostic information, number of lesions detected, and contrast-to-noise ratio measurements. The level of diagnostic information from gadobenate dimeglumine at 0.1 mmol/kg was equivalent to that with gadodiamide at the same dose. One of the two blinded reviewers found equivalence between the gadobenate dimeglumine 0.05 mmol/kg dose and gadodiamide at 0.1 mmol/kg. Both reviewers found the level of diagnostic information to be equivalent after the second dose of contrast for all three dosing regimens. The cumulative doses of gadobenate dimeglumine were well tolerated and as safe as gadodiamide. CONCLUSIONS: Gadobenate dimeglumine is comparable to gadodiamide in terms of safety and efficacy for imaging of CNS lesions, with a possible advantage in imaging applications owing to enhanced T1 relaxivity.


Asunto(s)
Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Medios de Contraste/administración & dosificación , Gadolinio DTPA , Imagen por Resonancia Magnética , Meglumina , Compuestos Organometálicos , Medios de Contraste/efectos adversos , Método Doble Ciego , Femenino , Gadolinio/administración & dosificación , Gadolinio/efectos adversos , Gadolinio DTPA/administración & dosificación , Gadolinio DTPA/efectos adversos , Humanos , Masculino , Meglumina/administración & dosificación , Meglumina/efectos adversos , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Compuestos Organometálicos/efectos adversos
6.
Lasers Surg Med ; 39(3): 273-85, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17311312

RESUMEN

BACKGROUND AND OBJECTIVE: Few studies have investigated femtosecond (fs) lasers for cutting bone tissue. STUDY DESIGN/MATERIALS AND METHODS: A 775 nm, 1 kHz, 200 femtosecond, up to 400 microJ laser system was used to irradiate in vitro calcified cortical bone samples and bone tissue culture samples. RESULTS: The ablation threshold in cortical bone was 0.69+/-0.08 J/cm(2) at 775 nm and 0.19+/-0.05 J/cm(2) at 387 nm. Plasma shielding experiments determined that the ablation plume and the plasma significantly affect material removal at high repetition rates and appear to generate thermal transients in calcified tissue. Confocal analysis revealed intact enzymatic activity on the surface of cells immediately adjacent to cells removed by fs laser irradiation. CONCLUSIONS: These experiments demonstrate that fs lasers used for bone tissue cutting do not appear to generate significant temperature transients to inactivate proteins and that cellular membrane integrity is disrupted for only a few cell layers.


Asunto(s)
Terapia por Láser/métodos , Cráneo/cirugía , Fosfatasa Alcalina/metabolismo , Supervivencia Celular , Humanos , Recién Nacido , Terapia por Láser/instrumentación , Microscopía Electrónica de Rastreo , Cráneo/metabolismo , Cráneo/patología , Coloración y Etiquetado
7.
Opt Lett ; 24(19): 1343-5, 1999 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-18079798

RESUMEN

A new concept is introduced whereby thermal stresses generated through the pumping process are canceled by an applied force. By use of a Nd:YVO(4) disk laser as a model system, significant reduction of thermal lensing and deformation is demonstrated as a function of applied pressure, and the output power (19 W TEM(00)) is limited only by the available pump power.

8.
Opt Lett ; 26(15): 1152-4, 2001 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-18049546

RESUMEN

We have compressed the output from a beta-barium borate noncollinear optical parametric amplifier to ~7-fs pulse durations, using a micromachined deformable mirror with an efficient search algorithm. This compression method allows phase compensation of both material and gain dispersion, which produces an optimized wavelength-tunable pulse shape for ultrahigh-resolution time-domain spectroscopy.

9.
J Comput Assist Tomogr ; 15(5): 832-4, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1885805

RESUMEN

We present a case of a patient with apoplexy due to infarction of a large pituitary macroadenoma. Conservative treatment with steroids resulted in reversal of symptoms and the adenoma involuted. This suggests that medical management may be sufficient therapy in some patients with this complication.


Asunto(s)
Adenoma/complicaciones , Imagen por Resonancia Magnética , Regresión Neoplásica Espontánea , Apoplejia Hipofisaria/etiología , Neoplasias Hipofisarias/complicaciones , Tomografía Computarizada por Rayos X , Adenoma/diagnóstico , Adenoma/tratamiento farmacológico , Anciano , Dexametasona/uso terapéutico , Humanos , Masculino , Apoplejia Hipofisaria/tratamiento farmacológico , Neoplasias Hipofisarias/diagnóstico , Neoplasias Hipofisarias/tratamiento farmacológico
10.
Proc Natl Acad Sci U S A ; 100(9): 4990-4, 2003 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-12697894

RESUMEN

Model studies of the ligand photodissociation process of carboxymyoglobin have been conducted by using amplified few-cycle laser pulses short enough in duration (<10 fs) to capture the phase of the induced nuclear motions. The reaction-driven modes are observed directly in real time and depict the pathway by which energy liberated in the localized reaction site is efficiently channeled to functionally relevant mesoscale motions of the protein.


Asunto(s)
Grupo Citocromo c/química , Mioglobina/química , Animales , Monóxido de Carbono , Rayos Láser
11.
J Comput Assist Tomogr ; 17(2): 191-9, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8454744

RESUMEN

A method for determining the concentrations of the materials that produce the well-resolved singlet signals in short TE brain 1H MR spectroscopic examinations is presented. Concentration determination is achieved by a water-referencing procedure. The ratios of the areas of the choline, total creatine, and N-acetyl signals to that of the water signal from the same volume of interest (VOI) are determined using acquisitions with and without water suppression. The tissue concentrations of the molecules producing the three signals can then be determined if the water concentration in the VOI can be found. This is done with a density-weighted MR study. The MR study provides the ratio of the mean MR signal amplitude from the VOI to that from an external standard containing a known water concentration. The method's flexibility is illustrated by using it with two different single-volume localization schemes and spectroscopic imaging. Preliminary evaluations of accuracy and reproducibility are made in phantom, animal, and limited human studies. The method's advantages and limitations are discussed.


Asunto(s)
Encéfalo/metabolismo , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Acetilación , Animales , Agua Corporal/química , Agua Corporal/metabolismo , Encéfalo/anatomía & histología , Química Encefálica , Gatos , Colina/análisis , Colina/metabolismo , Creatina/análisis , Creatina/metabolismo , Humanos , Hidrógeno , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Modelos Biológicos , Modelos Estructurales , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA