RESUMEN
BACKGROUND: Studies have shown that data collection by medical record abstraction (MRA) is a significant source of error in clinical research studies relying on secondary use data. Yet, the quality of data collected using MRA is seldom assessed. We employed a novel, theory-based framework for data quality assurance and quality control of MRA. The objective of this work is to determine the potential impact of formalized MRA training and continuous quality control (QC) processes on data quality over time. METHODS: We conducted a retrospective analysis of QC data collected during a cross-sectional medical record review of mother-infant dyads with Neonatal Opioid Withdrawal Syndrome. A confidence interval approach was used to calculate crude (Wald's method) and adjusted (generalized estimating equation) error rates over time. We calculated error rates using the number of errors divided by total fields ("all-field" error rate) and populated fields ("populated-field" error rate) as the denominators, to provide both an optimistic and a conservative measurement, respectively. RESULTS: On average, the ACT NOW CE Study maintained an error rate between 1% (optimistic) and 3% (conservative). Additionally, we observed a decrease of 0.51 percentage points with each additional QC Event conducted. CONCLUSIONS: Formalized MRA training and continuous QC resulted in lower error rates than have been found in previous literature and a decrease in error rates over time. This study newly demonstrates the importance of continuous process controls for MRA within the context of a multi-site clinical research study.
Asunto(s)
Exactitud de los Datos , Registros Médicos , Recolección de Datos , Humanos , Recién Nacido , Proyectos de Investigación , Estudios RetrospectivosRESUMEN
OBJECTIVES: To compare serum ferritin and RET-He values among extremely low gestational age neonates ELGANs with other markers of iron-deficient erythropoiesis. STUDY DESIGN: This is a secondary analysis of the NICHD Darbepoetin Trial. Study data from placebo recipients who had a serum ferritin, a RET-He, and a mean corpuscular volume (MCV) measurement within a 24-hour period were analyzed for correlation. RESULTS: Mixed linear regression models showed no association between ferritin and RET-He at both early (ß = 0.0016, p = 0.40) and late (ß = -0.0001, p = 0.96) time points. Positive associations were observed between RET-He and MCV at baseline, early, and late time points (p < 0.01, =0.01, <0.001, respectively), while ferritin was not associated with MCV at any time point. CONCLUSIONS: Our study shows that RET-He is better correlated with MCV as a marker of iron-limited erythropoiesis than ferritin. The results suggest that ferritin is limited as a marker of iron sufficiency in premature infants. STUDY IDENTIFICATION: FDA IND Number 100138; ClinicalTrials.gov number NCT03169881; NRN ID number NICHD-NRN-0058 (Darbe).