1.
J Appl Clin Med Phys ; 25(5): e14366, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38669190

RESUMEN

PURPOSE: Skin collimation is a useful tool in electron beam therapy (EBT) to decrease the penumbra at the field edge and minimize dose to nearby superficial organs at risk (OARs), but manually fabricating these collimation devices in the clinic to conform to the patient's anatomy can be a difficult and time intensive process. This work compares two types of patient-specific skin collimation (in-house 3D printed and vendor-provided machined brass) using clinically relevant metrics. METHODS: Attenuation measurements were performed to determine the thickness of each material needed to adequately shield both 6 and 9 MeV electron beams. Relative and absolute dose planes at various depths were measured using radiochromic film to compare the surface dose, flatness, and penumbra of the different skin collimation materials. RESULTS: Clinically acceptable thicknesses of each material were determined for both 6 and 9 MeV electron beams. Field width, flatness, and penumbra results between the two systems were very similar and significantly improved compared to measurements performed with no surface collimation. CONCLUSION: Both skin collimation methods investigated in this work generate sharp penumbras at the field edge and can minimize dose to superficial OARs compared to treatment fields with no surface collimation. The benefits of skin collimation are greatest for lower energy electron beams, and the benefits decrease as the measurement depth increases. Using bolus with skin collimation is recommended to avoid surface dose enhancement seen with collimators placed on the skin surface. Ultimately, the appropriate choice of material will depend on the desire to create these devices in-house or outsource the fabrication to a vendor.


Asunto(s)
Electrones , Órganos en Riesgo , Impresión Tridimensional , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Piel , Humanos , Electrones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo/efectos de la radiación , Piel/efectos de la radiación , Fantasmas de Imagen , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentación
2.
J Appl Clin Med Phys ; : e14342, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38590112

RESUMEN

BACKGROUND: Rescanning is a common technique used in proton pencil beam scanning to mitigate the interplay effect. Advances in machine operating parameters across different generations of particle therapy systems have led to improvements in beam delivery time (BDT). However, the potential impact of these improvements on the effectiveness of rescanning remains an underexplored area in the existing research. METHODS: We systematically investigated the impact of proton machine operating parameters on the effectiveness of layer rescanning in mitigating interplay effect during lung SBRT treatment, using the CIRS phantom. Focused on the Hitachi synchrotron particle therapy system, we explored machine operating parameters from our institution's current (2015) and upcoming systems (2025A and 2025B). Accumulated dynamic 4D dose were reconstructed to assess the interplay effect and layer rescanning effectiveness. RESULTS: Achieving target coverage and dose homogeneity within 2% deviation required 6, 6, and 20 times layer rescanning for the 2015, 2025A, and 2025B machine parameters, respectively. Beyond this point, further increasing the number of layer rescanning did not further improve the dose distribution. BDTs without rescanning were 50.4, 24.4, and 11.4 s for 2015, 2025A, and 2025B, respectively. However, after incorporating proper number of layer rescanning (six for 2015 and 2025A, 20 for 2025B), BDTs increased to 67.0, 39.6, and 42.3 s for 2015, 2025A, and 2025B machine parameters. Our data also demonstrated the potential problem of false negative and false positive if the randomness of the respiratory phase at which the beam is initiated is not considered in the evaluation of interplay effect. CONCLUSION: The effectiveness of layer rescanning for mitigating interplay effect is affected by machine operating parameters. Therefore, past clinical experiences may not be applicable to modern machines.

3.
J Appl Clin Med Phys ; 24(7): e14049, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37227694

RESUMEN

BACKGROUND: In order to compute the relative biological effectiveness (RBE) of ion radiation therapy with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM), it is necessary to process entire microdosimetric distributions. Therefore, a posteriori RBE recalculations (i.e., for a different cell line or another biological endpoint) would require whole spectral information. It is currently not practical to compute and store all this data for each clinical voxel. PURPOSE: To develop a methodology that allows to store a limited amount of physical information without losing accuracy in the RBE calculations nor the possibility of a posteriori RBE recalculations. METHODS: Computer simulations for four monoenergetic 12 C ion beams and a 12 C ion spread-out Bragg peak (SOBP) were performed to assess lineal energy distributions as a function of the depth within a water phantom. These distributions were used in combination with the MCF MKM to compute the in vitro clonogenic survival RBE for human salivary gland tumor cells (HSG cell line) and human skin fibroblasts (NB1RGB cell line). The RBE values were also calculated with a new abridged microdosimetric distribution methodology (AMDM) and compared with the reference RBE calculations using the entire distributions. RESULTS: The maximum relative deviation between the RBE values computed using the entire distributions and the AMDM was 0.61% (monoenergetic beams) and 0.49% (SOBP) for the HSG cell line, while 0.45% (monoenergetic beams) and 0.26% (SOBP) for the NB1RGB cell line. CONCLUSION: The excellent agreement between the RBE values computed using the entire lineal energy distributions and the AMDM represents a milestone for the clinical implementation of the MCF MKM.


Asunto(s)
Radioterapia de Iones Pesados , Humanos , Efectividad Biológica Relativa , Dosificación Radioterapéutica , Simulación por Computador , Cinética , Carbono/uso terapéutico
4.
J Appl Clin Med Phys ; 23(2): e13496, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34890094

RESUMEN

INTRODUCTION: This study presents a comprehensive collision avoidance framework based on three-dimension (3D) computer-aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient-specific plan parameters for intensity-modulated proton therapy (IMPT). METHODS: A stand-alone software application was developed leveraging the Varian scripting application programming interface (API) for RTP database object accessibility. The Collision Avoider software models the Hitachi ProBeat-V half gantry design and the Kuka robotic couch with triangle mesh structures. Patient-specific plan parameters are displayed in the collision avoidance software for potential proximity evaluation. The external surfaces of the patients and the immobilization devices are contoured based on computed tomography (CT) images. A "table junction-to-CT-origin" (JCT) measurement is made for every patient at the time of CT simulation to accurately provide reference location of the patient contours to the treatment couch. Collision evaluations were performed virtually with the program during treatment planning to prevent four major types of collisional events: collisions between the gantry head and the treatment couch, gantry head and the patient's body, gantry head and the robotic arm, and collisions between the gantry head and the immobilization devices. RESULTS: The Collision Avoider software was able to accurately model the proton treatment delivery system and the robotic couch position. Commonly employed clinical beam configuration and JCT values were investigated. Brain and head and neck patients require more complex gantry and patient positioning system configurations. Physical measurements were performed to validate 3D CAD model geometry. Twelve clinical proton treatment plans were used to validate the accuracy of the software. The software can predict all four types of collisional events in our clinic since its full implementation in 2020. CONCLUSION: A highly efficient patient-specific collision prevention program for scanning proton therapy has been successfully implemented. The graphical program has provided accurate collision detection since its inception at our institution.


Asunto(s)
Terapia de Protones , Radioterapia de Intensidad Modulada , Simulación por Computador , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Programas Informáticos , Tomografía Computarizada por Rayos X
5.
J Appl Clin Med Phys ; 23(4): e13527, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35060317

RESUMEN

PURPOSE: To evaluate the relative biological effectiveness (RBE)-weighted dose to the heart and to estimate RBE uncertainties when assuming a constant RBE of 1.1, for breast cancer patients receiving intensity-modulated proton therapy (IMPT). Further, to study the impact of RBE uncertainties on the risk of an acute coronary event (ACE). MATERIAL AND METHODS: We analyzed 20 patients who received IMPT to either the left breast (n = 10) or left chest wall (n = 10) and regional lymph nodes. The Monte Carlo simulation engine, MCsquare, was used to simulate the dose-averaged linear energy transfer (LETd) map. The RBE-weighted dose to the heart and its substructures was calculated using three different RBE models. The risk of ACE was estimated per its linear relationship with mean heart dose (MHD) as established by Darby et al. RESULTS: The median MHD increased from 1.33 GyRBE assuming an RBE of 1.1 to 1.64, 1.87, and 1.99 GyRBE when using the RBE-weighted dose models. The median values (and ranges) of the excess absolute risk of ACE were 0.4% (0.1%-0.8%) when assuming an RBE of 1.1, and 0.6% (0.2%-1.0%), 0.6% (0.2%-1.1%), and 0.7% (0.2%-1.1%) with the RBE-weighted models. For our patient cohort, the maximum excess absolute risk of ACE increased by 0.3% with the RBE-weighted doses compared to the constant RBE of 1.1, reaching an excess absolute ACE risk of 1.1%. The interpatient LETd variation was small for the relevant high-dose regions of the heart. CONCLUSION: All three RBE models predicted a higher biological dose compared to the clinical standard dose assuming a constant RBE of 1.1. An underestimation of the biological dose results in underestimation of the ACE risk. Analyzing the voxel-by-voxel biological dose and the LET map alongside clinical outcomes is warranted in the development of a more accurate normal-tissue complication probability model.


Asunto(s)
Neoplasias de la Mama , Terapia de Protones , Radioterapia de Intensidad Modulada , Neoplasias de la Mama/radioterapia , Femenino , Humanos , Terapia de Protones/efectos adversos , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Radioterapia de Intensidad Modulada/métodos , Efectividad Biológica Relativa
6.
Int J Mol Sci ; 23(20)2022 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-36293348

RESUMEN

The relative biological effectiveness (RBE) calculations used during the planning of ion therapy treatments are generally based on the microdosimetric kinetic model (MKM) and the local effect model (LEM). The Mayo Clinic Florida MKM (MCF MKM) was recently developed to overcome the limitations of previous MKMs in reproducing the biological data and to eliminate the need for ion-exposed in vitro data as input for the model calculations. Since we are considering to implement the MCF MKM in clinic, this article presents (a) an extensive benchmark of the MCF MKM predictions against corresponding in vitro clonogenic survival data for 4 rodent and 10 cell lines exposed to ions from 1H to 238U, and (b) a systematic comparison with published results of the latest version of the LEM (LEM IV). Additionally, we introduce a novel approach to derive an approximate value of the MCF MKM model parameters by knowing only the animal species and the mean number of chromosomes. The overall good agreement between MCF MKM predictions and in vitro data suggests the MCF MKM can be reliably used for the RBE calculations. In most cases, a reasonable agreement was found between the MCF MKM and the LEM IV.


Asunto(s)
Roedores , Animales , Humanos , Florida , Efectividad Biológica Relativa , Cinética , Línea Celular
7.
J Appl Clin Med Phys ; 22(7): 276-285, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34159715

RESUMEN

The primary objective is to evaluate the potential dosimetric gains of performing functional avoidance-based proton treatment planning using 4DCT derived ventilation imaging. 4DCT data of 31 patients from a prospective functional avoidance clinical trial were evaluated with intensity modulated proton therapy (IMPT) plans and compared with clinical volumetric modulated arc therapy (VMAT) plans. Dosimetric parameters were compared between standard and functional plans with IMPT and VMAT with one-way analysis of variance and post hoc paired student t-test. Normal Tissue Complication Probability (NTCP) models were employed to estimate the risk of two toxicity endpoints for healthy lung tissues. Dose degradation due to proton motion interplay effect was evaluated. Functional IMPT plans led to significant dose reduction to functional lung structures when compared with functional VMAT without significant dose increase to Organ at Risk (OAR) structures. When interplay effect is considered, no significant dose degradation was observed for the OARs or the clinical target volume (CTV) volumes for functional IMPT. Using fV20 as the dose metric and Grade 2+ pneumonitis as toxicity endpoint, there is a mean 5.7% reduction in Grade 2+ RP with the functional IMPT and as high as 26% in reduction for individual patient when compared to the standard IMPT planning. Functional IMPT was able to spare healthy lung tissue to avoid excess dose to normal structures while maintaining satisfying target coverage. NTCP calculation also shows that the risk of pulmonary complications can be further reduced with functional based IMPT.


Asunto(s)
Neoplasias Pulmonares , Terapia de Protones , Radioterapia de Intensidad Modulada , Humanos , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Órganos en Riesgo , Estudios Prospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
8.
Breast Cancer Res Treat ; 181(2): 291-296, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32318954

RESUMEN

PURPOSE: Breast cancer is the most commonly diagnosed cancer in women, with many efforts aimed at reducing acute and late toxicity given the generally favorable clinical outcomes with the current standard of care. Carbon ion radiation therapy is an emerging technique that may reduce dose to adjacent organs at risk while allowing dose escalation to the target. Given the efficacy of the standard treatments for breast cancer, there have been few prospective studies to date investigating carbon ion radiation therapy in breast cancer. METHODS: PubMed/Medline, Ebsco, Cochrane, and Scopus were systematically reviewed using the search terms "carbon ion" and "breast" in November 2019. Out of the 76 articles screened, 26 articles were included. RESULTS: This comprehensive review describes the physical and biological properties of carbon ion radiation therapy, with an emphasis on how these properties can be applied in the setting of breast cancer. Studies investigating the role of carbon ion radiation therapy in early stage breast cancers are reviewed. Additionally, the use of carbon ion radiation therapy in locally advanced disease, recurrent disease, and radiation-induced angiosarcoma are discussed. CONCLUSION: Although the data is limited, the early clinical results are promising. Further clinical trials are needed, especially in the setting of locally advanced and recurrent disease, to fully define the potential role of carbon ion radiation therapy in the treatment of breast cancer.


Asunto(s)
Neoplasias de la Mama/radioterapia , Radioterapia de Iones Pesados/métodos , Neoplasias de la Mama/patología , Femenino , Humanos , Pronóstico
9.
Acta Oncol ; 57(5): 629-636, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29129125

RESUMEN

PURPOSE: To demonstrate the clinical efficacy and safety of a highly conformal, supine, hybrid forward and inverse planned intensity modulated radiation therapy (IMRT) technique for photon craniospinal irradiation (CSI). METHODS: Patients who received supine, hybrid IMRT CSI from 2009 to 2014 were included in this retrospective review. Clinical target volume (CTV) was defined as intracranial contents and thecal sac, including nerve roots. Dose was prescribed such that >99% of CTV received >99% of prescription and >95% of the planning target volume received >95% of prescription, with no attempt to include vertebral bodies. Lateral fields were utilized at the cranium and upper cervical spine. Spine fields were either single posterior or 2-3 obliques. Plans were generated with a hybrid of forward and inverse planned IMRT. Inferior borders of the cranium fields and superior border of the lower spine field were designed with 6-15 cm long, gradual dose gradients by sequential closing of multileaf collimator leaves using forward planned multiple static segment IMRT delivery. The sliding window upper spine IMRT field was created by the inverse planning system to match gradients of the brain and lower spine fields. The lower spine field gradient was similarly completed. RESULTS: The cohort consisted of 34 patients. Median CSI dose was 36 Gy (range: 18-39.6 Gy). With a median follow up of 59.4 months, there were no isolated recurrences or spinal myelopathies at CTV margins or field gradients. Eleven patients had recurrence, all of which were intracranial. CONCLUSIONS: Our hybrid forward and inverse planned IMRT supine CSI technique did not result in any isolated recurrences or myelopathies at CTV margins or field gradients. This suggests our target volumes and blended gradients are appropriate for highly conformal three-dimensional planning.


Asunto(s)
Neoplasias del Sistema Nervioso Central/radioterapia , Irradiación Craneoespinal/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias del Sistema Nervioso Central/mortalidad , Supervivencia sin Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Estudios Retrospectivos
11.
J Appl Clin Med Phys ; 15(4): 4413, 2014 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-25207391

RESUMEN

The purpose of this study was to develop a simplified methodology that will produce Monte Carlo (MC) dose distribution for proton therapy which can be used as a clinical aid in determining the adequacy of proton plans produced from the treatment planning system (TPS). The Geant4 Monte Carlo toolkit was used for all simulations. The geometry of the double scatter nozzle in the simulation was a simplification of the treatment nozzle. The proton source was modeled as discrete energy layers, each with a unique energy distribution and weighting factor. The simplified MC system was designed to give the same dose distribution as the measured data used to commission the TPS. After the simplified MC system was finalized, a series of verification comparisons were made between it, measurements, and the clinically used TPS. Comparisons included the lateral profile of a stair-shaped compensator that simulated a sharp lateral heterogeneity and depth-dose measurements through heterogeneous materials. The simplified MC system matched measurements to within 2% or 2 mm for all commissioning data under investigation; moreover, the distal edge and lateral penumbra was within 1 mm of the measurements. The simplified MC system was able to better reproduce the measured profiles for a stair-shaped compensator than the TPS. Both MC and TPS matched the measured depth dose through heterogeneous materials to within 2% or 2 mm. The simplified MC system was straightforward to implement, and produced accurate results when compared to measurements. Therefore, it holds promise as a clinically useful methodology to validate the relative dose distribution of patient treatment plans produced by the treatment planning systems.


Asunto(s)
Método de Montecarlo , Terapia de Protones , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Alta Energía , Simulación por Computador , Humanos , Modelos Teóricos , Fantasmas de Imagen , Dosificación Radioterapéutica , Programas Informáticos
12.
Phys Imaging Radiat Oncol ; 29: 100564, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38544867

RESUMEN

Background and Purpose: The effort to translate clinical findings across institutions employing different relative biological effectiveness (RBE) models of ion radiotherapy has rapidly grown in recent years. Nevertheless, even for a chosen RBE model, different implementations exist. These approaches might consider or disregard the dose-dependence of the RBE and the radial variation of the radiation quality around the beam axis. This study investigated the theoretical impact of disregarding these effects during the RBE calculations. Materials and Methods: Microdosimetric simulations were carried out using the Monte Carlo code PHITS along the spread out Bragg peaks of 1H, 4He, 12C, 16O, and 20Ne ions in a water phantom. The RBE was computed using different implementations of the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM) and the modified MKM, considering or not the radial variation of the radiation quality in the penumbra of the ion beams and the dose-dependence of the RBE. Results: For an OAR located 5 mm laterally from the target volume, disregarding the radial variation of the radiation quality or the dose-dependence of the RBE could result in an overestimation of the RBE-weighted dose up to a factor of âˆ¼ 3.5 or âˆ¼ 1.7, respectively. Conclusions: The RBE-weighted dose to OARs close to the tumor volume was substantially impacted by the approach employed for the RBE calculations, even when using the same RBE model and cell line. Therefore, care should be taken in considering these differences while translating clinical findings between institutions with dissimilar approaches.

13.
Radiat Res ; 201(6): 604-616, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38376467

RESUMEN

This study offers a review of published data on DNA double strand break (DSB) repair kinetics after exposure to ionizing radiation. By compiling a database, which currently includes 285 DNA DSB repair experiments utilizing both photons and ions, we investigate the impact of distinct experimental parameters on the kinetics of DNA DSB repair. Methodological differences and inconsistencies in reporting make the comparison of data generated by different research groups challenging. Nevertheless, by implementing filtering criteria, we can compare repair kinetics obtained with normal and tumor cells derived from human or animal tissues, as well as cells exposed to photons or ions ranging from hydrogen to iron ions. In addition, several repair curves of repair deficient cell lines were included. The study aims to provide researchers with a comprehensive overview of experimental factors that may confound results and emphasize the importance of precise reporting of experimental parameters. Moreover, we identify gaps in the literature that require attention in future studies, aiming to address clinically relevant questions related to radiotherapy. The database can be freely accessed at: https://github.com/weradstake/DRDNA.


Asunto(s)
Roturas del ADN de Doble Cadena , Reparación del ADN , Fotones , Roturas del ADN de Doble Cadena/efectos de la radiación , Humanos , Reparación del ADN/efectos de la radiación , Cinética , Animales , Iones
14.
Artículo en Inglés | MEDLINE | ID: mdl-38707713

RESUMEN

Carbon-ion radiation therapy (CIRT) is an up-and-coming modality for cancer treatment. Implementation of CIRT requires collaboration among specialists like radiation oncologists, medical physicists, and other healthcare professionals. Effective communication among team members is necessary for the success of CIRT. However, the current workflows involving data management, treatment planning, scheduling, and quality assurance (QA) can be susceptible to errors, leading to delays and decreased efficiency. With the aim of addressing these challenges, a team of medical physicists developed an in-house workflow management software using FileMaker Pro. This tool has streamlined the workflow and improved the efficiency and quality of patient care.

15.
Med Phys ; 51(3): 2239-2250, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37877590

RESUMEN

BACKGROUND: Using the pencil beam raster scanning method employed at most carbon beam treatment facilities, spots can be moved without interrupting the beam, allowing for the delivery of a dose between spots (move dose). This technique is also known as Dose-Driven-Continuous-Scanning (DDCS). To minimize its impact on HIMAK patient dosimetry, there's an upper limit to the move dose. Spots within a layer are grouped into sets, or "break points," allowing continuous irradiation. The beam is turned off when transitioning between sets or at the end of a treatment layer or spill. The control system beam-off is accomplished by turning off the RF Knockout (RFKO) extraction and after a brief delay the High Speed Steering Magnet (HSST) redirects the beam transport away from isocenter to a beam dump. PURPOSE: The influence of the move dose and beam on/off control on the dose distribution and irradiation time was evaluated by measurements never before reported and modelled for Hitachi Carbon DDCS. METHOD: We conducted fixed-point and scanning irradiation experiments at three different energies, both with and without breakpoints. For fixed-point irradiation, we utilized a 2D array detector and an oscilloscope to measure beam intensity over time. The oscilloscope data enabled us to confirm beam-off and beam-on timing due to breakpoints, as well as the relative timing of the RFKO signal, HSST signal, and dose monitor (DM) signals. From these measurements, we analyzed and modelled the temporal characteristics of the beam intensity. We also developed a model for the spot shape and amplitude at isocenter occurring after the beam-off signal which we called flap dose and its dependence on beam intensity. In the case of scanning irradiation, we measured move doses using the 2D array detector and compared these measurements with our model. RESULT: We observed that the most dominant time variation of the beam intensity was at 1 kHz and its harmonic frequencies. Our findings revealed that the derived beam intensity cannot reach the preset beam intensity when each spot belongs to different breakpoints. The beam-off time due to breakpoints was approximately 100 ms, while the beam rise time and fall time (tdecay ) were remarkably fast, about 10 ms and 0.2 ms, respectively. Moreover, we measured the time lag (tdelay ) of approximately 0.2 ms between the RFKO and HSST signals. Since tdelay ≈ tdecay at HIMAK then the HSST is activated after the residual beam intensity, resulting in essentially zero flap dose at isocenter from the HSST. Our measurements of the move dose demonstrated excellent agreement with the modelled move dose. CONCLUSION: We conducted the first move dose measurement for a Hitachi Carbon synchrotron, and our findings, considering beam on/off control details, indicate that Hitachi's carbon synchrotron provides a stable beam at HIMAK. Our work suggests that measuring both move dose and flap dose should be part of the commissioning process and possibly using our model in the Treatment Planning System (TPS) for new facilities with treatment delivery control systems with higher beam intensities and faster beam-off control.


Asunto(s)
Iones Pesados , Terapia de Protones , Humanos , Terapia de Protones/métodos , Iones , Planificación de la Radioterapia Asistida por Computador/métodos , Carbono/uso terapéutico , Dosificación Radioterapéutica
16.
Front Oncol ; 14: 1295251, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38487718

RESUMEN

Introduction: Manual review of organ at risk (OAR) contours is crucial for creating safe radiotherapy plans but can be time-consuming and error prone. Statistical and deep learning models show the potential to automatically detect improper contours by identifying outliers using large sets of acceptable data (knowledge-based outlier detection) and may be able to assist human reviewers during review of OAR contours. Methods: This study developed an automated knowledge-based outlier detection method and assessed its ability to detect erroneous contours for all common head and neck (HN) OAR types used clinically at our institution. We utilized 490 accurate CT-based HN structure sets from unique patients, each with forty-two HN OAR contours when anatomically present. The structure sets were distributed as 80% for training, 10% for validation, and 10% for testing. In addition, 190 and 37 simulated contours containing errors were added to the validation and test sets, respectively. Single-contour features, including location, shape, orientation, volume, and CT number, were used to train three single-contour feature models (z-score, Mahalanobis distance [MD], and autoencoder [AE]). Additionally, a novel contour-to-contour relationship (CCR) model was trained using the minimum distance and volumetric overlap between pairs of OAR contours to quantify overlap and separation. Inferences from single-contour feature models were combined with the CCR model inferences and inferences evaluating the number of disconnected parts in a single contour and then compared. Results: In the test dataset, before combination with the CCR model, the area under the curve values were 0.922/0.939/0.939 for the z-score, MD, and AE models respectively for all contours. After combination with CCR model inferences, the z-score, MD, and AE had sensitivities of 0.838/0.892/0.865, specificities of 0.922/0.907/0.887, and balanced accuracies (BA) of 0.880/0.900/0.876 respectively. In the validation dataset, with similar overall performance and no signs of overfitting, model performance for individual OAR types was assessed. The combined AE model demonstrated minimum, median, and maximum BAs of 0.729, 0.908, and 0.980 across OAR types. Discussion: Our novel knowledge-based method combines models utilizing single-contour and CCR features to effectively detect erroneous OAR contours across a comprehensive set of 42 clinically used OAR types for HN radiotherapy.

17.
Med Phys ; 2024 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-38922975

RESUMEN

BACKGROUND: Intensity Modulated Proton Therapy (IMPT) is a sophisticated radiation treatment allowing for precise dose distributions. However, conventional spot selection strategies in IMPT face challenges, particularly with minimum monitor unit (MU) constraints, affecting planning quality and efficiency. PURPOSE: This study introduces an innovative Two-Stage Mixed Integer Linear Programming (MILP) method to optimize spot intensity in IMPT with Lower Bound (LB) constraints. This method seeks to improve treatment planning efficiency and precision, overcoming limitations of existing strategies. METHODS: Our approach evaluates prevalent IMPT spot selection strategies, identifying their limitations, especially concerning MU constraints. We integrated LB constraints into a MILP framework, using a novel three-phase strategy for spot pool selection, to enhance performance over traditional heuristic methods and L1 + L∞ strategies. The method's efficacy was tested in eight study cases, using Dose-Volume Histograms (DVHs), spot selection efficiency, and computation time analysis for benchmarking against established methods. RESULTS: The proposed method showed superior performance in DVH quality, adhering to LB constraints while maintaining high-quality treatment plans. It outperformed existing techniques in spot selection, reducing unnecessary spots and balancing precision with efficiency. Cases studies confirmed the method's effectiveness in producing clinically feasible plans with enhanced dose distributions and reduced hotspots, especially in cases with elevated LB constraints. CONCLUSIONS: Our Two-Stage MILP strategy signifies a significant advancement in IMPT treatment planning. By incorporating LB constraints directly into the optimization process, it achieves superior plan quality and deliverability compared to current methods. This approach is particularly advantageous in clinical settings requiring minimum spot number and high MU LB constraints, offering the potential for improved patient outcomes through more precise and efficient radiation therapy plans.

18.
Int J Radiat Oncol Biol Phys ; 119(3): 924-935, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38310485

RESUMEN

PURPOSE: Proton relative biological effectiveness (RBE) is a dynamic variable influenced by factors like linear energy transfer (LET), dose, tissue type, and biological endpoint. The standard fixed proton RBE of 1.1, currently used in clinical planning, may not accurately represent the true biological effects of proton therapy (PT) in all cases. This uncertainty can contribute to radiation-induced normal tissue toxicity in patients. In late-responding tissues such as the spinal cord, toxicity can cause devastating complications. This study investigated spinal cord tolerance in mice subjected to proton irradiation and characterized the influence of fractionation on proton- induced myelopathy at entrance (ENT) and Bragg peak (BP) positions. METHODS AND MATERIALS: Cervical spinal cords of 8-week-old C57BL/6J female mice were irradiated with single- or multi-fractions (18x) using lateral opposed radiation fields at 1 of 2 positions along the Bragg curve: ENT (dose-mean LET = 1.2 keV/µm) and BP (LET = 6.9 keV/µm). Mice were monitored over 1 year for changes in weight, mobility, and general health, with radiation-induced myelopathy as the primary biological endpoint. Calculations of the RBE of the ENT and BP curve (RBEENT/BP) were performed. RESULTS: Single-fraction RBEENT/BP for 50% effect probability (tolerance dose (TD50), grade II paresis, determined using log-logistic model fitting) was 1.10 ± 0.06 (95% CI) and for multifraction treatments it was 1.19 ± 0.05 (95% CI). Higher incidence and faster onset of paralysis were seen in mice treated at the BP compared with ENT. CONCLUSIONS: The findings challenge the universally fixed RBE value in PT, indicating up to a 25% mouse spinal cord RBEENT/BP variation for multifraction treatments. These results highlight the importance of considering fractionation in determining RBE for PT. Robust characterization of proton-induced toxicity, aided by in vivo models, is paramount for refining clinical decision-making and mitigating potential patient side effects.


Asunto(s)
Fraccionamiento de la Dosis de Radiación , Transferencia Lineal de Energía , Ratones Endogámicos C57BL , Terapia de Protones , Tolerancia a Radiación , Efectividad Biológica Relativa , Médula Espinal , Animales , Femenino , Médula Espinal/efectos de la radiación , Ratones , Terapia de Protones/efectos adversos , Protones/efectos adversos , Relación Dosis-Respuesta en la Radiación
19.
Phys Med Biol ; 69(13)2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38862000

RESUMEN

Objective.In proton pencil beam scanning (PBS) continuous delivery, the beam is continuously delivered without interruptions between spots. For synchrotron-based systems, the extracted beam current exhibits a spill structure, and recent publications on beam current measurements have demonstrated significant fluctuations around the nominal values. These fluctuations potentially lead to dose deviations from those calculated assuming a stable beam current. This study investigated the dosimetric implications of such beam current fluctuations during proton PBS continuous scanning.Approach.Using representative clinical proton PBS plans, we performed simulations to mimic a worst-case clinical delivery environment with beam current varies from 50% to 250% of the nominal values. The simulations used the beam delivery parameters optimized for the best beam delivery efficiency of the upcoming particle therapy system at Mayo Clinic Florida. We reconstructed the simulated delivered dose distributions and evaluated the dosimetric impact of beam current fluctuations.Main results.Despite significant beam current fluctuations resulting in deviations at each spot level, the overall dose distributions were nearly identical to those assuming a stable beam current. The 1 mm/1% Gamma passing rate was 100% for all plans. Less than 0.2% root mean square error was observed in the planning target volume dose-volume histogram. Minimal differences were observed in all dosimetric evaluation metrics.Significance.Our findings demonstrate that with our beam delivery system and clinical planning practice, while significant beam current fluctuations may result in large local move monitor unit deviations at each spot level, the overall impact on the dose distribution is minimal.


Asunto(s)
Terapia de Protones , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Sincrotrones , Terapia de Protones/métodos , Terapia de Protones/instrumentación , Radiometría/instrumentación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Método de Montecarlo
20.
Med Dosim ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38824052

RESUMEN

Mayo Clinic Florida will initially open with the capability to treat with a single horizontal port for carbon ion therapy. Carbon ion therapy is traditionally done using a multi fixed port treatment approach. In this study, for nine treatment sites, clinically approved treatment plan of Osaka Heavy Ion Therapy Center was compared to a treatment plan using only a horizontal port. The treatment sites evaluated in this study were prostate cancer, pancreatic cancer, cervical cancer, recurrent rectal cancer, liver cancer, head and neck cancer, bone cancer (sarcoma and chordoma), and lung cancer. As expected, the prostate plans are identical and are only included for completeness. The DVH results for the pancreas and cervical cancer were very similar. The results for recurrent rectal, head and neck, sarcoma, chordoma, and lung cancer indicate that a single horizontal port with couch roll and yaw will accommodate certain medial targets but will be challenging to treat for laterally located targets without creative mitigations.