RESUMEN
Electroporation (EP) is one of the successful physical methods for intracellular drug delivery, which temporarily permeabilizes plasma membrane by exposing cells to electric pulses. Orientation of cells in electric field is important for electroporation and, consequently, for transport of molecules through permeabilized plasma membrane. Uptake of molecules after electroporation are the greatest at poles of cells facing electrodes and is often asymmetrical. However, asymmetry reported was inconsistent and inconclusive-in different reports it was either preferentially anodal or cathodal. We investigated the asymmetry of polar uptake of calcium ions after electroporation with electric pulses of different durations, as the orientation of elongated cells affects electroporation to a different extent when using electric pulses of different durations in the range of 100 ns to 100 µs. The results show that with 1, 10, and 100 µs pulses, the uptake of calcium ions is greater at the pole closer to the cathode than at the pole closer to the anode. With shorter 100 ns pulses, the asymmetry is not observed. A different extent of electroporation at different parts of elongated cells, such as muscle or cardiac cells, may have an impact on electroporation-based treatments such as drug delivery, pulse-field ablation, and gene electrotransfection.
Asunto(s)
Membrana Celular/metabolismo , Electroporación , Proteínas de Transporte de Membrana/metabolismo , Mioblastos Cardíacos/metabolismo , Animales , Transporte Biológico , Células Cultivadas , Mioblastos Cardíacos/citología , RatasRESUMEN
Polymersomes, vesicles composed of block copolymers, are promising candidates as membrane alternatives and functional containers, e.g., as potential carriers for functional molecules because of their stability and tunable membrane properties. In the scope of possible use for membrane protein delivery to cells by electrofusion, we investigated the cytotoxicity of such polymersomes as well as the effects of nanosecond electric pulses with variable repetition rate on the shape and permeability of polymersomes in buffers with different conductivities. The polymersomes did not show cytotoxic effects to CHO and B16-F1 cells in vitro in concentrations up to 250 µg/mL (for 48 h) or 1.35 mg/mL (for 60 min), which renders them suitable for interacting with living cells. We observed a significant effect of the pulse repetition rate on electrodeformation of the polymersomes. The electrodeformation was most pronounced in low conductivity buffer, which is favorable for performing electrofusion with cells. However, despite more pronounced deformation at higher pulse repetition rate, the electroporation performance of polymersomes was unaffected and remained in similar ranges both at 10 Hz and 10 kHz. This phenomenon is possibly due to the higher stability and rigidity of polymer vesicles, compared to liposomes, and can serve as an advantage (or disadvantage) depending on the aim in employing polymersomes such as stable membrane alternative architectures or drug vehicles.
Asunto(s)
Permeabilidad de la Membrana Celular , Membrana Celular/metabolismo , Sistemas de Liberación de Medicamentos/métodos , Electroquimioterapia/métodos , Animales , Células CHO , Cricetulus , RatonesRESUMEN
Excitable cells such as neuronal and muscle cells can be primary targets in rapidly emerging electroporation-based treatments. However, they can be affected by electric pulses even in therapies where they are not the primary targets, and this can cause adverse side effects. Therefore, to optimize the electroporation-based treatments of excitable and non-excitable tissues, there is a need to study the effects of electric pulses on excitable cells, their ion channels, and excitability in vitro. For this purpose, a protocol was developed for optical monitoring of changes in action potential generation due to electroporation on a simple excitable cell model of genetically engineered tet-on spiking HEK cells. With the use of a fluorescent potentiometric dye, the changes in transmembrane voltage were monitored under a fluorescence microscope, and relevant parameters of cell responses were extracted automatically with a MATLAB application. This way, the excitable cell responses to different electric pulses and the interplay between excitation and electroporation could be efficiently evaluated.
Asunto(s)
Potenciales de Acción , Electroporación , Electroporación/métodos , Humanos , Células HEK293 , Potenciales de Acción/fisiología , Ingeniería Genética/métodos , Microscopía Fluorescente/métodos , Colorantes Fluorescentes/químicaRESUMEN
Electric pulses used in electroporation-based treatments have been shown to affect the excitability of muscle and neuronal cells. However, understanding the interplay between electroporation and electrophysiological response of excitable cells is complex, since both ion channel gating and electroporation depend on dynamic changes in the transmembrane voltage (TMV). In this study, a genetically engineered human embryonic kidney cells expressing NaV1.5 and Kir2.1, a minimal complementary channels required for excitability (named S-HEK), was characterized as a simple cell model used for studying the effects of electroporation in excitable cells. S-HEK cells and their non-excitable counterparts (NS-HEK) were exposed to 100 µs pulses of increasing electric field strength. Changes in TMV, plasma membrane permeability, and intracellular Ca2+ were monitored with fluorescence microscopy. We found that a very mild electroporation, undetectable with the classical propidium assay but associated with a transient increase in intracellular Ca2+, can already have a profound effect on excitability close to the electrostimulation threshold, as corroborated by multiscale computational modelling. These results are of great relevance for understanding the effects of pulse delivery on cell excitability observed in context of the rapidly developing cardiac pulsed field ablation as well as other electroporation-based treatments in excitable tissues.
Asunto(s)
Terapia Conductista , Electroporación , Humanos , Bioensayo , Permeabilidad de la Membrana Celular , Simulación por ComputadorRESUMEN
Gene electrotransfection using micro- or millisecond electric pulses is a well-established method for safe gene transfer. For efficient transfection, plasmid DNA has to reach the nucleus. Shorter, high-intensity nanosecond electric pulses (nsEPs) affect internal cell membranes and may contribute to an increased uptake of plasmid by the nucleus. In our study, nsEPs were applied to Chinese hamster ovary (CHO) cells after classical gene electrotransfer, using micro- or millisecond pulses with a plasmid coding the green fluorescent protein (GFP). Time gaps between classical gene electrotransfer and nsEPs were varied (0.5, 2, 6 and 24 h) and three different nsEP parameters were used: 18 ns-10 kV/cm, 10 ns-40 kV/cm and 15 ns-60 kV/cm. Results analyzed by either fluorescence microscopy or flow cytometry showed that neither the percentage of electrotransfected cells nor the amount of GFP expressed was increased by nsEP. All nsEP parameters also had no effects on GFP fluorescence intensity of human colorectal tumor cells (HCT-116) with constitutive expression of GFP. We thus conclude that nsEPs have no major contribution to gene electrotransfer in CHO cells and no effect on constitutive GFP expression in HCT-116 cells.
Asunto(s)
Expresión Génica , Proteínas Fluorescentes Verdes/genética , Animales , Células CHO , Permeabilidad de la Membrana Celular , Cricetinae , Cricetulus , Estimulación Eléctrica , Electroporación , Proteínas Fluorescentes Verdes/biosíntesis , Células HCT116 , Humanos , Membrana Nuclear/metabolismo , Factores de Tiempo , TransfecciónRESUMEN
Electroporation is a biophysical phenomenon involving an increase in cell membrane permeability to molecules after a high-pulsed electric field is applied to the tissue. Currently, electroporation is being developed for non-thermal ablation of cardiac tissue to treat arrhythmias. Cardiomyocytes have been shown to be more affected by electroporation when oriented with their long axis parallel to the applied electric field. However, recent studies demonstrate that the preferentially affected orientation depends on the pulse parameters. To gain better insight into the influence of cell orientation on electroporation with different pulse parameters, we developed a time-dependent nonlinear numerical model where we calculated the induced transmembrane voltage and pores creation in the membrane due to electroporation. The numerical results show that the onset of electroporation is observed at lower electric field strengths for cells oriented parallel to the electric field for pulse durations ≥10 µs, and cells oriented perpendicular for pulse durations ~100 ns. For pulses of ~1 µs duration, electroporation is not very sensitive to cell orientation. Interestingly, as the electric field strength increases beyond the onset of electroporation, perpendicular cells become more affected irrespective of pulse duration. The results obtained using the developed time-dependent nonlinear model are corroborated by in vitro experimental measurements. Our study will contribute to the process of further development and optimization of pulsed-field ablation and gene therapy in cardiac treatments.
Asunto(s)
Electroporación , Dinámicas no Lineales , Electroporación/métodos , Terapia de Electroporación , Electricidad , Permeabilidad de la Membrana CelularRESUMEN
Nanosecond, high-voltage electric pulses (nsEP) induce permeabilization of the plasma membrane and the membranes of cell organelles, leading to various responses in cells including cytochrome c release from mitochondria and caspase activation associated with apoptosis. We report here evidence for nsEP-induced permeabilization of mitochondrial membranes in living cells. Using three different methods with fluorescence indicators-rhodamine 123 (R123), tetramethyl rhodamine ethyl ester (TMRE), and cobalt-quenched calcein-we have shown that multiple nsEP (five pulses or more, 4 ns duration, 10 MV/m, 1 kHz repetition rate) cause an increase of the inner mitochondrial membrane permeability and an associated loss of mitochondrial membrane potential. These effects could be a consequence of nsEP permeabilization of the inner mitochondrial membrane or the activation of mitochondrial membrane permeability transition pores. Plasma membrane permeabilization (YO-PRO-1 influx) was detected in addition to mitochondrial membrane permeabilization.
Asunto(s)
Electricidad , Potencial de la Membrana Mitocondrial/fisiología , Benzoxazoles , Permeabilidad de la Membrana Celular , Fluoresceínas , Humanos , Células Jurkat , Compuestos Organometálicos , Compuestos de Quinolinio , Rodamina 123RESUMEN
BACKGROUND: Irreversible electroporation is an energy form utilizing high-voltage pulsed electric field, leading to cellular homeostasis disruption and cell death. Recently, irreversible electroporation has shown promising results for the treatment of cardiac arrhythmias. However, reversible and irreversible effects of pulsed electric field on cardiac myocytes remain poorly understood. Here, we evaluated the influence of a monophasic single electric pulse (EP) on the contractility, Ca2+ homeostasis and recovery of cardiac myocytes. METHODS: Isolated rat left ventricular myocytes were electroporated using single monophasic EP of different durations and voltages. Sarcomere length and intracellular Ca2+ were simultaneously monitored for up to 20 minutes after EP application in Fura-2 loaded left ventricular myocytes. Lethal voltage thresholds were determined using 100 µs and 10 ms pulses and by discriminating cell orientation with respect to the electric field. RESULTS: Electroporation led to an immediate increase in intracellular Ca2+ which was dependent upon the voltage delivered to the cell. Intermediate-voltage EP (140 V, 100 µs) increased sarcomere shortening, Ca2+ transient amplitude, and diastolic Ca2+ level measured 1 minute post-EP. Although sarcomere shortening returned to pre-EP level within 5 minutes, Ca2+ transient amplitude decreased further below pre-EP level and diastolic Ca2+ level remained elevated within 20 minutes post-EP. Spontaneous contractions were observed after sublethal EP application but their frequency decreased progressively within 20 minutes. Lethal EP voltage threshold was lower in myocytes oriented perpendicular than parallel to the electric field using 100 µs pulses while an opposite effect was found using 10 ms pulses. CONCLUSIONS: Sublethal EP affected rat left ventricular myocytes contractility and disrupted Ca2+ homeostasis as a function of the EP voltage. Moreover, EP-induced lethality was preceded by a large increase in intracellular Ca2+ and was dependent upon the EP duration, amplitude and left ventricular myocytes orientation with respect to the electric field. These findings provide new insights into the effect of pulsed electric field on cardiac myocytes.
Asunto(s)
Calcio , Miocitos Cardíacos , Ratas , Animales , Miocitos Cardíacos/metabolismo , Calcio/metabolismo , Ventrículos Cardíacos/metabolismo , Electroporación , HomeostasisRESUMEN
Exposure of cells to high voltage electric pulses increases transiently membrane permeability through membrane electroporation. Electroporation can be reversible and is used in gene transfer and enhanced drug delivery but can also lead to cell death. Electroporation resulting in cell death (termed as irreversible electroporation) has been successfully used as a new non-thermal ablation method of soft tissue such as tumours or arrhythmogenic heart tissue. Even though the mechanisms of cell death can influence the outcome of electroporation-based treatments due to use of different electric pulse parameters and conditions, these are not elucidated yet. We review the mechanisms of cell death after electroporation reported in literature, cell injuries that may lead to cell death after electroporation and membrane repair mechanisms involved. The knowledge of membrane repair and cell death mechanisms after cell exposure to electric pulses, targets of electric field in cells need to be identified to optimize existing and develop of new electroporation-based techniques used in medicine, biotechnology, and food technology.
Asunto(s)
Muerte Celular , Electroporación/métodos , AnimalesRESUMEN
In gene electrotransfer and cardiac ablation with irreversible electroporation, treated muscle cells are typically of elongated shape and their orientation may vary. Orientation of cells in electric field has been reported to affect electroporation, and hence electrodes placement and pulse parameters choice in treatments for achieving homogeneous effect in tissue is important. We investigated how cell orientation influences electroporation with respect to different pulse durations (ns to ms range), both experimentally and numerically. Experimentally detected electroporation (evaluated separately for cells parallel and perpendicular to electric field) via Ca2+ uptake in H9c2 and AC16 cardiomyocytes was numerically modeled using the asymptotic pore equation. Results showed that cell orientation affects electroporation extent: using short, nanosecond pulses, cells perpendicular to electric field are significantly more electroporated than parallel (up to 100-times more pores formed), and with long, millisecond pulses, cells parallel to electric field are more electroporated than perpendicular (up to 1000-times more pores formed). In the range of a few microseconds, cells of both orientations were electroporated to the same extent. Using pulses of a few microseconds lends itself as a new possible strategy in achieving homogeneous electroporation in tissue with elongated cells of different orientation (e.g. electroporation-based cardiac ablation).
Asunto(s)
Forma de la Célula/fisiología , Electroporación/métodos , Animales , Línea Celular , Movimiento Celular/fisiología , Fura-2/química , Humanos , Microscopía Fluorescente , Miocitos Cardíacos/citología , RatasRESUMEN
Pulsed electric fields (PEFs) can be used to transiently increase cell membrane permeability in procedures ranging from gene therapy to tumor eradication. Although very efficient, PEF-based therapies generally require the use of invasive electrodes, which cause pain and tissue damage. An emerging noninvasive, contactless alternative to PEFs are High Intensity Pulsed Electromagnetic Fields (HI-PEMF), whereby the electric field inside the tissue is induced remotely by external pulsed magnetic field. However, one of the current major drawbacks of HI-PEMFs is their inferior efficiency compared to PEFs. In this study we present the proof-of-concept that by adding highly conductive 5 and 20 nm gold nanoparticles (Au NPs), we can significantly potentiate the permeabilizing effect of HI-PEMFs, making it possible to permeabilize up to 80% of the cells with minimal or no effect on cell survival, compared to negligible percentage of permeabilized cells using HI-PEMF alone. Experiments, conducted on Chinese Hamster Ovary cells and Escherichia coli, suggest that Au NPs act as distributed nanoelectrodes, locally enhancing the electric field induced at the plasma membrane. Our findings open up an avenue of possibilities for combining naked as well as functionalized Au NPs with HI-PEMFs for noninvasive, remotely controlled smart drug delivery applications.
Asunto(s)
Electrodos , Campos Electromagnéticos , Electroporación/métodos , Nanotecnología , Animales , Células CHO , Cricetulus , Bacterias Gramnegativas/metabolismoRESUMEN
Exposing cells to an electric field leads to electroporation of the cell membrane which has already been explored and used in a number of applications in medicine and food biotechnology (e.g. electrochemotherapy, gene electrotransfer, extraction of biomolecules). The extent of electroporation depends on several conditions, including pulse parameters, types of cells and tissues, surrounding media, temperature etc. Each application requires a specific level of electroporation, so it must be explored in advance by employing methods for detecting electroporation. Electroporation detection is most often done by measuring increased transport of molecules across the membrane, into or out of the cell. We review here various methods of electroporation detection, together with their advantages and disadvantages. Electroporation detection can be carried out by using dyes (fluorophores or colour stains) or functional molecules, by measuring the efflux of biomolecules, by impedance measurements and voltage clamp techniques as well as by monitoring cell swelling. This review describes methods of detecting cell membrane electroporation in order to help researchers choose the most suitable ones for their specific experiments, considering available equipment and experimental conditions.
Asunto(s)
Permeabilidad de la Membrana Celular , Electroporación/métodos , Animales , Membrana Celular/metabolismo , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Electroporación/instrumentación , Diseño de Equipo , Colorantes Fluorescentes/análisis , Colorantes Fluorescentes/metabolismo , Humanos , Microscopía Fluorescente/instrumentación , Microscopía Fluorescente/métodos , Imagen Óptica/instrumentación , Imagen Óptica/métodosRESUMEN
For this systematic review, 203 published reports on effects of electroporation using nanosecond high-voltage electric pulses (nsEP) on eukaryotic cells (human, animal, plant) in vitro were analyzed. A field synopsis summarizes current published data in the field with respect to publication year, cell types, exposure configuration, and pulse duration. Published data were analyzed for effects observed in eight main target areas (plasma membrane, intracellular, apoptosis, calcium level and distribution, survival, nucleus, mitochondria, stress) and an additional 107 detailed outcomes. We statistically analyzed effects of nsEP with respect to three pulse duration groups: A: 1-10ns, B: 11-100ns and C: 101-999ns. The analysis confirmed that the plasma membrane is more affected with longer pulses than with short pulses, seen best in uptake of dye molecules after applying single pulses. Additionally, we have reviewed measurements of nsEP and evaluations of the electric fields to which cells were exposed in these reports, and we provide recommendations for assessing nanosecond pulsed electric field effects in electroporation studies.
Asunto(s)
Electricidad , Células Eucariotas , Animales , Células Eucariotas/citología , Humanos , Estadística como AsuntoRESUMEN
Blumlein generators are used in different applications such as radars, lasers, and also recently in various biomedical studies, where the effects of high-voltage nanosecond pulses on biological cells are evaluated. In these studies, it was demonstrated that by applying high-voltage nanosecond pulses to cells, plasma membrane and cell organelles are permeabilized. As suggested in a recent publication, the repetition rate and polarity of nanosecond high-voltage pulses could have an important effect on the electropermeabilization process, and consequently, on the observed phenomena. Therefore, we designed a new Blumlein configuration that enables a higher repetition rate of variable duration of either bipolar or unipolar high-voltage pulses. We achieved a maximal pulse repetition rate of 1.1 MHz. However, theoretically, this rate could be even higher. We labeled endocytotic vesicles with lucifer yellow and added propidium iodide to a cell suspension for testing the cell plasma membrane integrity, so we were able to observe the permeabilization of endocytotic vesicles and the cell plasma membrane at the same time. The new design of pulse generator was built, verified, and also tested in experiments. The resulting flexibility and variability allow further in vitro experiments to determine the importance of the pulse repetition rate and pulse polarity on membrane permeabilization -- both of the cell plasma membrane as well as of cell organelle membranes.
Asunto(s)
Permeabilidad de la Membrana Celular/fisiología , Electroporación/instrumentación , Electroporación/métodos , Vesículas Transportadoras/fisiología , Animales , Línea Celular Tumoral , Membrana Celular/fisiología , Simulación por Computador , Isoquinolinas , Melanoma Experimental/fisiopatología , Ratones , Orgánulos/fisiología , PropidioRESUMEN
Molecules regulating cell death constitute prominent therapeutic targets. The pro-apoptotic role of serine protease inhibitors prompted us to search for novel modulators of this process. We have tested some recently synthesized antithrombotic compounds for their potential to induce apoptotic cell death. Cell based analyses revealed that inhibitors built on the azaphenylalanine scaffold are, for B-cell lymphoma cells, severely cytotoxic, while other compounds tested were moderate or non-cytotoxic. These inhibitors induced the time and concentration dependent biochemical and morphological characteristics of apoptosis, such as DEVDase activation, loss of mitochondrial membrane potential, nuclear degradation and genomic DNA fragmentation. Most of the inhibitors proved to be selective for thrombin, with inhibition constants (K(i)) in the nanomolar range. However, they could also inhibit at least one additional serine protease (trypsin, chymotrypsin and/or coagulation factor X) with K(i) values in the nanomolar or low micromolar range. These serine protease inhibitors constitute novel apoptosis inducing compounds in B-cell lymphoma cells.