Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Gut ; 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39349006

RESUMEN

BACKGROUND AND AIMS: The efficacy of colorectal endoscopic mucosal resection (EMR) is limited by recurrence and the necessity for conservative surveillance. Margin thermal ablation (MTA) after EMR has reduced the incidence of recurrence at the first surveillance colonoscopy at 6 months (SC1). Whether this effect is durable to second surveillance colonoscopy (SC2) is unknown. We evaluated long-term surveillance outcomes in a cohort of LNPCPs that have undergone MTA. METHODS: LNPCPs undergoing EMR and MTA from four academic endoscopy centres were prospectively recruited. EMR scars were evaluated at SC1 and in the absence of recurrence, SC2 colonoscopy was conducted in a further 12 months. A historical control arm was generated from LNPCPs that underwent EMR without MTA. The primary outcome was recurrence at SC2 in all LNPCPs with a recurrence-free scar at SC1. RESULTS: 1152 LNPCPs underwent EMR with complete MTA over 90 months until October 2022. 854 LNPCPs underwent SC1 with 29/854 (3.4%) LNPCPs demonstrating recurrence. 472 LNPCPs free of recurrence at SC1 underwent SC2. 260 LNPCPs with complete SC2 follow-up formed the control arm from January 2012 to May 2016. Recurrence at SC2 was significantly less in the MTA arm versus controls (1/472 (0.2%) vs 9/260 (3.5%); p<0.001)). CONCLUSION: LNPCPs that have undergone successful EMR with MTA and are free of recurrence at SC1 are unlikely to develop recurrence in subsequent surveillance out to 2 years. Provided the colon is cleared of synchronous neoplasia, the next surveillance can be potentially extended to 3-5 years. Such an approach would reduce costs and enhance patient compliance.

2.
Gastroenterology ; 163(1): 295-304.e5, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35304117

RESUMEN

BACKGROUND & AIMS: Artificial intelligence (AI) may detect colorectal polyps that have been missed due to perceptual pitfalls. By reducing such miss rate, AI may increase the detection of colorectal neoplasia leading to a higher degree of colorectal cancer (CRC) prevention. METHODS: Patients undergoing CRC screening or surveillance were enrolled in 8 centers (Italy, UK, US), and randomized (1:1) to undergo 2 same-day, back-to-back colonoscopies with or without AI (deep learning computer aided diagnosis endoscopy) in 2 different arms, namely AI followed by colonoscopy without AI or vice-versa. Adenoma miss rate (AMR) was calculated as the number of histologically verified lesions detected at second colonoscopy divided by the total number of lesions detected at first and second colonoscopy. Mean number of lesions detected in the second colonoscopy and proportion of false negative subjects (no lesion at first colonoscopy and at least 1 at second) were calculated. Odds ratios (ORs) and 95% confidence intervals (CIs) were adjusted by endoscopist, age, sex, and indication for colonoscopy. Adverse events were also measured. RESULTS: A total of 230 subjects (116 AI first, 114 standard colonoscopy first) were included in the study analysis. AMR was 15.5% (38 of 246) and 32.4% (80 of 247) in the arm with AI and non-AI colonoscopy first, respectively (adjusted OR, 0.38; 95% CI, 0.23-0.62). In detail, AMR was lower for AI first for the ≤5 mm (15.9% vs 35.8%; OR, 0.34; 95% CI, 0.21-0.55) and nonpolypoid lesions (16.8% vs 45.8%; OR, 0.24; 95% CI, 0.13-0.43), and it was lower both in the proximal (18.3% vs 32.5%; OR, 0.46; 95% CI, 0.26-0.78) and distal colon (10.8% vs 32.1%; OR, 0.25; 95% CI, 0.11-0.57). Mean number of adenomas at second colonoscopy was lower in the AI-first group as compared with non-AI colonoscopy first (0.33 ± 0.63 vs 0.70 ± 0.97, P < .001). False negative rates were 6.8% (3 of 44 patients) and 29.6% (13 of 44) in the AI and non-AI first arms, respectively (OR, 0.17; 95% CI, 0.05-0.67). No difference in the rate of adverse events was found between the 2 groups. CONCLUSIONS: AI resulted in an approximately 2-fold reduction in miss rate of colorectal neoplasia, supporting AI-benefit in reducing perceptual errors for small and subtle lesions at standard colonoscopy. CLINICALTRIALS: gov, Number: NCT03954548.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Adenoma/diagnóstico por imagen , Adenoma/patología , Inteligencia Artificial , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/epidemiología , Detección Precoz del Cáncer/métodos , Humanos
3.
Endoscopy ; 55(10): 898-906, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37230471

RESUMEN

BACKGROUND: This study aimed to determine long-term outcomes of gastric endoscopic submucosal dissection (ESD) in Western settings based on the latest Japanese indication criteria, and to examine predictors of outcomes and complications. METHODS: Data were collected from consecutive patients undergoing gastric ESD at four participating centers from 2009 to 2021. Retrospective analysis using logistic regression and survival analysis was performed. RESULTS: 415 patients were included (mean age 71.7 years; 56.4 % male). Absolute indication criteria (2018 guideline) were met in 75.3 % of patients. Median follow-up was 52 months. Post-resection histology was adenocarcinoma, high grade dysplasia, and low grade dysplasia in 49.9 %, 22.7 %, and 17.1 %, respectively. Perforation, early and delayed bleeding occurred in 2.4 %, 4.3 %, and 3.4 %, respectively. Rates of en bloc and R0 resection, and recurrence on first endoscopic follow-up were 94.7 %, 83.4 %, and 2.7 %, respectively. Relative indication (2018 guideline) for ESD was associated with R1 outcome (P = 0.02). Distal location (P = 0.002) and increased procedure time (P = 0.04) were associated with bleeding, and scarring (P = 0.009) and increased procedure duration (P = 0.003) were associated with perforation. Recurrence-free survival at 2 and 5 years was 94 % and 83 %, respectively. CONCLUSION: This is the largest Western multicenter cohort and suggests that gastric ESD is safe and effective in the Western setting. A quarter of patients fell outside the new absolute indications for ESD, suggesting that Western practice involves more advanced lesions. We identified the predictors of complications, which should help to inform future Western practice and research.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Gástricas , Humanos , Masculino , Anciano , Femenino , Resultado del Tratamiento , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , Estudios Retrospectivos , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Endoscopía , Mucosa Gástrica/cirugía , Mucosa Gástrica/patología
4.
BMJ Case Rep ; 20172017 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-28069781

RESUMEN

A 61-year-old man presented with accumulation of ascites secondary to alcoholic liver disease. He had an ascitic drain sited and 24 hours later he developed acute colonic pseudo-obstruction (ACPO). This is a rare condition previously associated with major surgery and severe sepsis. The patient did well with conservative management, and avoided the need for endoscopic decompression or surgical intervention. We believe that this is the first report of ACPO secondary to abdominal paracentesis.


Asunto(s)
Seudoobstrucción Colónica/etiología , Paracentesis/efectos adversos , Enfermedad Aguda , Ascitis/diagnóstico por imagen , Ascitis/terapia , Colon Transverso/diagnóstico por imagen , Seudoobstrucción Colónica/diagnóstico por imagen , Diagnóstico Diferencial , Drenaje , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA