Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Arch Phys Med Rehabil ; 102(6): 1091-1101, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33493439

RESUMEN

OBJECTIVE: To examine political participation after traumatic brain injury (TBI). DESIGN: Qualitative, participatory research via interviews and observations. Each participant was interviewed to discuss their experience of voting in 2007 or 2008. Data were coded using Grounded Theory to develop themes, metacodes, and theories. SETTING: Community. PARTICIPANTS: A total of 57 individuals with history of TBI and 28 family members (N=85). MAIN OUTCOME MEASURES: Not applicable. RESULTS: Four themes emerged from the data: (1) people with TBI have barriers to voting; (2) the voting process can be improved for people with TBI; (3) voting is the responsibility of members of society; and (4) voting is one way we have a voice in society. CONCLUSIONS: The data support the importance of voting as an American right regardless of the presence of disability. While persons with TBI report voting represents their freedom and voice, there may be barriers that can threaten or limit their voice.


Asunto(s)
Lesiones Traumáticas del Encéfalo/psicología , Personas con Discapacidad/psicología , Empoderamiento , Familia/psicología , Política , Adulto , Investigación Participativa Basada en la Comunidad , Femenino , Teoría Fundamentada , Humanos , Masculino , Persona de Mediana Edad , North Carolina , Investigación Cualitativa
2.
J Man Manip Ther ; 27(3): 162-171, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30935326

RESUMEN

Objectives: Prudent dry needling techniques are commonly practiced with the intent to avoid large neurovascular structures, thereby minimizing potential excessive bleeding and neural injury. Patient position is one factor thought to affect the size of the safe zone during dry needling of some muscles. This study aimed to compare the size of the needle safe zone of the iliacus muscle during two different patient positions using ultrasound imaging. Methods: The distance from the anterior inferior iliac spine (AIIS) to the posterior pole of the femoral nerve was measured in 25 healthy participants (11 male, 14 female, mean age = 40) in both supine and sidelying positions using a Chison Eco1 musculoskeletal ultrasound unit. The average distance was calculated for each position and a two-tailed, paired t-test (α < 0.05) was used to examine the difference between positions. Results: The mean distance from the AIIS to the posterior pole of the femoral nerve was statistically greater with participants in the sidelying position (mean[SD] = 35.7 [6.2] mm) than in the supine position (mean[SD] = 32.1 [7.3] mm, p < .001). Discussion: Although more study is needed, these results suggest that patient positioning is one of several potential variables that should be considered in the optimization of patient safety/relative risk when performing trigger point dry needling. Level of Evidence: Level 4 (Pre-Post Test).


Asunto(s)
Punción Seca , Nervio Femoral , Músculo Esquelético , Posicionamiento del Paciente/métodos , Puntos Disparadores , Adulto , Punción Seca/efectos adversos , Punción Seca/métodos , Femenino , Nervio Femoral/diagnóstico por imagen , Nervio Femoral/fisiología , Cadera/diagnóstico por imagen , Cadera/fisiología , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/fisiología , Riesgo , Puntos Disparadores/diagnóstico por imagen , Puntos Disparadores/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA