Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Monit Comput ; 30(4): 399-408, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26115774

RESUMEN

A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance imaging (CMR) has been performed. We therefore aimed to prospectively assess the accuracy and reproducibility of EV compared to CMR. 152 consecutive stable patients undergoing CMR were enrolled. EV measurements were taken twice before or after CMR in supine position and averaged over 20 s (AESCULON(®), Osypka Medical, Berlin, Germany). Bland-Altman analysis showed insufficient agreement of EV and CMR with a mean bias of 1.2 ± 1.4 l/min (bias 23 ± 26 %, percentage error 51 %). Reproducibility was high with 0.0 ± 0.3 l/min (bias 0 ± 8 %, percentage error 15 %). Outlier analysis revealed gender, height, CO and stroke volume (SV) by CMR as independent predictors for larger variation. Stratification of COCMR in quintiles demonstrated a good agreement for low values (<4.4 l/min) with bias increasing significantly with quintile as high as 3.1 ± 1.1 l/min (p < 0.001). Reproducibility was not affected (p = 0.71). Subgroup analysis in patients with arrhythmias (p = 0.19), changes in thoracic fluid content (p = 0.51) or left heart failure (p = 0.47) could not detect significant differences in accuracy. EV showed insufficient agreement with CMR and good reproducibility. Gender, height and increasing CO and SV were associated with increased bias while not affecting reproducibility. Therefore, absolute values should not be used interchangeably in clinical routine. EV yet may find its place for clinical application with further investigation on its trending ability pending.


Asunto(s)
Gasto Cardíaco , Cardiografía de Impedancia/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas , Estatura , Impedancia Eléctrica , Femenino , Corazón/fisiología , Insuficiencia Cardíaca , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Estudios Prospectivos , Reproducibilidad de los Resultados , Reología/métodos , Volumen Sistólico , Factores de Tiempo , Adulto Joven
2.
Molecules ; 21(10)2016 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-27775617

RESUMEN

Two light-emitting polyphenylene dendrimers with both hole and electron transporting moieties were synthesized and characterized. Both molecules exhibited pure blue emission solely from the pyrene core and efficient surface-to-core energy transfers when characterized in a nonpolar environment. In particular, the carbazole- and oxadiazole-functionalized dendrimer (D1) manifested a pure blue emission from the pyrene core without showing intramolecular charge transfer (ICT) in environments with increasing polarity. On the other hand, the triphenylamine- and oxadiazole-functionalized one (D2) displayed notable ICT with dual emission from both the core and an ICT state in highly polar solvents. D1, in a three-layer organic light emitting diode (OLED) by solution processing gave a pure blue emission with Commission Internationale de l'Éclairage 1931 CIE xy = (0.16, 0.12), a peak current efficiency of 0.21 cd/A and a peak luminance of 2700 cd/m². This represents the first reported pure blue dendrimer emitter with bipolar charge transport and surface-to-core energy transfer in OLEDs.


Asunto(s)
Dendrímeros/síntesis química , Polímeros/química , Carbazoles/química , Dendrímeros/química , Transporte de Electrón , Transferencia de Energía , Luz , Oxadiazoles/química
3.
Int J Comput Assist Radiol Surg ; 16(4): 629-638, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33677758

RESUMEN

PURPOSE: Active anterior rhinomanometry (AAR) and computed tomography (CT) are standardized methods for the evaluation of nasal obstruction. Recent attempts to correlate AAR with CT-based computational fluid dynamics (CFD) have been controversial. We aimed to investigate this correlation and agreement based on an in-house developed procedure. METHODS: In a pilot study, we retrospectively examined five subjects scheduled for septoplasty, along with preoperative digital volume tomography and AAR. The simulation was performed with Sailfish CFD, a lattice Boltzmann code. We examined the correlation and agreement of pressure derived from AAR (RhinoPress) and simulation (SimPress) and these of resistance during inspiration by 150 Pa pressure drop derived from AAR (RhinoRes150) and simulation (SimRes150). For investigation of correlation between pressures and between resistances, a univariate analysis of variance and a Pearson's correlation were performed, respectively. For investigation of agreement, the Bland-Altman method was used. RESULTS: The correlation coefficient between RhinoPress and SimPress was r = 0.93 (p < 0.001). RhinoPress was similar to SimPress in the less obstructed nasal side and two times greater than SimPress in the more obstructed nasal side. A moderate correlation was found between RhinoRes150 and SimRes150 (r = 0.65; p = 0.041). CONCLUSION: The simulation of rhinomanometry pressure by CT-based CFD seems more feasible with the lattice Boltzmann code in the less obstructed nasal side. In the more obstructed nasal side, error rates of up to 100% were encountered. Our results imply that the pressure and resistance derived from CT-based CFD and AAR were similar, yet not same.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Hidrodinámica , Obstrucción Nasal/diagnóstico por imagen , Tabique Nasal/diagnóstico por imagen , Rinomanometría/métodos , Adulto , Anciano , Simulación por Computador , Femenino , Humanos , Masculino , Obstrucción Nasal/cirugía , Tabique Nasal/cirugía , Proyectos Piloto , Reproducibilidad de los Resultados , Estudios Retrospectivos , Rinoplastia , Programas Informáticos , Tomografía Computarizada por Rayos X , Adulto Joven
4.
J Thorac Imaging ; 34(5): 338-344, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30801452

RESUMEN

OBJECTIVES: Left ventricular (LV) hypertrophy in resistant hypertensive patients is associated with a reduced intramyocardial perfusion. Renal sympathetic denervation (RDN) has been shown to reduce blood pressure (BP) and sympathetic tone. We aimed to prospectively investigate the effect of RDN on functional myocardial parameters and myocardial perfusion reserve (MPR) using cardiac magnetic resonance imaging (cMRI) in patients with resistant hypertension. METHODS: A total of 15 resistant hypertensive patients (11 male individuals, mean age 62±13 y) were included. Adenosine stress-induced cMRI was performed at baseline, 3, 6, and 12 months after RDN. RDN was performed using a single soft-tip radiofrequency catheter (Symplicity). cMRI semiquantitative perfusion analysis was performed using the upslope of myocardial signal enhancement to derive the myocardial perfusion reserve index. RESULTS: Both systolic-BP and diastolic-BP significantly decreased from 148±14 to 133±14 mm Hg and 87±14 to 80±10 mm Hg, respectively (P<0.05). LV septal wall thickness was significantly reduced (P<0.001). LV ejection fraction and MPR lacked significant trends 12 months after RDN. CONCLUSIONS: In this pilot study, RDN significantly reduced LV mass and LV septal wall thickness, as diagnosed by cMRI, with no significant changes in MPR. cMRI may help in diagnosing clinically relevant changes of functional myocardial parameters after interventional therapy in resistant hypertensive patients.


Asunto(s)
Corazón/diagnóstico por imagen , Hipertensión/complicaciones , Hipertrofia Ventricular Izquierda/complicaciones , Hipertrofia Ventricular Izquierda/cirugía , Imagen por Resonancia Magnética/métodos , Simpatectomía/métodos , Femenino , Estudios de Seguimiento , Corazón/fisiopatología , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Humanos , Hipertensión/fisiopatología , Hipertrofia Ventricular Izquierda/patología , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Proyectos Piloto , Estudios Prospectivos , Arteria Renal , Resultado del Tratamiento
5.
Physiol Meas ; 37(9): 1422-35, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27480359

RESUMEN

Electrical velocimetry (EV) is one of the most recent adaptions of impedance cardiography. Previous studies yielded diverging results identifying several factors negatively influencing accuracy. Although electrode arrangement is suspected to be an influencing factor for impedance cardiography in general, no data for EV is available. We aimed to prospectively assess the influence of electrode position on the accuracy and reproducibility of cardiac output (CO) measurements obtained by EV. Two pairs of standard electrocardiographic electrodes were placed at predefined positions of the thorax in 81 patients. The inter-electrode gap was varied between either 5 or 15 cm by caudal movement of the lowest electrode. Measurements were averaged over 20 s and performed twice at each electrode position. Reference values were determined using cardiac magnetic resonance imaging (CMR). Mean bias was 1.2 ± 1.6 l min(-1) (percentage error 22 ± 28%) between COCMR and COEV at the 5 cm gap significantly improving to 0.5 ± 1.6 l min(-1) (8 ± 28%) when increasing the gap (p < 0.0001). The mean difference between repeated measurements was 0.0 ± 0.3 l min(-1) for the 5 cm and 0.1 ± 0.3 l min(-1) for the 15 cm gap, respectively (p = 0.3). The accuracy of EV can be significantly improved when increasing the lower inter-electrode gap still exceeding the Critchley and Critchley recommendations. Therefore, absolute values should not be used interchangeably in clinical routine. As the reproducibility was not negatively affected, serial hemodynamic measurements can be reliably acquired in stable patients when the electrode position remains unchanged.


Asunto(s)
Gasto Cardíaco , Reología/instrumentación , Cardiografía de Impedancia , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
6.
Clin Res Cardiol ; 100(10): 935-43, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21720853

RESUMEN

BACKGROUND: When assessing the function of the cardiovascular system, cardiac output (CO) is a substantial parameter. For its determination, numerous non-invasive techniques have been proposed in the recent years including inert gas rebreathing (IGR) and impedance cardiography (ICG). The aim of our study was to evaluate whether a novel ICG algorithm (electrical velocimetry) and IGR can be used interchangeably in the clinical setting. METHODS: A total of 120 consecutive stable patients were included resulting in two pairs of repeated non-invasive cardiac output measurements. RESULTS: The mean CO was 5.0 ± 1.2 l/min (range 2.6-8.6 l/min) using IGR and 4.4 ± 1.1 l/min (1.7-7.4 l/min) using ICG, respectively. Bland-Altman analysis revealed an acceptable agreement with a mean bias of 0.6 ± 1.2 l/min. We found a high reproducibility with a mean bias of 0.2 ± 0.7 l/min for IGR and 0.0 ± 0.3 l/min for ICG (p < 0.001), respectively. There was a statistically significant difference for unphysiological circulatory conditions represented by values of 2.6-4.1 l/min and 5.6-8.6 l/min. CONCLUSIONS: Both non-invasive techniques are associated with low operating costs and require only a few expendable items for the rapid determination of cardiac function. We found an acceptable agreement between IGR and ICG as well as a high reproducibility, which was statistically significant higher for ICG. For cardiac output states exceeding the physiological range, we found a statistically significant difference. Consequently, values of cardiac function determined by either method should not be used interchangeably in the clinical setting.


Asunto(s)
Pruebas Respiratorias , Gasto Cardíaco , Cardiografía de Impedancia , Enfermedades Cardiovasculares/diagnóstico , Pruebas de Función Cardíaca/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Enfermedades Cardiovasculares/fisiopatología , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Óxido Nitroso , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Hexafluoruro de Azufre , Factores de Tiempo , Adulto Joven
7.
Biosens Bioelectron ; 26(4): 1706-9, 2010 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-20719493

RESUMEN

Process control methods for cell culture bioreactors include on-line monitoring of protein concentrations. Bioreactor samples typically contain high amounts of different proteins. The direct detection of a single protein in this complex medium is a challenging task within the development of biosensors with label-free detection. We introduce the development of a mass-sensitive biosensor based on surface acoustic waves (SAW) for the detection of hepatocyte growth factor/scatter factor (HGF/SF) in the serum containing medium of a miniaturized bioreactor for culturing hepatocytes. The specificity of the biosensor was obtained following two approaches. In the first approach, antibodies against HGF (anti-HGF) were immobilized covalently via an intermediate layer of dicarboxy polyethylene glycol on the biosensor surface. In the second approach, dextran sulfate and fucoidan were used as sensor coatings exploiting the fact that HGF binds specifically to those sulfated polysaccharides. Performing HGF assays, similar results were obtained using biosensors coated with dextran sulfate and biosensors coated with anti-HGF. Even higher sensor signals were obtained using biosensors coated with fucoidan, particularly at 37°C. Therefore, biosensor coatings based on biospecific sulfated polysaccharides offer a simple and cost-saving alternative compared to the commonly used coating with antibodies.


Asunto(s)
Técnicas Biosensibles/métodos , Medios de Cultivo/análisis , Factor de Crecimiento de Hepatocito/análisis , Polisacáridos , Acústica , Anticuerpos Inmovilizados , Reactores Biológicos , Materiales Biocompatibles Revestidos , Sulfato de Dextran , Células Hep G2 , Factor de Crecimiento de Hepatocito/inmunología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA