Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
BMC Oral Health ; 24(1): 228, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38350901

RESUMEN

BACKGROUND: The purpose of this study is to evaluate the marginal adaptation of bulk-fill resin composites with different viscosities (paste-like and flowable) in Class II restorations using micro-CT imaging. METHODS: Forty extracted human molars were used. Mesial and distal Class II box cavities (approximately 3 mm x 3 mm x 4 mm) were prepared for each tooth, with cavity floors located 1 mm below the enamel-cementum junction. Following adhesive application, teeth were restored using eight different groups: Group XB: X-tra Base Bulk-fill Flowable (VOCO), Group XF: X-tra Fill Bulk-fill (VOCO), Group FB: Filtek Bulk-fill Posterior (3 M ESPE), Group FF: Filtek Bulk-fill Flowable (3 M ESPE), Group BB: Beautifil-Bulk (SHOFU), Group BF: Beautifil-Bulk Flowable (SHOFU), and Group CO: "as a control group", Clearfil Majesty Posterior (KURARAY) and Group CF: "as a control group", Clearfil Majesty Flow + Clearfil Majesty Posterior (KURARAY). The restored teeth underwent an aging protocol involving 1000 cycles in a water bath fluctuating between 5 ± 1.0 °C and 55 ± 1.0 °C. Post-aging, teeth were immersed in 50% silver nitrate solution for 24 h and then in a film developer solution for 8 h. Microleakage analysis was performed using micro-CT, evaluated with 3D Slicer software. A two-way ANOVA was employed for statistical analysis. RESULTS: Two-way ANOVA results indicated significant effects of both viscosity (p < 0.0001) and composite type (p < 0.0001) on marginal adaptation. Viscosity analysis (comparing flowable and paste-like) revealed no significant differences in the FB-FF, XB-XF and BB-BF groups but significant differences in the and CO-CF group, with flowable type exhibiting less microleakage than paste-like type. CONCLUSIONS: The study suggests that while the viscosity of bulk-fill composites did not significantly affect marginal adaptation, the brand of bulk-fill composite did influence it.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Humanos , Viscosidad , Restauración Dental Permanente/métodos , Microtomografía por Rayos X , Ensayo de Materiales , Diente Molar/diagnóstico por imagen
2.
Medicina (Kaunas) ; 60(3)2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38541122

RESUMEN

Background and Objectives: The aim of this quantitative research was to investigate the effect of gravitational forces on the marginal integrity of different bulk-fill composites by micro-CT imaging. Materials and Methods: Fifty caries-free human third molars extracted for prophylactic purposes were used in this study. Each tooth was prepared with two proximal box cavities, with dimensions of 3 mm × 3 mm × 5 mm. Five distinct groups, each comprising 20 cavities, thus totaling 100 cavities for this study: (1, Group CON): Clearfil Majesty Flow + Clearfil Majesty Esthetic (as the control); (2, Group FBR): Filtek Bulk-fill Flowable Restorative + Clearfil Majesty Esthetic; (3, Group XTB): Voco Extrabase + Clearfil Majesty Esthetic; (4, Group SDR): SDR + Clearfil Majesty Esthetic; and (5, Group SNC): Sonicfill. When restoring the mesial cavities, the occlusal surfaces of the teeth in the mold were positioned upwards, counteracting the force of gravity. In contrast, for the restoration of the distal cavities, the occlusal surfaces were aligned downwards, to be parallel with the gravitational pull. After restorative procedures, each tooth was treated with 5000 thermal cycles. A solution of ammoniacal silver nitrate (AgNO3) was employed as a tracing agent. The micro-CT scans were conducted and the total volume of silver nitrate and the total volume of restorations within the relevant region of interest were calculated in "mm3" with software. Two-way ANOVA and Tukey tests were performed at a significance level of p = 0.05 with Graphpad Prism v 8.2.1 software. Results: Both gravity effect and interaction showed no statistical differences (p > 0.05). Statistically significant differences were observed in the restorative materials (p < 0.05). Conclusions: Gravitational forces do not emerge as a major factor affecting the marginal integrity of flowable bulk-fill composites in class II restorations. The chemical composition of the composites plays a more crucial role, with the XTB composite showing higher microleakage ratios compared to the others.


Asunto(s)
Resinas Sintéticas , Microtomografía por Rayos X , Humanos , Diente Molar
3.
BMC Oral Health ; 17(1): 130, 2017 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-29145846

RESUMEN

BACKGROUND: Although numerous studies have used digital intraoral imaging, only a few studies have used photo-optical methods for the diagnosis of caries. Moreover, several limitations exist in terms of observers (experience and specialty) and the caries lesion itself. Hence, the aims of this study were to evaluate the diagnostic capability of near-infrared light transillumination (NILT) and PSP-Bitewing radiographs and to compare the interobserver and intraobserver differences in addition to observers' experience level to detect early interproximal caries lesions in vivo. METHODS: A total of 52 untreated posterior teeth with and without varying degrees of early interproximal carious lesions were included. Bitewing radiographs using digital phosphor plates (PSP-Bitewing) and NILT were used to clarify the diagnosis. An oral and maxillofacial radiologist and a restorative dentistry consultant evaluated the images twice. A separate appointment for clinical validation and restoration was made. Kappa coefficients were calculated to assess both intraobserver and interobserver agreements for each evaluation method. Scores obtained from PSP-Bitewing and NILT were compared with the clinical validation via receiver operating characteristic (ROC) analysis. RESULTS: No significant differences were found between PSP-Bitewing radiography and NILT for detecting early interproximal carious lesions with high average Az results. Both intraobserver and interobserver agreement values were relatively higher for NILT evaluation. The Az values increased at second evaluations for both caries detection methods. CONCLUSIONS: NILT examination has an appropriate sensitivity and diagnostic accuracy for detecting early interproximal caries lesions and can be considered as a method of choice for detecting caries without the use of ionizing radiation.


Asunto(s)
Caries Dental/diagnóstico , Rayos Infrarrojos , Radiografía de Mordida Lateral , Transiluminación , Diagnóstico Precoz , Humanos , Variaciones Dependientes del Observador , Curva ROC , Radiografía de Mordida Lateral/instrumentación , Estudios Retrospectivos
4.
BMC Oral Health ; 16(1): 77, 2016 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-27549333

RESUMEN

BACKGROUND: Air-drying of etched and rinsed dentin surface may force the exposed collagen fibrils to collapse. Blot-drying is an alternative method to wipe the excess water from the dentin surface without compromising the monomer penetration. Contemporary total etch adhesives contain ethanol/water or acetone as solvent in which resin monomers are dissolved. Solvent type of the adhesive system has an important role in bonding to dentin. An adhesive containing tertiary butanol as an alternative solvent has been in the market. Purpose of this study is to determine the shear bond strengths of three total-etch adhesives with different solvents (acetone, ethanol or tertiary butanol) applied to air or blot dried moist dentin. METHODS: Sixty extracted non-carious human third molars were divided into three main groups according to solvent content of the adhesives [acetone based - One Step (OS, Bisco, IL, USA); ethanol/water based - Optibond Solo Plus (OB, Kerr, CA, USA); and tertiary butanol based - XP Bond (XP, Caulk/Dentsply, DE, USA)]. Each main group was divided into two groups according to drying methods (blot or air) (n = 10). Shear bond strengths (SBS) were measured. Data were analyzed by Student's t test and Tukey HSD test (p < 0,05). RESULTS: XP showed highest SBS values in both drying methods applied (p < 0.05). Drying method did not influence the SBS in OS and OB (p > 0.05). XP-blot produced significantly higher SBS than XP-air (p < 0.05). CONCLUSIONS: Tertiary butanol based adhesive showed higher bond strength values than ethanol or acetone based adhesives. Blot drying of dentin improved the bond strength values of tertiary butanol based adhesive. Further research is necessary to determine in vivo and in vitro performance of tertiary butanol based adhesives.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Solventes/química , Resinas Compuestas , Dentina , Humanos , Ensayo de Materiales , Metacrilatos , Cementos de Resina , Resistencia al Corte , Resistencia a la Tracción , Agua
5.
Dent Mater J ; 43(3): 446-452, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692905

RESUMEN

This study evaluates the wear resistance of dental paste-like bulk-fill composites compared to conventional paste-like composite resins using an intraoral scanner and 3-D analyzing software. Six different dental composite materials, including five bulk-fill composites and one conventional composite, were tested alongside natural human enamel as a control group. A computer-controlled chewing simulator for wear testing. A one-way ANOVA test was used to identify any significant differences between the means of the tested dental composite materials α=0.05. The results showed variability among bulk-fill composites, with some demonstrating wear resistance similar to conventional composites (p<0.05). Human enamel displayed the lowest wear values, but some bulk-fill composites matched this resistance(p>0.05). Significant variability was observed among bulk-fill composites but the results were comparable to those of conventional composites. The enamel control group demonstrated the lowest wear values, with some bulk-fill composites showing similar wear resistance. This study provides valuable information about the wear resistance of contemporary bulk-fill composite materials, commonly used in current clinical practice, contributing to enhancing clinical procedures.


Asunto(s)
Resinas Compuestas , Esmalte Dental , Alisadura de la Restauración Dental , Ensayo de Materiales , Propiedades de Superficie , Resinas Compuestas/química , Humanos , Técnicas In Vitro , Imagenología Tridimensional , Materiales Dentales/química
6.
Artículo en Inglés | MEDLINE | ID: mdl-33281043

RESUMEN

OBJECTIVE: The objective of this study was to assess the effects of 3 T magnetic resonance imaging (MRI) on the microleakage of 5 restorative materials. METHODS: In total, 100 maxillary molars were randomly assigned to 5 groups (n = 20) for restoration with 5 different materials: amalgam, light-cured glass-ionomer cement, feldspathic porcelain fused to metal, pressed lithium disilicate glass ceramic, and composite resin. In each group, 10 specimens were subjected to MRI, and 10 specimens served as controls with no MRI exposure. Standardized class V cavities were prepared with occlusal margins terminating in enamel and gingival margins terminating in dentin. Microleakage penetration at the enamel and dentin margins was calculated for each group. A chi-square test was used for intergroup comparisons. Statistical significance was established at P < .05. RESULTS: Microleakage penetration did not differ significantly between specimens subjected to MRI and the controls for any restoration (P ≥ .362 for the enamel margin, P ≥ .067 for the dentin margin) or between specimens treated with different restorative materials (P ≥ .355). No significant differences in microleakage were discovered between the enamel and dentin margins of any of the restorative groups (P ≥ .236). CONCLUSION: MRI had no effect on the microleakage of the 5 restorative materials.


Asunto(s)
Filtración Dental , Imagen por Resonancia Magnética , Resinas Compuestas , Materiales Dentales , Restauración Dental Permanente , Dentina/diagnóstico por imagen , Cementos de Ionómero Vítreo , Humanos , Márgenes de Escisión , Ensayo de Materiales , Proyectos de Investigación
7.
Oper Dent ; 34(5): 578-85, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19830973

RESUMEN

OBJECTIVE: This in vitro study compared the effects of different layering techniques and different monomer-based composites on microleakage. METHOD AND MATERIALS: Thirty-two freshly extracted caries-free human third molars were used. A wide mesio-occlusal-distal (MOD) cavity was prepared in each third molar, with the occlusal dimension being approximately two-thirds of the intercuspal dimension, and the cervical limit of one proximal box was stopped 1 mm below and the other 1 mm above the cementoenamel junction. The cavities were filled with a methacrylate-based nanohybrid composite (Grandio, VoCo) and a silorane-based microhybrid composite (Filtek Silorane, 3M ESPE). All samples were subjected to 1000 thermal cycles of 5 degrees C/55 degrees C in water with a 30-second dwell time and, after the procedure, the teeth were immersed in a 0.5% basic fuchsin dye at 23 degrees C for 24 hours. Sectioned samples were examined under a stereomicroscope (Leica MZ12, Leica Microsystems), and microleakage scores were statistically analyzed using the Kruskal-Wallis and the Mann-Whitney U tests. RESULTS: No microleakage was observed for silorane-based resin composite restorations. The nanohybrid-based resin composite restorations showed different levels of leakage. Statistical analysis of microleakage scores showed differences only at the enamel margins for nanohybrid material for both layering techniques (p < 0.05). The nanohybrid-based resin composite restorations showed better results with the vertical layering technique for enamel margins.


Asunto(s)
Resinas Compuestas/administración & dosificación , Resinas Compuestas/química , Filtración Dental/prevención & control , Restauración Dental Permanente/métodos , Preparación de la Cavidad Dental/clasificación , Humanos , Tercer Molar , Nanocompuestos/administración & dosificación
8.
Restor Dent Endod ; 44(3): e23, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31485419

RESUMEN

OBJECTIVES: The aim of this study was to investigate the microshear bond strength (µSBS) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. MATERIALS AND METHODS: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The µSBS of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. RESULTS: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). CONCLUSIONS: The µSBS values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The µSBS values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

9.
Eur Oral Res ; 52(2): 75-81, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-30775706

RESUMEN

PURPOSE: The aim of this study was to determine the differences between the positional relationship of the crown contour and the pulp chamber of left and right maxillary first molars, as well as their morphological characteristics by using micro-CT system with reconstruction from a volumetric rendering software. MATERIALS AND METHODS: In total, 21 extracted maxillary first molars, including 11 left and 10 right teeth, were used. The positional relationship between the crown contour, pulp chamber and morphology of the teeth were investigated three-dimensionally by means of micro-CT imaging. RESULTS: Closest distance of mesio-buccal pulp horn to enamel surface in mm was calculated as 2.5±0.20 mm for right and 2.29±0.17 mm for left teeth. This difference was statistically significant (p=0.017). The means of closest distance of disto-buccal pulp horn to enamel surface were also significantly different between left and right teeth (p=0.001). The mean pulp volumes of right side and left side teeth were, respectively, 32.94±3.19 mm3 and 33.71±2.82 mm3 but this difference was not statistically significant. CONCLUSION: These results suggest that right and left maxillary first molars should be treated differently during preparation of cavities. Further studies must be done with larger samples as well as for other molar teeth in different populations to reveal the morphology of the molar for further considerations in restorative dentistry.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA