Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
NMR Biomed ; 33(1): e4215, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31730265

RESUMEN

Liver disease causes millions of deaths per year worldwide, and approximately half of these cases are due to cirrhosis, which is an advanced stage of liver fibrosis that can be accompanied by liver failure and portal hypertension. Early detection of liver fibrosis helps in improving its treatment and prevents its progression to cirrhosis. In this work, we present a novel noninvasive method to detect liver fibrosis from tagged MRI images using a machine learning-based approach. Specifically, coronal and sagittal tagged MRI imaging are analyzed separately to capture cardiac-induced deformation of the liver. The liver is manually delineated and a novel image feature, namely, the histogram of the peak strain (HPS) value, is computed from the segmented liver region and is used to classify the liver as being either normal or fibrotic. Classification is achieved using a support vector machine algorithm. The in vivo study included 15 healthy volunteers (10 males; age range 30-45 years) and 22 patients (15 males; age range 25-50 years) with liver fibrosis verified and graded by transient elastography, and 10 patients only had a liver biopsy and were diagnosed with a score of F3-F4. The proposed method demonstrates the usefulness and efficiency of extracting the HPS features from the sagittal slices for patients with moderate fibrosis. Cross-validation of the method showed an accuracy of 83.7% (specificity = 86.6%, sensitivity = 81.8%).


Asunto(s)
Corazón/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/diagnóstico , Aprendizaje Automático , Imagen por Resonancia Magnética , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sístole , Factores de Tiempo
2.
Magn Reson Med ; 81(1): 486-494, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30058096

RESUMEN

PURPOSE: To develop and evaluate an imaging sequence to simultaneously quantify the epicardial fat volume and myocardial T1 relaxation time. METHODS: We introduced a novel simultaneous myocardial T1 mapping and fat/water separation sequence (joint T1 -fat/water separation). Dixon reconstruction is performed on a dual-echo data set to generate water/fat images. T1 maps are computed using the water images, whereas the epicardial fat volume is calculated from the fat images. A phantom experiment using vials with different T1 /T2 values and a bottle of oil was performed. Additional phantom experiment using vials of mixed fat/water was performed to show the potential of this sequence to mitigate the effect of intravoxel fat on estimated T1 maps. In vivo evaluation was performed in 17 subjects. Epicardial fat volume, native myocardial T1 measurements and precision were compared among slice-interleaved T1 mapping, Dixon, and the proposed sequence. RESULTS: In the first phantom, the proposed sequence separated oil from water vials and there were no differences in T1 of the fat-free vials (P = .1). In the second phantom, the T1 error decreased from 22%, 36%, 57%, and 73% to 8%, 9%, 16%, and 26%, respectively. In vivo there was no difference between myocardial T1 values (1067 ± 17 ms versus 1077 ± 24 ms, P = .6). The epicardial fat volume was similar for both sequences (54.3 ± 33 cm3 versus 52.4 ± 32 cm3 , P = .8). CONCLUSION: The proposed sequence provides simultaneous quantification of native myocardial T1 and epicardial fat volume. This will eliminate the need for an additional sequence in the cardiac imaging protocol if both measurements are clinically indicated.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Técnicas de Imagen Cardíaca , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética , Miocardio/patología , Pericardio/diagnóstico por imagen , Adulto , Anciano , Algoritmos , Fibrilación Atrial/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Femenino , Voluntarios Sanos , Corazón/fisiopatología , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Agua , Adulto Joven
3.
Magn Reson Med ; 79(1): 351-360, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28382726

RESUMEN

PURPOSE: To develop a dark blood-late gadolinium enhancement (DB-LGE) sequence that improves scar-blood contrast and delineation of scar region. METHODS: The DB-LGE sequence uses an inversion pulse followed by T2 magnetization preparation to suppress blood and normal myocardium. Time delays inserted after preparation pulses and T2 -magnetization-prep duration are used to adjust tissue contrast. Selection of these parameters was optimized using numerical simulations and phantom experiments. We evaluated DB-LGE in 9 swine and 42 patients (56 ± 14 years, 33 male). Improvement in scar-blood contrast and overall image quality was subjectively evaluated by two independent readers (1 = poor, 4 = excellent). The signal ratios among scar, blood, and myocardium were compared. RESULTS: Simulations and phantom studies demonstrated that simultaneous nulling of myocardium and blood can be achieved by selecting appropriate timing parameters. The scar-blood contrast score was significantly higher for DB-LGE (P < 0.001) with no significant difference in overall image quality (P > 0.05). Scar-blood signal ratios for DB-LGE versus LGE were 5.0 ± 2.8 versus 1.5 ± 0.5 (P < 0.001) for patients, and 2.2 ± 0.7 versus 1.0 ± 0.4 (P = 0.0023) for animals. Scar-myocardium signal ratios were 5.7 ± 2.9 versus 6.3 ± 2.6 (P = 0.35) for patients, and 3.7 ± 1.1 versus 4.1 ± 2.0 (P = 0.60) for swine. CONCLUSIONS: The DB-LGE sequence simultaneously reduces normal myocardium and blood signal intensity, thereby enhancing scar-blood contrast while preserving scar-myocardium contrast. Magn Reson Med 79:351-360, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Sangre/diagnóstico por imagen , Medios de Contraste/química , Gadolinio/química , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Infarto del Miocardio/diagnóstico por imagen , Adulto , Anciano , Animales , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Modelos Teóricos , Miocardio/patología , Fantasmas de Imagen , Reproducibilidad de los Resultados , Porcinos
4.
J Cardiovasc Magn Reson ; 20(1): 22, 2018 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-29562921

RESUMEN

BACKGROUND: Low scar-to-blood contrast in late gadolinium enhanced (LGE) MRI limits the visualization of scars adjacent to the blood pool. Nulling the blood signal improves scar detection but results in lack of contrast between myocardium and blood, which makes clinical evaluation of LGE images more difficult. METHODS: GB-LGE contrast is achieved through partial suppression of the blood signal using T2 magnetization preparation between the inversion pulse and acquisition. The timing parameters of GB-LGE sequence are determined by optimizing a cost-function representing the desired tissue contrast. The proposed 3D GB-LGE sequence was evaluated using phantoms, human subjects (n = 45) and a swine model of myocardial infarction (n = 5). Two independent readers subjectively evaluated the image quality and ability to identify and localize scarring in GB-LGE compared to black-blood LGE (BB-LGE) (i.e., with complete blood nulling) and conventional (bright-blood) LGE. RESULTS: GB-LGE contrast was successfully generated in phantoms and all in-vivo scans. The scar-to-blood contrast was improved in GB-LGE compared to conventional LGE in humans (1.1 ± 0.5 vs. 0.6 ± 0.4, P < 0.001) and in animals (1.5 ± 0.2 vs. -0.03 ± 0.2). In patients, GB-LGE detected more tissue scarring compared to BB-LGE and conventional LGE. The subjective scores of the GB-LGE ability for localizing LV scar and detecting papillary scar were improved as compared with both BB-LGE (P < 0.024) and conventional LGE (P < 0.001). In the swine infarction model, GB-LGE scores for the ability to localize LV scar scores were consistently higher than those of both BB-LGE and conventional-LGE. CONCLUSION: GB-LGE imaging improves the ability to identify and localize myocardial scarring compared to both BB-LGE and conventional LGE. Further studies are warranted to histologically validate GB-LGE.


Asunto(s)
Cicatriz/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Infarto del Miocardio/diagnóstico por imagen , Miocardio/patología , Compuestos Organometálicos/administración & dosificación , Adulto , Anciano , Animales , Cicatriz/patología , Modelos Animales de Enfermedad , Femenino , Humanos , Imagen por Resonancia Magnética/instrumentación , Masculino , Persona de Mediana Edad , Infarto del Miocardio/patología , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sus scrofa , Supervivencia Tisular
5.
J Magn Reson Imaging ; 46(6): 1829-1838, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28301075

RESUMEN

PURPOSE: To evaluate diagnostic image quality of 3D late gadolinium enhancement (LGE) with high isotropic spatial resolution (∼1.4 mm3 ) images reconstructed from randomly undersampled k-space using LOw-dimensional-structure Self-learning and Thresholding (LOST). MATERIALS AND METHODS: We prospectively enrolled 270 patients (181 men; 55 ± 14 years) referred for myocardial viability assessment. 3D LGE with isotropic spatial resolution of 1.4 ± 0.1 mm3 was acquired at 1.5T using a LOST acceleration rate of 3 to 5. In a subset of 121 patients, 3D LGE or phase-sensitive LGE were acquired with parallel imaging with an acceleration rate of 2 for comparison. Two readers evaluated image quality using a scale of 1 (poor) to 4 (excellent) and assessed for scar presence. The McNemar test statistic was used to compare the proportion of detected scar between the two sequences. We assessed the association between image quality and characteristics (age, gender, torso dimension, weight, heart rate), using generalized linear models. RESULTS: Overall, LGE detection proportions for 3D LGE with LOST were similar between readers 1 and 2 (16.30% vs. 18.15%). For image quality, readers gave 85.9% and 80.0%, respectively, for images categorized as good or excellent. Overall proportion of scar presence was not statistically different from conventional 3D LGE (28% vs. 33% [P = 0.17] for reader 1 and 26% vs. 31% [P = 0.37] for reader 2). Increasing subject heart rate was associated with lower image quality (estimated slope = -0.009 (P = 0.001)). CONCLUSION: High-resolution 3D LGE with LOST yields good to excellent image quality in >80% of patients and identifies patients with LV scar at the same rate as conventional 3D LGE. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1829-1838.


Asunto(s)
Medios de Contraste , Gadolinio , Cardiopatías/diagnóstico por imagen , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Corazón/diagnóstico por imagen , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
6.
Magn Reson Med ; 76(3): 888-96, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26418119

RESUMEN

PURPOSE: To develop a heart-rate independent breath-held joint T1 -T2 mapping sequence for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. METHODS: A novel preparation scheme combining both a saturation pulse and T2 -preparation in a single R-R interval is introduced. The time between these two pulses, as well as the duration of the T2 -preparation is varied in each heartbeat, acquiring images with different T1 and T2 weightings, and no magnetization dependence on previous images. Inherently coregistered T1 and T2 maps are calculated from these images. Phantom imaging is performed to compare the proposed maps with spin echo references. In vivo imaging is performed in ten subjects, comparing the accuracy and precision of the proposed technique to existing myocardial T1 and T2 mapping sequences of the same duration. RESULTS: Phantom experiments show that the proposed technique provides accurate quantification of T1 and T2 values over a wide-range (T1 : 260 ms to 1460 ms, T2 : 40 ms to 200 ms). In vivo imaging shows that the proposed sequence quantifies T1 and T2 values similar to a saturation-based T1 mapping and a conventional breath-hold T2 mapping sequence, respectively. CONCLUSION: The proposed sequence allows joint estimation of accurate and coregistered quantitative myocardial T1 and T2 maps in a single breath-hold. Magn Reson Med 76:888-896, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Algoritmos , Técnicas de Imagen Cardíaca/métodos , Ventrículos Cardíacos/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
7.
Magn Reson Med ; 76(2): 555-65, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-26479866

RESUMEN

PURPOSE: To develop and evaluate a free-breathing slice-interleaved T2 mapping sequence by proposing a new slice-selective T2 magnetization preparation (T2 prep) sequence that allows interleaved data acquisition for different slices in subsequent heartbeats. METHODS: We developed a slice-selective T2 prep for myocardial T2 mapping by adding slice-selective gradients to a conventional single-slice T2 prep sequence. In this sequence, five slices are acquired during five consecutive heartbeats, each using a slice-selective T2 prep. The scheme was repeated four times using different T2 prep echo times. We compared the performance of the proposed slice-interleaved T2 mapping sequence and the conventional single-slice T2 mapping sequence in term of accuracy, precision, and reproducibility using phantom experiments and in vivo imaging in 10 healthy subjects. We also evaluated the feasibility of the proposed sequence in 28 patients with cardiovascular disease, and the quality of the maps was scored subjectively. Furthermore, we investigated the impact of through-plane motion by comparing T2 measurements acquired during end-systole versus mid-diastole. RESULTS: T2 measurements using a slice-interleaved T2 mapping sequence were correlated with a spin echo (r(2) = 0.88) and single-slice T2 mapping sequence (r(2) = 0.98). The mean myocardial T2 values were correlated between slice-interleaved (48 ms) and single-slice (51 ms) T2 mapping sequences. Subjective scores of T2 map quality were good to excellent in 81% of the maps in patients. There was no difference in T2 measurements between end-systole versus mid-diastole. CONCLUSIONS: The proposed free-breathing slice-interleaved T2 mapping sequence allows T2 measurements of five left ventricular slices in 20 heartbeats with similar reproducibility and precision as the single-slice T2 mapping sequence but with a four-fold reduction in acquisition time. Magn Reson Med 76:555-565, 2016. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Artefactos , Técnicas de Imagen Sincronizada Cardíacas/métodos , Cardiopatías/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagen por Resonancia Cinemagnética/métodos , Mecánica Respiratoria , Procesamiento de Señales Asistido por Computador , Adulto , Anciano , Algoritmos , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/instrumentación , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
8.
NMR Biomed ; 29(10): 1486-96, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27658506

RESUMEN

Cardiac T1 mapping allows non-invasive imaging of interstitial diffuse fibrosis. Myocardial T1 is commonly calculated by voxel-wise fitting of the images acquired using balanced steady-state free precession (SSFP) after an inversion pulse. However, SSFP imaging is sensitive to B1 and B0 imperfection, which may result in additional artifacts. A gradient echo (GRE) imaging sequence has been used for myocardial T1 mapping; however, its use has been limited to higher magnetic field to compensate for the lower signal-to-noise ratio (SNR) of GRE versus SSFP imaging. A slice-interleaved T1 mapping (STONE) sequence with SSFP readout (STONE-SSFP) has been recently proposed for native myocardial T1 mapping, which allows longer recovery of magnetization (>8 R-R) after each inversion pulse. In this study, we hypothesize that a longer recovery allows higher SNR and enables native myocardial T1 mapping using STONE with GRE imaging readout (STONE-GRE) at 1.5T. Numerical simulations and phantom and in vivo imaging were performed to compare the performance of STONE-GRE and STONE-SSFP for native myocardial T1 mapping at 1.5T. In numerical simulations, STONE-SSFP shows sensitivity to both T2 and off resonance. Despite the insensitivity of GRE imaging to T2 , STONE-GRE remains sensitive to T2 due to the dependence of the inversion pulse performance on T2 . In the phantom study, STONE-GRE had inferior accuracy and precision and similar repeatability as compared with STONE-SSFP. In in vivo studies, STONE-GRE and STONE-SSFP had similar myocardial native T1 times, precisions, repeatabilities and subjective T1 map qualities. Despite the lower SNR of the GRE imaging readout compared with SSFP, STONE-GRE provides similar native myocardial T1 measurements, precision, repeatability, and subjective image quality when compared with STONE-SSFP at 1.5T.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Cardiopatías/diagnóstico por imagen , Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Algoritmos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
J Magn Reson Imaging ; 44(5): 1159-1167, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27043156

RESUMEN

PURPOSE: To assess measurement reproducibility and image quality of myocardial T1 and T2 maps using free-breathing slice-interleaved T1 and T2 mapping sequences at 1.5 Tesla (T). MATERIALS AND METHODS: Eleven healthy subjects (33 ± 16 years; 6 males) underwent a slice-interleaved T1 and T2 mapping test/retest cardiac MR study at 1.5T on 2 days. For each day, subjects were imaged in two sessions with removal out of the magnet and repositioning before the subsequent session. We studied measurement reproducibility as well as the required sample size for sufficient statistical power to detect a predefined change in T1 and T2 . In a separate prospective study, we assessed T1 and T2 map image quality in 241 patients (54 ± 15 years; 73 women) with known/suspected cardiovascular disease referred for clinical cardiac MR. A subjective quality score was used to assess a segment-based image quality. RESULTS: In the healthy cohort, the slice-interleaved T1 measurements were highly reproducible, with global coefficients of variation (CVs) of 2.4% between subjects, 2.1% between days, and 1.7% between sessions. Slice-interleaved T2 mapping sequences provided similar reproducibility with global CVs of 7.2% between subjects, 6.3% between days, and 5.0 between sessions. A lower variability resulted in a reduction of the required number of subjects to achieve a certain statistical power when compared with other T1 mapping sequences. In the subjective image quality assessment, >80% of myocardial segments had interpretable data. CONCLUSION: Slice-interleaved T1 and T2 mapping sequences yield highly reproducible T1 and T2 measurements with >80% of interpretable myocardial segments. J. Magn. Reson. Imaging 2016;44:1159-1167.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Corazón/anatomía & histología , Humanos , Aumento de la Imagen/métodos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Magn Reson Med ; 74(1): 93-105, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25103908

RESUMEN

PURPOSE: To develop an improved T2 prepared (T2 prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T2 mapping. METHODS: Myocardial T2 mapping is commonly performed by acquisition of multiple T2 prep bSSFP images and estimating the voxel-wise T2 values using a two-parameter fit for relaxation. However, a two-parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T2 prep RF pulses, which may decrease the robustness of T2 mapping. Therefore, we propose a novel T2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T2 prep echo time. This enables the robust estimation of T2 maps using a 3-parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T2 maps generated using the proposed 3-parameter model with the conventional two-parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models. RESULTS: Phantom and in vivo data show that the T2 values generated by the proposed 3-parameter model fitting do not change with different choices of the T2 prep echo times, and are not statistically different than the reference values for the phantom (P = 0.10 with three T2 prep echoes). The two-parameter model exhibits dependence on the choice of T2 prep echo times and are significantly different than the reference values (P = 0.01 with three T2 prep echoes). CONCLUSION: The proposed imaging sequence in combination with a three-parameter model allows accurate measurement of myocardial T2 values, which is independent of number and duration of T2 prep echo times. Magn Reson Med 74:93-105, 2015. © 2014 Wiley Periodicals, Inc.

11.
Magn Reson Med ; 74(1): 115-124, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25131652

RESUMEN

PURPOSE: To develop a novel pulse sequence for free-breathing, multislice, native myocardial T1 mapping. METHODS: The slice-interleaved T1 (STONE) sequence consists of multiple sets of single-shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudinal magnetization in the adjacent slices. For respiratory motion, a prospective slice-tracking respiratory navigator is used to decrease through-plane motion followed by a retrospective image registration to reduce in-plane motion. STONE T1 maps were calculated using both a two-parameter and three-parameter fit model. The accuracy and precision of the STONE sequence for different T1 , T2 , and inversion pulse efficiency were studied using numerical simulations and phantom experiments. T1 maps from 14 subjects were acquired with the STONE sequence and T1 s were compared to the MOdified Look-Locker Inversion recovery sequence (MOLLI). RESULTS: In numerical simulations and phantom experiments, the STONE sequence using a two-parameter fit model yields more accurate T1 times compared to MOLLI, with similar high precision. The three-parameter fit model further improves the accuracy, but with a reduced precision. The native myocardial T1 times were higher in the STONE sequence using two- or three-parameter fit compared to MOLLI. The standard deviation of the T1 times was lower in the STONE T1 maps with a two-parameter fit compared with MOLLI or a three-parameter fit. CONCLUSION: The STONE sequence allows accurate and precise quantification of native myocardial T1 times with the additional benefit of covering the entire ventricle. Magn Reson Med 74:115-124, 2015. © 2014 Wiley Periodicals, Inc.

12.
NMR Biomed ; 28(1): 30-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25323208

RESUMEN

The aim of this study was to implement and evaluate an accelerated three-dimensional (3D) cine phase contrast MRI sequence by combining a randomly sampled 3D k-space acquisition sequence with an echo planar imaging (EPI) readout. An accelerated 3D cine phase contrast MRI sequence was implemented by combining EPI readout with randomly undersampled 3D k-space data suitable for compressed sensing (CS) reconstruction. The undersampled data were then reconstructed using low-dimensional structural self-learning and thresholding (LOST). 3D phase contrast MRI was acquired in 11 healthy adults using an overall acceleration of 7 (EPI factor of 3 and CS rate of 3). For comparison, a single two-dimensional (2D) cine phase contrast scan was also performed with sensitivity encoding (SENSE) rate 2 and approximately at the level of the pulmonary artery bifurcation. The stroke volume and mean velocity in both the ascending and descending aorta were measured and compared between two sequences using Bland-Altman plots. An average scan time of 3 min and 30 s, corresponding to an acceleration rate of 7, was achieved for 3D cine phase contrast scan with one direction flow encoding, voxel size of 2 × 2 × 3 mm(3) , foot-head coverage of 6 cm and temporal resolution of 30 ms. The mean velocity and stroke volume in both the ascending and descending aorta were statistically equivalent between the proposed 3D sequence and the standard 2D cine phase contrast sequence. The combination of EPI with a randomly undersampled 3D k-space sampling sequence using LOST reconstruction allows a seven-fold reduction in scan time of 3D cine phase contrast MRI without compromising blood flow quantification.


Asunto(s)
Aceleración , Imagen Eco-Planar/métodos , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética/métodos , Adulto , Aorta/fisiología , Medios de Contraste , Femenino , Humanos , Masculino
13.
J Cardiovasc Magn Reson ; 17: 46, 2015 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-26067275

RESUMEN

BACKGROUND: To evaluate and quantify the impact of a novel image-based motion correction technique in myocardial T2 mapping in terms of measurement reproducibility and spatial variability. METHODS: Twelve healthy adult subjects were imaged using breath-hold (BH), free breathing (FB), and free breathing with respiratory navigator gating (FB + NAV) myocardial T2 mapping sequences. Fifty patients referred for clinical CMR were imaged using the FB + NAV sequence. All sequences used a T2 prepared (T2prep) steady-state free precession acquisition. In-plane myocardial motion was corrected using an adaptive registration of varying contrast-weighted images for improved tissue characterization (ARCTIC). DICE similarity coefficient (DSC) and myocardial boundary errors (MBE) were measured to quantify the motion estimation accuracy in healthy subjects. T2 mapping reproducibility and spatial variability were evaluated in healthy subjects using 5 repetitions of the FB + NAV sequence with either 4 or 20 T2prep echo times (TE). Subjective T2 map quality was assessed in patients by an experienced reader using a 4-point scale (1-non diagnostic, 4-excellent). RESULTS: ARCTIC led to increased DSC in BH data (0.85 ± 0.08 vs. 0.90 ± 0.02, p = 0.007), FB data (0.78 ± 0.13 vs. 0.90 ± 0.21, p < 0.001), and FB + NAV data (0.86 ± 0.05 vs. 0.90 ± 0.02, p = 0.002), and reduced MBE in BH data (0.90 ± 0.40 vs. 0.64 ± 0.19 mm, p = 0.005), FB data (1.21 ± 0.65 vs. 0.63 ± 0.10 mm, p < 0.001), and FB + NAV data (0.81 ± 0.21 vs. 0.63 ± 0.08 mm, p < 0.001). Improved reproducibility (4TE: 5.3 ± 2.5 ms vs. 4.0 ± 1.5 ms, p = 0.016; 20TE: 3.9 ± 2.3 ms vs. 2.2 ± 0.5 ms, p = 0.002), reduced spatial variability (4TE: 12.8 ± 3.5 ms vs. 10.3 ± 2.5 ms, p < 0.001; 20TE: 9.7 ± 3.5 ms vs. 7.5 ± 1.4 ms) and improved subjective score of T2 map quality (3.43 ± 0.79 vs. 3.69 ± 0.55, p < 0.001) were obtained using ARCTIC. CONCLUSIONS: The ARCTIC technique substantially reduces spatial mis-alignment among T2-weighted images and improves the reproducibility and spatial variability of in-vivo T2 mapping.


Asunto(s)
Contencion de la Respiración , Corazón/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Miocardio , Respiración , Adolescente , Adulto , Artefactos , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Movimiento , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Adulto Joven
14.
Magn Reson Med ; 71(2): 815-22, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23440946

RESUMEN

PURPOSE: To enable accelerated isotropic sub-millimeter whole-heart coronary MRI within a 6-min acquisition and to compare this with a current state-of-the-art accelerated imaging technique at acceleration rates beyond what is used clinically. METHODS: Coronary MRI still faces major challenges, including lengthy acquisition time, low signal-to-noise-ratio (SNR), and suboptimal spatial resolution. Higher spatial resolution in the sub-millimeter range is desirable, but this results in increased acquisition time and lower SNR, hindering its clinical implementation. In this study, we sought to use an advanced B1-weighted compressed sensing technique for highly accelerated sub-millimeter whole-heart coronary MRI, and to compare the results to parallel imaging, the current-state-of-the-art, where both techniques were used at acceleration rates beyond what is used clinically. Two whole-heart coronary MRI datasets were acquired in seven healthy adult subjects (30.3 ± 12.1 years; 3 men), using prospective 6-fold acceleration, with random undersampling for the proposed compressed sensing technique and with uniform undersampling for sensitivity encoding reconstruction. Reconstructed images were qualitatively compared in terms of image scores and perceived SNR on a four-point scale (1 = poor, 4 = excellent) by an experienced blinded reader. RESULTS: The proposed technique resulted in images with clear visualization of all coronary branches. Overall image quality and perceived SNR of the compressed sensing images were significantly higher than those of parallel imaging (P = 0.03 for both), which suffered from noise amplification artifacts due to the reduced SNR. CONCLUSION: The proposed compressed sensing-based reconstruction and acquisition technique for sub-millimeter whole-heart coronary MRI provides 6-fold acceleration, where it outperforms parallel imaging with uniform undersampling.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Vasos Coronarios/anatomía & histología , Compresión de Datos/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Algoritmos , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Magn Reson Med ; 71(6): 2172-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23900942

RESUMEN

PURPOSE: To investigate the efficacy of a novel respiratory motion scheme, where only the center of k-space is gated using respiratory navigators, versus a fully respiratory-gated acquisition for three-dimensional flow imaging. METHODS: Three-dimensional flow images were acquired axially using a gradient echo sequence in a volume, covering the ascending and descending aorta, and the pulmonary artery bifurcation in 12 healthy subjects (33.2 ± 15.8 years; five men). For respiratory motion compensation, two gating and tracking strategies were used with a 7-mm gating window: (1) All of k-space acquired within the gating window (fully gated) and (2) central k-space acquired within the gating window, and the remainder of k-space acquired without any gating (center gated). Each scan was repeated twice. Stroke volume, mean flow, peak velocity, and signal-to-noise-ratio measurements were performed both on the ascending and on the descending aorta for all acquisitions, which were compared using a linear mixed-effects model and Bland-Altman analysis. RESULTS: There were no statistical differences between the fully gated and the center-gated strategies for the quantification of stroke volume, peak velocity, and mean flow, as well as the signal-to-noise-ratio measurements. Furthermore, the proposed center-gated strategy had significantly shorter acquisition time compared to the fully gated strategy (13:19 ± 3:02 vs. 19:35 ± 5:02, P < 0.001). CONCLUSIONS: The proposed novel center-gated strategy for three-dimensional flow MRI allows for markedly shorter acquisition time without any systematic variation in quantitative flow measurements in this small group of healthy volunteers.


Asunto(s)
Aorta Torácica/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Imagen por Resonancia Magnética/métodos , Arteria Pulmonar/fisiología , Adulto , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Masculino , Movimiento (Física) , Respiración , Relación Señal-Ruido , Factores de Tiempo
16.
Magn Reson Med ; 72(3): 629-39, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24123058

RESUMEN

PURPOSE: To develop and evaluate an image reconstruction technique for cardiac MRI (CMR) perfusion that uses localized spatio-temporal constraints. METHODS: CMR perfusion plays an important role in detecting myocardial ischemia in patients with coronary artery disease. Breath-hold k-t-based image acceleration techniques are typically used in CMR perfusion for superior spatial/temporal resolution and improved coverage. In this study, we propose a novel compressed sensing-based image reconstruction technique for CMR perfusion, with applicability to free-breathing examinations. This technique uses local spatio-temporal constraints by regularizing image patches across a small number of dynamics. The technique was compared with conventional dynamic-by-dynamic reconstruction, and sparsity regularization using a temporal principal-component (pc) basis, as well as zero-filled data in multislice two-dimensional (2D) and three-dimensional (3D) CMR perfusion. Qualitative image scores were used (1 = poor, 4 = excellent) to evaluate the technique in 3D perfusion in 10 patients and five healthy subjects. On four healthy subjects, the proposed technique was also compared with a breath-hold multislice 2D acquisition with parallel imaging in terms of signal intensity curves. RESULTS: The proposed technique produced images that were superior in terms of spatial and temporal blurring compared with the other techniques, even in free-breathing datasets. The image scores indicated a significant improvement compared with other techniques in 3D perfusion (x-pc regularization, 2.8 ± 0.5 versus 2.3 ± 0.5; dynamic-by-dynamic, 1.7 ± 0.5; zero-filled, 1.1 ± 0.2). Signal intensity curves indicate similar dynamics of uptake between the proposed method with 3D acquisition and the breath-hold multislice 2D acquisition with parallel imaging. CONCLUSION: The proposed reconstruction uses sparsity regularization based on localized information in both spatial and temporal domains for highly accelerated CMR perfusion with potential use in free-breathing 3D acquisitions.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Isquemia Miocárdica/diagnóstico , Adulto , Algoritmos , Contencion de la Respiración , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Femenino , Humanos , Imagenología Tridimensional , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos
17.
Magn Reson Med ; 72(3): 689-98, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24123153

RESUMEN

PURPOSE: To develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise. METHODS: We propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence. RESULTS: The proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy. CONCLUSION: The proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans.


Asunto(s)
Enfermedades Cardiovasculares/fisiopatología , Ejercicio Físico/fisiología , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias , Adulto , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Mecánica Respiratoria
18.
Magn Reson Med ; 72(3): 850-7, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24186772

RESUMEN

PURPOSE: To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. METHODS: Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 × 320 × 100 mm(3) , resolution = 1.6 × 1.6 × 5.0 mm(3) , acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. RESULTS: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35 ± 11 s to 58 ± 21 s; P < 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P > 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85 ± 22 s to 35 ± 6 s; P < 0.001). CONCLUSIONS: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV.


Asunto(s)
Contencion de la Respiración , Hiperventilación , Imagenología Tridimensional/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos/administración & dosificación , Oxígeno/administración & dosificación , Adulto , Artefactos , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste/administración & dosificación , Estudios de Factibilidad , Femenino , Voluntarios Sanos , Humanos , Masculino , Meglumina/administración & dosificación
19.
J Cardiovasc Magn Reson ; 16: 91, 2014 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-25416082

RESUMEN

BACKGROUND: To investigate the feasibility of accelerated electrocardiogram (ECG)-triggered contrast enhanced pulmonary vein magnetic resonance angiography (CE-PV MRA) with isotropic spatial resolution using compressed sensing (CS). METHODS: Nineteen patients (59±13 y, 11 M) referred for MR were scanned using the proposed accelerated free breathing ECG-triggered 3D CE-PV MRA sequence (FOV=340×340×110 mm3, spatial resolution=1.5×1.5×1.5 mm3, acquisition window=140 ms at mid diastole and CS acceleration factor=5) and a conventional first-pass breath-hold non ECG-triggered 3D CE-PV MRA sequence. CS data were reconstructed offline using low-dimensional-structure self-learning and thresholding reconstruction (LOST) CS reconstruction. Quantitative analysis of PV sharpness and subjective qualitative analysis of overall image quality were performed using a 4-point scale (1: poor; 4: excellent). RESULTS: Quantitative PV sharpness was increased using the proposed approach (0.73±0.09 vs. 0.51±0.07 for the conventional CE-PV MRA protocol, p<0.001). There were no significant differences in the subjective image quality scores between the techniques (3.32±0.94 vs. 3.53±0.77 using the proposed technique). CONCLUSIONS: CS-accelerated free-breathing ECG-triggered CE-PV MRA allows evaluation of PV anatomy with improved sharpness compared to conventional non-ECG gated first-pass CE-PV MRA. This technique may be a valuable alternative for patients in which the first pass CE-PV MRA fails due to inaccurate first pass timing or inability of the patient to perform a 20-25 seconds breath-hold.


Asunto(s)
Fibrilación Atrial/diagnóstico , Técnicas de Imagen Sincronizada Cardíacas , Electrocardiografía , Frecuencia Cardíaca , Angiografía por Resonancia Magnética/métodos , Flebografía/métodos , Venas Pulmonares/patología , Frecuencia Respiratoria , Anciano , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Contencion de la Respiración , Ablación por Catéter , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Venas Pulmonares/cirugía , Factores de Tiempo , Resultado del Tratamiento
20.
Radiographics ; 34(6): 1636-57, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25310421

RESUMEN

Coronary microcirculatory dysfunction has a fundamental role in the pathophysiology of ischemic coronary artery disease (CAD) as well as various other cardiovascular disorders. Invasive coronary angiography remains the standard of reference for diagnosis of CAD. Nevertheless, it has been well acknowledged that the degree of luminal narrowing of epicardial coronary lesions detected at angiography is a poor predictor of the functional severity of the lesion. Recent studies demonstrate that assessment of coronary microcirculatory function by means of noninvasive myocardial perfusion imaging helps increase diagnostic accuracy and guide medical decision-making. Among available diagnostic modalities, cardiac magnetic resonance (MR) perfusion imaging has evolved to become a reliable and robust tool providing accurate quantitative assessment of regional myocardial perfusion. Owing to its high spatial resolution, noninvasive nature, and absence of ionizing radiation, cardiac MR perfusion imaging has improved detection of clinically relevant CAD. It has also offered further insights into the understanding of various cardiovascular disorders resulting from coronary microvascular dysfunction in the absence of proximal flow-limiting CAD. Cardiac MR perfusion imaging is now routinely used in many centers and shows promise in evaluating patients with disorders beyond those of the epicardial coronary circulation. Recent implementation of high-field-strength magnets and rapid acquisition techniques have further contributed to expanding the role of cardiac MR perfusion imaging to include novel promising applications. In this article, we provide an overview of cardiac MR perfusion imaging, including techniques, image analysis, and clinical applications.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/fisiopatología , Circulación Coronaria/fisiología , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA