Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Electrophoresis ; 36(20): 2606-15, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26200811

RESUMEN

The separation of eight antibiotics belonging to 5-nitroimidazole family was carried out by means of CEC coupled with MS. Preliminary experiments were carried out with ultraviolet detection in order to select the proper stationary and mobile phase. Among the different stationary phases studied (namely Lichrospher C18, 5 µm particle size; Cogent(TM) Bidentate C18, 4.2 µm; Pinnacle II™ Phenyl, 3 µm; Pinnacle II™ Cyano, 3 µm), Cogent™ Bidentate C18 (4.2 µm) gave the best performance. For CEC-MS coupling, a laboratory assembled liquid-junction-nano-spray interface was used. In order to achieve a good sensitivity, special attention was paid to both optimization of the sheath liquid composition as well as selection of the injection mode. Under optimized CEC-ESI-MS conditions, the separation was accomplished within 22 min by using a column packed with a mixture of Bidentate C18:Lichrospher Silica-60 (5 µm) 3:1 w/w, an inlet pressure of 11 bar, a voltage of 15 kV, and a mobile phase composed by 45:10:45 v/v/v ACN/MeOH/water containing ammonium acetate (5 mM pH 5). A combined hydrodynamic and electrokinetic injection of 8 bar, 15 kV, and 96 s was adopted. The method was validated in terms of repeatability and intermediate precision of retention times and peak areas, linearity, and LODs and LOQs. RSDs values were <2.9% for retention times and <16.1% for peak areas in both intraday and interday experiments. LOQ values were between 0.09 and 0.42 µg/mL for all compounds. Finally, the method was applied to the determination of three most employed 5-nitroimidazole antibiotics (metronidazole, secnidazole, and ternidazole) in spiked urine samples, subjected to a SPE procedure. Recovery values in the 67-103% range were obtained. Furthermore, for the selected antibiotics, CEC-MS(2) spectra were obtained providing the unambiguous confirmation of these drugs in urine samples.


Asunto(s)
Antibacterianos/orina , Electrocromatografía Capilar/métodos , Espectrometría de Masas/métodos , Nitroimidazoles/orina , Humanos , Modelos Lineales , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Biomed Chromatogr ; 18(8): 608-12, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15386509

RESUMEN

A very rapid and simple MEKC method was developed for the simultaneous determination of four antiepileptic drugs, ethosuximide (Etho), primidone (Pri), phenytoin (Pht) and carbamazepine (Cbz) in human serum. Sample analysis required only 100 microL of human serum which only needed to be centrifuged, decanted and combined with the running buffer [5.3 mM Na(2)HPO(4)/3.2 mM borax buffer (pH 9.5) containing 55 mM SDS and 3.5% (v/v) acetone]. The analysis was performed in only 10 min into fused-silica capillaries (57 cm total length with 50 microm i.d. and 50 cm to the detector) using the MEKC methodology with diode-array detection at 220 nm. The calibration graphs were established for ethoximide, primidone, phenytoin and carbamazepine between 0 and 20 mg/L. Recoveries were between 85 and 87%. The simplicity of the proposed methodology makes it suitable for routine clinical use, especially for epileptic patients on polytherapy.


Asunto(s)
Anticonvulsivantes/sangre , Cromatografía Capilar Electrocinética Micelar/métodos , Tampones (Química) , Carbamazepina/sangre , Etosuximida/sangre , Humanos , Concentración de Iones de Hidrógeno , Concentración Osmolar , Fenitoína/sangre , Primidona/sangre , Control de Calidad , Sensibilidad y Especificidad , Dodecil Sulfato de Sodio
3.
Biomed Chromatogr ; 18(7): 422-6, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15340966

RESUMEN

In this work, a sub-minute and sensitive capillary electrophoresis with laser-induced fluorescence (CE-LIF) method was developed for the analysis and quantitation of the neurotransmitter 5-hydroxytryptamine (5-HT) or serotonin in urine. The method involves precolumn derivatization with fluorescein isothiocyanate isomer I (FITC) using an excitation light from an argon ion laser of 488 nm and a 520 nm band pass emission filter. Different variables that affect derivatization (pH, FITC concentration, reaction time and temperature) and separation (buffer concentration, pH, applied voltage and injection time) were studied. The linear dynamic range obtained was between 0 and 188 nM with a detection limit of 16 nm with a RSD between 2 and 9%. The applicability of the proposed method was demonstrated by analysis of 5-HT in human urine, establishing a concentration of 57 nM in control urine. The method was validated by standard-addition methodology.


Asunto(s)
Electroforesis Capilar/métodos , Serotonina/orina , Espectrometría de Fluorescencia/métodos , Calibración , Humanos , Rayos Láser , Mediciones Luminiscentes , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA