Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sensors (Basel) ; 24(11)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38894235

RESUMEN

This study investigated the reliability of measuring the median nerve cross-sectional area (CSA) at the carpal tunnel inlet using a handheld ultrasound device (HUD) compared to a standard ultrasound system, focusing on intra- and inter-operator reproducibility among novice and expert operators. Employing a prospective cross-sectional design, 37 asymptomatic adults were assessed using both devices, with measurements taken by an expert with over five years of experience and a novice with less than six months. The CSA was determined using manual tracing and ellipse methods, with reproducibility evaluated through intraclass correlation coefficients (ICCs) and agreement assessed via Bland-Altman plots. Results showed a high degree of agreement between the devices, with excellent intra-operator reproducibility (ICC > 0.80) for the expert, and moderate reproducibility for the novice (ICCs ranging from 0.539 to 0.841). Inter-operator reliability was generally moderate, indicating acceptable consistency across different experience levels. The study concludes that HUDs are comparable to standard ultrasound systems for assessing median nerve CSA in asymptomatic subjects, with both devices providing reliable measurements. This supports the use of HUDs in diverse clinical environments, particularly where access to traditional ultrasound is limited. Further research with a larger sample and symptomatic patients is recommended to validate these findings.


Asunto(s)
Nervio Mediano , Ultrasonografía , Humanos , Nervio Mediano/diagnóstico por imagen , Ultrasonografía/métodos , Masculino , Femenino , Adulto , Reproducibilidad de los Resultados , Estudios Transversales , Persona de Mediana Edad , Estudios Prospectivos , Síndrome del Túnel Carpiano/diagnóstico por imagen
4.
Radiol Case Rep ; 19(5): 1671-1673, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38384699

RESUMEN

Bowler's thumb is an uncommon traumatic neuropathy of the thumb ulnar digital nerve. We present a case of bowler's thumb in an individual who is an avid bowler, however, only manifesting following an unrelated injury. We describe the clinical and imaging findings, differential diagnostic considerations, and the treatment options. Knowledge of this entity and its sonographic features is important in order to identify this uncommon entity.

5.
Medicine (Baltimore) ; 102(23): e33996, 2023 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-37335655

RESUMEN

The aim of this article is to utilize ultrasound to evaluate the normal cross-sectional area (CSA)of the vagus nerve (VN) in the carotid sheath. This study included 86 VNs in 43 healthy subjects (15 men, 28 women); mean age 42.1 years and mean body mass index 26.2 kg/m2. For each subject, the bilateral VNs were identified by US at the anterolateral neck within the common carotid sheaths. One radiologist obtained 3 separate CSA measurements for each of the bilateral VNs with complete transducer removal between each measurement. Additionally, for each participant, demographic information of age and gender as well as body mass index, weight, and height were documented. The mean CSA of the right VN in the carotid sheath was 2.1 and 1.9 mm2 for the left VN. The right VN CSA was significantly larger than the left VN (P < .012). No statistically significant correlation was noted in relation to height, weight, and age. We believe that the reference values for the normal CSA of the VN obtained in our study, could help in the sonographic evaluation of VN enlargement, as it relates to the diagnosis of various diseases affecting the VN.


Asunto(s)
Cuello , Nervio Vago , Masculino , Humanos , Femenino , Adulto , Nervio Vago/diagnóstico por imagen , Ultrasonografía , Voluntarios Sanos , Valores de Referencia
6.
Medicine (Baltimore) ; 102(30): e34181, 2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37505169

RESUMEN

The aim of this study is to utilize ultrasound to evaluate the normal cross-sectional area (CSA) of the phrenic nerve (PN), at the level of the anterior scalene muscle. The study included 62 PNs in 31 healthy subjects (13 men, 18 women); mean age, 36.6 years; mean height, 161.1 cm; mean weight, 69.6 kg; and mean body mass index 25.8 kg/m2. High-resolution ultrasound images of the bilateral PNs were obtained by a radiologist with 15 years of experience in neuromusculoskeletal ultrasound. Three separate CSA measurements for the bilateral PNs bilaterally were obtained. Images were also reviewed by an experienced neurologist to evaluate for inter-rater variability. The mean CSA of the right PN was 0.54 mm2 ± 0.16. The mean CSA of the left PN was 0.53 mm2 ± 0.18. We believe that the reference values for the normal CSA of the PNs obtained in our study could help in the sonographic evaluation of PN enlargement, as it relates to the diagnosis of various diseases affecting the PN. Furthermore, knowledge of its location and size, at the level of the scalene muscle, could help prevent PN-related complications during interventional procedures in that area. Additionally, for each participant, demographic information of age and gender as well as body mass index, weight, and height were documented.


Asunto(s)
Músculos del Cuello , Nervio Frénico , Masculino , Humanos , Femenino , Adulto , Nervio Frénico/diagnóstico por imagen , Ultrasonografía/métodos , Valores de Referencia , Voluntarios Sanos
7.
Parkinsonism Relat Disord ; 112: 105451, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37236044

RESUMEN

BACKGROUND: Parkinson's disease (PD) is a major cause of disability. We aimed to assess the benefit of ultrasonography of the vagus nerve (VN) to compare between PD and healthy controls as well as to deliver reference values of nerve cross sectional area (CSA). MATERIALS AND METHODS: We performed a systematic search on Medline (PubMed), Scopus, Embase, and Web of Science, up till July 25, 2022. After article selection and screening, we performed a quality assessment using the Newcastle-Ottawa Scale. Furthermore, a statistical analysis and subgroup analysis was performed. RESULTS: Eleven studies were included with a total of 809 participants (409 PD patients and 400 controls). A statistically significant difference in the CSA of the right and left VN between PD patients and healthy controls was observed, indicating the atrophy of VN in PD patients (p < 0.00001). The subgroup meta-analysis for average measurements of VN CSA showed insignificant heterogeneity for age (I2 = 48.67%, p = 0.058), level of measurements (I2 = 57.91%, p = 0.05), and disease duration (I2 = 27.1%, p = 0.241). CONCLUSION: Our meta-analysis showed a sonographically detectable degree of neuronal damage in PD, which correlates with VN atrophy with high confidence. Therefore, we believe this is a potential marker for vagus neuronal lesions. Future studies are required to assess the potential clinical correlation.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/patología , Nervio Vago/diagnóstico por imagen , Ultrasonografía , Valores de Referencia
8.
Medicine (Baltimore) ; 100(2): e24071, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33466166

RESUMEN

ABSTRACT: The study included 38 ulnar nerves in 20 healthy subjects. High-resolution ultrasound and Shear wave elastography were used to evaluate the ulnar nerve at the mid forearm. The mean cross-sectional area of the ulnar nerve was 7.1 mm2. The mean shear elastic modulus of the nerve in the short axis was 27.4 kPa. The mean shear elastic modulus of the nerve in long axis was 24.7 kPa. No statistical relation could be noted between elasticity measurements in long and short axes. The ulnar nerve elastic modulus also showed no correlation with CSA neither in the long axis nor short axis. Age, height, weight, and body mass index showed no correlation with the ulnar elastic modulus in short or long axes. The elastic modulus of the ulnar nerve has been determined in healthy subjects and can serve as a reference for future assessment of compressive neuropathies of the ulnar nerve.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Antebrazo/diagnóstico por imagen , Antebrazo/inervación , Nervio Cubital/diagnóstico por imagen , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia
9.
Medicine (Baltimore) ; 99(37): e22120, 2020 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-32925760

RESUMEN

The purpose of this study is to study sonoelastographic features of the saphenous nerve.The study included 72 saphenous nerves in 36 healthy subjects. High resolution ultrasound and Shearwave elastography were used to evaluate the saphenous nerve. Cross sectional area (CSA) and stiffness were measured.The mean CSA of the saphenous nerve was 5.7 mm. The mean shear elastic modulus of the saphenous nerve in the short axis was 29.5 kPa. The mean shear elastic modulus of the saphenous nerve in long axis was 29.9 kPa. The saphenous nerve elastic modulus also showed no correlation with CSA in neither the long axis nor short axis. Positive correlation between elasticity measurements in the long and short axes. Age, height, weight, and BMI showed no correlation with saphenous nerve elastic modulus in short or long axes.The elastic modulus of the saphenous nerve has been determined in healthy subjects and can serve as a reference for future assessment of the saphenous nerve before different procedures.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Elasticidad/fisiología , Nervios Periféricos/diagnóstico por imagen , Nervios Periféricos/fisiología , Muslo/inervación , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Muslo/diagnóstico por imagen , Adulto Joven
10.
Mult Scler Relat Disord ; 29: 111-117, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30708308

RESUMEN

BACKGROUND: Multiple sclerosis (MS) is a chronic demyelinating disease of the central nervous system. Depression is common among MS patients. In patients without MS, lower vitamin D levels were associated with higher depression scores and severity. Supplementation of vitamin D was associated with significant improvement of depressive symptoms. OBJECTIVE: to evaluate the relation between vitamin D levels and depression scores, and the effect of vitamin D replacement on the depressive symptoms in patients with MS. METHODS: The study included 35 patients with relapsing remitting multiple sclerosis. Neurological, psychiatric, and radiological evaluations were done. Participants received 10,000 IU of cholecalciferol daily for 12 months. RESULTS: Vitamin D level was low at baseline. Depressive symptoms were high at baseline and improved with vitamin D replacement although, Expanded Disability Status Scale (EDSS) score was not improving. Vitamin D levels correlated negatively with depressive symptoms at baseline and follow up periods. CONCLUSION: Lower vitamin D levels are associated with higher depressive scores, and vitamin D replacement could improve depressive symptoms in patients with relapsing remitting multiple sclerosis.


Asunto(s)
Depresión/tratamiento farmacológico , Esclerosis Múltiple Recurrente-Remitente/tratamiento farmacológico , Esclerosis Múltiple Recurrente-Remitente/fisiopatología , Evaluación de Resultado en la Atención de Salud , Vitamina D/sangre , Vitamina D/farmacología , Adulto , Colecalciferol/farmacología , Depresión/sangre , Depresión/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Esclerosis Múltiple Recurrente-Remitente/sangre , Vitamina D/administración & dosificación
11.
Medicine (Baltimore) ; 97(24): e11104, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29901629

RESUMEN

The objective of this study is to determine whether the cross sectional area (CSA) measurement of the median nerve at the wrist differ between carpal tunnel syndrome (CTS) in diabetic patients with and without diabetic polyneuropathy (DPN).This study included 44 patients with type II diabete millitus (DM) with CTS, 32 patients with CTS and DPN, 46 patients with idiopathic CTS, and 42 healthy subjects. Ultrasonographic measurement of the CSA of the median nerve was made at the level of the wrist, together with nerve conduction studies.The median CSA at the wrist was significantly larger in all patient groups compared with healthy subjects. The median nerve CSA was significantly larger in diabetic patients with CTS than patients with idiopathic CTS. The median nerve CSA at wrist was significantly smaller in patients with CTS and DPN compared with diabetic patients with CTS only.The median nerve CSA at the wrist was larger in diabetic patients with CTS than patients with idiopathic CTS and CTS with DPN. Median nerve CSA can help to differentiate between diabetic patients with CTS with and without DPN.


Asunto(s)
Síndrome del Túnel Carpiano/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Neuropatías Diabéticas/complicaciones , Nervio Mediano/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Síndrome del Túnel Carpiano/etiología , Síndrome del Túnel Carpiano/fisiopatología , Neuropatías Diabéticas/diagnóstico por imagen , Neuropatías Diabéticas/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Conducción Nerviosa , Muñeca/diagnóstico por imagen
12.
Neurol Res ; 40(9): 805-810, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29873619

RESUMEN

OBJECTIVES: Sonoelastography is an emerging technology that has been used to evaluate the musculoskeletal system including the brachial plexus of peripheral nerves, which has been only recently considered for study by shear wave elastography. The purpose of this study is to establish the normal sonoelastographic features of the C5-C7 nerve roots of the brachial plexus. METHODS: Forty healthy individuals (21 males and 19 females) were enrolled in the study. Shear wave elastography was used to evaluate the C5-C7 nerve roots of the brachial plexus at the interscalene interval. Normal sonoelastographic values were obtained. RESULTS: The mean shear elastic modulus of the C5 nerve root was 16.9 kPa (range 5.9-28.8 ± 4.9 standard deviation, SD), 15.7 kPa (range 5.4-26.3 ± 4.3 SD) for the C6 nerve root, and 16 kPa (range 8-29 ± 4.6 SD) for the C7 nerve root. There was a significant statistical difference between both sexes in the elastic modulus at the C6 and C7, but not at the C5 nerve roots. Significant inverse correlation with height was noted at the C6 nerve root. There was no statistical significant difference in tissue stiffness between right- and left-handed subjects, age, and body mass index. CONCLUSION: The elastic modulus of the C5-C7 nerve roots has been determined in asymptomatic individuals and can serve as a reference when studying pathological conditions of these structures. ABBREVIATIONS: BMI: body mass index; SWE: shear wave elastography.


Asunto(s)
Plexo Braquial/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad , Raíces Nerviosas Espinales/diagnóstico por imagen , Adulto , Índice de Masa Corporal , Vértebras Cervicales/diagnóstico por imagen , Módulo de Elasticidad , Femenino , Humanos , Masculino , Adulto Joven
13.
Medicine (Baltimore) ; 97(12): e0179, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29561431

RESUMEN

The objective of this study is to estimate the reference values for the lower limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. The estimated reference values and their correlations with the age, weight, height, body mass index (BMI) were evaluated.The cross sectional area reference values were obtained at 5 predetermined sites for 3 important lower limb peripheral nerves. Our CSA values correlated significantly with age, weight, and BMI. The normal reference values for each nerve were as follows: Tibial nerve at the popliteal fossa 19 mm ±â€Š6.9, tibial nerve at the level of the medial malleolus 12.7 mm ±â€Š4.5, common peroneal nerve at the popliteal fossa 9.5 mm ±â€Š4, common peroneal nerve fibular head 8.9 mm ±â€Š3.2, sural nerve 3.5 mm ±â€Š1.4.The reference values for the lower limb peripheral nerves were identified. These values could be used for future management of peripheral nerve disorders.


Asunto(s)
Extremidad Inferior/inervación , Nervios Periféricos/anatomía & histología , Nervios Periféricos/diagnóstico por imagen , Ultrasonografía , Adulto , Anciano , Envejecimiento , Índice de Masa Corporal , Peso Corporal , Estudios Transversales , Humanos , Extremidad Inferior/anatomía & histología , Extremidad Inferior/diagnóstico por imagen , Persona de Mediana Edad , Tamaño de los Órganos , Valores de Referencia , Adulto Joven
14.
Medicine (Baltimore) ; 96(10): e6204, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28272211

RESUMEN

The objective of this study is to estimate the reference values for the number of fascicles and cross-sectional area (CSA) of the ulnar nerve at a single predetermined site by ultrasound in healthy young adult males.The demographic and physical characteristics of 50 adult male volunteers were evaluated and recorded. The subjects were positioned supine with the elbow flexed at 90° and the palm of the hand placed on a hard surface. The ulnar nerve was scanned bilaterally 1 cm proximal to the medial epicondyle in projection of the cubital tunnel. The number of fascicles and mean CSA of the ulnar nerve were identified. In addition, the side-to-side differences of the estimated reference values and their correlations with the age, weight, height, and body mass index (BMI) were evaluated.The mean fascicular number was 5.66 ±â€Š1.48, the mean ultrasound-estimated CSA of the ulnar nerve was 6.54 ±â€Š1.67 mm and both sides were comparable in the mean CSA and fascicular number (6.43 ±â€Š1.80 mm and 5.88 vs 6.64 ±â€Š1.55 mm and 5.44, for right and left side, respectively). No significant correlations were observed between CSA and fascicles number and age, weight, height, or BMI of study subjects.The reference values for the number of fascicles number and the CSA of the ulnar nerve at a single predetermined site were identified. These values could be used for the sonographic diagnosis and follow-up of the ulnar nerve lesions.


Asunto(s)
Nervio Cubital/diagnóstico por imagen , Ultrasonografía , Adolescente , Estudios Transversales , Voluntarios Sanos , Humanos , Masculino , Valores de Referencia , Adulto Joven
15.
Medicine (Baltimore) ; 96(50): e9306, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29390395

RESUMEN

The objective of this study is to estimate the reference values for the upper limb peripheral nerves in adults.The demographics and physical characteristics of 69 adult healthy volunteers were evaluated and recorded. In addition, the side to side differences of the estimated reference values and their correlations with the age, weight, height, and body mass index (BMI) were evaluated.Cross-sectional area reference values of the upper limb nerves did not correlate with height; however, they correlated with age, weight, and BMI in some scanned sites.The data obtained in this study could be helpful in future diagnosis of peripheral nerve disorders of the upper limb.


Asunto(s)
Nervios Periféricos/diagnóstico por imagen , Extremidad Superior/inervación , Adulto , Anciano , Estudios Transversales , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA