Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38059633

RESUMEN

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Asunto(s)
Enfermedad de Crohn , Enfermedades Intestinales , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Grasa Intraabdominal/diagnóstico por imagen , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos
2.
Vascular ; : 17085381231214318, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38031998

RESUMEN

INTRODUCTION: Aortic graft infection (AGI) is a rare complication following endovascular aneurysm repair and is associated with substantial morbidity and mortality. The traditional management of AGI is intravenous antibiotic therapy and surgical explantation. In this case series, percutaneous drainage was used as a bridge therapy in the treatment of AGI. METHODS: We report two cases, 78-year-old male and 57-year-old female, in whom image-guided percutaneous drainage was used to treat AGI in two contrasting contexts. Informed consent was obtained from both cases/relatives for publication. RESULTS: Both cases underwent successful percutaneous drainage of AGI utilized as a bridge therapy before definitive surgical reconstruction and graft explantation. Each patient had a different outcome. In the first case, the patient's comorbidities and severe disease state could not be overcome, resulting in his death. The second patient benefitted from the percutaneous drainage by allowing her more time ameliorate her malnutrition before definitive surgery. CONCLUSION: Data on the outcomes of percutaneous drainage of AGI is limited. The successful procedure described in this case series emphasizes the need to conduct more research to evaluate the safety and efficacy of this treatment approach before the surgical explantation.

3.
Clin Gastroenterol Hepatol ; 20(10): 2327-2336.e4, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34968729

RESUMEN

BACKGROUND & AIMS: Postoperative Crohn's disease (CD) surveillance relies on endoscopic monitoring. The role of cross-sectional imaging is less clear. We evaluated the concordance of cross-sectional enterography with endoscopic recurrence and the predictive ability of radiography for future CD postoperative recurrence. METHODS: We performed a multi-institution retrospective cohort study of postoperative adult patients with CD who underwent ileocolonoscopy and cross-sectional enterography within 90 days of each other following ileocecal resection. Imaging studies were interpreted by blinded, expert CD radiologists. Patients were categorized by presence of endoscopic postoperative recurrence (E+) (modified Rutgeerts' score ≥i2b) or radiographic disease activity (R+) and grouped by concordance status. RESULTS: A total of 216 patients with CD with paired ileocolonoscopy and imaging were included. A majority (54.2%) exhibited concordance (34.7% E+/R+; 19.4% E-/R-) between studies. The plurality (41.7%; n = 90) were E-/R+ discordant. Imaging was highly sensitive (89.3%), with low specificity (31.8%), in detecting endoscopic postoperative recurrence. Intestinal wall thickening, luminal narrowing, mural hyper-enhancement, and length of disease on imaging were associated with endoscopic recurrence (all P < .01). Radiographic disease severity was associated with increasing Rutgeerts' score (P < .001). E-/R+ patients experienced more rapid subsequent endoscopic recurrence (hazard ratio, 4.16; P = .033) and increased rates of subsequent endoscopic (43.8% vs 22.7%) and surgical recurrence (20% vs 9.5%) than E-/R- patients (median follow-up, 4.5 years). CONCLUSIONS: Cross-sectional imaging is highly sensitive, but poorly specific, in detecting endoscopic disease activity and postoperative recurrence. Advanced radiographic disease correlates with endoscopic severity. Patients with radiographic activity in the absence of endoscopic recurrence may be at increased risk for future recurrence, and closer monitoring should be considered.


Asunto(s)
Enfermedad de Crohn , Adulto , Colon/cirugía , Colonoscopía/métodos , Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/cirugía , Humanos , Íleon/cirugía , Recurrencia , Estudios Retrospectivos
4.
Clin Gastroenterol Hepatol ; 20(4): 817-846.e10, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34089850

RESUMEN

BACKGROUND AND AIMS: Intestinal strictures are a common complication of Crohn's disease (CD). Biomarkers of intestinal strictures would assist in their prediction, diagnosis, and monitoring. Herein we provide a comprehensive systematic review of studies assessing biomarkers that may predict or diagnose CD-associated strictures. METHODS: We performed a systematic review of PubMed, EMBASE, ISI Web of Science, Cochrane Library, and Scopus to identify citations pertaining to biomarkers of intestinal fibrosis through July 6, 2020, that used a reference standard of full-thickness histopathology or cross-sectional imaging or endoscopy. Studies were categorized based on the type of biomarker they evaluated (serum, genetic, histopathologic, or fecal). RESULTS: Thirty-five distinct biomarkers from 3 major groups were identified: serum (20 markers), genetic (9 markers), and histopathology (6 markers). Promising markers include cartilage oligomeric matrix protein, hepatocyte growth factor activator, and lower levels of microRNA-19-3p (area under the curves were 0.805, 0.738, and 0.67, respectively), and multiple anti-flagellin antibodies (A4-Fla2 [odds ratio, 3.41], anti Fla-X [odds ratio, 2.95], and anti-CBir1 [multiple]). Substantial heterogeneity was observed and none of the markers had undergone formal validation. Specific limitations to acceptance of these markers included failure to use a standardized definition of stricturing disease, lack of specificity, and insufficient relevance to the pathogenesis of intestinal strictures or incomplete knowledge regarding their operating properties. CONCLUSIONS: There is a lack of well-defined studies on biomarkers of intestinal stricture. Development of reliable and accurate biomarkers of stricture is a research priority. Biomarkers can support the clinical management of CD patients and aid in the stratification and monitoring of patients during clinical trials of future antifibrotic drug candidates.


Asunto(s)
Enfermedad de Crohn , Obstrucción Intestinal , MicroARNs , Biomarcadores , Proteína de la Matriz Oligomérica del Cartílago , Constricción Patológica/etiología , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/patología , Humanos , Obstrucción Intestinal/etiología , Serina Endopeptidasas
5.
Gastroenterology ; 160(7): 2303-2316.e11, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33609503

RESUMEN

BACKGROUND & AIMS: No reliable method for evaluating intestinal fibrosis in Crohn's disease (CD) exists; therefore, we developed a computed-tomography enterography (CTE)-based radiomic model (RM) for characterizing intestinal fibrosis in CD. METHODS: This retrospective multicenter study included 167 CD patients with 212 bowel lesions (training, 98 lesions; test, 114 lesions) who underwent preoperative CTE and bowel resection at 1 of the 3 tertiary referral centers from January 2014 through June 2020. Bowel fibrosis was histologically classified as none-mild or moderate-severe. In the training cohort, 1454 radiomic features were extracted from venous-phase CTE and a machine learning-based RM was developed based on the reproducible features using logistic regression. The RM was validated in an independent external test cohort recruited from 3 centers. The diagnostic performance of RM was compared with 2 radiologists' visual interpretation of CTE using receiver operating characteristic (ROC) curve analysis. RESULTS: In the training cohort, the area under the ROC curve (AUC) of RM for distinguishing moderate-severe from none-mild intestinal fibrosis was 0.888 (95% confidence interval [CI], 0.818-0.957). In the test cohort, the RM showed robust performance across 3 centers with an AUC of 0.816 (95% CI, 0.706-0.926), 0.724 (95% CI, 0.526-0.923), and 0.750 (95% CI, 0.560-0.940), respectively. Moreover, the RM was more accurate than visual interpretations by either radiologist (radiologist 1, AUC = 0.554; radiologist 2, AUC = 0.598; both, P < .001) in the test cohort. Decision curve analysis showed that the RM provided a better net benefit to predicting intestinal fibrosis than the radiologists. CONCLUSIONS: A CTE-based RM allows for accurate characterization of intestinal fibrosis in CD.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/patología , Intestinos/diagnóstico por imagen , Intestinos/patología , Tomografía Computarizada por Rayos X/normas , Adulto , Enfermedad de Crohn/complicaciones , Femenino , Fibrosis , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos
6.
Gastroenterology ; 158(1): 137-150.e1, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31476299

RESUMEN

BACKGROUND & AIMS: Stenosis is a common complication of Crohn's disease (CD) that has no effective medical therapy. Development of antifibrotic agents will require testing in randomized controlled trials. Computed tomography enterography- and magnetic resonance enterography-based technologies might be used to measure outcomes in these trials. These approaches have been validated in studies of patients with symptomatic strictures who underwent imaging evaluations followed by resection with histopathologic grading of the intestinal tissue for inflammation and/or fibrosis (the reference standard). Imaging findings have correlated with findings from quantitative or semiquantitative histologic evaluation of the degree of fibromuscular stenosis and/or inflammation on the resection specimen. However, it is not clear whether histologic findings are an accurate reference standard. We performed a systematic review of all published histologic scoring systems used to assess stenosing CD. METHODS: We performed a comprehensive search of Embase and MEDLINE of studies through March 13, 2019, that used a histologic scoring system to characterize small bowel CD and assessed inflammatory and fibrotic alterations within the same adult individual. All scores fitting the criteria were included in our analysis, independent of the presence of stricturing disease, as long as inflammation and fibrosis were evaluated separately but in the same scoring system. RESULTS: We observed substantial heterogeneity among the scoring systems, which were not derived from modern principles for evaluative index development. None had undergone formal validity or reliability testing. None of the existing indices had been constructed according to accepted methods for the development of evaluative indices. Basic knowledge regarding their operating properties were lacking. Specific indices for evaluating the important pathologic component of myofibroblast hypertrophy or hyperplasia have not been proposed. CONCLUSIONS: In a systematic review of publications, we found a lack of validated histopathologic scoring systems for assessment of fibromuscular stenosis. Data that describe the operating properties of existing cross-sectional imaging techniques for stenosing CD should be questioned. Development and validation of a histopathology index is an important research priority.


Asunto(s)
Constricción Patológica/diagnóstico , Enfermedad de Crohn/complicaciones , Íleon/patología , Índice de Severidad de la Enfermedad , Constricción Patológica/etiología , Constricción Patológica/cirugía , Fibrosis , Humanos , Íleon/diagnóstico por imagen , Íleon/cirugía , Imagen por Resonancia Magnética , Estándares de Referencia , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
7.
J Appl Clin Med Phys ; 22(2): 138-144, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33368998

RESUMEN

PURPOSE: The purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low-contrast low-attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model. METHODS: A phantom with four unique LCLA liver lesions (5- to 15-mm spheres, -24 to -6 HU relative to 90-HU background) was scanned without ("thin" phantom) and with ("obese" phantom) a 5-cm thick fat-attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model-Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed. RESULTS: Mean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom. CONCLUSIONS: Accuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.


Asunto(s)
Algoritmos , Neoplasias Hepáticas , Humanos , Obesidad , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador
8.
Radiographics ; 40(2): 354-375, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31951512

RESUMEN

Representatives from the Society of Abdominal Radiology Crohn's Disease-Focused Panel, the Society for Pediatric Radiology, the American Gastroenterological Association, and other international experts recently reported consensus recommendations for standardized nomenclature for the interpretation and reporting of CT enterography and MR enterography findings of small bowel Crohn disease. The consensus recommendations included CT enterography and MR enterography bowel wall findings that are associated with Crohn disease, findings that occur with penetrating Crohn disease, and changes that occur in the mesentery related to Crohn disease. Also included were recommended radiology report impression statements that summarize the findings of small bowel Crohn disease at CT enterography and MR enterography. This article, authored by the Society of Abdominal Radiology Crohn's Disease-Focused Panel, illustrates the imaging findings and recommended radiology report impression statements described in the consensus recommendations with examples of CT enterography and MR enterography images. Additional interpretation guidelines for reporting CT enterography and MR enterography examinations are also presented. The recommended standardized nomenclature can be used to generate radiology report dictations that will help guide medical and surgical management for patients with small bowel Crohn disease. Online supplemental material is available for this article. ©RSNA, 2020See discussion on this article by Heverhagen.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Intestino Delgado/diagnóstico por imagen , Imagen por Resonancia Magnética , Terminología como Asunto , Tomografía Computarizada por Rayos X , Humanos
9.
AJR Am J Roentgenol ; 212(3): 490-496, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30620681

RESUMEN

OBJECTIVE: The purposes of this article are to describe the creation of template report formats and content for a variety of abdominal and pelvic CT and MRI examinations and discuss a review-of-systems approach to text and avoidance of pitfalls of report templates. CONCLUSION: Organ system-specific report templates for CT and MRI incorporate radiologist preferences. Disease-specific report templates are created from these reports to provide a consistent radiologist and referring physician experience across the report templates.


Asunto(s)
Imagen por Resonancia Magnética , Registros Médicos , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Control de Formularios y Registros , Humanos
10.
Clin Gastroenterol Hepatol ; 20(12): 2925-2926, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35149221
11.
Radiology ; 280(2): 475-82, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26937709

RESUMEN

Purpose To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. Materials and Methods An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. Results The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers' confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. Conclusion IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Artefactos , Hígado/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Fantasmas de Imagen , Exposición a la Radiación/estadística & datos numéricos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Humanos , Tomografía Computarizada Multidetector/estadística & datos numéricos , Dosis de Radiación , Relación Señal-Ruido
12.
Radiology ; 280(2): 436-45, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27077382

RESUMEN

Purpose To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dual-source CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P < .003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P < .001). Conclusion The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality. (©) RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Ileítis/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Enfermedad de Crohn/complicaciones , Femenino , Tracto Gastrointestinal/diagnóstico por imagen , Humanos , Ileítis/complicaciones , Íleon/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
14.
AJR Am J Roentgenol ; 205(3): 592-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26295647

RESUMEN

OBJECTIVE: The purposes of this study were to determine the differences in estimated volumetric CT dose index (CTDIvol) obtained from the topogram before abdominal and pelvic MDCT in adult and pediatric patients using a scan type-based algorithm for selecting kilovoltage (CARE kV) and a fixed and a weight-based Quality Reference mAs for selecting tube (gmAs) current-exposure time product, in comparison with standard protocols, and to determine the bias and variability of estimated CTDIvol vis-à-vis actual CTDIvol using the standard protocols. MATERIALS AND METHODS: During a 14-month period, 312 adult and pediatric patients referred for abdominal and pelvic MDCT were included in the study. For all patients, the estimated CTDIvol based on the topogram was recorded: protocol A, CARE kV on and 210 gmAs; protocol B, CARE kV on and 1 gmAs times patient weight (in pounds); and protocol C (standard protocol), CARE kV off, 120 kVp, and 1 gmAs times patient weight (in pounds). For the pediatric patients, estimated CTDIvol for the standard protocol D was calculated with 120 kVp and 150 gmAs. All patients were scanned with the standard protocols, and the actual CTDIvol was recorded. Linear regression models compared the CTDIvol of the three protocols in adults and the fourth for children. The estimated and actual CTDIvol were compared using a t test. RESULTS: Protocol B yielded the lowest estimated CTDIvol (mean, 13.2 mGy for adults and 3.5 mGy for pediatric patients). The estimated CTDIvol overestimated the actual CTDIvol by, on average, 1.07 mGy for adults and 0.3 mGy for children. CONCLUSION: CARE kV appears to reduce estimated CTDIvol vis-à-vis standard protocols only when a weight-based gmAs is used. Prescan estimated CTDIvol calculations appear to generally overestimate actual CTDIvol.


Asunto(s)
Tomografía Computarizada Multidetector/instrumentación , Dosis de Radiación , Adolescente , Adulto , Algoritmos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Radiografía Abdominal
15.
Abdom Imaging ; 40(5): 938-52, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25637126

RESUMEN

CT enterography (CTE) is a common examination for patients with Crohn's disease. In order to achieve high quality, diagnostic images, proper technique is required. The purpose of this treatise is to review the processes and techniques that can optimize CTE for patients with suspected or known Crohn's disease. We will review the following: (1) how to start a CT enterography program; (2) workflow issues, including patient and ordering physician education and preparation; (3) oral contrast media options and administration regimens; (4) intravenous contrast media injection for uniphasic and multiphasic studies; (5) CTE radiation dose reduction strategies and the use of iterative reconstruction in lower dose examinations; (6) image reconstruction and interpretation; (7) imaging Crohn's patients in the acute or emergency department setting; (8) limitations of CTE as well as alternatives such as MRE or barium fluoroscopic examinations; and (9) dictation templates and a common nomenclature for reporting findings of CTE in Crohn's disease. Many of the issues discussed are summarized in the Abdominal Radiology Society Consensus MDCT Enterography Acquisition Protocol for Crohn's Disease.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Sulfato de Bario , Medios de Contraste , Humanos , Intestinos/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica , Sensibilidad y Especificidad
16.
Radiology ; 272(1): 154-63, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24620913

RESUMEN

PURPOSE: To measure the effect of reduced radiation exposure on low-contrast low-attenuation liver lesion detection in an anthropomorphic abdominal phantom by using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction. MATERIALS AND METHODS: Eighteen radiologists blinded to phantom and study design interpreted randomized image data sets that contained 36 spherical simulated liver lesions of three sizes and three attenuation differences (5-mm diameter: 12, 18, and 24 HU less than the 90-HU background attenuation of the simulated liver insert; 10- and 15-mm diameter: 6, 12, and 18 HU less than the 90-HU background attenuation) scanned with four discrete exposure settings and reconstructed by using FBP and sinogram-affirmed iterative reconstruction. Response assessment included region-level lesion presence or absence on a five-point diagnostic confidence scale. Statistical evaluation included multireader multicase receiver operating characteristic curve analysis, with nonparametric methods and noninferiority analysis at a margin of -0.10. RESULTS: Pooled accuracy at 75% exposure for both FBP and sinogram-affirmed iterative reconstruction was noninferior to 100% exposure (P = .002 and P < .001, respectively). Subsequent exposure reductions resulted in a significant decrease in accuracy. When the smallest (5-mm-diameter) lesions were excluded from analysis, sinogram-affirmed iterative reconstruction was superior to FBP at 100% exposure (P = .011), and sinogram-affirmed iterative reconstruction at 25% and 50% exposure reduction was noninferior to FBP at 100% exposure (P ≤ .013). Reader confidence was greater with sinogram-affirmed iterative reconstruction than with FBP for 10- and 15-mm lesions (2.94 vs 2.76 and 3.62 vs 3.52, respectively). CONCLUSION: In this low-contrast low-attenuation liver lesion model, a 25% exposure reduction maintained noninferior diagnostic accuracy. However, detection was inferior with each subsequent exposure reduction, regardless of reconstruction method. Sinogram-affirmed iterative reconstruction and FBP performed equally well at modest exposure reduction (25%-50%). Readers had higher confidence levels with sinogram-affirmed iterative reconstruction for the 10- and 15-mm lesions.


Asunto(s)
Hepatopatías/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Programas Informáticos
17.
Radiology ; 272(3): 749-56, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24814177

RESUMEN

PURPOSE: To compare images acquired with 50% tube exposure with a dual-source computed tomographic (CT) scanner and reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE) with 100% exposure images reconstructed with filtered back projection (FBP) for reader ability to detect stones, reader confidence, and findings outside the urinary tract. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved study, imaging examinations in 99 patients with urolithiasis were assessed. Data from both tubes were reconstructed with FBP; data from the primary tube only were reconstructed with SAFIRE. Seven readers evaluated randomized studies for calculi in nine regions. Reader confidence was scored by using a five-point scale. Ancillary findings were noted. Nonparametric methods for clustered data were used to estimate the area under the receiver operating characteristic curves with 95% confidence intervals to test for noninferiority of 50% exposure with SAFIRE. RESULTS: Calculi were found in 113 locations (pyelocalyceal ureter, 86; proximal ureter, seven; midureter, four; distal ureter, 15; bladder, one) and not found in 752 locations. Mean area under the receiver operating characteristic curve for FBP was 0.879 (range, 0.607-0.967) and for SAFIRE, 0.883 (range, 0.646-0.971; 95% confidence interval: -0.025, 0.031). The SAFIRE images were not significantly inferior to FBP images (P = .001). Reader confidence levels for images with stones were similar with FBP and SAFIRE (P = .963). For the 52 patients who had extraurinary findings, readers reported them correctly in 74.4% (271 of 364) and 72.0% (262 of 364) of cases (P = .215) for FBP and SAFIRE, respectively. For the nine patients with potentially important findings per the reference standard, the detection rates were 44% (28 of 63) and 33% (21 of 63, P = .024), respectively. For the 43 patients with unimportant or likely unimportant findings, the false detection rates were 15% (44 of 301) and 14% (43 of 301, P = .756), respectively. CONCLUSION: The 50% tube exposure CT images reconstructed with SAFIRE were not inferior to 100% exposure images reconstructed with FBP for diagnosis of urolithiasis, without decreases in reader confidence.


Asunto(s)
Algoritmos , Almacenamiento y Recuperación de la Información/métodos , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Urolitiasis/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Artículo en Inglés | MEDLINE | ID: mdl-38831007

RESUMEN

Fibrostenosis of the small bowel is common in patients with Crohn's disease. No consensus recommendations on definition, diagnosis and management in clinical practice are currently available. In this Consensus Statement, we present a clinical practice RAND/UCLA appropriateness study on the definition, diagnosis and clinical management of fibrostenosing Crohn's disease. It was conducted by a panel of 28 global experts and one patient representative. Following a systematic literature review, 526 candidate items grouped into 136 questions were generated and subsequently evaluated for appropriateness. Strictures are best defined as wall thickening, luminal narrowing and prestenotic dilation. Cross-sectional imaging is required for accurate diagnosis of fibrostenosing Crohn's disease, and it is recommended before making treatment decisions. It should also assess the degree of inflammation in the bowel wall. Multiple options for medical anti-inflammatory, endoscopic and surgical therapies were suggested, including follow-up strategies following therapy. This Consensus Statement supports clinical practice through providing guidance on definitions, diagnosis and therapeutic management of patients with fibrostenosing small bowel Crohn's disease.

19.
Aliment Pharmacol Ther ; 59(8): 928-940, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38436124

RESUMEN

BACKGROUND: Stricturing Crohn's disease (CD) occurs most commonly in the terminal ileum and poses a clinical problem. Cross-sectional imaging modalities such as intestinal ultrasound (IUS), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) allow for assessment of the entire bowel wall and associated peri-enteric findings. Radiologic definitions of strictures have been developed for CTE and MRE; their reliability and responsiveness are being evaluated in index development programs. A comprehensive assessment strategy for strictures using IUS is needed. AIMS: To provide a detailed summary of definitions, diagnosis and monitoring of strictures on IUS as well as technical aspects of image acquisition. METHODS: We searched four databases up to 6 January 2024. Two-stage screening was done in duplicate. We assessed risk of bias using QUADAS-2. RESULTS: There were 56 studies eligible for inclusion. Definitions for strictures on IUS are heterogeneous, but the overall accuracy for diagnosis of strictures is high. The capability of IUS for characterising inflammation versus fibrosis in strictures is not accurate enough to be used in clinical practice or trials. We summarise definitions for improvement of strictures on IUS, and discuss parameters for image acquisition and standardisation. CONCLUSIONS: This systematic review is the first step for a structured program to develop a stricture IUS index for CD.


Asunto(s)
Enfermedad de Crohn , Obstrucción Intestinal , Humanos , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/diagnóstico por imagen , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/patología , Reproducibilidad de los Resultados , Intestinos/patología , Imagen por Resonancia Magnética/métodos
20.
AJR Am J Roentgenol ; 200(6): 1298-303, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23701068

RESUMEN

OBJECTIVE: The purpose of this article is to determine the decrease in volume CT dose index (CTDI(vol)) and dose-length product (DLP) achieved by switching from fixed quality reference tube current protocols with automatic tube current modulation to protocols adjusting the quality reference tube current, slice collimation, and peak kilovoltage according to patient weight. MATERIALS AND METHODS: All adult patients who underwent CT examinations of the abdomen or abdomen and pelvis during 2010 using weight-based protocols who also underwent a CT examination in 2008 or 2009 using fixed quality reference tube current protocols were identified from the radiology information system. Protocol pages were electronically retrieved, and the CT model, examination date, scan protocol, CTDI(vol), and DLP were extracted from the DICOM header or by optical character recognition. There were 15,779 scans with dose records for 2700 patients. Changes in CTDI(vol) and DLP were compared only between examinations of the same patient and same CT system model for examinations performed in 2008 or 2009 and those performed in 2010. The final analysis consisted of 1117 comparisons in 1057 patients, and 1209 comparisons in 988 patients for CTDI(vol) and DLP, respectively. RESULTS: The change to a weight-based protocol resulted in a statistically significant reduction in CTDI(vol) and DLP on three MDCT system models (p < 0.001). The largest average CTDI(vol) decrease was 13.9%, and the largest average DLP decrease was 16.1% on a 64-MDCT system. Both the CTDI(vol) and DLP decreased the most for patients who weighed less than 250 lb (112.5 kg). CONCLUSION: Adjusting the CT protocol by selecting parameters according to patient weight is a viable method for reducing CT radiation dose. The largest reductions occurred in the patients weighing less than 250 lb.


Asunto(s)
Peso Corporal , Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Protección Radiológica/métodos , Radiografía Abdominal/métodos , Adulto , Protocolos Clínicos , Femenino , Humanos , Modelos Lineales , Masculino , Tomografía Computarizada Multidetector/instrumentación , Selección de Paciente , Radiografía Abdominal/instrumentación , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA