Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 273
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38197587

RESUMEN

OBJECTIVE: Giant Cell arteritis (GCA) is a large vessel vasculitis, typically involving the aorta and its branches with predilection for the scalp arteries. Intracranial involvement is still part of ongoing research. We assess inflammation of the intracranial arteries on 3D-black-blood magnetic resonance imaging (3D-CS-BB-MRI) in patients with GCA and age-matched controls. METHODS: 105 patients with 3D-CS-BB-MRI of the brain were included in this retrospective dual-center case-control study; 55 with diagnosed GCA and 50 age-matched controls. High-resolution 3D-CS-BB-MRI was performed on a 3 Tesla MR scanner with a post-contrast 3D-compressed-sensing (CS) MR pulse sequence, specifically a T1-weighted sampling perfection, application-optimized contrasts using different flip angle evolution (SPACE) pulse sequence with whole-brain coverage and isotropic resolution of 0.55 mm3. Two neuroradiologists blinded to clinical data independently scored the cerebral arteries qualitatively for inflammation; circumferential vessel wall thickening and contrast enhancement were scored positive for vasculitis. RESULTS: 8 of 55 GCA patients (14.5%) showed inflammation of at least one intracranial artery. The internal carotid artery (ICA) was affected in 6/55 (10.9%), the vertebral artery in 4/55 (7.3%) and the basilar artery and posterior cerebral artery in 1/55 (1.8%). All patients with inflammatory changes reported headaches and none showed any focal neurological deficit. Besides headache and general weakness, there was no significant correlation between inflammation of the intracranial arteries and clinical symptoms. No age-matched control patient showed inflammatory changes of the intracranial arteries. CONCLUSION: High-resolution 3D-CS-BB-MRI revealed inflammatory changes of intracranial arteries in 14.5% of GCA patients with the intradural ICA as the most frequently affected vessel.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38305463

RESUMEN

OBJECTIVES: Our aim was to introduce a standardized system for assessing the extent of giant cell arteritis (GCA) on MRI, titled MRVAS (MR Vasculitis Activity score). To obtain a comprehensive view, we used an extensive MRI protocol including cranial vessels and the aorta with its branches. To test reliability, MRI was assessed by 4 readers with different levels of experience. METHODS: 80 patients with suspected GCA underwent MRI of cranial arteries and the aorta/branches (20 vessel segments). Every vessel was rated dichotomous [inflamed (coded as 1) or not 0], providing a summed score from 0 to 20. Blinded readers (two experienced radiologists [ExR], two inexperienced radiologists [InR]) applied the MRVAS on an individual vessel and an overall level (defined as the highest score of any of the individual vessel scores). To determine interrater agreement, Cohen's kappa was calculated for pairwise comparison of each reader for individual vessel segments. Intraclass correlation coefficients (ICC) were used for the MRVAS score. RESULTS: Concordance rates were excellent for both sub-cohorts on an individual vessel-based (GCA, ICC, 0.95; and non-GCA, ICC, 0.96) and Overall MRVAS score level (GCA, ICC, 0.96; and non-GCA, ICC, 1.0). Interrater agreement yielded significant concordance (p< 0.001) for all pairs (kappa range 0.78-0.98). No significant differences between ERs and IRs were observed (p= 0.38). CONCLUSION: The proposed MRVAS score allows standardized scoring of inflammation in GCA and achieved high agreement rates in a prospective setting.

3.
AJR Am J Roentgenol ; 222(2): e2330154, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37966036

RESUMEN

BACKGROUND. Dual-energy CT pulmonary angiography (CTPA) with energy-integrating detector (EID) technology is limited by the inability to use high-pitch technique. OBJECTIVE. The purpose of this study was to compare the image quality of anatomic images and iodine maps between high-pitch photon-counting detector (PCD) CTPA and dual-energy EID CTPA. METHODS. This prospective study included 117 patients (70 men and 47 women; median age, 65 years) who underwent CTPA to evaluate for pulmonary embolism between March 2022 and November 2022. Fifty-eight patients were randomized to undergo PCD CTPA (pitch, 2.0), and 59 were randomized to undergo EID CTPA (pitch, 0.55). For each examination, 120-kV polychromatic images, 60-keV virtual monogenetic images (VMIs), and iodine maps were reconstructed. One radiologist measured CNR and SNR. Three radiologists independently assessed subjective image quality (on a scale of 1-4, with a score of 1 denoting highest quality). Radiation dose was recorded. RESULTS. SNR and CNR were higher for PCD CTPA than for EID CTPA for polychromatic images and VMIs, for all assessed vessels other than the left upper lobe artery. For example, for PCD CTPA versus EID CTPA, the right lower lobe artery on polychromatic images had an SNR of 34.5 versus 28.0 (p = .003) and a CNR of 29.2 versus 24.4 (p = .001), and on VMIs it had an SNR of 43.2 versus 32.7 (p = .005) and a CNR of 37.4 versus 29.3 (p = .002). For both scanners for readers 1 and 2, the median image quality score for polychromatic images and VMIs was 1, although distributions indicated significantly better scores for PCD CTPA than for EID CTPA for polychromatic images for reader 1 (p = .02) and reader 2 (p = .005) and for VMIs for reader 1 (p = .001) and reader 2 (p = .006). The image quality of anatomic image sets was not different between PCD CTPA and EID CTPA for reader 3 (p > .05). The image quality of iodine maps was not different between PCD CTPA and EID CTPA for any reader (p > .05). For PCD CTPA versus EID CTPA, the CTDIvol was 3.9 versus 4.5 mGy (p = .03), and the DLP was 123.5 mGy × cm versus 157.0 mGy × cm (p < .001). CONCLUSION. High-pitch PCD CTPA provided anatomic images with better subjective and objective image quality versus dual-energy EID CTPA, with lower radiation dose. Iodine maps showed no significant difference in image quality between scanners. CLINICAL IMPACT. CTPA may benefit from the PCD CT technique.


Asunto(s)
Yodo , Masculino , Humanos , Femenino , Anciano , Estudios Prospectivos , Fotones , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Dosis de Radiación
4.
BMC Med Imaging ; 24(1): 49, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38395772

RESUMEN

PURPOSE: Unenhanced abdominal CT constitutes the diagnostic standard of care in suspected urolithiasis. Aiming to identify potential for radiation dose reduction in this frequent imaging task, this experimental study compares the effect of spectral shaping and tube voltage modulation on image quality. METHODS: Using a third-generation dual-source CT, eight cadaveric specimens were scanned with varying tube voltage settings with and without tin filter application (Sn 150, Sn 100, 120, 100, and 80 kVp) at three dose levels (3 mGy: standard; 1 mGy: low; 0.5 mGy: ultralow). Image quality was assessed quantitatively by calculation of signal-to-noise ratios (SNR) for various tissues (spleen, kidney, trabecular bone, fat) and subjectively by three independent radiologists based on a seven-point rating scale (7 = excellent; 1 = very poor). RESULTS: Irrespective of dose level, Sn 100 kVp resulted in the highest SNR of all tube voltage settings. In direct comparison to Sn 150 kVp, superior SNR was ascertained for spleen (p ≤ 0.004) and kidney tissue (p ≤ 0.009). In ultralow-dose scans, subjective image quality of Sn 100 kVp (median score 3; interquartile range 3-3) was higher compared with conventional imaging at 120 kVp (2; 2-2), 100 kVp (1; 1-2), and 80 kVp (1; 1-1) (all p < 0.001). Indicated by an intraclass correlation coefficient of 0.945 (95% confidence interval: 0.927-0.960), interrater reliability was excellent. CONCLUSIONS: In abdominal CT with maximised dose reduction, tin prefiltration at 100 kVp allows for superior image quality over Sn 150 kVp and conventional imaging without spectral shaping.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X , Humanos , Reproducibilidad de los Resultados , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen
5.
BMC Oral Health ; 24(1): 341, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38493083

RESUMEN

BACKGROUND: Oral squamous carcinoma (OSCC) is often diagnosed at late stages and bone erosion or invasion of the jawbone is frequently present. Computed tomography (CT) and magnetic resonance imaging (MRI) are known to have high diagnostic sensitivities, specificities, and accuracies in detecting these bone affections in patients suffering from OSCC. To date, the existing data regarding the impact of cone-beam computed tomography (CBCT) have been weak. Therefore, this study aimed to investigate whether CBCT is a suitable tool to detect bone erosion or invasion in patients with OSCC. METHODS: We investigated in a prospective trial the impact of CBCT in the diagnosis of bone erosion or invasion in patients with OSCC who underwent surgery. Every participant received a CBCT, CT, and MRI scan during staging. Imaging modalities were evaluated by two specialists in oral and maxillofacial surgery (CBCT) and two specialists in radiology (CT and MRI) in a blinded way, to determine whether a bone affection was present or not. Reporting used the following 3-point system: no bony destruction ("0"), cortical bone erosion ("1"), or medullary bone invasion ("2"). Histological examination or a follow-up served to calculate the sensitivities, specificities, and accuracies of the imaging modalities. RESULTS: Our results revealed high diagnostic sensitivities (95.6%, 84.4%, and 88.9%), specificities (87.0%, 91.7%, and 91.7%), and accuracies (89.5%, 89.5%, and 90.8%) for CBCT, CT, and MRI. A pairwise comparison found no statistical difference between CBCT, CT, and MRI. CONCLUSION: Our data support the routine use of CBCT in the diagnosis of bone erosion and invasion in patients with OSCC as diagnostic accuracy is equal to CT and MRI, the procedure is cost-effective, and it can be performed during initial contact with the patient.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de Cabeza y Cuello , Neoplasias de la Boca , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Tomografía Computarizada de Haz Cónico , Células Epiteliales , Imagen por Resonancia Magnética , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/patología , Estudios Prospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello , Tomografía Computarizada por Rayos X
6.
Radiology ; 308(1): e230084, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37404154

RESUMEN

Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = -0.61, P = .01) but poor during follow-up (r = -0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.


Asunto(s)
Fibrosis Quística , Humanos , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/tratamiento farmacológico , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Mutación
7.
Radiology ; 306(3): e221200, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36346312

RESUMEN

Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Adulto , Niño , Humanos , Femenino , Dosis de Radiación , Codo , Estudios Retrospectivos , Tomografía Computarizada de Haz Cónico/métodos , Fracturas Óseas/diagnóstico por imagen
8.
Ann Rheum Dis ; 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37550004

RESUMEN

OBJECTIVES: To update the EULAR recommendations for the use of imaging modalities in primary large vessel vasculitis (LVV). METHODS: A systematic literature review update was performed to retrieve new evidence on ultrasound, MRI, CT and [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) for diagnosis, monitoring and outcome prediction in LVV. The task force consisted of 24 physicians, health professionals and patients from 14 countries. The recommendations were updated based on evidence and expert opinion, iterating until voting indicated consensus. The level of agreement was determined by anonymous votes. RESULTS: Three overarching principles and eight recommendations were agreed. Compared to the 2018 version, ultrasound is now recommended as first-line imaging test in all patients with suspected giant cell arteritis, and axillary arteries should be included in the standard examination. As an alternative to ultrasound, cranial and extracranial arteries can be examined by FDG-PET or MRI. For Takayasu arteritis, MRI is the preferred imaging modality; FDG-PET, CT or ultrasound are alternatives. Although imaging is not routinely recommended for follow-up, ultrasound, FDG-PET or MRI may be used for assessing vessel abnormalities in LVV patients with suspected relapse, particularly when laboratory markers of inflammation are unreliable. MR-angiography, CT-angiography or ultrasound may be used for long-term monitoring of structural damage, particularly at sites of preceding vascular inflammation. CONCLUSIONS: The 2023 EULAR recommendations provide up-to-date guidance for the role of imaging in the diagnosis and assessment of patients with LVV.

9.
Eur J Nucl Med Mol Imaging ; 50(12): 3765-3776, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37474735

RESUMEN

PURPOSE: The aim of this study was to investigate very early radiographic PSMA PET response after one cycle of [177Lu]Lu-PSMA I&T radioligand therapy (RLT) of metastatic castration-resistant prostate cancer (mCRPC) and to assess its role in predicting overall response and survival. METHODS: This retrospective study enrolled 40 mCRPC patients who were treated with a median of 3 (2-9) [177Lu]Lu-PSMA I&T RLT cycles. Biochemical response was based on the relative change of serum PSA according to PCWG3 criteria, while radiographic response referred to the relative change of PSMA-derived total viable tumor volumes expressed as total lesion PSMA (TLP). RESULTS: After one cycle of RLT, biochemical partial response (PR) was seen in 8/40 (20.0%), stable disease (SD) in 22/40 (55.0%), and progressive disease (PD) in 10/40 (25%) patients. In PSMA PET, very early molecular PR was observed in 12 (30.0%), SD in 19 (47.5%), and PD in 9 (22.5%) subjects. The PSA and TLP nadir were achieved after a median of 1 (1-5) and 2 (1-6) cycles, respectively. Nineteen (47.5%) patients showed overall biochemical PR, 11 (27.5%) had SD, and 10 (25%) experienced PD. In PSMA-directed PET, 4 patients experienced molecular complete response (CR), 24 (60.0%) had PR, 4 (10.0%) SD, and 8 (20.0%) PD. Early biochemical or radiographic response was not associated with longer overall survival (OS). Overall biochemical responders had a nearly significantly longer median OS (22.7 months) than non-responders (14.4 months, p = 0.08). Early PSA progression was associated with shorter OS (12.2 months), compared to biochemical SD/PR (18.7 months, p = 0.09). CONCLUSION: In this retrospective cohort, there was no association between early PSMA PET radiographic response and overall survival; hence, treatment should not be prematurely discontinued. In contrast, early PSA progression after one cycle of [177Lu]Lu-PSMA I&T RLT was an indicator of overall progression and poor clinical outcome.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Masculino , Humanos , Estudios Retrospectivos , Neoplasias de la Próstata Resistentes a la Castración/diagnóstico por imagen , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/tratamiento farmacológico , Resultado del Tratamiento , Antígeno Prostático Específico , Dipéptidos/uso terapéutico , Compuestos Heterocíclicos con 1 Anillo/uso terapéutico , Lutecio/uso terapéutico
10.
J Magn Reson Imaging ; 2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-37974498

RESUMEN

BACKGROUND: For time-consuming diffusion-weighted imaging (DWI) of the breast, deep learning-based imaging acceleration appears particularly promising. PURPOSE: To investigate a combined k-space-to-image reconstruction approach for scan time reduction and improved spatial resolution in breast DWI. STUDY TYPE: Retrospective. POPULATION: 133 women (age 49.7 ± 12.1 years) underwent multiparametric breast MRI. FIELD STRENGTH/SEQUENCE: 3.0T/T2 turbo spin echo, T1 3D gradient echo, DWI (800 and 1600 sec/mm2 ). ASSESSMENT: DWI data were retrospectively processed using deep learning-based k-space-to-image reconstruction (DL-DWI) and an additional super-resolution algorithm (SRDL-DWI). In addition to signal-to-noise ratio and apparent diffusion coefficient (ADC) comparisons among standard, DL- and SRDL-DWI, a range of quantitative similarity (e.g., structural similarity index [SSIM]) and error metrics (e.g., normalized root mean square error [NRMSE], symmetric mean absolute percent error [SMAPE], log accuracy error [LOGAC]) was calculated to analyze structural variations. Subjective image evaluation was performed independently by three radiologists on a seven-point rating scale. STATISTICAL TESTS: Friedman's rank-based analysis of variance with Bonferroni-corrected pairwise post-hoc tests. P < 0.05 was considered significant. RESULTS: Both DL- and SRDL-DWI allowed for a 39% reduction in simulated scan time over standard DWI (5 vs. 3 minutes). The highest image quality ratings were assigned to SRDL-DWI with good interreader agreement (ICC 0.834; 95% confidence interval 0.818-0.848). Irrespective of b-value, both standard and DL-DWI produced superior SNR compared to SRDL-DWI. ADC values were slightly higher in SRDL-DWI (+0.5%) and DL-DWI (+3.4%) than in standard DWI. Structural similarity was excellent between DL-/SRDL-DWI and standard DWI for either b value (SSIM ≥ 0.86). Calculation of error metrics (NRMSE ≤ 0.05, SMAPE ≤ 0.02, and LOGAC ≤ 0.04) supported the assumption of low voxel-wise error. DATA CONCLUSION: Deep learning-based k-space-to-image reconstruction reduces simulated scan time of breast DWI by 39% without influencing structural similarity. Additionally, super-resolution interpolation allows for substantial improvement of subjective image quality. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.

11.
Eur Radiol ; 33(11): 7818-7829, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37284870

RESUMEN

OBJECTIVES: While established for energy-integrating detector computed tomography (CT), the effect of virtual monoenergetic imaging (VMI) and iterative metal artifact reduction (iMAR) in photon-counting detector (PCD) CT lacks thorough investigation. This study evaluates VMI, iMAR, and combinations thereof in PCD-CT of patients with dental implants. MATERIAL AND METHODS: In 50 patients (25 women; mean age 62.0 ± 9.9 years), polychromatic 120 kVp imaging (T3D), VMI, T3DiMAR, and VMIiMAR were compared. VMIs were reconstructed at 40, 70, 110, 150, and 190 keV. Artifact reduction was assessed by attenuation and noise measurements in the most hyper- and hypodense artifacts, as well as in artifact-impaired soft tissue of the mouth floor. Three readers subjectively evaluated artifact extent and soft tissue interpretability. Furthermore, new artifacts through overcorrection were assessed. RESULTS: iMAR reduced hyper-/hypodense artifacts (T3D 1305.0/-1418.4 versus T3DiMAR 103.2/-46.9 HU), soft tissue impairment (106.7 versus 39.7 HU), and image noise (16.9 versus 5.2 HU) compared to non-iMAR datasets (p ≤ 0.001). VMIiMAR ≥ 110 keV subjectively enhanced artifact reduction over T3DiMAR (p ≤ 0.023). Without iMAR, VMI displayed no measurable artifact reduction (p ≥ 0.186) and facilitated no significant denoising over T3D (p ≥ 0.366). However, VMI ≥ 110 keV reduced soft tissue impairment (p ≤ 0.009). VMIiMAR ≥ 110 keV resulted in less overcorrection than T3DiMAR (p ≤ 0.001). Inter-reader reliability was moderate/good for hyperdense (0.707), hypodense (0.802), and soft tissue artifacts (0.804). CONCLUSION: While VMI alone holds minimal metal artifact reduction potential, iMAR post-processing enabled substantial reduction of hyperdense and hypodense artifacts. The combination of VMI ≥ 110 keV and iMAR resulted in the least extensive metal artifacts. CLINICAL RELEVANCE: Combining iMAR with VMI represents a potent tool for maxillofacial PCD-CT with dental implants achieving substantial artifact reduction and high image quality. KEY POINTS: • Post-processing of photon-counting CT scans with an iterative metal artifact reduction algorithm substantially reduces hyperdense and hypodense artifacts arising from dental implants. • Virtual monoenergetic images presented only minimal metal artifact reduction potential. • The combination of both provided a considerable benefit in subjective analysis compared to iterative metal artifact reduction alone.


Asunto(s)
Artefactos , Implantes Dentales , Humanos , Femenino , Persona de Mediana Edad , Anciano , Reproducibilidad de los Resultados , Metales , Tomografía Computarizada por Rayos X/métodos , Algoritmos
12.
Eur Radiol ; 33(11): 7830-7839, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37311805

RESUMEN

OBJECTIVE: To evaluate the image quality of an ultra-low contrast medium and radiation dose CT pulmonary angiography (CTPA) protocol for the diagnosis of acute pulmonary embolism using a clinical photon-counting detector (PCD) CT system and compare its performance to a dual-energy-(DE)-CTPA protocol on a conventional energy-integrating detector (EID) CT system. METHODS: Sixty-four patients either underwent CTPA with the novel scan protocol on the PCD-CT scanner (32 patients, 25 mL, CTDIvol 2.5 mGy·cm) or conventional DE-CTPA on a third-generation dual-source EID-CT (32 patients, 50 mL, CTDIvol 5.1 mGy·cm). Pulmonary artery CT attenuation, signal-to-noise ratio, and contrast-to-noise-ratio were assessed as objective criteria of image quality, while subjective ratings of four radiologists were compared at 60 keV using virtual monoenergetic imaging and polychromatic standard reconstructions. Interrater reliability was determined by means of the intraclass correlation coefficient (ICC). Effective dose was compared between patient cohorts. RESULTS: Subjective image quality was deemed superior by all four reviewers for 60-keV PCD scans (excellent or good ratings in 93.8% of PCD vs. 84.4% of 60 keV EID scans, ICC = 0.72). No examinations on either system were considered "non-diagnostic." Objective image quality parameters were significantly higher in the EID group (mostly p < 0.001), both in the polychromatic reconstructions and at 60 keV. The ED (1.4 vs. 3.3 mSv) was significantly lower in the PCD cohort (p < 0.001). CONCLUSIONS: PCD-CTPA allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism, while maintaining good to excellent image quality compared to conventional EID-CTPA. CLINICAL RELEVANCE STATEMENT: Clinical PCD-CT allows for spectral assessment of pulmonary vasculature with high scan speed, which is beneficial in patients with suspected pulmonary embolism, frequently presenting with dyspnea. Simultaneously PCD-CT enables substantial reduction of contrast medium and radiation dose. KEY POINTS: • The clinical photon-counting detector CT scanner used in this study allows for high-pitch multi-energy acquisitions. • Photon-counting computed tomography allows for considerable reduction of contrast medium and radiation dose in the diagnosis of acute pulmonary embolism. • Subjective image quality was rated best for 60-keV photon-counting scans.


Asunto(s)
Reducción Gradual de Medicamentos , Embolia Pulmonar , Humanos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Embolia Pulmonar/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Fotones , Fantasmas de Imagen
13.
Eur Radiol ; 33(11): 7913-7922, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37256352

RESUMEN

OBJECTIVES: We conducted a systematic review and individual participant data meta-analysis of publications reporting the ophthalmologic presentation, clinical exam, and orbital MRI findings in patients with giant cell arteritis and ocular manifestations. METHODS: PubMed and Cochrane databases were searched up to January 16, 2022. Publications reporting patient-level data on patients with ophthalmologic symptoms, imaged with orbital MRI, and diagnosed with biopsy-proven giant cell arteritis were included. Demographics, clinical symptoms, exam, lab, imaging, and outcomes data were extracted. The methodological quality and completeness of reporting of case reports were assessed. RESULTS: Thirty-two studies were included comprising 51 patients (females = 24; median age, 76 years). Vision loss (78%) and headache (45%) were commonly reported visual and cranial symptoms. Ophthalmologic presentation was unilateral (41%) or bilateral (59%). Fundus examination most commonly showed disc edema (64%) and pallor (49%). Average visual acuity was very poor (2.28 logMAR ± 2.18). Diagnoses included anterior (61%) and posterior (16%) ischemic optic neuropathy, central retinal artery occlusion (8%), and orbital infarction syndrome (2%). On MRI, enhancement of the optic nerve sheath (53%), intraconal fat (25%), and optic nerve/chiasm (14%) was most prevalent. Among patients with monocular visual symptoms, 38% showed pathologic enhancement in the asymptomatic orbit. Six of seven cases reported imaging resolution after treatment on follow-up MRIs. CONCLUSIONS: Vision loss, pallid disc edema, and optic nerve sheath enhancement are the most common clinical, fundoscopic, and imaging findings reported in patients diagnosed with giant cell arteritis with ocular manifestations, respectively. MRI may detect subclinical inflammation and ischemia in the asymptomatic eye and may be an adjunct diagnostic tool. CLINICAL RELEVANCE STATEMENT: Brain and orbital MRIs may have diagnostic and prognostic roles in patients with suspected giant cell arteritis who present with ophthalmic symptoms.


Asunto(s)
Arteritis de Células Gigantes , Neuropatía Óptica Isquémica , Femenino , Humanos , Anciano , Arteritis de Células Gigantes/complicaciones , Arteritis de Células Gigantes/diagnóstico por imagen , Trastornos de la Visión , Imagen por Resonancia Magnética/métodos , Neuropatía Óptica Isquémica/diagnóstico , Neuropatía Óptica Isquémica/etiología , Edema/complicaciones
14.
Eur Radiol ; 33(4): 2529-2535, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36394601

RESUMEN

OBJECTIVE: Blindness is a feared complication of giant cell arteritis (GCA). However, the spectrum of pathologic orbital imaging findings on magnetic resonance imaging (MRI) in GCA is not well understood. In this study, we assess inflammatory changes of intraorbital structures on black blood MRI (BB-MRI) in patients with GCA compared to age-matched controls. METHODS: In this multicenter case-control study, 106 subjects underwent BB-MRI. Fifty-six patients with clinically or histologically diagnosed GCA and 50 age-matched controls without clinical or laboratory evidence of vasculitis were included. All individuals were imaged on a 3-T MR scanner with a post-contrast compressed-sensing (CS) T1-weighted sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) BB-MRI sequence. Imaging results were correlated with available clinical symptoms. RESULTS: Eighteen of 56 GCA patients (32%) showed inflammatory changes of at least one of the intraorbital structures. The most common finding was enhancement of at least one of the optic nerve sheaths (N = 13, 72%). Vessel wall enhancement of the ophthalmic artery was unilateral in 8 and bilateral in 3 patients. Enhancement of the optic nerve was observed in one patient. There was no significant correlation between imaging features of inflammation and clinically reported orbital symptoms (p = 0.10). None of the age-matched control patients showed any inflammatory changes of intraorbital structures. CONCLUSIONS: BB-MRI revealed inflammatory findings in the orbits in up to 32% of patients with GCA. Optic nerve sheath enhancement was the most common intraorbital inflammatory change on BB-MRI. MRI findings were independent of clinically reported orbital symptoms. KEY POINTS: • Up to 32% of GCA patients shows signs of inflammation of intraorbital structures on BB-MRI. • Enhancement of the optic nerve sheath is the most common intraorbital finding in GCA patients on BB-MRI. • Features of inflammation of intraorbital structures are independent of clinically reported symptoms.


Asunto(s)
Arteritis de Células Gigantes , Humanos , Arteritis de Células Gigantes/complicaciones , Arteritis de Células Gigantes/diagnóstico por imagen , Estudios de Casos y Controles , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Inflamación/patología , Arterias Temporales/patología
15.
Arch Orthop Trauma Surg ; 143(12): 7097-7105, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37639044

RESUMEN

INTRODUCTION: The AMADEUS (Area Measurement And DEpth and Underlying Structures) score has advanced to a commonly used tool for MRI-based chondral defect severity grading prior to cartilage knee surgery. It was the intention of this study to assess the AMADEUS for a potential correlation with clinical data by patient-reported outcome measures (PROMs). METHODS: A total of 51 patients undergoing ACI (autologous chondrocyte implantation) between 2016 and 2022 were found eligible and retrospectively analyzed. All patients were registered in the German Cartilage Registry prior to surgery and follow-up data were collected using the Knee Osteoarthritis Outcome score (KOOS), the International Knee Documentation Committee (IKDC) Form and the numeric rating scale (NRS). Pre-operative MRI images were scored by three raters using the AMADEUS classification system, and an overall AMADEUS score was calculated which was subsequently correlated with pre- and post-operative PROMs. RESULTS: Mean patient age was 32.67 ± 8.37 years and mean defect size area 343.04 mm2 ± 139.45 mm2. No correlative capacity of the pre- and postoperative IKDC, KOOS or NRS scores was found with the AMADEUS final score or any of its subscores. From the pre- to postoperative visit, a significant improvement of the PROMs (IKDC: 45.53 ± 21.00 vs. 59.83 ± 17.93, p = 0.04; KOOS Pain: 58.00 ± 16.70 vs. 76.06 ± 19.20, p = 0.03; KOOS ADL: 64.17 ± 18.76 vs. 82.11 ± 16.68, p < 0.01; KOOS Sports: 26.11 ± 18.52 vs. 50.56 ± 23.94, p = 0.01; KOOS QOL: 25.50 ± 14.26 ± 45.28 ± 19.03, p = 0.00) was found. Intraclass correlation coefficients showed an overall good interrater agreement for the AMADEUS total score (ICC = 0.75). CONCLUSIONS: Study results suggest no correlative capacity of the AMADEUS with routinely used PROMs in patients undergoing ACI. Therefore, radiographically assessed cartilage defect characteristics poorly translate to pre- and postoperative patient-reported outcome data.


Asunto(s)
Enfermedades de los Cartílagos , Cartílago Articular , Osteoartritis de la Rodilla , Humanos , Adulto Joven , Adulto , Condrocitos , Cartílago Articular/cirugía , Estudios Retrospectivos , Calidad de Vida , Trasplante Autólogo/métodos , Articulación de la Rodilla/cirugía , Enfermedades de los Cartílagos/cirugía , Osteoartritis de la Rodilla/cirugía , Dolor , Sistema de Registros
16.
Br J Haematol ; 198(3): 515-522, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35582835

RESUMEN

Measurement of minimal residual disease (MRD) by next-generation flow cytometry (NGF) is an important tool to define deep responses in multiple myeloma (MM). However, little is known about the value of combining NGF with functional imaging and its role for MRD-based consolidation strategies in clinical routine. In the present study, we report our experience investigating these issues with 102 patients with newly diagnosed (n = 57) and relapsed/refractory MM (n = 45). Imaging was performed using either positron emission tomography or diffusion-weighted magnetic resonance imaging. In all, 45% of patients achieved MRD-negativity on both NGF and imaging (double-negativity), and 8% and 40% of patients were negative on either NGF or imaging respectively. Thus, in a minority of patients imaging was the only technique to detect residual disease. Imaging-positivity despite negativity on NGF was more common in heavily pretreated disease (four or more previous lines) compared to newly diagnosed MM (p < 0.01). Among the 29 patients undergoing MRD-triggered consolidation, 51% responded with MRD conversion and 21% with improved serological response. MRD-triggered consolidation led to superior progression-free survival (PFS) when compared to standard treatment (p = 0.04). In conclusion, we show that combining NGF with imaging is helpful particularly in patients with heavily pretreated MM, and that MRD-based consolidation could lead to improved PFS.


Asunto(s)
Citometría de Flujo , Mieloma Múltiple , Citometría de Flujo/métodos , Humanos , Imagen por Resonancia Magnética , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/tratamiento farmacológico , Neoplasia Residual/diagnóstico por imagen , Tomografía de Emisión de Positrones , Resultado del Tratamiento
17.
Magn Reson Med ; 87(2): 972-983, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34609026

RESUMEN

PURPOSE: Image acquisition and subsequent manual analysis of cardiac cine MRI is time-consuming. The purpose of this study was to train and evaluate a 3D artificial neural network for semantic segmentation of radially undersampled cardiac MRI to accelerate both scan time and postprocessing. METHODS: A database of Cartesian short-axis MR images of the heart (148,500 images, 484 examinations) was assembled from an openly accessible database and radial undersampling was simulated. A 3D U-Net architecture was pretrained for segmentation of undersampled spatiotemporal cine MRI. Transfer learning was then performed using samples from a second database, comprising 108 non-Cartesian radial cine series of the midventricular myocardium to optimize the performance for authentic data. The performance was evaluated for different levels of undersampling by the Dice similarity coefficient (DSC) with respect to reference labels, as well as by deriving ventricular volumes and myocardial masses. RESULTS: Without transfer learning, the pretrained model performed moderately on true radial data [maximum number of projections tested, P = 196; DSC = 0.87 (left ventricle), DSC = 0.76 (myocardium), and DSC =0.64 (right ventricle)]. After transfer learning with authentic data, the predictions achieved human level even for high undersampling rates (P = 33, DSC = 0.95, 0.87, and 0.93) without significant difference compared with segmentations derived from fully sampled data. CONCLUSION: A 3D U-Net architecture can be used for semantic segmentation of radially undersampled cine acquisitions, achieving a performance comparable with human experts in fully sampled data. This approach can jointly accelerate time-consuming cine image acquisition and cumbersome manual image analysis.


Asunto(s)
Corazón , Semántica , Corazón/diagnóstico por imagen , Ventrículos Cardíacos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Redes Neurales de la Computación
18.
Magn Reson Med ; 88(5): 2167-2178, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35692042

RESUMEN

PURPOSE: Cardiac MRI represents the gold standard to determine myocardial function. However, the current clinical standard protocol, a segmented Cartesian acquisition, is time-consuming and can lead to compromised image quality in the case of arrhythmia or dyspnea. In this article, a machine learning-based reconstruction of undersampled spiral k-space data is presented to enable free breathing real-time cardiac MRI with good image quality and short reconstruction times. METHODS: Data were acquired in free breathing with a 2D spiral trajectory corrected by the gradient system transfer function. Undersampled data were reconstructed by a variational network (VN), which was specifically adapted to the non-Cartesian sampling pattern. The network was trained with data from 11 subjects. Subsequently, the imaging technique was validated in 14 subjects by quantifying the difference to a segmented reference acquisition, an expert reader study, and by comparing derived volumes and functional parameters with values obtained using the current clinical gold standard. RESULTS: The scan time for the entire heart was below 1 min. The VN reconstructed data in about 0.9 s per image, which is considerably shorter than conventional model-based approaches. The VN furthermore performed better than a U-Net and not inferior to a low-rank plus sparse model in terms of achieved image quality. Functional parameters agreed, on average, with reference data. CONCLUSIONS: The proposed VN method enables real-time cardiac imaging with both high spatial and temporal resolution in free breathing and with short reconstruction time.


Asunto(s)
Imagen por Resonancia Magnética , Respiración , Corazón/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Cintigrafía
19.
NMR Biomed ; 35(8): e4732, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35297111

RESUMEN

The purpose of the current study was to implement and validate joint real-time acquisition of functional and late gadolinium-enhancement (LGE) cardiac magnetic resonance (MR) images during free breathing. Inversion recovery cardiac real-time images with a temporal resolution of 50 ms were acquired using a spiral trajectory (IR-CRISPI) with a pre-emphasis based on the gradient system transfer function during free breathing. Functional and LGE cardiac MR images were reconstructed using a low-rank plus sparse model. Late gadolinium-enhancement appearance, image quality, and functional parameters of IR-CRISPI were compared with clinical standard balanced steady-state free precession breath-hold techniques in 10 patients. The acquisition of IR-CRISPI in free breathing of the entire left ventricle took 97 s on average. Bland-Altman analysis and Wilcoxon tests showed a higher artifact level for the breath-hold technique (p = 0.003), especially for arrhythmic patients or patients with dyspnea, but an increased noise level for IR-CRISPI of the LGE images (p = 0.01). The estimated transmural extent of the enhancement differed by not more than 25% and did not show a significant bias between the techniques (p = 0.50). The ascertained functional parameters were similar for the breath-hold technique and IR-CRISPI, that is, with a minor, nonsignificant (p = 0.16) mean difference of the ejection fraction of 2.3% and a 95% confidence interval from -4.8% to 9.4%. IR-CRISPI enables joint functional and LGE imaging in free breathing with good image quality but distinctly shorter scan times in comparison with breath-hold techniques.


Asunto(s)
Medios de Contraste , Gadolinio , Contencion de la Respiración , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados
20.
Eur Radiol ; 32(2): 1276-1284, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34347156

RESUMEN

OBJECTIVES: Vessel wall enhancement (VWE) may be commonly seen on MRI images of asymptomatic subjects. This study aimed to characterize the VWE of the proximal internal carotid (ICA) and vertebral arteries (VA) in a non-vasculitic elderly patient cohort. METHODS: Cranial MRI scans at 3 Tesla were performed in 43 patients (aged ≥ 50 years) with known malignancy for exclusion of cerebral metastases. For vessel wall imaging (VWI), a high-resolution compressed-sensing black-blood 3D T1-weighted fast (turbo) spin echo sequence (T1 CS-SPACE prototype) was applied post gadolinium with an isotropic resolution of 0.55 mm. Bilateral proximal intradural ICA and VA segments were evaluated for presence, morphology, and longitudinal extension of VWE. RESULTS: Concentric VWE of the proximal intradural ICA was found in 13 (30%) patients, and of the proximal intradural VA in 39 (91%) patients. Mean longitudinal extension of VWE after dural entry was 13 mm in the VA and 2 mm in the ICA. In 14 of 39 patients (36%) with proximal intradural VWE, morphology of VWE was suggestive of the mere presence of vasa vasorum. In 25 patients (64 %), morphology indicated atherosclerotic lesions in addition to vasa vasorum. CONCLUSIONS: Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in elderly subjects. Concentric VWE in these locations should not be confused with large artery vasculitis. Distal to these segments, VWE may be more likely related to pathologic conditions such as vasculitis. KEY POINTS: • Vasa vasorum may account for concentric VWE within the proximal 2 mm of the ICA and 13 mm of the VA after dural entry in non-vasculitic elderly people. • Concentric enhancement within the proximal 2 mm of the intradural ICA and within the proximal 13 mm of the intradural VA portions should not be misinterpreted as vasculitis. • Distal of this, VWE is likely related to pathologic conditions, in case of concentric VWE suggestive of vasculitis.


Asunto(s)
Vasa Vasorum , Vasculitis , Anciano , Arterias Cerebrales , Humanos , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Vasa Vasorum/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA