Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Int J Mol Sci ; 23(19)2022 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-36233300

RESUMEN

The quality of the lubricant between cartilaginous joint surfaces impacts the joint's mechanistic properties. In this study, we define the biochemical, ultrastructural, and tribological signatures of synovial fluids (SF) from patients with degenerative (osteoarthritis-OA) or inflammatory (rheumatoid arthritis-RA) joint pathologies in comparison with SF from healthy subjects. Phospholipid (PL) concentration in SF increased in pathological contexts, but the proportion PL relative to the overall lipids decreased. Subtle changes in PL chain composition were attributed to the inflammatory state. Transmission electron microscopy showed the occurrence of large multilamellar synovial extracellular vesicles (EV) filled with glycoprotein gel in healthy subjects. Synovial extracellular vesicle structure was altered in SF from OA and RA patients. RA samples systematically showed lower viscosity than healthy samples under a hydrodynamic lubricating regimen whereas OA samples showed higher viscosity. In turn, under a boundary regimen, cartilage surfaces in both pathological situations showed high wear and friction coefficients. Thus, we found a difference in the biochemical, tribological, and ultrastructural properties of synovial fluid in healthy people and patients with osteoarthritis and arthritis of the joints, and that large, multilamellar vesicles are essential for good boundary lubrication by ensuring a ball-bearing effect and limiting the destruction of lipid layers at the cartilage surface.


Asunto(s)
Cartílago Articular , Vesículas Extracelulares , Osteoartritis , Glicoproteínas/análisis , Humanos , Lubricantes , Fosfolípidos/análisis , Líquido Sinovial/química
2.
Nanomedicine ; 12(1): 191-200, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26370708

RESUMEN

The storage and catabolism of Ultrasmall SuperParamagnetic Iron Oxide (USPIO) nanoparticles were analyzed through a multiscale approach combining Two Photon Laser Scanning Microscopy (TPLSM) and High-Resolution Transmission Electron Microscopy (HRTEM) at different times after intravenous injection in an atherosclerotic ApoE(-/-) mouse model. The atherosclerotic plaque features and the USPIO heterogeneous biodistribution were revealed down from organ's scale to subcellular level. The biotransformation of the nanoparticle iron oxide (maghemite) core into ferritin, the non-toxic form of iron storage, was demonstrated for the first time ex vivo in atherosclerotic plaques as well as in spleen, the iron storage organ. These results rely on an innovative spatial and structural investigation of USPIO's catabolism in cellular phagolysosomes. This study showed that these nanoparticles were stored as non-toxic iron compounds: maghemite oxide or ferritin, which is promising for MRI detection of atherosclerotic plaques in clinics using these USPIOs. From the Clinical Editor: Advance in nanotechnology has brought new contrast agents for clinical imaging. In this article, the authors investigated the use and biotransformation of Ultrasmall Super-paramagnetic Iron Oxide (USPIO) nanoparticles for analysis of atherosclerotic plagues in Two Photon Laser Scanning Microscopy (TPLSM) and High-Resolution Transmission Electron Microscopy (HRTEM). The biophysical data generated from this study could enable the possible use of these nanoparticles for the benefits of clinical patients.


Asunto(s)
Dextranos/farmacocinética , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patología , Fracciones Subcelulares/metabolismo , Fracciones Subcelulares/patología , Animales , Medios de Contraste/farmacocinética , Nanopartículas de Magnetita , Ensayo de Materiales , Tasa de Depuración Metabólica , Metabolismo , Ratones , Ratones Endogámicos C57BL , Microscopía Electrónica de Transmisión/métodos , Microscopía de Fluorescencia por Excitación Multifotónica/métodos , Placa Aterosclerótica/ultraestructura , Fracciones Subcelulares/ultraestructura , Distribución Tisular
3.
Biomed Microdevices ; 17(4): 66, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26044201

RESUMEN

With the continuing development of nanomaterials, the assessment of their potential impact on human health, and especially human reproductive toxicity, is a major issue. The testicular biodistribution of nanoparticles remains poorly studied. This study investigated whether gold-silica nanoparticles could be detected in mouse testes after intramuscular injection, with a particular focus on their ability to cross the blood-testis barrier. To that purpose, well-characterized 70-nm gold core-silica shell nanoparticles were used to ensure sensitive detection using high-resolution techniques. Testes were collected at different time points corresponding to spermatogenesis stages in mice. Transmission electron microscopy and confocal microscopy were used for nanoparticle detection, and nanoparticle quantification was performed by atomic emission spectroscopy. All these techniques showed that no particles were able to reach the testes. Results accorded with the normal histological appearance of testes even at 45 days post sacrifice. High-resolution techniques did not detect 70-nm silica-gold nanoparticles in mouse testes after intramuscular injection. These results are reassuring about the safety of nanoparticles with regard to male human reproduction, especially in the context of nanomedicine.


Asunto(s)
Oro/farmacocinética , Nanopartículas del Metal/química , Dióxido de Silicio/farmacocinética , Testículo/efectos de los fármacos , Animales , Inyecciones Intramusculares , Masculino , Ratones , Ratones Endogámicos C57BL , Microscopía Confocal , Microscopía Electrónica de Transmisión , Tamaño de la Partícula , Espermatogénesis/efectos de los fármacos , Testículo/metabolismo , Distribución Tisular
4.
Microsc Microanal ; 20(3): 903-11, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24641871

RESUMEN

A better knowledge of synovial fluid (SF) ultrastructure is required to further understand normal joint lubrication and metabolism. The aim of the present study was to elucidate SF structural features in healthy joints from three mammalian species of different size compared with features in biomimetic SF. High-resolution structural analysis was performed using transmission electron microscopy (TEM) and scanning electron microscopy (SEM) and environmental SEM/wet scanning transmission electron microscopy mode complemented by TEM and SEM cryogenic methods. Laser-scanning confocal microscopy (LCM) was used to locate the main components of SF with respect to its ultrastructural organization. The present study showed that the ultrastructure of healthy SF is built from a network of vesicles with a size range from 100 to a few hundred nanometers. A multilayered organization of the vesicle membranes was observed with a thickness of about 5 nm. LCM study of biological SF compared with synthetic SF showed that the microvesicles consist of a lipid-based membrane enveloping a glycoprotein gel. Thus, healthy SF has a discontinuous ultrastructure based on a complex network of microvesicles. This finding offers novel perspectives for the diagnosis and treatment of synovial joint diseases.


Asunto(s)
Líquido Sinovial , Vesículas Transportadoras/ultraestructura , Animales , Perros , Caballos , Articulaciones/fisiología , Microscopía Confocal , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión de Rastreo , Microscopía Electrónica de Transmisión , Ratas , Vesículas Transportadoras/química
5.
Nanotechnology ; 21(39): 395103, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20820094

RESUMEN

The unique magnetic properties of iron oxide nanoparticles have paved the way for various biomedical applications, such as magnetic resonance cellular imaging or magnetically induced therapeutic hyperthermia. Living cells interact with nanoparticles by internalizing them within intracellular acidic compartments. Although no acute toxicity of iron oxide nanoparticles has been reported up to now, the mechanisms of nanoparticle degradation by the cellular environment are still unknown. In the organism, the long term integrity and physical state of iron-based nanoparticles are challenged by iron homeostasis. In this study, we monitored the degradation of 7 nm sized maghemite nanoparticles in a medium mimicking the intracellular environment. Magnetic nanoparticles with three distinct surface coatings, currently evaluated as MRI contrast agents, were shown to exhibit different kinetics of dissolution at an acidic pH in the presence of a citrate chelating agent. Our assessment of the physical state of the nanoparticles during degradation revealed that the magnetic properties, size distribution and structure of the remaining nanocrystals were identical to those of the initial suspension. This result suggests a model for nanoparticle degradation with rapidly dissolved nanocrystals and a reservoir of intact nanoparticles.


Asunto(s)
Medios de Contraste/metabolismo , Lisosomas/metabolismo , Nanopartículas de Magnetita/ultraestructura , Modelos Biológicos , Modelos Químicos , Citratos , Medios de Contraste/química , Compuestos Férricos , Concentración de Iones de Hidrógeno , Lisosomas/química , Imagen por Resonancia Magnética , Nanopartículas de Magnetita/química , Tamaño de la Partícula , Citrato de Sodio , Propiedades de Superficie , Temperatura , Factores de Tiempo
6.
Appl Radiat Isot ; 125: 134-138, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28431338

RESUMEN

Long term in situ diffusion experiments in the Callovian-Oxfordian mudstone (France) are designed in the context of nuclear waste management. ß-emitters HTO and 36Cl radiotracers are representative of neutral and anionic species in these experiments. Studies have been carried out to design an in situ beta monitoring system in order to quantify tracer migration in the rock pore water over time. The development, design and calibration of ß-emitter radiation sensors were performed. An optimised geometry was calculated for the detection chamber of 36Cl in solution (Ø×L=30×2mm2) via Monte-Carlo N-Particle transport simulation tools. A better SNR (Signal to Noise Ratio) was obtained with YSO cylindrical crystal (Ø×L=6.5×0.5mm2). A sensitivity of 0.21cpm/Bq/mL was measured using 36Cl standards. The 36Cl detection limits were 18Bq/mL and 14.2Bq/mL after 1h and 24h of accumulation time respectively. Such beta sensors, placed 350mm from the radiotracer injection borehole, could successfully discriminate 36Cl anisotropic diffusion in various directions within 4 years. It will be tested in situ and can be adapted to other in situ experience.

7.
Eur J Pharm Biopharm ; 60(1): 123-31, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15848064

RESUMEN

This work describes the synthesis of new amphiphilic perfluorohexyl- and perfluorooctyl-propanethio-beta-cyclodextrins and the comparison of the ability of these molecules and alkyl analogue, nonanethio-beta-cyclodextrin to form nanospheres. Nanospheres were prepared using nanoprecipitation method (perfluoroalkylthio-beta-cyclodextrin in THF [0.11 x 10(-3)M], stirring rate 700rpm, addition of aqueous phase at 64 degrees C into organic phase at 50 degrees C). They were characterised by Photon Correlation Spectroscopy (PCS) and by electron microscopy (SEM and cryo-TEM). The nanospheres prepared from these new beta-cyclodextrin derivatives have an average size of 260nm, and appear to be spherical in cryo-TEM images. Whereas alkyl analogue forms polydisperse aggregates with sizes in the range 60-350nm.


Asunto(s)
beta-Ciclodextrinas/química , Alquilación , Microscopía por Crioelectrón , Estabilidad de Medicamentos , Excipientes , Liofilización , Espectroscopía de Resonancia Magnética , Microesferas , Tamaño de la Partícula
8.
Microsc Microanal ; 15(1): 15-9, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19144253

RESUMEN

We present a fast and simple method to prepare specimens for transmission electron microscopy studies of oxide thin films deposited on silicon substrates. The method consists of scratching the film surface using a pointed diamond tip, in a special manner. Small and thin fragments are then detached from the film and its substrate. Depending on the scratching direction, the fragments can be used for plan-view or cross-section imaging. High-resolution images can be also obtained from thin edges of the film fragments. The method is demonstrated in the case of HfO2 sol-gel films deposited on [100] Si wafer substrates.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA