Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 293
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Nature ; 619(7968): 41-45, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37344593

RESUMEN

The centre of the Milky Way Galaxy hosts a black hole with a solar mass of about 4 million (Sagittarius A* (Sgr A)) that is very quiescent at present with a luminosity many orders of magnitude below those of active galactic nuclei1. Reflection of X-rays from Sgr A* by dense gas in the Galactic Centre region offers a means to study its past flaring activity on timescales of hundreds and thousands of years2. The shape of the X-ray continuum and the strong fluorescent iron line observed from giant molecular clouds in the vicinity of Sgr A* are consistent with the reflection scenario3-5. If this interpretation is correct, the reflected continuum emission should be polarized6. Here we report observations of polarized X-ray emission in the direction of the molecular clouds in the Galactic Centre using the Imaging X-ray Polarimetry Explorer. We measure a polarization degree of 31% ± 11%, and a polarization angle of -48° ± 11°. The polarization angle is consistent with Sgr A* being the primary source of the emission, and the polarization degree implies that some 200 years ago, the X-ray luminosity of Sgr A* was briefly comparable to that of a Seyfert galaxy.

2.
Nature ; 612(7941): 658-660, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36543953

RESUMEN

Pulsar wind nebulae are formed when outflows of relativistic electrons and positrons hit the surrounding supernova remnant or interstellar medium at a shock front. The Vela pulsar wind nebula is powered by a young pulsar (B0833-45, aged 11,000 years)1 and located inside an extended structure called Vela X, which is itself inside the supernova remnant2. Previous X-ray observations revealed two prominent arcs that are bisected by a jet and counter jet3,4. Radio maps have shown high linear polarization of 60% in the outer regions of the nebula5. Here we report an X-ray observation of the inner part of the nebula, where polarization can exceed 60% at the leading edge-approaching the theoretical limit of what can be produced by synchrotron emission. We infer that, in contrast with the case of the supernova remnant, the electrons in the pulsar wind nebula are accelerated with little or no turbulence in a highly uniform magnetic field.

3.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519418

RESUMEN

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Anciano , Estudios Prospectivos , Factores de Tiempo , Italia , Factores de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Supervivencia sin Progresión
4.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38291925

RESUMEN

A significant proportion of patients who suffer from atrial fibrillation (AF) and are in need of thromboembolic protection are not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has not improved sufficiently despite the availability of direct oral anticoagulants which are associated with less major bleeding than vitamin K antagonists. Multiple reasons account for this, including bleeding events or ischaemic strokes whilst on anticoagulation, a serious risk of bleeding events, poor treatment compliance despite best educational attempts, or aversion to drug therapy. An alternative interventional therapy, which is not associated with long-term bleeding and is as effective as vitamin K anticoagulation, was introduced over 20 years ago. Because of significant improvements in procedural safety over the years, left atrial appendage closure, predominantly achieved using a catheter-based, device implantation approach, is increasingly favoured for the prevention of thromboembolic events in patients who cannot achieve effective anticoagulation. This management strategy is well known to the interventional cardiologist/electrophysiologist but is not more widely appreciated within cardiology or internal medicine. This article introduces the devices and briefly explains the implantation technique. The indications and device follow-up are more comprehensively described. Almost all physicians who care for adult patients will have many with AF. This practical guide, written within guideline/guidance boundaries, is aimed at those non-implanting physicians who may need to refer patients for consideration of this new therapy, which is becoming increasingly popular.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Médicos , Accidente Cerebrovascular , Tromboembolia , Adulto , Humanos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Cierre del Apéndice Auricular Izquierdo , Consenso , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Anticoagulantes/efectos adversos , Tromboembolia/etiología , Tromboembolia/prevención & control , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Vitamina K , Apéndice Atrial/cirugía , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493490

RESUMEN

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Asunto(s)
Miocarditis , Sarcoidosis , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones , Medios de Contraste , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/epidemiología , Gadolinio , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética/efectos adversos , Miocarditis/complicaciones , Pronóstico , Medición de Riesgo , Factores de Riesgo , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda
6.
Europace ; 26(1)2023 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-38245007

RESUMEN

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Anciano , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Puntaje de Propensión , Resultado del Tratamiento , Atrios Cardíacos , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
7.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37378419

RESUMEN

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Asunto(s)
Vena Axilar , Incisión Venosa , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Vena Axilar/cirugía , Incisión Venosa/métodos , Vena Subclavia , Punciones/métodos , Corazón
8.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37846769

RESUMEN

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Criocirugía/métodos , Italia/epidemiología , Sistema de Registros , Ablación por Catéter/métodos , Recurrencia
9.
J Ultrasound Med ; 42(2): 497-512, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35727082

RESUMEN

The hook of hamate is a complex anatomical region with many small but important structures. A sound knowledge of anatomy along with a systematic ultrasound technique can help delineate a variety of disorders. In this pictorial review, we discuss the ultrasound anatomy and the possible pathologies that can be encountered in this region.


Asunto(s)
Fracturas Óseas , Hueso Ganchoso , Humanos , Hueso Ganchoso/diagnóstico por imagen , Ultrasonografía , Extremidad Superior
10.
Int J Mol Sci ; 24(1)2023 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-36614271

RESUMEN

The use of degrading enzymes in polymer formulation is a very attractive strategy to manage the end-of-life of plastics. However, high temperatures cause the denaturation of enzymes and the loss of their catalytic activity; therefore, protection strategies are necessary. Once protected, the enzyme needs to be released in appropriate media to exert its catalytic activity. A successful protection strategy involves the use of layered double hydroxides: cutinase, selected as a highly degrading polyester hydrolytic enzyme, is thermally protected by immobilization in Mg/Al layered double hydroxide structures. Different triggering media are here evaluated in order to find the best releasing conditions of cutinase from LDH. In detail, phosphate and citrate-phosphate buffers, potassium carbonate, sodium chloride, and sodium sulfate solutions are studied. After the comparison of all media in terms of protein release and activity retained, phosphate buffer is selected as the best candidate for the release of cutinase from LDH, and the effect of pH and concentration is also evaluated. The amount of the enzyme released is determined with the Lowry method. Activity tests are performed via spectrophotometry.


Asunto(s)
Hidróxidos , Polímeros , Hidróxidos/química , Fosfatos
11.
Int J Mol Sci ; 24(3)2023 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-36768812

RESUMEN

Variants in desmoplakin gene (DSP MIM *125647) have been usually associated with Arrhythmogenic Cardiomyopathy (ACM), or Dilated Cardiomyopathy (DCM) inherited in an autosomal dominant manner. A cohort of 18 probands, characterized as heterozygotes for DSP variants by a target Next Generation Sequencing (NGS) cardiomyopathy panel, was analyzed. Cardiological, genetic data, and imaging features were retrospectively collected. A total of 16 DSP heterozygous pathogenic or likely pathogenic variants were identified, 75% (n = 12) truncating variants, n = 2 missense variants, n = 1 splicing variant, and n = 1 duplication variant. The mean age at diagnosis was 40.61 years (IQR 31-47.25), 61% of patients being asymptomatic (n = 11, New York Heart Association (NYHA) class I) and 39% mildly symptomatic (n = 7, NYHA class II). Notably, 39% of patients (n = 7) presented with a clinical history of presumed myocarditis episodes, characterized by chest pain, myocardial enzyme release, 12-lead electrocardiogram abnormalities with normal coronary arteries, which were recurrent in 57% of cases (n = 4). About half of the patients (55%, n = 10) presented with a varied degree of left ventricular enlargement (LVE), four showing biventricular involvement. Eleven patients (61%) underwent implantable cardioverter defibrillator (ICD) implantation, with a mean age of 46.81 years (IQR 36.00-64.00). Cardiac magnetic resonance imaging (CMRI) identified in all 18 patients a delayed enhancement (DE) area consistent with left ventricular (LV) myocardial fibrosis, with a larger localization and extent in patients presenting with recurrent episodes of myocardial injury. These clinical and genetic data confirm that DSP-related cardiomyopathy may represent a distinct clinical entity characterized by a high arrhythmic burden, variable degrees of LVE, Late Gadolinium Enhancement (LGE) with subepicardial distribution and episodes of myocarditis-like picture.


Asunto(s)
Cardiomiopatías , Miocarditis , Adulto , Humanos , Persona de Mediana Edad , Cardiomiopatías/etiología , Cardiomiopatías/genética , Medios de Contraste , Gadolinio , Hipertrofia Ventricular Izquierda , Estudios Retrospectivos
12.
J Cardiovasc Electrophysiol ; 33(7): 1414-1424, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35524404

RESUMEN

INTRODUCTION: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system. METHODS: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity. The Lumipoint™ (Boston Scientific) map-analysis tool was used sequentially on each PV component. The ablation endpoint was PV isolation (PVI) and electrical quiescence in the antral region. RESULTS: Fifty-eight cases of AF ablation were analyzed. A total of 86 PVGs in 34 (58.6%) patients and 44 RAPs in 34 patients (58.6%) were found. In 16 (27.6%) cases, we found at least one RAP in patients with complete absence of PV conduction. RAPs showed a lower mean voltage than PVG (0.3 ± 0.2 mV vs. 0.7 ± 0.5 mV, p < .0001), whereas the mean number of electrogram peaks was higher (8.4 ± 1.4 vs. 3.2 ± 1.5, p < .0001). The percentage of patients in whom RAPs were detected through Lumipoint™ was higher than through propagation map analysis (58.6% vs. 36.2%, p = .025). Acute procedural success was 100%, with all PVs successfully isolated and RAPs completely abolished in all study patients. During a mean follow-up of 453 ± 133 days, 6 patients (10.3%) suffered an AF/AT recurrence. CONCLUSION: Local vulnerabilities in antral lesion sets were easily discernible by means of the UHDM system in both de novo and redo patients when no PV conduction was present.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Sistema de Registros , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 45(12): 1409-1414, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36214206

RESUMEN

INTRODUCTION: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). OBJECTIVE: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. METHODS AND RESULTS: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. CONCLUSION: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Niño , Humanos , Desfibriladores Implantables/efectos adversos , Adolescente , Muerte Súbita Cardíaca/prevención & control
14.
Nutr Metab Cardiovasc Dis ; 32(2): 456-468, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34893411

RESUMEN

BACKGROUND AND AIMS: To compare biventricular and biatrial myocardial strain indices assessed by two-dimensional speckle tracking echocardiography (2D-STE) in women with gestational diabetes mellitus (GDM) and those with uncomplicated pregnancy at the third trimester of pregnancy and in post-partum. METHODS AND RESULTS: 30 consecutive GDM women and 30 age-, ethnicity- and gestational week-matched controls without any comorbidity were examined in this prospective case-control study. All women underwent obstetric visit, blood tests and transthoracic echocardiography (TTE) implemented with 2D-STE analysis of all cardiac chambers at 36-38 weeks' gestation. TTE and 2D-STE were repeated at 6-10 weeks after delivery. At 36-38 weeks' gestation, GDM women, compared to controls, had significantly higher body mass index (BMI), blood pressure values and inflammatory markers. TTE showed increased left ventricular (LV) mass and impaired LV diastolic function in GDM women, whereas there was no significant difference between the groups in ejection fraction. 2D-STE revealed that biventricular global longitudinal strain (GLS) and biatrial reservoir strain indices were significantly lower in GDM women than controls. Third trimester BMI was inversely correlated with LV-GLS (r = -0.86) and was independently associated with reduced LV-GLS (less negative than -20%) in GDM women in post-partum (OR 1.81, 95%CI 1.14-2.89). A BMI value ≥ 30 kg/m2 had 100% sensitivity and 99.5% specificity for identifying GDM women with impaired LV-GLS in post-partum (AUC = 0.97). CONCLUSION: Women with GDM, compared to women with uncomplicated pregnancy, have significantly lower biventricular and biatrial myocardial deformation indices. These abnormalities may be persistent in post-partum in GDM women with obesity.


Asunto(s)
Diabetes Gestacional , Hiperglucemia , Estudios de Casos y Controles , Diabetes Gestacional/diagnóstico por imagen , Ecocardiografía/métodos , Femenino , Humanos , Obesidad/diagnóstico , Obesidad/diagnóstico por imagen , Embarazo , Reproducibilidad de los Resultados , Función Ventricular Izquierda
15.
Acta Radiol ; 63(11): 1522-1527, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34842472

RESUMEN

BACKGROUND: Several disorders may result in forefoot pain. An uncommon cause of forefoot pain is subcutaneous plantar veins thrombosis (SCPVT) involving veins superficial to the plantar fascia. PURPOSE: To describe the ultrasound (US) appearance of SCPVT, which has been described only once in the radiological literature. MATERIAL AND METHODS: We performed a retrospective search of our PACS system from 2016 to 2020 to collect all cases of US-diagnosed SCPVT. We collected data on seven patients. Two radiologists analyzed the US images retrieved. All US examinations were performed with a multifrequency linear probe (frequencies in the range of 5-17 MHz). RESULTS: A localized plantar nodule was palpable in 86% of patients. The subcutaneous thrombosed vein appeared in all patients as a round or ovoid nodule located in the subcutaneous tissues that corresponded in four patients (4/5, 80%) to the painful palpable nodule. The size was in the range of 4-7 mm (mean = 5.4 mm). The thrombosed vein presented a connection with adjacent patent veins, appeared enlarged, and almost filled with hypo-isoechoic material, and in two patients (2/7, 29%), a thin peripheral fluid component surrounding the thrombus was detectable. Continuous scanning demonstrated slow blood movements inside the peripheral component due to blood circulation. Failure to compress the lumen of the thrombosed vein during the real-time US was evident in all patients. CONCLUSION: SCPVT is a rare or underreported condition. Sonologists must know the US appearance of SCPVT to exclude other conditions and avoid unnecessary invasive studies.


Asunto(s)
Trombosis , Trombosis de la Vena , Humanos , Dolor , Estudios Retrospectivos , Tejido Subcutáneo/diagnóstico por imagen , Trombosis/complicaciones , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen
16.
Eur Heart J Suppl ; 24(Suppl I): I22-I24, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36380801

RESUMEN

Heart failure and atrial fibrillation are two diseases that often coexist and contribute to worsening the prognosis and quality of life of patients. Managing this situation is still a challenge today. The ablation of the atrioventricular node associated with cardiac resynchronization therapy (CRT) fits into this context as a definitive but effective solution. Indeed, long-term positive results have been demonstrated in patients with atrial fibrillation ineligible for ablation and refractory to medical therapy in terms of symptom reduction and, more recently, also mortality. Furthermore, the role of this strategy in obtaining adequate biventricular pacing in patients who may benefit from CRT but are ineligible due to the presence of atrial fibrillation is being highlighted.

17.
J Ultrasound Med ; 41(3): 763-771, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34037265

RESUMEN

Ultrasound enables the accurate assessment of traumatic disorders of small peripheral nerves of extremities. Human nerve allografts and nerve conduits are increasingly used for the surgical treatment of nerve trauma but ultrasound reports on this field are scarce in the radiological literature. We present the macroscopic and in vitro ultrasound appearance of human allografts, and synthetic and biological conduits. In addition, we describe the ultrasound findings in some patients operated upon using the same devices. The in vitro ultrasound appearance correlated well with the macroscopic appearance of the devices. Awareness of their appearance in vitro can help sonologists when examining postsurgical patients.


Asunto(s)
Traumatismos de los Nervios Periféricos , Aloinjertos , Humanos , Regeneración Nerviosa , Traumatismos de los Nervios Periféricos/diagnóstico por imagen , Traumatismos de los Nervios Periféricos/cirugía , Nervios Periféricos/diagnóstico por imagen , Prótesis e Implantes
18.
J Cardiovasc Electrophysiol ; 32(5): 1296-1304, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33783875

RESUMEN

BACKGROUND: No data exist on the ability of the novel Rhythmia 3-D mapping system to minimize fluoroscopy exposure during transcatheter ablation of arrhythmias. We report data on the feasibility and safety of a minimal fluoroscopic approach using this system in supraventricular tachycardia (SVT) procedures. METHODS: Consecutive patients were enrolled in the CHARISMA registry at 12 centers. All right-sided procedures performed with the Rhythmia mapping system were analyzed. The acquired electroanatomic information was used to reconstruct 3-D cardiac geometry; fluoroscopic confirmation was used whenever deemed necessary. RESULTS: Three hundred twenty-five patients (mean age = 56 ± 17 years, 57% male) were included: 152 atrioventricular nodal reentrant tachycardia, 116 atrial flutter, 41 and 16 right-sided accessory pathway and atrial tachycardia, respectively. Overall, 27 481 s of fluoroscopy were used (84.6 ± 224 s per procedure, equivalent effective dose = 1.1 ± 3.7 mSv per patient). One hundred ninety-two procedures (59.1%) were completed without the use of fluoroscopy (zero fluoroscopy, ZF). In multivariate analysis, the presence of a fellow in training (OR = 0.15, 95% CI: 0.05-0.46; p = .0008), radiofrequency application (0.99, 0.99-1.00; p = .0002), and mapping times (0.99, 0.99-1.00; p = .042) were all inversely associated with ZF approach. Acute procedural success was achieved in 97.8% of the cases (98.4 vs. 97% in the ZF vs. non-ZF group; p = .4503). During a mean of 290.7 ± 169.6 days follow-up, no major adverse events were reported, and recurrence of the primary arrhythmia was 2.5% (2.1 vs. 3% in the ZF vs. non-ZF group; p = .7206). CONCLUSIONS: The Rhythmia mapping system permits transcatheter ablation of right-sided SVT with minimal fluoroscopy exposure. Even more, in most cases, the system enables a ZF approach, without affecting safety and efficacy.


Asunto(s)
Ablación por Catéter , Taquicardia Supraventricular , Adulto , Anciano , Ablación por Catéter/efectos adversos , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Taquicardia Supraventricular/diagnóstico por imagen , Taquicardia Supraventricular/cirugía , Resultado del Tratamiento
19.
Pacing Clin Electrophysiol ; 44(1): 63-70, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33210304

RESUMEN

BACKGROUND: Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. AIM OF THE STUDY: The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). METHODS: We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX-EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new "occlusion tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. RESULTS: A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 ± 17 minutes. Mean fluoroscopy time was 6 ± 2 minutes. No 30-day complications were observed. CONCLUSION: The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Venas Pulmonares/cirugía , Programas Informáticos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco , Angiografía Coronaria , Criocirugía/instrumentación , Mapeo Epicárdico , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Sensibilidad y Especificidad
20.
Semin Musculoskelet Radiol ; 25(2): 346-354, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34374068

RESUMEN

The unique anatomical characteristics of the thumb offer a broad range of motion and the ability to oppose thumb and finger, an essential function for grasping. The motor function of the thumb and its orientation make it particularly vulnerable to trauma. Pathologic lesions encountered in this joint are varied, and imaging techniques play a crucial role in injury detection and characterization. Despite advances in diagnostic accuracy, acute thumb injuries pose a challenge for the radiologist. The complex and delicate anatomy requires meticulous and technically flawless image acquisition. Standard radiography and ultrasonography are currently the most frequently used imaging techniques. Computed tomography is most often indicated for complex fractures and dislocations, and magnetic resonance imaging may be useful in equivocal cases. In this article, we present the relevant anatomy and imaging techniques of the thumb.


Asunto(s)
Traumatismos de los Dedos , Fracturas Óseas , Traumatismos de la Mano , Luxaciones Articulares , Fracturas Óseas/diagnóstico por imagen , Humanos , Pulgar/diagnóstico por imagen , Pulgar/lesiones , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA